EFRP-S400 400w redundant power module features: high efficiency R 80% 0~45 working temperature power failure alarm pmbus support general specification input range : 100 to 240 vac, +/-10% power factor: > 0.95 minimum hold up time: 17ms @ 80% load short circuit protection over current protection over voltage protection no load operation mtbf >100,000 hours@25 operating temperature: 0 to 45 operating humidity: 20 to 90 % emi/rfi: ce, fcc class b safety: ul, tuv, ccc, cb, bsmi input and output characteristics note: +3.3v and +5v combined output shall not exceed 200w ripple and noise input output voltage frequency current load +3.3v +5v +12v -12v optional +5vsb(optional) max.load 28a 28a 33a 0.5a 3a 100~240 vac 47~63hz 6~3a min.load 0.1a 0.1a 0.5a 0a 0a output +3.3v +5v +12v -12v(optional) 5vsb(optional) load regulation 5% 5% 5% 10% 5% line regulation 1% 1% 1% 1% 1% ripple & noise 60mv 60mv 120mv 120mv 60mv
mechanical outline dimension: 82mm(w) x 40mm(h) x 250mm(d) outline drawing
|