  page 1 of 4 ? enclosed power supplies with screw terminal block ? universal input range 90 to 264 vac ? ready to meet erp directive, < 0.3 w no load power consumption ? adjustable output voltage ? 4242 vdc i/o-isolation ? high effciency up to 88 % ? operating temperature range: C30c to +70c max. ? short circuit and over voltage protection the txh 060 series is a family of power supplies in metal enclosure, designed for a wide range of cost critical applications. the high effciency of up to 88% is achieved through an innovative design for free air convection cooling. this design also qualifes the power supply to meet the erp directive ( < 0.3 w no load power consumption). the units are equiped with screw terminal blocks and are easy to install in any equipment. these power supplies have universal input and comply with european emc standards and the low voltage directive (lvd). order code output power (max.) output voltage (nom.)(adjustable) output current (max.) effciency (typ.) txh 060-105 50 w 5.0 vdc 10'000 ma 81 % txh 060-112 60 w 12 vdc 5'000 ma 87 % txh 060-115 60 w 15 vdc 4'000 ma 87 % txh 060-124 60 w 24 vdc 2'500 ma 88 % txh 060-148 60 w 48 vdc 1'250 ma 88 % models www.tracopower.com ac/dc power supplies txh 060 series, 60 w
page 2 of 4 all specifcations valid at nominal input voltage, full load and +25c after warm-up time unless otherwise stated. input specifications input voltage C ac input 90 C 264 vac all models: derating of 2%/v below 100 vac required C dc input 120 C 370 vdc input frequency 47 C 63 hz leakage current < 0.75 ma inrush current* (115 / 2 3 0 va c ) 35 a max. / 70 a max. no-load power consumption (at input voltage < 230 vac) < 0.3 w output specifications voltage accuracy 2 % typ. voltage adjustment 5 % regulation C input variation 1.0 % typ. C load variation (5C100 %) 1.0 % typ. minimum load not required hold-up time (at input voltage 115 vac) 10 ms min. ripple and noise (20mhz bandwidth) 5 vdc model: 75 mvp-p max. (measured with 0.1f & 47f parallel capacitor) 12 vdc model: 100 mvp-p max. 15 vdc model: 125 mvp-p max. 24 vdc model: 150 mvp-p max. 48 vdc model: 200 mvp-p max. current limitation at 150% of nominal iout typ. short circuit current hiccup, automatic recovery output overvoltage protection zener diode maximum capacitive load 5 vdc model: 10'000 f 12 vdc model: 5'000 f 15 vdc model: 4'000 f 24 vdc model: 2'000 f 48 vdc model: 1'000 f general specifications temperature ranges C operational (natural convection 20 lfm) C30 c to +70 c max. C storage temperature C50 c to +85 c max. power derating see derating graph on page 3 temperature coefficient 0.02 %/k cooling convection cooling, no internal fan humidity (non condensing) 95 % rel. h max. altitude during operation 3100 m max. switching frequency (at 230 vac) 65 khz typ. isolation C input/output 4242 vdc C input/ground 2121 vdc C output/ground 707 vdc * an external thermistor has to be integreated in the circuit at the converter input l (in series). thermistor recommendation: 10r / 15z www.tracopower.com txh 060 series, 60 w
page 3 of 4 general specifications (continued) mtbf (mil-hdbk-217f, at 25 c ground benign) > 130000 h vibration 10-500 hz, 2g 10 min./1 cycle 60 min each along x, y, z axes. protection class class i safety standards i ec/en 60950 -1 u l 60950 -1 C certification documents www.tracopower.com/overview/TXH060 electromagnetic compatibility (emc), emissions C conducted/radiated ri suppression on input en 55022 class b electromagnetic compatibility (emc), immunity en 55024 C electrostatic discharge (esd) iec/en 61000-4-2, 4 kv / 8 kv, criteria a C radiated rf field immunity iec/en 61000-4-3, 10 v/m, criteria a C electrical fast transient / burst immunity iec/en 61000-4-4, 2 kv, criteria a C surge immunity iec/en 61000-4-5, 1 kv, criteria a C immunity to conducted rf disturbances iec/en 61000-4-6, 10 v, criteria a C magnetic field immunity iec/en 61000-4-8, 30 a/m, criteria a C mains voltage dips and interruptions iec/en 61000-4-11 >95 %, 250 periods, perf. criteria c 30 %, 25 periods, perf. criteria a >95 %, 0.5 periods, perf. criteria a case material metal enclosure environmental compliance C reach www.tracopower.com/products/reach-declaration.pdf C rohs rohs directive 2011/65/eu 30 40 50 60 70 100 80 60 40 20 0 output power [%] ambient temperature [c] -30 12-48 vdc models 5 vdc model txh 060 derating graph: www.tracopower.com txh 060 series, 60 w
www .tracopowe r. com ? copyright 2017 traco electronic ag sp ec i?cati ons can be changed wi thout noti ce! page 4 of 4 outline dimensions weight: 220 g (7.76 oz) pin single 1 ac in (n) 2 ac in (l) 3 gnd 4 +vout 5 Cvout pinout dimensions in [mm] tolerances: 0.5 mm pin tolerances: 0.1 mm a: for fxture to din rail clip only. a=m3x0.5p b: for fxture to pcb/chassis only. b=m3x0.5p mounting/locking kit should not be screwed in more than 3mm. rev. december 18. 2017 txh 060 series, 60 w


▲Up To Search▲   

 
Price & Availability of TXH060

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X