  taf150 1 www.pduke.com 2014/7/30 taf150 series 2 x 4 inch ac-dc power supplies universal input range up to 150watts features applications ? low standby power consumption under 0.3 watt ? wide input voltage range 85 to 264vac, 47 to 63hz ? active power factor correction ? built-in emi filter ? output voltage adjustable ? open frame dimensions 2.00 x 4.00 x 1.16 inch ? 3000vac input to output reinforced insulation ? protection type class i and class ii ? low leakage current under 300 a ? operating altitude 5000m ? 3 year warranty ? ul60950-1, en60950-1, & iec60950-1 safety approvals ? ce marked ? compliant to rohs ii & reach ? wireless network ? telecom/datacom ? industry control system ? measurement equipment ? semiconductor equipment 3000vac isolation ocp scp ovp low standby power technical specification all specifications are typical at 230vac input, full load and 25 otherwise noted input range output voltage output current @ forced air cooling 50 ta with 10cfm output current @ natural convection 50 ta efficiency model number vac vdc a a % taf150us12 85 ~ 264 12 12.50 8.33 91 taf150us15 85 ~ 264 15 10.00 7.33 92 taf150us24 85 ~ 264 24 6.25 4.58 92 taf150us28 85 ~ 264 28 5.36 3.92 92 taf150us36 85 ~ 264 36 4.17 3.05 92 taf150us48 85 ~ 264 48 3.13 2.08 92 part number structure t a f 150 u s 12 - application package dimension output input output output protection option code code power voltage quantity voltage type (w) (vac) (vdc) industry a: open type u: universal s: single 12: 12v n o suffix: class i f: external fan application u: u chassis type 85 ~ 264vac 15: 15v b: class ii (e type only) e: enclosed type 24: 24v d: din rail (e type only) 28: 28v 36: 36v 48: 48v
taf150 2 www.pduke.com 2014/7/30 input specifications parameter conditions min. typ. max. unit operating input voltage range ac input dc input 85 120 264 370 vac vdc input frequency ac input 47 63 hz input current 115vac and full load 230vac and full load 1.7 0.8 a no load input power 230vac 230vac t e f -f 0.6 0.3 watts leakage current 264vac 300 a power factor 0.95 start up time 1000 ms rise time 20 ms hold up time 115vac and full load 16 ms input inrush current 230vac 100 a input protection internal fuse t3.15a/250vac output specifications parameter conditions min. typ. max. unit output power forced air cooling with 10cfm natural convection for 15vout, 24vout, 28vout, 36vo ut natural convection for 12vout, 48vout 150 110 100 watts initial set voltage accuracy 230vac and full load -1.0 +1.0 % line regulation low line to high line at full load -0.2 +0.2 % load regulation no load to full load 10% load to 90% load -0.5 -0.4 +0.5 +0.4 % voltage adjustability -10 +10 % minimum load 0 % ripple and noise measured by 20mhz bandwidth with a 1 f/25v 1206 x7r mlcc with a 1 f/25v 1206 x7r mlcc with a 1 f/50v 1206 x7r mlcc with a 1 f/50v 1206 x7r mlcc with a 1 f/50v 1206 x7r mlcc with a 0.1 f/100v 1206 x7r mlcc 12vout 15vout 24vout 28vout 36vout 48vout 120 150 220 220 250 250 mvp-p temperature coefficient -0.02 +0.02 %/ transient response load step form 50 ~ 75% change at 2.5a/ s peak deviation recovery time 500 3 % vout s over voltage protection % of vout(nom); latch mode 115 135 % over load protection % of iout rated; hiccup mode 115 150 % short circuit protection continuous, automatics recovery fan power supply 12v at 500ma general specifications parameter conditions min. typ. max. unit isolation voltage 1 minute (reinforced insulation) input to output input (output) to f.g. 3000 1500 vac isolation resistance 500vdc 0.1 g  switching frequency 60 khz safety approvals ul60950-1 en60950-1 iec60950-1 weight taf tuf tef tdf 187g (6.60oz) 235g (8.29oz) 256g (9.03oz) 278g (9.81oz) mtbf mil-hdbk-217f ta=25 , full load 7.861 x 10 5 hrs environmental specifications parameter conditions min. typ. max. unit operating ambient temperature forced air cooling: 1 50w with 10cfm with derating -40 +80 natural convection: 100 ~ 110w -40 start up : 80% load,max. @ vin > 100vac -40 start up : 100% load,max. @ vin > 200vac with derating -40 +80 storage temperature range -40 +85 operating altitude 5000 m thermal shock mil-std-810f shock iec68-2-27 vibration iec68-2-6 relative humidity non-condensing 5% to 95% rh
taf150 3 www.pduke.com 2014/7/30 emc specifications parameter conditions level emi en55011, en55022 and fcc part 15 conducted radiated class b class a harmonic currents en61000-3-2 full load class a and d voltage flicker en61000-3-3 esd en61000-4-2 air 8kv and contact 6kv perf. criteria a radiated immunity en61000-4-3 20 v/m perf. criteria a fast transient en61000-4-4 2kv perf. criteria a surge en61000-4-5 dm 1kv and cm 2kv perf. criteria a conducted immunity en61000-4-6 20 vr.m.s perf. criteria a power frequency magnetic field en61000-4-8 10 a/m perf. criteria a dip and interruptions en61000-4-11 and en55024 characteristic curve derating curve vs. ambient temperature t f150 derating curve vs. input voltage t f150 efficiency vs. output load t f150us24 efficiency vs. input voltage t f150us24
taf150 4 www.pduke.com 2014/7/30 mechanical drawing t a f open type t d f din rail type t e f enclosed type t u f u chassis type 1. all dimensions in inch (mm) 2. tolerance : x.xx0.02 (x.x0.5) x.xxx0.01 (x.x x0.25) 3. m30.5 screw locked torque max 5kgf.cm/0.49n.m connectors connections con1 ? input connector pin 1 line pin 3 neutral mates with jst housing : vhr-3n jst crimp terminals : svh-21t-p1.1 mounting holes marked with must be connected to safety earth for class i appli cation con2 ? output connector pin 1,2,3 -vout pin 4,5,6 +vout mates with jst housing : vhr-6n jst crimp terminals : svh-21t-p1.1 con3 ? fan connector pin 1 -fan pin 2 +fan mates with molex housing : 22-01-1022 molex crimp terminals : 2759
taf150 5 www.pduke.com 2014/7/30 mechanical drawing t e f - f enclosed type with fan t d f - f din rail type with fan 1. all dimensions in inch (mm) 2. tolerance : x.xx0.02 (x.x0.5) x.xxx0.01 (x.x x0.25) 3. m30.5 screw locked torque max 5kgf.cm/0.49n.m connectors connections con1 ? input connector pin 1 line pin 3 neutral mates with jst housing : vhr-3n jst crimp terminals : svh-21t-p1.1 mounting holes marked with must be connected to safety earth for class i appli cation con2 ? output connector pin 1,2,3 -vout pin 4,5,6 +vout mates with jst housing : vhr-6n jst crimp terminals : svh-21t-p1.1 con3 ? fan connector pin 1 -fan pin 2 +fan mates with molex housing : 22-01-1022 molex crimp terminals : 2759


▲Up To Search▲   

 
Price & Availability of TEF150-14

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X