177 1 2 3 6 5 4 he (high-function economy) type [1-channel (form a) type] with led display 8.8 0.05 .346 .002 6.4 0.05 .252 .002 3.9 0.2 .154 .008 8.8 0.05 .346 .002 6.4 0.05 .252 .002 3.6 0.2 .142 .008 mm inch features ? low on resistance and led display ? same compact size of our conven- tional relays without led display (w) 6.4 (d) 8.8 (h) 3.9 mm (w) 0.252 (d) 0.346 (h) 0.154 inch. ? controls low-level analog signals photomos relays feature extremely low closed-circuit offset voltage to enable control of low level voltage signals or ana- log signals without distortion. ? high sensitivity and low on resistance a stable relay that has a low on resistance of 16 w , no metal contacts, and the ability to control a maximum load current of 0.25 a with an input current of 5 ma. ? low-level off state leakage current in contrast to the ssr with its off state leakage current of several milliamps, the photomos relay features a very small off state leakage current of only 100 pa even at a high load voltage of 400 v. precise fabrication technology problems can be found easily when inspecting the circuit by operation indicating led typical applications ? telephones ? measuring instruments ? game machines ? high-speed inspection machines ? industrial equipment types *indicate the peak ac and dc values. note: for space reasons, the package type indicator "x" and "z" are omitted from the seal. type output rating* part no. packing quantity through hole terminal surface-mount terminal load voltage load current tube packing style tape and reel packing style tube tape and reel picked from the 1/2/3-pin side picked from the 4/5/6-pin side ac/dc type 400 v 150 ma aqv254r aqv254ra AQV254RAX aqv254raz 1 tube contains 50 pcs. 1 batch contains 500 pcs. 1,000 pcs rating 1. absolute maximum ratings (ambient temperature: 25 c 77 f ) item symbol type of connec- tion aqv254r(a) remarks input led forward current i f 25 ma led reverse voltage v r 3 v peak forward current i fp 60 ma f = 100 hz, duty factor = 0.1% power dissipation p in 90 mw output load voltage (peak ac) v l 400 v continuous load current i l a 0.15 a a connection: peak ac, dc b, c connection: dc b 0.18 a c 0.25 a peak load current i peak 0.5 a a connection: 100 ms (1 shot), v l = dc power dissipation p out 360 mw total power dissipation p t 410 mw i/o isolation voltage v iso 1,500 v ac temperature limits operating t opr C40 c to +85 c C40 f to +185 f non-condensing at low temperatures storage t stg C40 c to +100 c C40 f to +212 f photomos relays
aqv254r 178 2. electrical characteristics (ambient temperature: 25 c 77 f ) for type of connection, see page 31. note: recommendable led forward current i f = 5 ma. *turn on/turn off time n for dimensions, see page 27. n for schematic and wiring diagrams, see page 31. n for cautions for use, see page 36. item symbol type of connec- tion aqv254r(a) remarks input led operate current typical i fon 1.0 ma i l = max. maximum 3.0 ma led turn off current minimum i foff 0.4 ma i l = max. typical 0.9 ma led dropout voltage typical v f 2.8 v i f = 5 ma maximum 3.5 v output on resistance typical r on a 12.4 w i f = 5 ma i l = max. within 1 s on time maximum 16 w typical r on b 6.2 w i f = 5 ma i l = max. within 1 s on time maximum 8 w typical r on c 3.1 w i f = 5 ma i l = max. within 1 s on time maximum 4 w off state leakage current maximum i leak 1 m a i f = 0 v l = max. transfer characteristics switching speed turn on time* typical t on 0.8 ms i f = 5 ma i l = max. maximum 2 ms turn off time* typical t off 0.05 ms i f = 5 ma i l = max. maximum 0.2 ms i/o capacitance typical c iso 1.3 pf f = 1 mhz v b = 0 maximum 3 pf initial i/o isolation resistance minimum r iso 1,000 m w 500 v dc ton input output 10% 90% toff reference data 1. input current vs. ambient temperature char- acteristics allowable ambient temperature: C40 c to +85 c C40 f to +185 f ; type of connection: a 2. load current vs. ambient temperature char- acteristics allowable ambient temperature: C40 c to +85 c C40 f to +185 f ; type of connection: a 3. on resistance vs. ambient temperature char- acteristics measured portion: between terminals 4 and 6; led current: 5 ma; load voltage: 400 v (dc); continuous load current: 150 ma (dc) 50 40 30 20 10 0 0 ?0 ?0 20 40 60 8085 100 ambient temperautre, c input current, ma 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 0 ?0 20 40 60 8085 100 ?0 ambient temperautre, c load curret, a 20 18 16 14 12 10 8 6 4 2 0 0 ?0 20 40 60 8085 ?0 ambient temperature, c on resistance,
aqv254r 179 4. turn on time vs. ambient temperature char- acteristics led current: 5 ma; load voltage: 400 v (dc); continuous load current: 150 ma (dc) 5. turn off time vs. ambient temperature char- acteristics led current: 5 ma; load voltage: 400 v (dc); continuous load current: 150 ma (dc) 6. led operate vs. ambient temperature char- acteristics load voltage: 400 v (dc); continuous load current: 150 ma (dc) 4 3 2 1 0 0 ?0 20 40 60 8085 ?0 ambient temperature, c turn on time, ms 0.4 0.3 0.2 0.1 0 0 ?0 20 40 60 8085 ?0 ambient temperature, c turn off time, ms 4 3 2 1 0 0 ?0 20 40 60 8085 ?0 ambient temperature, c led operate current, ma 7. led turn off current vs. ambient temperature characteristics load voltage: 400 v (dc); continuous load current: 150 ma (dc) 8. led dropout voltage vs. ambient tempera- ture characteristics led current: 5 to 25 ma 9. voltage vs. current characteristics of output at mos portion measured portion: between terminals 4 and 6; ambient temperature: 25 c 77 f 4 3 2 1 0 0 ?0 20 40 60 8085 ?0 ambient temperature, c led turn off current, ma 3.4 3.2 3.0 2.8 2.6 0 0 ?0 20 40 60 8085 ?0 i f =10ma i f =25ma i f =5ma ambient temperature, c led dropout voltage, v ?.4 ?.0 ?.6 ?.2 ?.8 ?.4 ?.6 0.6 0.5 0.4 0.3 0.2 0.1 current, a voltege, v ?.1 ?.2 ?.3 ?.4 ?.5 0.4 0.8 1.2 1.6 2.0 2.4 0 10. off state leakage current measured portion: between terminals 4 and 6; ambient temperature: 25 c 77 f 11. led forward current vs. turn on time char- acteristics measured portion: between terminals 4 and 6; load voltage: 400 v (dc); continuous load current: 150 ma (dc); ambient temperature: 25 c 77 f 12. led forward current vs. turn off time char- acteristics measured portion: between terminals 4 and 6; load voltage: 400 v (dc); continuous load current: 150 ma (dc); ambient temperature: 25 c 77 f 10 ? 10 ? 10 ? 10 ?2 0 20 40 60 80 100 load voltage, v off state leakage current, a 3.0 2.5 2.0 1.5 1.0 0.5 0 10 20 30 40 50 60 0 led current, ma turn on time, ms 0.12 0.10 0.08 0.06 0.04 0.02 0 10 20 30 40 50 60 0 led current, ma turn off time, ms 13. applied voltage vs. output capacitance characteristics measured portion: between terminals 4 and 6; frequency: 1 mhz; ambient temperature: 25 c 77 f 600 500 400 300 200 100 0 0102030405060 applied voltage, v output capacitance, pf 5/7/2001 all rights reserved, ? copyright matsushita electric works, ltd. go to online catalog
|