www.micropowerdirect.com micropower direct 292 page street suite d stoughton, ma 02072 usa t: (781) 344-8226 f: (781) 344-8481 e: sales@micropowerdirect.com w: www.micropowerdirect.com input parameter conditions min. typ. max. units input voltage range 85 264 vac 120 370 vdc input frequency 47 440 hz inrush current, see note 2 115 vac 30 a pk 230 vac 60 no load power consumption 0.3 w output parameter conditions min. typ. max. units output voltage accuracy ?.0 % line regulation v in = min to max ?.5 % load regulation, i o = min to max single output ?.0 % dual output ?.0 ripple & noise (20 mhz), see note 3 5.0 vdc output 1.5 1.8 %v p-p of v o all other outputs 1.0 1.3 hold-up time 115 vac, 60 hz 25 ms 230 vac, 50 hz 80 temperature coef cient ?.02 %/? over voltage protection see note 4 120 % of v o overshoot 5% overload protection see note 5 105 % i nom over temperature protection see note 6 90 ? short circuit protection, see note 7 continuous (autorecovery) general parameter conditions min. typ. max. units isolation voltage (reinforced) input to output 4,000 vac rms leakage current 80 a isolation resistance 500 vdc 1,000 m switching frequency 130 khz environmental parameter standard criterea level radiated emissions en 55014, en 55024 class b conducted emissions en 55022 class b esd en 61000-4-2 a ? kv air a ? kv contact rs en 61000-4-3 a 10 v/m eft en 61000-4-4 a ? kv surge en 61000-4-5 a ? kv cs en 61000-4-6 a 10 vrms pfm en 61000-4-8 a 30 a/m voltage dips en 61000-4-11 a 30% 10 ms interruptions en 61000-4-11 b 95% 5,000 ms environmental parameter conditions min. typ. max. units operating temperature range ambient -40 +25 +80 ? storage temperature range -40 +95 ? cooling, see note 8 free air convection (see derating curve) humidity rh, non-condensing 95 % physical case size see mechanical diagrams (pages 3 & 4) case material non-conductive plastic resin (ul94-v0) reliability speci cations parameter conditions min. typ. max. units mtbf mil hdbk 217f, 25?, gnd benign 200 khours safety standards ul 60950, en 60950 safety class iec 60536 class ii medical approved, 40w single & dual output ac/dc power supplies mpm-40m series electrical speci cations speci cations typical @ +25?, 230 vac input voltage & rated output current, unless otherwise noted. speci cations subject to change without notice. key features: 40w output power en 60601-1 3 rd edition universal 85-264 vac input en 60950 approved reinforced insulation meets iec safety class ii low leakage current single and dual outputs meets ul 508 chassis mount models & din rail mount option available!
292 page street ste d stoughton, ma 02072 tel: (781) 344-8226 fax: (781) 344-8481 e-mail: sales@micropowerdirect.com www.micropowerdirect.com model selection guide model number input current (ma typ) output capacitive load (?, max) ef ciency (%, typ) voltage (vdc) current (a) 115 vac 230 vac max. min. mpm-40ms-05xx 716 429 5.0 8.00 0.00 8,000 81 mpm-40ms-12xx 689 414 12.0 3.33 0.00 3,900 84 mpm-40ms-15xx 680 408 15.0 2.66 0.00 3,900 85 mpm-40ms-24xx 687 413 24.0 1.66 0.00 680 84 mpm-40md-12xx 687 413 ?2.0 ?.66 0.00 1,500 84 MPM-40MD-15XX 680 408 ?5.0 ?.33 0.00 1,000 85 derating curve other outputs may be available contact the factory for details at: sales@micropowerdirect.com model number notes: 1. the speci ed maximum capacitive load is for each output. 2 . inrush current is given for a cold start at 25?. 3. ripple and noise is measured with a 0.1 f/50v mlcc and a 1 f/50v aluminum electrolytic connected between the +v out and -v out pins for single output models or from each output to common for dual output models. 4. over voltage protection is provided by a zener diode clamp. 5. output overload protection is provided by a ?iccup mode circuit with auto-recovery. a long-term overload could damage the unit. 6. the unit will shutdown at 90?. it will recover automatically at about 67 ?. 7. output short circuit protection is provided by a ?iccup mode circuit. the unit recovers automatically when the fault condition is removed. 8. free air (natural) convection is about 20 lfm, it is not equal to ?till air. 9. operation at no-load will not damage these units. however, they may not meet all speci cations. 10. it is recommended that an external slow blow fuse also be used on the input for protection. chassis mount & din rail all models of the mpm-40mx series are available in an encapsulated package that can be mounted to a chassis or cabinet and connected with ying leads. to order the unit in this package, add a ?m to the end of the product number. this package can also be adapted for use with a standard din rail by install- ing a simple adapter kit. as illustrated at right, this din rail kit consists of a base plate, a din rail bracket and the necessary hardware. for the mpm-40mx series the din rail kit is: ac-din-02.
micropower direct 292 page street ste d stoughton, ma 02072 tel: (781) 344-8226 fax: (781) 344-8481 e-mail: sales@micropowerdirect.com www.micropowerdirect.com mechanical dimensions mechanical dimensions , chassis mount pin single dual 1 ac neutral ac neutral 2 ac line ac line 3+v out +v out 5-v out common 7nc -v out nc = no connection pin connections pin single dual 1 ac neutral ac neutral 2 ac line ac line 3+v out +v out 4 nc nc 5-v out common 6nc nc 7nc -v out nc = no connection pin connections notes: all dimensions are typical in inches (mm) tolerance x.xx = 0.02 ( 0.5) notes: all dimensions are typical in inches (mm) tolerance x.xx = 0.02 ( 0.5) for the ?hassis mount?package, add suf x ?m to the model number (i.e. mpm-40ms-12cm)
micropower direct we power your success - for less! 292 page street ste d stoughton, ma 02072 tel: (781) 344-8226 fax: (781) 344-8481 e-mail: sales@micropowerdirect.com www.micropowerdirect.com mechanical dimensions , din rail mount pin single dual 1 ac neutral ac neutral 2 ac line ac line 3+v out +v out 4 nc nc 5-v out common 6nc nc 7nc -v out nc = no connection pin connections notes: all dimensions are typical in inches (mm) tolerance x.xx = 0.02 ( 0.5) din rail mounting all chassis mount mpm-40mx models are easily adapted for use with a standard 35 mm din rail by installing a simple adapter kit. the din rail kit consists of a base plate, a din rail bracket and the necessary hardware. mechanical dimen- sions for an mpm-40mx assembly with the din rail option are shown below. for the mpm-40mx series the din rail kit is: ac-din-02.
|