Part Number Hot Search : 
C51CC01U AS300DA KIA7727P PC1313HA DDZX9714 ICS8521 MOG2388C TA7280P
Product Description
Full Text Search
 

To Download GTDASPA113-GSGU-26-1 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  2018-01-15 1 2018-01-15 duris p 5 datasheet version 1.3 (not for new design) gt daspa1.13 high-efficacy mid-power led with long lifetimes als o at high currents and high junction temperatures. hocheffiziente led mittlerer leistungsklasse mit langer lebensdauer auch bei hohen str?men und hohen sperrschichttemperaturen. features: besondere merkmale: ? package: smt package ? geh?usetyp: smt geh?use ? viewing angle at 50 % i v : 120 ? abstrahlwinkel bei 50 % i v : 120 ? color: 519 nm (true green) ? farbe: 519 nm (true green) ? luminous flux: typ. 26 lm ? lichtstrom: typ. 26 lm ? luminous efficacy: typ. 80 lm/w ? lichtausbeute: typ. 80 lm/w applications anwendungen ? architectural lighting ? architekturbeleuchtung ? accent and effect lighting ? akzent- und effektbeleuchtung ? room lighting: ceiling light, cove lighting, chandeliers, pendants, sconces ? raumbeleuchtung: deckenbeleuchtung, nischenbeleuchtung, kronleuchter, h?ngeleuchten, wandleuchter ? channel letters ? leuchtlettern ? linear lights ? linearbeleuchtung
2018-01-15 2 version 1.3 (not for new design) gt daspa1.13 ordering information bestellinformation type: luminous flux 1) page 20 ordering code typ: lichtstrom 1) seite 20 bestellnummer i f = 100 ma v [lm] gt daspa1.13-gsgu-26-1 22.4 ... 28 q65111a4405 note: the above type numbers represent the order gr oups which include only a few brightness groups (se e page 5). only one group will be shipped on each packing unit (there will be no m ixing of two groups on each packing unit). e. g. gt daspa1.13-gsgu-26-1 means that only one group gs, gt, gu will be shippa ble for any packing unit. in a similar manner for colors where wavelength gro ups are measured and binned, single wavelength grou ps will be shipped on any one packing unit. e. g. gt daspa1.13-gsgu-26-1 mean s that only one wavelength group 2,3,4,5,6 will be shippable. gt daspa1.13-gsgu-26-1 means that the device will be s hipped within the specified limits as stated on pag e 5. in a similar manner for colors where forward voltag e groups are measured and binned, single forward vo ltage groups will be shipped on any packing unit. e. g. gt daspa1.13-gsgu-26-1 m eans that only one forward voltage group k,l,m,n,p will be shippable. anm.: die oben genannten typbezeichnungen umfassen die bestellbaren selektionen. diese bestehen aus we nigen helligkeitsgruppen (siehe seite 5). es wird nur eine einzige helligkei tsgruppe pro verpackungseinheit geliefert. z. b. gt daspa1.13-gsgu-26-1 bedeutet, dass in einer verpackungseinheit nur eine der helligkeitsgruppen gs, gt, gu enhalten ist. gleiches gilt fr die farben, bei denen wellenl?nge ngruppen gemessen und gruppiert werden. pro verpack ungseinheit wird nur eine wellenl?ngengruppe geliefert. z. b. gt daspa1.13-gs gu-26-1 bedeutet, dass in einer verpackungseinheit nur eine der wellenl?ngengruppen 2,3,4,5,6 enthalten ist (siehe seite 5). gt daspa1.13-gsgu-26-1 bedeutet, dass das bauteil innerhalb der spezifizierten grenzen geliefert wird. gleiches gilt fr die leds, bei denen die durchlass spannungsgruppen gemessen und gruppiert werden. pro verpackungseinheit wird nur eine durchlassspannungsgruppe geliefert. z . b. gt daspa1.13-gsgu-26-1 bedeutet, dass nach durchlassspannungsgruppen gruppiert wird. in einer verpackungseinheit ist nur eine der durchlassspannu ngsgruppen k,l,m,n,p enthalten (siehe seite 5).
version 1.3 (not for new design) gt daspa1.13 2018-01-15 3 maximum ratings grenzwerte parameter symbol values unit bezeichnung symbol werte einheit operating temperature range betriebstemperatur t op -40 ... 120 c storage temperature range lagertemperatur t stg -40 ... 120 c junction temperature absolute * sperrschichttemperatur absolut * t j, abs 150 c junction temperature sperrschichttemperatur t j 125 c forward current durchlassstrom (t j = 25 c) i f 30 ... 250 ma reverse current 2) page 20 sperrstrom 2) seite 20 i r 200 ma esd withstand voltage esd festigkeit (acc. to ansi/esda/jedec js-001 - hbm, class 3b) v esd 8 kv note : * this is verified by testing 30 pieces. pass criteri a: no catastrophic failures allowed, luminous flux must be better than l70b50 after 1000 h. anm : * dieser wert wird durch den test von 30 bauteilen ab gesichert. dabei drfen keine totalausf?lle auftret en und der lichtstrom mu? nach 1000 h ber l70b50 liegen.
 a   
    .  '

'  -( e h+9ji g h2. 6  
  %
 )%-&  & 
" 3 '   )%-& 4 
5 
16  
  "    1  *
         - . k  " ,   16  
  ?.      *
 ?. 
  -  . - . -l . k  k  k  ?  a?    $ #  mi  l $ " d#  # mi  l - . nk ??  ;  

 mi ; 2#  " # mi ; - . o  + g6
 a.    
 a. 
  -  . - . -l . ; g ; g ; g  / ?  ? / ; ; ; 3 6  6
$ 
-i 3 h2. -l . ; 3   ; p  p     0   p "  p1*   $   0 % -    q hrm. - . 3  e$   801
  /    
 #
 '  & <


version 1.3 (not for new design) gt daspa1.13 2018-01-15 5 brightness groups helligkeitsgruppen forward voltage groups 4) page 20 durchlassspannungsgruppen 4) seite 20 dominant wavelength groups 7) page 20 dominant wellenl?ngengruppen 7) seite 20 group luminous flux 1) page 20 luminous flux 1) page 20 luminous intensity 6) page 20 gruppe lichtstrom 1) seite 20 lichtstrom 1) seite 20 lichtst?rke 6) seite 20 (min.) v [lm] (max.) v [lm] (typ.) i v [cd] gr 21 22.4 6.9 gs 22.4 24 7.4 gt 24 25.9 8 gu 25.9 28 8.6 group gruppe (min.) v f [v] (max.) v f [v] k 2.60 2.80 l 2.80 3.00 m 3.00 3.20 n 3.20 3.40 p 3.40 3.60 group true green gruppe (min.) dom [nm] (max.) dom [nm] 2 513 519 3 519 525 4 525 531 5 531 537 6 537 543 note: no packing unit / tape ever contains more tha n one color group for each selection. anm.: in einer verpackungseinheit / gurt ist immer nur eine gruppe fr jede farbe enthalten.
2018-01-15 6 version 1.3 (not for new design) gt daspa1.13 group name on label gruppenbezeichnung auf etikett example: gs-2-l beispiel: gs-2-l brightness helligkeit wavelength wellenl?nge forward voltage durchlassspannung gs 2 l note: no packing unit / tape ever contains more tha n one group for each selection. anm.: in einer verpackungseinheit / gurt ist immer nur eine gruppe fr jede selektion enthalten.
version 1.3 (not for new design) gt daspa1.13 2018-01-15 7 relative spectral emission - v() = standard eye re sponse curve 6) page 20 relative spektrale emission - v() = spektrale auge nempfindlichkeit 6) seite 20 rel = f (); t j = 25 c; i f = 100 ma radiation characteristics 6) page 20 abstrahlcharakteristik 6) seite 20 i rel = f (?); t j = 25 c gt daspa1.13 350 400 450 500 550 600 650 700 750 800 l [nm] 0.0 0.2 0.4 0.6 0.8 1.0 i rel : true green : v l gt daspa1.13 -100 -90 -80 -70 -60 -50 -40 -30 -20 -10 0 10 20 30 40 50 60 70 80 90 j [] 0.0 0.2 0.4 0.6 0.8 1.0 i rel
2018-01-15 8 version 1.3 (not for new design) gt daspa1.13 forward current 6) page 20 , 8) page 20 durchlassstrom 6) seite 20 , 8) seite 20 i f = f (v f ); t j = 25 c relative luminous flux 6) page 20 , 8) page 20 relativer lichtstrom 6) seite 20 , 8) seite 20 v / v (100 ma) = f(i f ); t j = 25 c dominant wavelength 6) page 20 dominante wellenl?nge 6) seite 20 dom = f(i f ); t j = 25 c gt daspa1.13 2.8 3.0 3.2 3.4 v f [v] 50 100 150 200 250 i f [ma] gt daspa1.13 50 10 0 15 0 20 0 25 0 30 i f [ma] 0.0 0.5 1.0 1.5 2.0 f v f v (100 ma ) gt daspa1.13 50 10 0 15 0 20 0 25 0 i f [ma] -10 -5 0 5 10 dl dom [nm]
version 1.3 (not for new design) gt daspa1.13 2018-01-15 9 relative forward voltage 6) page 20 relative vorw?rtsspannung 6) seite 20 v f = v f - v f (25 c) = f(t j ); i f = 100 ma relative luminous flux 6) page 20 relativer lichtstrom 6) seite 20 v / v (25 c) = f(t j ); i f = 100 ma dominant wavelength 6) page 20 dominante wellenl?nge 6) seite 20 dom = f(t j ); i f = 100 ma gt daspa1.13 -40 -20 0 20 40 60 80 100 120 t j [c] -0.4 -0.2 0.0 0.2 0.4 d v f [v] gt daspa1.13 -40 -20 0 20 40 60 80 100 120 t j [c] 0.0 0.2 0.4 0.6 0.8 1.0 1.2 f v f v (25 c ) gt daspa1.13 -40 -20 0 20 40 60 80 100 120 t j [c] -10 -5 0 5 10 dl dom [nm]
    
    # 0 % -&  .  
  # 03 &(   ' &
%  , ) i 7 0 20 40 60 80 100 120 140 t s [c] 0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 i f [ma] do not use below 30 ma gx daspa1.xx
version 1.3 (not for new design) gt daspa1.13 2018-01-15 11 package outline 9) page 20 ma?zeichnung 9) seite 20 approximate weight: 30 mg gewicht: 30 mg esd information: led is protected by esd device which is connected in parallel to led-chip. esd information: die led enth?lt ein esd-bauteil, das parallel zum chip geschaltet ist.
2018-01-15 12 version 1.3 (not for new design) gt daspa1.13 recommended solder pad 9) page 20 reflow soldering empfohlenes l?tpaddesign 9) seite 20 reflow-l?ten
version 1.3 (not for new design) gt daspa1.13 2018-01-15 13 note: package not suitable for ultra sonic cleaning. for superior solder joint connectivity results we recommend soldering under standard nitrogen atmosphere . anm.: das geh?use ist fr ultraschallreinigung nicht geeignet. um eine verbesserte l?tstellenkontaktierung zu erreichen, empfehlen wir, unter standard- stickstoffatmosph?re zu l?ten.
2018-01-15 14 version 1.3 (not for new design) gt daspa1.13 reflow soldering profile reflow-l?tprofil product complies to msl level 2 acc. to jedec j-std -020e 0 0 s oha04525 50 100 150 200 250 300 50 100 150 200 250 300 t t ?c s t t p t t p 240 ?c 217 ?c 245 ?c 25 ?c l oha04612 profile featureprofil-charakteristik ramp-up rate to preheat* ) 25 c to 150 c 2 3 k/s time t s t smin to t smax t s t l t p t l t p 100 120 60 10 20 30 80 100 217 2 3 245 260 3 6 time25 c to t p time within 5 c of the specified peaktemperature t p - 5 k ramp-down rate*t p to 100 c all temperatures refer to the center of the package, measured on the top of the component* slope calculation d t/ d t: d t max. 5 s; fulfillment for the whole t-range ramp-up rate to peak* ) t smax to t p liquidus temperaturepeak temperature time above liquidus temperature symbolsymbol uniteinheit pb-free (snagcu) assembly minimum maximum recommendation k/sk/s s ss s c c 480
version 1.3 (not for new design) gt daspa1.13 2018-01-15 15 taping 9) page 20 gurtung 9) seite 20
2018-01-15 16 version 1.3 (not for new design) gt daspa1.13 tape dimensions [mm] gurtma?e [mm] tape dim ensions in m m reel dimensions [mm] rollenma?e [mm] reel dim ensions in m m tape and reel gurtverpackung 12 mm tape with 600 pcs. on ? 180 mm reel w p 0 p 1 p 2 d 0 e f 12 + 0.3 / - 0.1 4 0.1 4 0.1 or 8 0.1 2 0.05 1.5 0.1 1.75 0.1 5.5 0.05 a w n min w 1 w 2max 180 12 60 12.4 + 2 18.4 d 0 2 p p 0 1 p w f e direction of unreeling n w 1 2 w a ohay0324 label leader: trailer: 13.0 direction of unreeling 0.25 min. 160 mm * min. 400 mm * *) dimensions acc. to iec 60286-3; eia 481-d
barcode-product-label (bpl) barcode-produkt-etikett (bpl) dry packing process and materials trockenverpackung und materialien note: moisture-sensitive product is packed in a dry bag containing desiccant and a humidity card. regarding dry pack you will find further information in the internet and in the short form catalog in chapter tape and reel under the topic dry pack. here you will also find the normative references like jedec. anm.: feuchteempfindliche produkte sind verpackt in einem trockenbeutel zusammen mit einem trockenmittel und einer feuchteindikatorkarte. bezglich trockenverpackung finden sie weitere hinweise im internet und in unserem short form catalog im kapitel gurtung und verpackung unter dem punkt trockenverpackung. hier sind normenbezge, unter anderem ein auszug der jedec-norm, enthalten. oha00539 osram moisture-sensitive label or print barcode label desiccant humidity indicator barcode label osram please check the hic immidiately after bag opening. discard if circles overrun. avoid metal contact. wet do not eat. comparator check dot parts still adequately dry. examine units, if necessary examine units, if necessary 5% 15% 10% bake units bake units if wet, change desiccant if wet, humidity indicator mil-i-8835 if wet, moisture level 3 floor time 168 hours moisture level 6 floor time 6 hours a) humidity indicator card is > 10% when read at 23 ?c 5 ?c, or reflow, vapor-phase reflow, or equivalent processing (peak package 2. after this bag is opened, devices that will be subjected to infrared 1. shelf life in sealed bag: 24 months at < 40 ?c and < 90% relative humidity (rh). moisture level 5a at factory conditions of (if blank, seal date is identical with date code). a) mounted within b) stored at body temp. 3. devices require baking, before mounting, if: bag seal date moisture level 1 moisture level 2 moisture level 2a 4. if baking is required, b) 2a or 2b is not met. date and time opened: reference ipc/jedec j-std-033 for bake procedure. floor time see below if blank, see bar code label floor time > 1 year floor time 1 year floor time 4 weeks 10% rh. _ < moisture level 4 moisture level 5 ?c). opto semiconductors moisture sensitive this bag contains caution floor time 72 hours floor time 48 hours floor time 24 hours 30 ?c/60% rh. _ < level if blank, see bar code label 2018-01-15 17 version 1.3 (not for new design) gt daspa1.13
transportation packing and materials kartonverpackung und materialien dimensions of transportation box in mm width length height breite l?nge h?he 195 5 195 5 30 5 oha02044 packvar: r077 additional text p-1+q-1 multi topled muster osram opto semiconductors (6p) batch no: (x) prod no: 1 0 (9d) d/c: 1 1 (1t) lot no: 210021998 123gh1234 0 2 4 5 (q)qty: 2000 0144 (g) group: 260 c rt 240 c r 3 220 c r ml bin3: bin2: q-1-20 bin1: p-1-20 lsy t676 2 2a temp st r18 demy packvar: r077 additional text p-1+q-1 multi topled muster osram opto semiconductors (6p) batch no: (x) prod no: 1 0 (9d) d/c: 1 1 (1t) lot no: 210021998 123gh1234 0 2 4 5 (q)qty: 2000 0144 (g) group: 260 c rt 240 c r 3 220 c r ml bin3: bin2: q-1-20 bin1: p-1-20 lsy t676 2 2a temp st r18 demy osram packing sealing label barcode label moisture level 3 floor time 168 hours moisture level 6 floor time 6 hours a) humidity indicator card is > 10% when read at 23 ?c 5 ?c, or reflow, vapor-phase reflow, or equivalent processing (peak package 2. after this bag is opened, devices that will be subjected to infrared 1. shelf life in sealed bag: 24 months at < 40 ?c and < 90% relative humidity (rh). moisture level 5a at factory conditions of (if blank, seal date is identical with date code). a) mounted within b) stored at body temp. 3. devices require baking, before mounting, if: bag seal date moisture level 1 moisture level 2 moisture level 2a 4. if baking is required, b) 2a or 2b is not met. date and time opened: reference ipc/jedec j-std-033 for bake procedure. floor time see below if blank, see bar code label floor time > 1 year floor time 1 year floor time 4 weeks 10% rh. _ < moisture level 4 moisture level 5 ?c). opto semiconductors moisture sensitive this bag contains caution floor time 72 hours floor time 48 hours floor time 24 hours 30 ?c/60% rh. _ < level if blank, see bar code label barcode label 2018-01-15 18 version 1.3 (not for new design) gt daspa1.13
version 1.3 (not for new design) gt daspa1.13 notes hinweise the evaluation of eye safety occurs according to the standard iec 62471:2008 ("photobiological safety of lamps and lamp systems"). within the risk grouping system of this cie standard, the led specified in this data sheet fall into the class moderate risk (exposure time 0.25 s). under real circumstances (for exposure time, eye pupils, observation distance), it is assumed that no endangerment to the eye exists from these devices. as a matter of principle, however, it should be mentioned that intense light sources have a high secondary exposure potential due to their blinding effect. as is also true when viewing other bright light sources (e.g. spotlights), temporary reduction in visual acuity and afterimages can occur, leading to irritation, annoyance, visual impairment, and even accidents, depending on the situation. die bewertung der augensicherheit erfolgt nach dem standard iec 62471:2008 ("photobiological safety of lamps and lamp systems"). im risikogruppensystem dieser cie- norm erfllen die in diesem datenblatt angegebenen leds folgende gruppenanforderung - moderate risk (expositionsdauer 0,25 s). unter realen umst?nden (fr expositionsdauer, augenpupille, betrachtungsabstand) geht damit von diesen bauelementen keinerlei augengef?hrdung aus. grunds?tzlich sollte jedoch erw?hnt werden, dass intensive lichtquellen durch ihre blendwirkung ein hohes sekund?res gefahrenpotenzial besitzen. nach einem blick in eine helle lichtquelle (z.b. spotlights), kann ein tempor?r eingeschr?nktes sehverm?gen oder auch nachbilder zu irritationen, bel?stigungen, beeintr?chtigungen oder sogar unf?llen fhren. this led contains metal materials. corroded metal may lead to a worsening of the optical performance of the led and can in the worst case lead to a failure of the led. do not expose this led to aggressive atmospheres. note, that corrosive gases may as well be emitted from materials close to the led in the final product. diese led enth?lt teilweise metallische bestandteile. korrodiertes metall kann zu einer verschlechterung der optischen eigenschaften und im schlimmsten fall zum ausfall der led fhren. diese led darf aggressiven bedingungen nicht ausgesetzt werden. es ist zu beachten, dass korrosive gase auch von materialien emittiert werden k?nnen, die sich im endprodukt in unmittelbarer umgebung der led befinden. this led is designed for specific/recommended applications only. please consult osram opto semiconductors sales staff in advance for detailed information on other non-recommended applications (e.g. automotive) or please visit www.osram-os.com/appnotes. change management for this component is aligned with the requirements of the lighting market. die led ist ausschlie?lich fr spezifisch empfohlene anwendungen konzipiert. bitte kontaktieren sie das osram opto semiconductors vertriebspersonal fr detailierte informationen ber nicht empfohlene anwendungsbereiche (z.b. automobilbereich). oder besuchen sie www.osram-os.com/appnotes das ?nderungsmanagement dieses bauteils ist an den anforderungen des lichtmarktes ausgerichtet. 2018-01-15 1 9
version 1.3 (not for new design) gt daspa1.13 disclaimer disclaimer language english will prevail in case of any discrepancies or deviations between the two language wordings. attention please! the information describes the type of component and shall not be considered as assured characteristics. terms of delivery and rights to change design reserved. due to technical requirements components may contain dangerous substances. for information on the types in question please contact our sales organization. if printed or downloaded, please find the latest version in the internet. packing please use the recycling operators known to you. we can also help you C get in touch with your nearest sales office. by agreement we will take packing material back, if it is sorted. you must bear the costs of transport. for packing material that is returned to us unsorted or which we are not obliged to accept, we shall have to invoice you for any costs incurred. components used in life-support devices or systems must be expressly authorized for such purpose! critical components* may only be used in life-support devices** or systems with the express written approval of osram os. *) a critical component is a component used in a life-support device or system whose failure can reasonably be expected to cause the failure of that life-support device or system, or to affect its safety or the effectiveness of that device or system. **) life support devices or systems are intended (a) to be implanted in the human body, or (b) to support and/or maintain and sustain human life. if they fail, it is reasonable to assume that the health and the life of the user may be endangered. bei abweichenden angaben im zweisprachigen wortlaut haben die angaben in englischer sprache vorrang. bitte beachten! lieferbedingungen und ?nderungen im design vorbehalten. aufgrund technischer anforderungen k?nnen die bauteile gefahrstoffe enthalten. fr weitere informationen zu gewnschten bauteilen, wenden sie sich bitte an unseren vertrieb. falls sie dieses datenblatt ausgedruckt oder heruntergeladen haben, finden sie die aktuellste version im internet. verpackung benutzen sie bitte die ihnen bekannten recyclingwege. wenn diese nicht bekannt sein sollten, wenden sie sich bitte an das n?chstgelegene vertriebsbro. wir nehmen das verpackungsmaterial zurck, falls dies vereinbart wurde und das material sortiert ist. sie tragen die transportkosten. fr verpackungsmaterial, das unsortiert an uns zurckgeschickt wird oder das wir nicht annehmen mssen, stellen wir ihnen die anfallenden kosten in rechnung. bauteile, die in lebenserhaltenden apparaten und systemen eingesetzt werden, mssen fr diese zwecke ausdrcklich zugelassen sein! kritische bauteile* drfen in lebenserhaltenden apparaten und systemen** nur dann eingesetzt werden, wenn ein schriftliches einverst?ndnis von osram os vorliegt. *) ein kritisches bauteil ist ein bauteil, das in lebenserhaltenden apparaten oder systemen eingesetzt wird und dessen defekt voraussichtlich zu einer fehlfunktion dieses lebenserhaltenden apparates oder systems fhren wird oder die sicherheit oder effektivit?t dieses apparates oder systems beeintr?chtigt. **) lebenserhaltende apparate oder systeme sind fr (a) die implantierung in den menschlichen k?rper oder (b) fr die lebenserhaltung bestimmt. falls sie versagen, kann davon ausgegangen werden, dass die gesundheit und das leben des patienten in gefahr ist. 2018-01-15 20
version 1.3 (not for new design) gt daspa1.13 glossary glossar 1) brightness: brightness values are measured during a current pulse of typically 10 ms, with a tolerance of +/- 7%. 1) helligkeit: helligkeitswerte werden w?hrend eines strompulses mit einer typischen dauer von 10 ms, mit einer genauigkeit von 7% ermittelt. 2) reverse operation: a minimum of 10 hours of reverse operation is permisable in total. 2) betrieb in sperrrichtung: eine gesamtbetriebszeit von wenigstens 10 stunden in sperrrichtung ist gew?hrleistet. forward voltage: the forward voltage is measured during a current pulse duration of typically 1 ms with a tolerance of 0.05v . vorw?rtsspannung: spannungswerte werden mit einer stromeinpr?gedauer von 1 ms, mit einer genauigkeit von 0.05 v ermittelt. typical values: due to the special conditions of the manufacturing processes of led, the typical data or calculated correlations of technical parameters can only reflect statistical figures. these do not necessarily correspond to the actual parameters of each single product, which could differ from the typical data and calculated correlations or the typical characteristic line. if requested, e.g. because of technical improvements, these typ. data will be changed without any further notice. typische werte: wegen der besonderen prozessbedingungen bei der herstellung von led k?nnen typische oder abgeleitete technische parameter nur aufgrund statistischer werte wiedergegeben werden. diese stimmen nicht notwendigerweise mit den werten jedes einzelnen produktes berein, dessen werte sich von typischen und abgeleiteten werten oder typischen kennlinien unterscheiden k?nnen. falls erforderlich, z.b. aufgrund technischer verbesserungen, werden diese typischen werte ohne weitere ankndigung ge?ndert. wavelength: the wavelength is measured at a current pulse of typically 10 ms, with a tolerance of 0.5 nm. wellenl?nge: die wellenl?ge wird w?hrend eines strompulses einer typischen dauer von 10 ms, mit einer genauigkeit von 0.5 nm gemessen. characteristic curve: in the range where the line of the graph is broken, you must expect higher differences between single leds within one packing unit. kennlinien: im gestrichelten bereich der kennlinien muss mit erh?hten abweichungen zwischen leuchtdioden innerhalb einer verpackungseinheit gerechnet werden. tolerance of measure: unless otherwise noted in drawing, tolerances are specified with 0.1 and dimensions are specified in mm. ma?toleranz: wenn in der zeichnung nicht anders angegeben, gilt eine toleranz von 0,1. ma?e werden in mm angegeben. 3 ) 3 ) 4 ) 4 ) 5 ) 5 ) 6 ) 6 ) 7 ) 7 ) 2018-01-15 2 1
version 1.3 (not for new design) gt daspa1.13 published by osram opto semiconductors gmbh leibnizstra?e 4, d-93055 regensburg www.osram-os.com ? all rights reserved. 2018-01-15 22


▲Up To Search▲   

 