|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
ericsson internal product specification 1 (4) prepared (also subject responsible if other) no. sec/s kevin zhou 1/1301-bmr 638/2 uen approved checked date rev reference 2011-02-24 e key features ? full-brick industry standard 116.8 x 61.0 x 12.7 mm (4.6 x 2.4 x 0.50 in.) ? high efficiency, typ. 95 % at 28 vout within 30%-100% load range. ? 1500 vdc input to output isolation ? meets isolation requirements equivalent to basic insulation according to iec/en/ul 60950 ? 2.6 million hours mtbf general characteristics ? excellent thermal performance ? output over voltage protection ? input over voltage protection ? input under voltage shutdown ? over temperature protection ? monotonic startup ? remote sense ? remote control ? over current protection ? output voltage adjust function ? power good function. ? aux voltage 10v, 50ma ? highly automated manufacturing ensures quality ? iso 9001/14001 certified supplier safety approvals design for environment meets requirements in high- temperature lead-free soldering processes. ericsson internal table of contents 1 (1) prepared (also subject responsible if other) no. sec/s kevin zhou 00152-en/lzt146380 uen approved checked date rev reference 2011-03-09 d contents general info rmation ............................................................. 2 safety specifi cation ............................................................. 3 absolute maximu m rating s ............................................................. 4 electrical specification ordering no. 28 v, 21.5a / 600w pky 461 6 pi ......................................... 5 28 v, 25a / 700w pky 4716 pi ......................................... 9 emc specifica tion ........................................................... 13 operating info rmation ........................................................... 14 thermal consid eratio n ........................................................... 16 connectio ns ........................................................... 17 mechanical in formation ........................................................... 18 soldering info rmation ........................................................... 19 delivery info rmation ........................................................... 19 product qualificatio n specificat ion ........................................................... 20 e pky 4000 pi series dc/dc converters, input 36-75 v, output up to 25 a/700 w en/lzt 146 380 r2b march 2011 ? ericsson power modules ab technical speci? cation
ericsson internal product specification 2 (4) prepared (also subject responsible if other) no. sec/s kevin zhou 1/1301-bmr 638/2 uen approved checked date rev reference 2011-02-24 e general information ordering information see contents for individual product ordering numbers. option suffix ordering no. standard non-threaded stand off negative remote control logic m n pky 2616 pi pky 2616 pim pky 2616 pin note: as an example a negative logic with non-threaded stand off product would be pky 2616 pinm. reliability the failure rate ( ) and mean time between failures (mtbf= 1/ ) is calculated at max output power and an operating ambient temperature (t a ) of +40c. ericsson power modules uses telcordia sr-332 issue 2 method 1 to calculate the mean steady-state failure rate and standard deviation ( ). telcordia sr-332 issue 2 also provides techniques to estimate the upper confidence levels of failure rates based on the mean and standard deviation. mean steady-state failure rate, std. deviation, 381nfailures/h 37.3 nfailures/h mtbf (mean value) for the pky series = 2.6 mh. mtbf at 90% confidence level = 2.3 mh compatibility with rohs requirements the products are compatible with the relevant clauses and requirements of the rohs directive 2002/95/ec and have a maximum concentration value of 0.1% by weight in homogeneous materials for le ad, mercury, hexavalent chromium, pbb and pbde and of 0.01% by weight in homogeneous materials for cadmium. exemptions in the rohs directive utilized in ericsson power modules products are found in the statement of compliance document. ericsson power modules fulfills and will continuously fulfill all its obligations under regulation (ec) no 1907/2006 concerning the registration, evaluation, authorization and restriction of chemicals (reach) as they enter into force and is through product materials declarations preparing for the obligations to communicate information on substances in the products. quality statement the products are designed and manufactured in an industrial environment wher e quality systems and methods like iso 9000, six sigma, and spc are intensively in use to boost the continuous improvements strategy. infant mortality or early failures in the products are screened out and they are subjected to an ate-based final test. conservative design rules, design reviews and product qualifications, plus the high competence of an engaged work force, contribute to the high quality of the products. warranty warranty period and conditions are defined in ericsson power modules general terms and conditions of sale. limitation of liability ericsson power modules does not make any other warranties, expressed or imp lied including any warranty of merchantability or fitness for a particular purpose (including, but not limited to, use in life support applications, where malfunctions of product can cause injury to a person?s health or life). ? ericsson ab 2011 the information and specifications in this technical specification is believed to be correct at the time of publication. however, no liability is accepted for inaccuracies, printing errors or for any consequences thereof. ericsson ab reserves the right to change the contents of this technical specification at any time without prior notice. e pky 4000 pi series dc/dc converters, input 36-75 v, output up to 25 a/700 w en/lzt 146 380 r2b march 2011 ? ericsson power modules ab technical speci? cation 2 ericsson internal product specification 3 (4) prepared (also subject responsible if other) no. sec/s kevin zhou 1/1301-bmr 638/2 uen approved checked date rev reference 2011-02-24 e safety specification general in formation ericsson power modules dc/dc converters and dc/dc regulators are designed in accordance with safety standards iec/en/ul 60950-1 safety of information technology equipment . iec/en/ul 60950-1 contains requirements to prevent injury or damage due to the following hazards: ? electrical shock ? energy hazards ? fire ? mechanical and heat hazards ? radiation hazards ? chemical hazards on-board dc/dc converters and dc/dc regulators are defined as component power supplies. as components they cannot fully comply with the provisions of any safety requirements without ?con ditions of acceptability?. clearance between conductors and between conductive parts of the component powe r supply and conductors on the board in the final product must meet the applicable safety requirements. certain conditions of acceptability apply for component power supp lies with limited stand-off (see mechanical information for further information). it is the responsibility of the installer to ensure that the final product housing these components complies with the requirements of all applicable safety standards and regulations for the final product. component power supplies for general use should comply with the requirements in iec 60950-1, en 60950-1 and ul 60950-1 safety of information technology equipment. there are other more product related standards, e.g. ieee 802.3 csma/cd (ethernet) access method , and ets-300132-2 power supply interface at the input to telecommunications equipment, operated by direct current (dc) , but all of these standards are based on iec/en/ul 60950-1 with regards to safety. ericsson power modules dc/dc converters and dc/dc regulators are ul 60950-1 recognized and certified in accordance with en 60950-1. the flammability rating for all construction parts of the products meet requirements for v-0 class material according to iec 60695-11-10, fire hazard testing, test flames ? 50 w horizontal and vertical flame test methods. the products should be installed in the end-use equipment, in accordance with the requirements of the ultimate application. normally the output of the dc/dc converter is considered as selv (safety extra low voltage) and the input source must be isolated by minimum double or reinforced insulation from the primary circuit (ac mains) in accordance with iec/en/ul 60950-1. isolated dc/dc converters it is recommended that a slow blow fuse is to be used at the input of each dc/dc converter. if an input filter is used in the circuit the fuse should be placed in front of the input filter. in the rare event of a component problem that imposes a short circuit on the input source, this fuse will provide the following functions: ? isolate the fault from the input power source so as not to affect the operation of other parts of the system. ? protect the distribution wiring from excessive current and power loss thus preventing hazardous overheating. the galvanic isolation is verified in an electric strength test. the test voltage (v iso ) between input and output is 1500 vdc or 2250 vdc (refer to product specification). 24 v dc systems the input voltage to the dc/dc converter is selv (safety extra low voltage) and the output remains selv under normal and abnormal operating conditions. 48 and 60 v dc systems if the input voltage to the dc/dc converter is 75 vdc or less, then the output remains selv (safety extra low voltage) under normal and abnormal operating conditions. single fault testing in the in put power supply circuit should be performed with the dc/dc converter connected to demonstrate that the input voltage does not exceed 75 vdc. if the input power source circ uit is a dc power system, the source may be treated as a tnv-2 circuit and testing has demonstrated compliance with selv limits in accordance with iec/en/ul60950-1. non-isolated dc/dc regulators the input voltage to the dc/dc regulator is selv (safety extra low voltage) and the output remains selv under normal and abnormal operating conditions. e pky 4000 pi series dc/dc converters, input 36-75 v, output up to 25 a/700 w en/lzt 146 380 r2b march 2011 ? ericsson power modules ab technical speci? cation 3 ericsson internal product specification 1 (10) prepared (also subject responsible if other) no. eseczhw 2/1301-bmr 638/1 uen approved checked date rev reference sec/d (julia you) echwang 2008-10-9 c absolute maximum ratings characteristics min typ max unit t p1 operating temperature (see thermal c onsideration section) -40 +100 c t s storage temperature -55 +125 c v i input voltage -0.5 +100 v v iso isolation voltage (input to output test voltage) 1500 vdc v tr input voltage transient (t p 100 ms) 100 v positive logic option -100 +12 v v rc remote control pin voltage (see operating information section) negative logic option -100 +12 v v adj adjust pin voltage (see operating information section) -0.5 +10 v stress in excess of absolute maximum ratings may cause permanent damage. absolute maximum ratings, sometimes referred to as no destruction limits, are normally tested with one parameter at a time exceeding the limits of output data or electrical characteristics. if exposed to s tress above these limits, function and performance may degrade in an unspecified manner. fundamental circuit diagram e pky 4000 pi series dc/dc converters, input 36-75 v, output up to 25 a/700 w en/lzt 146 380 r2b march 2011 ? ericsson power modules ab technical speci? cation 4 ericsson internal product specification 2 (10) prepared (also subject responsible if other) no. eseczhw 2/1301-bmr 638/1 uen approved checked date rev reference sec/d (julia you) echwang 2008-10-9 c 28v, 21.5a/600w electrical specification pky 4616 pi t p1 = -40 to +100oc, v i = 36 to 75 v, sense pins connected to output pins unless otherwise s pecified under conditions. typical values given at: t p1 = +25c, v i = 53 v i max i o , unless otherwise specified under conditions. additional c in = 220 f.see operating information sect ion for selection of capacitor types. characteristics conditions min typ max unit v i input voltage range 36 75 v v ioff turn-off input voltage decreasing input voltage 32.1 33 34.5 v v ion turn-on input voltage increasing input voltage 33.3 35 35.5 v c i internal input capacitance 35.2 f p o output power 0 600 w 50 % of max i o 95 max i o 93.5 94.5 50 % of max i o , v i = 48 v 95 efficiency max i o , v i = 48 v 93.5 94,5 % p d power dissipation max i o 34.9 41.7 w p li input idling power i o = 0 a, v i = 53 v 5.7 17 w p rc input standby power v i = 53 v (turned off with rc) 0.2 0.3 w f s switching frequency 0-100 % of max i o 145 150 155 khz v iovp input over voltage protection 0-100 % of max i o 80 83 86 v v oi output voltage initial setting and accuracy t p1 = +25c, v i = 53 v, i o = 21.5 a 27.72 28.0 28.28 v output adjust range see operating information 15.0 32.0 v output voltage tolerance band 10-100 % of max i o 27.58 28.42 v idling voltage i o = 0 a 27.44 28.56 v line regulation max i o 20 80 mv v o load regulation v i = 53 v, 1-100 % of max i o 20 80 mv v tr load transient voltage deviation 800 mv t tr load transient recovery time v i = 53 v, load step 25-75-25 % of max i o , di/dt = 1 a/ s 40 s t r ramp-up time (from 10 ? 90 % of v oi ) 10 20 ms t s start-up time (from v i connection to 90 % of v oi ) 10-100 % of max i o 17 20 ms max i o 0.06 m s t f v i shut-down fall time (from v i off to 10 % of v o ) i o = 0 a 2.7 s rc start-up time max i o 15 ms max i o 0.06 ms t rc rc shut-down fall time (from rc off to 10 % of v o ) i o = 0 a 2.7 s i o output current 0 21.5 a i lim current limit threshold t p1 < max t p1 22 27 33.5 a i sc short circuit current t p1 = 25oc, see note 1 27.5 34 a c out recommended capacitive load t p1 = 25oc 0 tbd f v oac output ripple & noise see ripple & noise section, max i o , v oi 180 250 mvp-p ovp over voltage protection t p1 = +25c, v i = 53 v, 0-100 % of max i o 36.6 39 41.4 v v aux auxiliary output voltage t p1 = +25c, v i = 53 v, 0-100 % of max i o 8 10 12 v i aux auxiliary output current max i o , v i = 36-75 v 0 0.05 a note 1:see operating information section. e pky 4000 pi series dc/dc converters, input 36-75 v, output up to 25 a/700 w en/lzt 146 380 r2b march 2011 ? ericsson power modules ab technical speci? cation 5 ericsson internal product specification 3 (10) prepared (also subject responsible if other) no. eseczhw 2/1301-bmr 638/1 uen approved checked date rev reference sec/d (julia you) echwang 2008-10-9 c 28v, 21.5a/600w typical characteristics pky 4616 pi efficiency power dissipation 75 80 85 90 95 100 0 5 10 15 20 [a] [%] 36 v 48 v 53 v 75 v 0 10 20 30 40 50 0 5 10 15 20 [a] [w] 36 v 48 v 53 v 75 v efficiency vs. load current and input voltage at t p1 = +25 c dissipated power vs. load current and input voltage at t p1 = +25c output characteristics current limit characteristics 27.4 27.6 27.8 28.0 28.2 28.4 0 5 10 15 20 [a] [v] 36 v 48 v 53 v 75 v 0.0 7.0 14.0 21.0 28.0 35.0 12 15 18 21 24 27 30 [a] [v] 36 v 48 v 53 v 75 v o utput voltage vs. load current at t p1 = +25c o utput voltage vs. load current at i o > max i o , t p1 = +25c e pky 4000 pi series dc/dc converters, input 36-75 v, output up to 25 a/700 w en/lzt 146 380 r2b march 2011 ? ericsson power modules ab technical speci? cation 6 ericsson internal product specification 4 (10) prepared (also subject responsible if other) no. eseczhw 2/1301-bmr 638/1 uen approved checked date rev reference sec/d (julia you) echwang 2008-10-9 c 28v, 21.5a/600w typical characteristics pky 4616 pi start-up shut-down start-up enabled by connecting v i at: t p1 = +25c, v i = 53 v i o = 21.5 a resistive load. top trace: output voltage 10 v/div. bottom trace: input voltage 20 v/div. time scale: 5 ms/div. shut-down enabled by disconnecting v i at: t p1 = +25c, v i = 53 v, i o = 21.5 a top trace: output voltage 10 v/div. bottom trace: input voltage 20 v/div. time scale: 50 ms/div. output ripple & noise output load transient response output voltage ripple at: t p1 = +25c, v i = 53 v i o = 21.5 a resistive load. trace: output voltage 100 mv/div. time scale: 2 us/div. output voltage response to load current step- change 5.375-16.125-5.375a at: 1 a/us. t p1 =+25c, v i = 53v. trace: output voltage 0.5 v/div. time scale: 0.2 ms/div. output voltage adjust (see operating information) passive adjust the resistor value for an adjusted output voltage is calculated by using the following equations: output voltage adjust upwards, increase: ( ) ? ? ? ? ? ? ?+ ? ? + = % %2100 %5.2 %100 10 o v adj r k output voltage adjust downwards, decrease: ( ) 2 % 100 10 ? = adj r k example: increase 4% =>v out = 29.33 vdc () ? ? ? ? ? ? + ? + 4 42100 45.2 4100 2.2810 k = 2663 k active adjust the output voltage may be adjusted using a current applied to the v adj pin referred to -sense. this current is calculated by using the following equations: output voltage adjust upwards, increase: pin adjust into a 10 x2,5 v -6 =+ 0 %1 output voltage adjust downwards, decrease: pin adjustof out a 10 x2,5 v -6 =? 0 %1 e pky 4000 pi series dc/dc converters, input 36-75 v, output up to 25 a/700 w en/lzt 146 380 r2b march 2011 ? ericsson power modules ab technical speci? cation 7 ericsson internal product specification 5 (10) prepared (also subject responsible if other) no. eseczhw 2/1301-bmr 638/1 uen approved checked date rev reference sec/d (julia you) echwang 2008-10-9 c 28v, 21.5a/600w typical characteristics pky 4616 pi output current derating ? open frame available load current vs. ambient air temperature and airflow at v i = 53 v. see thermal consideration section. output current derating ? base plate thermal resistance ? base plate 0 5 10 15 20 0 20 40 60 80 100 [c] [a] 3.0 m/s 2.0 m/s 1.5 m/s 1.0 m/s 0.5 m/s nat. conv. 0 1 2 3 4 5 0.0 0.5 1.0 1.5 2.0 2.5 3.0 [m/s] [c/w] available load current vs. ambient air temperature and airflow at v i = 53 v. see thermal consideration section. thermal resistance vs. airspeed measured at the converter. tested in wind tunnel with airflow and test conditions as per the thermal consideration section. v i = 53 v. output current derating ? cold wall sealed box tamb 85 c 0 5 10 15 20 25 30 35 0 20 40 60 80 100 [c] a available load current vs. base plate temperature. v i = 53 v. see thermal consideration section. e pky 4000 pi series dc/dc converters, input 36-75 v, output up to 25 a/700 w en/lzt 146 380 r2b march 2011 ? ericsson power modules ab technical speci? cation 8 ericsson internal product specification 6 (10) prepared (also subject responsible if other) no. eseczhw 2/1301-bmr 638/1 uen approved checked date rev reference sec/d (julia you) echwang 2008-10-9 c 28v, 25a/700w electrical specification pky 4716 pi t p1 = -40 to +100oc, v i = 36 to 75 v, sense pins connected to output pins unless otherwise s pecified under conditions. typical values given at: t p1 = +25c, v i = 53 v i max i o , unless otherwise specified under conditions. additional c in = 220 f.see operating information sect ion for selection of capacitor types. characteristics conditions min typ max unit v i input voltage range 36 75 v v ioff turn-off input voltage decreasing input voltage 32.1 33 34.5 v v ion turn-on input voltage increasing input voltage 33.3 35 35.5 v c i internal input capacitance 35.2 f p o output power 0 700 w 50 % of max i o 94.0 max i o 92.5 94.1 50 % of max i o , v i = 48 v 94.3 efficiency max i o , v i = 48 v 93 94.2 % p d power dissipation max i o 44.0 58.9 w p li input idling power i o = 0 a, v i = 53 v 5.7 17 w p rc input standby power v i = 53 v (turned off with rc) 0.2 0.3 w f s switching frequency 0-100 % of max i o 145 150 155 khz v iovp input over voltage protection 0-100 % of max i o 80 83 86 v v oi output voltage initial setting and accuracy t p1 = +25c, v i = 53 v, i o = 21.5 a 27.72 28.0 28.28 v output adjust range see operating information 15.0 32.0 v output voltage tolerance band 10-100 % of max i o 27.58 28.42 v idling voltage i o = 0 a 27.44 28.56 v line regulation max i o 20 80 mv v o load regulation v i = 53 v, 1-100 % of max i o 20 80 mv v tr load transient voltage deviation 550 mv t tr load transient recovery time v i = 53 v, load step 25-75-25 % of max i o , di/dt = 5 a/ s see note 1 20 s t r ramp-up time (from 10 ? 90 % of v oi ) 10 20 ms t s start-up time (from v i connection to 90 % of v oi ) 10-100 % of max i o 17 20 ms max i o 0.06 m s t f v i shut-down fall time (from v i off to 10 % of v o ) i o = 0 a 2.7 s rc start-up time max i o 15 ms max i o 0.06 ms t rc rc shut-down fall time (from rc off to 10 % of v o ) i o = 0 a 2.7 s i o output current 0 25 a i lim current limit threshold t p1 < max t p1 26 32 37.5 a i sc short circuit current t p1 = 25oc, see note 2 32.5 38 a c out recommended capacitive load t p1 = 25oc 0 tbd f v oac output ripple & noise see ripple & noise section, max i o , v oi 200 370 mvp-p ovp over voltage protection t p1 = +25c, v i = 53 v, 0-100 % of max i o 36.6 39 41.4 v v aux auxiliary output voltage t p1 = +25c, v i = 53 v, 0-100 % of max i o 8 10 12 v i aux auxiliary output current max i o , v i = 36-75 v 0 0.05 a note 1: cout used at load transient test; 3300uf(15 x 220 uf)electrolytic capacitors, estimated esr<12 mohm note 2: see operating information section. e pky 4000 pi series dc/dc converters, input 36-75 v, output up to 25 a/700 w en/lzt 146 380 r2b march 2011 ? ericsson power modules ab technical speci? cation 9 ericsson internal product specification 7 (10) prepared (also subject responsible if other) no. eseczhw 2/1301-bmr 638/1 uen approved checked date rev reference sec/d (julia you) echwang 2008-10-9 c 28v, 25a/700w typical characteristics pky 4716 pi efficiency power dissipation 75 80 85 90 95 100 0 5 10 15 20 25 [a] [%] 36 v 48 v 53 v 75 v 0 12 24 36 48 60 0 5 10 15 20 25 [a] [w] 36 v 48 v 53 v 75 v efficiency vs. load current and input voltage at t p1 = +25 c dissipated power vs. load current and input voltage at t p1 = +25c output characteristics current limit characteristics 27.4 27.6 27.8 28.0 28.2 28.4 0 5 10 15 20 25 [a] [v] 36 v 48 v 53 v 75 v 0.0 7.0 14.0 21.0 28.0 35.0 12 16 20 24 28 32 36 [a] [v] 36 v 48 v 53 v 75 v o utput voltage vs. load current at t p1 = +25c o utput voltage vs. load current at i o > max i o , t p1 = +25c e pky 4000 pi series dc/dc converters, input 36-75 v, output up to 25 a/700 w en/lzt 146 380 r2b march 2011 ? ericsson power modules ab technical speci? cation 10 ericsson internal product specification 8 (10) prepared (also subject responsible if other) no. eseczhw 2/1301-bmr 638/1 uen approved checked date rev reference sec/d (julia you) echwang 2008-10-9 c 28v, 25a/700w typical characteristics pky 4716 pi start-up shut-down start-up enabled by connecting v i at: t p1 = +25c, v i = 53 v i o = 25 a resistive load. top trace: output voltage 10 v/div. bottom trace: input voltage 50 v/div. time scale: 10 ms/div. shut-down enabled by disconnecting v i at: t p1 = +25c, v i = 53 v, i o = 25 a top trace: output voltage 10 v/div. bottom trace: input voltage 20 v/div. time scale: 50 ms/div. output ripple & noise output load transient response output voltage ripple at: t p1 = +25c, v i = 53 v i o = 25 a resistive load. trace: output voltage 100 mv/div. time scale: 2 us/div. output voltage response to load current step- change 6.25-18.75-6.25a at: 1 a/us. t p1 =+25c, v i = 53v. top trace: output voltage (1 v/div.). bottom trace: load current (10 a/div.). time scale: (0.1 ms/div.). output voltage adjust (see operating information) passive adjust the resistor value for an adjusted output voltage is calculated by using the following equations: output voltage adjust upwards, increase: ( ) ? ? ? ? ? ? ?+ ? ? + = % %2100 %5.2 %100 10 o v adj r k output voltage adjust downwards, decrease: ( ) 2 % 100 10 ? = adj r k example: increase 4% =>v out = 29.33 vdc () ? ? ? ? ? ? + ? + 4 42100 45.2 4100 2.2810 k = 2663 k active adjust the output voltage may be adjusted using a current applied to the v adj pin referred to -sense. this current is calculated by using the following equations: output voltage adjust upwards, increase: pin adjust into a 10 x2,5 v -6 =+ 0 %1 output voltage adjust downwards, decrease: pin adjustof out a 10 x2,5 v -6 =? 0 %1 e pky 4000 pi series dc/dc converters, input 36-75 v, output up to 25 a/700 w en/lzt 146 380 r2b march 2011 ? ericsson power modules ab technical speci? cation 11 ericsson internal product specification 9 (10) prepared (also subject responsible if other) no. eseczhw 2/1301-bmr 638/1 uen approved checked date rev reference sec/d (julia you) echwang 2008-10-9 c 28v, 25a/700w typical characteristics pky 4716 pi output current derating ? open frame available load current vs. ambient air temperature and airflow at v i = 53 v. see thermal consideration section. output current derating ? base plate thermal resistance ? base plate 0 5 10 15 20 25 0 20 40 60 80 100 [c] [a] 3.0 m/s 2.0 m/s 1.5 m/s 1.0 m/s 0.5 m/s nat. conv. 0 1 2 3 4 5 0.00.51.01.52.02.53.0[m/s] [c/w] available load current vs. ambient air temperature and airflow at v i = 53 v. see thermal consideration section. thermal resistance vs. airspeed measured at the converter. tested in wind tunnel with airflow and test conditions as per the thermal consideration section. v i = 53 v. output current derating ? cold wall sealed box tamb 85 c 0 5 10 15 20 25 30 35 0 20 40 60 80 100 [c] a available load current vs. base plate temperature. v i = 53 v. see thermal consideration section. e pky 4000 pi series dc/dc converters, input 36-75 v, output up to 25 a/700 w en/lzt 146 380 r2b march 2011 ? ericsson power modules ab technical speci? cation 12 ericsson internal product specification 1 (6) prepared (also subject responsible if other) no. eseczhw 3/1301- bmr 638/1 uen approved checked date rev reference sec/d (julia you) echwang 2008-10-9 c pky input 48v output: 700/600w c1 c2 c4 c5 l1 l2 c6 c3 emc specification conducted emi measured according to en55022, cispr 22 and fcc part 15j (see test set-up). see design note 009 for further information. the funda mental switching frequency is 150 khz for pky 4716 pi @ v i = 53 v, max i o . conducted emi input terminal value (typ) emi without filter external filter (class b) required external input filter in order to meet class b in en 55022, cispr 22 and fcc part 15j. filter components: c1, c2, c3 = 5 f (100v, ceramic) c4, c5 = 10nf (2000v, ceramic) c6 = 2x470 f (100v, electrolytic) l1, l2 = 200 h common mode inductor emi with filter test set-up layout recommendations the radiated emi performance of the product will depend on the pcb layout and ground layer design. it is also important to consider the stand-off of the product. if a ground layer is used, it should be connected to the output of the product and the equipment ground or chassis. a ground layer will increase the stray capacitance in the pcb and improve the high frequency emc performance. output ripple and noise output ripple and noise measured according to figure below. see design note 022 for detailed information. output ripple and noise test setup e pky 4000 pi series dc/dc converters, input 36-75 v, output up to 25 a/700 w en/lzt 146 380 r2b march 2011 ? ericsson power modules ab technical speci? cation 13 ericsson internal product specification 2 (6) prepared (also subject responsible if other) no. eseczhw 3/1301- bmr 638/1 uen approved checked date rev reference sec/d (julia you) echwang 2008-10-9 c operating information input voltage the input voltage range 36 to 75vdc meets the requirements of the european telecom standard ets 300 132-2 for normal input voltage range in ?48 and ?60 vdc systems, -40.5 to - 57.0 v and ?50.0 to -72 v respectively. at input voltages exceeding 75 v, the power loss will be higher than at normal input voltage and t p1 must be limited to absolute max +100c. the absolute maximum continuous input voltage is 100 vdc. turn-off input voltage the products monitor the input voltage and will turn on and turn off at predetermined levels. the minimum hysteresis between turn on and turn off input voltage is 1v. remote control (rc) the modules are equipped with a remote on/off control function. an optocoupler in the remote control circuit provides a galvanic isolation (1500v dc minimum) between the remote control pins and the rest of the module?s circuity. positive and negative rc logic options are available. cycling (off and on sequence) of the rc input will restart the module if latched after activa tion of the output overvoltage protection function. the standard version has a ?positiv e logic? remote control and the module will be off until a sufficient current between the rc pins is provided. the figure above presents an example of a circuit which turns on the standard version module. the minimum current to guarantee the activation of the rc input is 1.5ma. the minimum activation voltage over the rc pins is 5.0v. to guarantee that the rc input is not activated, the current must be lower than 50a or the voltage lower than 1.3v. input and output impedance the impedance of both the input source and the load will interact with the impedance of the product. it is important that the input source has low characteristic impedance. the products are designed for stable operation without external capacitors connected to the i nput or output. the performance in some applications can be enhanced by addition of external capacitance as described under external decoupling capacitors. if the input voltage source contai ns significant inductance, the addition of a 220 f/100v capacitor across the input of the product will ensure stable operat ion. the capacitor is not required when powering the product from an input source with an inductance below 10 h. the minimum required capacitance value depends on the output power and the input voltage. the higher output powe r the higher input capacitance is needed. approximately doubled capacitance value is required for a 24 v input voltage source compared to a 48v input voltage source. external decoupling capacitors when powering loads with significant dynamic current requirements, the voltage regulation at the point of load can be improved by addition of decoupling capacitors at the load. the most effective technique is to locate low esr ceramic and electrolytic capacitors as close to the load as possible, using several parallel capacitors to lower the effective esr. the ceramic capacitors will handle high-frequency dynamic load changes while the electrolytic capacitors are used to handle low frequency dynamic load changes. it is equally important to use low resistance and low inductance pcb layouts and cabling. external decoupling capacitors will become part of the product?s control loop. the control loop is optimized for a wide range of external capacitance and the maximum recommended value that could be used without any additional analysis is found in the electrical specification. the esr of the capacitors is a very important parameter. stable operation is guaranteed with a verified esr value of >10 m ? across the output connections. for further information please contact your local ericsson power modules representative. output voltage adjust (v adj ) the products have an output voltage adjust pin (v adj ). this pin can be used to adjust the output voltage above or below output voltage initial setting. when increasing the output voltag e, the voltage at the output pins (including any remote sense compensation ) must be kept below the threshold of the over voltage protection, (ovp) to prevent the product from shutting down. at increased output voltages the maximum power rating of the product remains the same, and the max output current must be decreased correspondingly. when vout is 15v,the max output current is 25a for pky4716,that is to say,the power is 375w. to increase the voltage the resistor should be connected between the v adj pin and +sense pin. the resistor value of the output voltage adjust function is according to information given under the output section for the respective product. to decrease the output voltage, the resistor should be connected between the v adj pin and ?sense pin. e pky 4000 pi series dc/dc converters, input 36-75 v, output up to 25 a/700 w en/lzt 146 380 r2b march 2011 ? ericsson power modules ab technical speci? cation 14 ericsson internal product specification 3 (6) prepared (also subject responsible if other) no. eseczhw 3/1301- bmr 638/1 uen approved checked date rev reference sec/d (julia you) echwang 2008-10-9 c operating information continued parallel operation two or more products may be paralleled for redundancy or increased output power. external active load sharing circuit are recommended to provide the maximum balanced current sharing. remote sense the products have remote sense that can be used to compensate for voltage drops between the output and the point of load. the sense traces should be located close to the pcb ground layer to reduce noise susceptibility. the remote sense circuitry will compensate for up to 10% voltage drop between output pins and the point of load. if the remote sense is not needed +sense should be connected to +out and -sense should be connected to -out. over temperature protection (otp) the product is protected from t hermal overload by an internal over temperature protection circuit (otp). when the pcb temperature (tc reference point) exceeds the otp t threshold value, the output voltage will be gradually decreased. this will decrease the power loss inside the dc/dc power module and protect the module from hazardous temperatures. over voltage protection (ovp) the module includes an output over voltage protection (ovp) function. in the unlikely even t of an output over voltage condition, the ovp circuit will shut down the output voltage. the module will be latched in ?off? state unless either the input voltage or rc input is cycled (switched off and on again). over current protection (ocp) the moduleinclude current limiting circuitry for protection at continuous overload. in case of overload, the ou tput voltage will significantly decrease. the converter will resume normal operation after removal of the overload. t he load distribution should be designed for the maximum specified output short circuit current. pre-bias start-up the module is able to start-up properly under pre-bias output condition. during the start-up, the module does not sink current from an external pre-bi as source present at the output terminals. power good ?power good? function is provided. it is a ?negative logic? open collector output which can drive to ?low? an external circuit when the module operates normally. the pg output will turn level ?high? during fault conditions (e.g. over temperature or over voltage) or when the output is turned off with the remote control. auxiliary output voltage (aux) the module provides a power source referred to ? sense terminal. it is intended to be used as a power source for external circuits, e.g. remote control. the auxiliary output voltage is active whenever an input voltage in range between from 35v to 80v is provided. the nominal auxiliary output voltage is 10v. maximum allowed load is 50ma.the auxiliary output source is not short circuit protected. if it is ov erloaded, the main converter will be switched off. an example of a 5v/45ma power supply driven by the auxiliary output voltage is given in the figure below. thermal consideration e pky 4000 pi series dc/dc converters, input 36-75 v, output up to 25 a/700 w en/lzt 146 380 r2b march 2011 ? ericsson power modules ab technical speci? cation 15 ericsson internal product specification 4 (6) prepared (also subject responsible if other) no. eseczhw 3/1301- bmr 638/1 uen approved checked date rev reference sec/d (julia you) echwang 2008-10-9 c general the products are designed to operate in different thermal environments and sufficient cooling must be provided to ensure reliable operation. cooling of the pky series power modules is achieved mainly by conduction from the baseplate to a heatsink (?cold wall?). the pky series power modules can also operate without a heatsink but sufficient airflow must be provided. the output current derating graph found in the output section for each model provides the available ou tput current vs. ambient air temperature and air velocity at v in = 53 v. the product is tested on a 254 x 254 mm, 35 m (1 oz), 8-layer test board mounted vertically in a wind tunnel with a cross-section of 608 x 203 mm. for products with base plate used in a sealed box/cold wall application, cooling is achieved mainly by conduction through the cold wall. the output curr ent derating graphs are found in the output section for each mode l. the product is tested in a sealed box test set up with ambient temperatures 85c. see design note 028 fo r further details. proper cooling of the product can be verified by measuring the temperature at positions p1, p2, p3, p4 and p5. the temperature at these positio ns should not exceed the max values provided in the table below. the number of points may vary with different thermal design and topology. see design note 019 for further information. position description temp. limit p1 baseplate 100o c p2 m1 120o c p3 pcb 125o c p4 d15 120o c p5 t16 120o c definition of reference temperature t p1 the reference temperature is us ed to monitor the temperature limits of the product. temperatures above maximum t p1 , meassured at the reference point p1 are not allowed and may cause degradation or permanent damage to the product. t p1 is also used to define the temperature range for normal operating conditions. t p1 is defined by the design and used to guarantee safety margins, proper operation and high reliability ot the product. e pky 4000 pi series dc/dc converters, input 36-75 v, output up to 25 a/700 w en/lzt 146 380 r2b march 2011 ? ericsson power modules ab technical speci? cation 16 ericsson internal product specification 5 (6) prepared (also subject responsible if other) no. eseczhw 3/1301- bmr 638/1 uen approved checked date rev reference sec/d (julia you) echwang 2008-10-9 c ambient temperature calculation for products with base plate the maximum allowed ambient temperature can be calculated by using the thermal resistance. 1. the power loss is calculated by using the formula ((1/ ) - 1) output power = power losses (pd). = efficiency of product. e.g. 93.3% = 0.933 2. find the thermal resistance (r th) in the thermal resistance graph found in the output section for each model. note that the thermal resistance can be significantly reduced if a heat sink is mounted on the top of the base plate. calculate the temperature increase ( ? t). ? t = rth x pd 3. max allowed ambient temperature is: max t p1 - ? t. e.g. pky 4716 pi at 2m/s: 1. (( ) - 1) 700 w = 50.27 w 2. 50.27 w 1.1c/w = 55.3c 3. 100 c ? 55.3c = max ambient temperature is 44.7c the actual temperature will be dependent on several factors such as the pcb size, number of layers and direction of airflow. the above calculations of the maximum ambient temperature are based on the thermal re sistance of the pky module without a heatsink. connections pin designation function 1 +on/off remote on/off ?plus? input 2 -on/off remote on/off ?minus? input 3 +in positive input 4 -in negative input 5 aux auxiliary power supply output 6 pwr good power good output 7 optional n/a 8 vadj output voltage adjust 9 +sense positive remote sense 10 -sense negative remote sense 11 -vout negative output voltage 12 -vout negative output voltage 13 -vout negative output voltage 14 +vout positive output voltage 15 +vout positive output voltage 16 +vout positive output voltage 1 0.933 e pky 4000 pi series dc/dc converters, input 36-75 v, output up to 25 a/700 w en/lzt 146 380 r2b march 2011 ? ericsson power modules ab technical speci? cation 17 ericsson internal product spec. mechanical 1 (2) prepared (also subject responsible if other) no. epeihli 4/1301-bmr 638 uen approved checked date rev reference sec/d (julia you) see 1 2008-10-10 b mechanical information e pky 4000 pi series dc/dc converters, input 36-75 v, output up to 25 a/700 w en/lzt 146 380 r2b march 2011 ? ericsson power modules ab technical speci? cation 18 ericsson internal prod. specification mechanical 1 (3) prepared (also subject responsible if other) no. micupez 5/1301-bmr 638 approved checked date rev reference mpm/bk [n. johansson] see 1 2007-06-27 a soldering information ? through hole mounting the product is intended for manual or wave soldering. when wave soldering is used, the temperature on the pins is specified to maximum 270c for maximum 10 seconds. a maximum preheat rate of 4c/s and a temperature of max +150c is suggested. when soldering by hand, care should be taken to avoid direct contact between the hot soldering iron tip and the pins for more than a few seconds in order to prevent overheating. a no-clean flux is recommended to avoid entrapment of cleaning fluids in cavities inside the product or between the product and the host board. the cleanin g residues ma y affect long time reliability and isolation voltage. delivery package information the products are delivered in antistatic trays. tray specifications material antistatic pe foam surface resistance 10 5 < ohm/square < 10 12 bakability the trays are not bakable tray capacity 5 products/tray tray thickness 26.0 mm [1.024 inch] box capacity 5 products (1 full tray/box) tray weight 55 g empty, 880 g full tray e pky 4000 pi series dc/dc converters, input 36-75 v, output up to 25 a/700 w en/lzt 146 380 r2b march 2011 ? ericsson power modules ab technical speci? cation 19 ericsson internal prod. specification mechanical 2 (3) prepared (also subject responsible if other) no. micupez 5/1301-bmr 638 approved checked date rev reference mpm/bk [n. johansson] see 1 2007-06-27 a product qualification specification characteristics external visual inspection ipc-a-610 change of temperature (temperature cycling) iec 60068-2-14 na temperature range number of cycles dwell/transfer time -40 to +100c 1000 15 min/0-1 min cold (in operation) iec 60068-2-1 ad temperature t a duration -45c 72 h damp heat iec 60068-2-67 cy temperature humidity duration +85c 85 % rh 1000 hours dry heat iec 60068-2-2 bd temperature duration +125c 1000 h electrostatic discharge susceptibility iec 61340-3-1, jesd 22-a114 iec 61340-3-2, jesd 22-a115 human body model (hbm) machine model (mm) class 2, 2000 v class 3, 200 v immersion in cleaning so lvents iec 60068-2-45 xa method 2 water glycol ether isopropyl alcohol +55c +35c +35c mechanical shock iec 60068-2-27 e a peak acceleration duration 100 g 6 ms operational life test mil-std-202g method 108a duration 1000 h resistance to soldering heat iec 60068-2-20 tb method 1a solder temperature duration 270c 10-13 s robustness of terminations iec 60068-2-21 test ua1 through hole mount product all leads solderability iec 60068-2-20 test ta 2 preconditioning temperature, snpb eutectic temperature, pb-free steam ageing 235c 245c vibration, broad band random ie c 60068-2-64 fh, method 1 frequency spectral density duration 10 to 500 hz 0.07 g 2 /hz 10 min in each perpendicular direction e pky 4000 pi series dc/dc converters, input 36-75 v, output up to 25 a/700 w en/lzt 146 380 r2b march 2011 ? ericsson power modules ab technical speci? cation 20 |
Price & Availability of PKY4716PI |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |