the copyright and authority for the interpretation of the products are reserved by mornsun trx00pi 2013.07.01-a/3 page 1 of 3 programmable rtds detection type isolation barrier trx00pi series part number system programmable symbol serial number channel configuration rs485 trx00pi transducer type features three-port isolation ( input, output and power supply) high accuracy (0.1% f.s.) ( the smaller the input range is, the lower its accuracy is ) isolation voltage (2.5kvac/60s) low temperature drift (50ppm/ c) digital bus (rs485) input / output range programmable high reliability(mtbf>500,000 hours) general description the signal generated by the two-wire or three-wire rtds in the application field is picked up by this product, and converted to the standard analog current or voltage signal which is isolated with application field, and transmitted to the control cabinet. the product is armed with rs485 digital bus interface, which makes network configuration and the input or output configuration possible in plc/dcs system. it is an intelligent product. one independent power supply is required. moreover, within the product power supply, input and output are mutually isolated. and have temperature over limit alarm and off-line alarm field devices connected with this product: two-wire, three-wire rtds (not to be used in intrinsically safe area); selection guide output type 1 in 1 out 2 in 2 out 1 in 2 out current output TR100PI tr200pi tr600pi input signal programmable(2-wire system or 3-wire system input) description trx00pi signal type range the minimum range pt100 -200~+850 50 cu50 -50~+150 50 input thermal resistance signal cu100 -50~+150 50 current output 4~20ma output signal current output 0~20ma note: 1.the initial setting of the product is signal type:pt100, measurement range: -200~+800 ,, minimum range: 50 , current output: 4~20ma.. customers can choose signal type and range, or program with the programming software. (which can be downloaded at www.mornsun.cn ).modifying is also acceptable if there are special requirements. 2. if you need, you can get the isolator's usb adapter which p/n is t-02 free of charge. electrical characteristics input range 18~36vdc (typ. : 24vdc) 1 in 1 out abou1.5w input power 1 in 2 out, 2 in 2 out abou2.0w power supply parameter power protection reverse protection application field input signal refer to product overview output signal refer to product overview load 500 (@maximum output current) communication interface rs485 control cabinet communication protocol refer to mornsun science and technology modbus protocol rule transmission characteristics offset 0.1%f.s. gain error 0.1%f.s. (maximum input range) accuracy 0.1%f.s. (maximum input range) temperature drift 0.0050%f.s./ c (-25 ~ +71 c)
the copyright and authority for the interpretation of the products are reserved by mornsun trx00pi 2013.07.01-a/3 page 2 of 3 isolation characteristics 2.5kvac between input channels & power supply 2.5kvac between input channels & output channels 1.5kvdc between output channels & power supply galvanic isolation 1.5kvdc between output channels (for multi-channel products) test conditions: testing for 1minute, humidity < 70%, leakage current < 1ma alarm functions off-line alarm channel 1 off-line, led o flash with one pulse; channel 2 off-line, led o flash with dual pulses; channel 1 & 2 all off-line, led o is always on; when one of two channels is off-line, correspondingly, its output current is about 23ma. upper limit alarm channel 1 upper limit alarm, led h flash with one pulse; channel 2 upper limit alarm, led h flash with dual pulses; channel 1 & 2 all upper limit alarm , led h is always on; when one of two channels is upper limit alarm, correspondingly, its output current is about 22ma. lower limit alarm channel 1 lower limit alarm, led l flash with one pulse; channel 2 lower limit alarm, led l flash with dual pulses; channel 1 & 2 all lower limit alarm , led l is always on; when one of two channels is upper limit alarm, correspondingly, its output curren t is about 3ma (4~20ma) or 21ma(0~20ma). note: if the output is voltage, output voltage for alarm is linear relation to current. for example, for 4~20ma output, its respective alarm value is 22ma, 21ma, 3ma(or 0ma), as is stated above, for 2~10v output, its respective alarm value is 11v, 10.5v, 1.5v(or 0v), and suchlike. other characteristics operation temperature: -25 ~ +71 c ambient temperature transport and storage temperature: - 50 ~ +105 c package 35mm din-rail package, pluggable connection terminal, thickness 22.5mm, plastic ul94-v0 safety class ip20(iec60529 / en60529) weight 1 input 2 output&2 input 2 output about 128g;1input 1output about 100g note: 1. all specifications measured at ta=25 c, humidity<75%, nominal input voltage and rated output load unless otherwise specified. 2. only typical models listed, specifications of custom product may be different. please contact our service people directly for certain conditions. 3. communication protocol details refer to mornsun science and technology modbus protocol rule . 4. the mornsun safety barrier configuration software can be downloaded free from the mornsun homepage www.mornsun.cn or you can contact us to get it. connection 1. removable terminal; 2. cross section area of wiring: 0.5mm 2 2.5 mm 2 ; 3. the length of bare wire is about 8mm, locked up by the m3 bolt. application in industry in so many occasions, isolation barriers should not be installed in intrinsically safe area. selection guidelines for isolation barrier 1. pay more attention to output resistance and loop resistance and make sure the barrier output voltage meets the minimum operation voltage demand of field device. 2. select suitable isolation barrier which matches the field device according to its power polarity, signal type and transmission mode. 3. much more protection is required, which can avoid the influence of the leakage current generated by isolation barrier on field device. operation notes 1. please read the user manual carefully before using. if any questions please contact our technical support department. 2. please do not use this product in hazardous area. 3. the power supply of this product should be 24vdc power source. it is forbidden to use 220vac power supply. 4. to avoid invalid explosion protection function, or any failure, users disassemble this product is forbidden. application circuit diagram 9 10 11 13 14 15 4~20ma 4~20ma 18~36vdc + + - - application field control cabinet 9 10 11 13 14 15 5 6 1 7 2 8 3 4 485a rl rl channel 2 channel 1 485b + - channel 1 channel 2 2w 3w
the copyright and authority for the interpretation of the products are reserved by mornsun trx00pi 2013.07.01-a/3 page 3 of 3 note: 1. this diagram is for 2 channels input & 2 channels output model only. channel 2 of input end is no connection for 1 channel input & 2 channels output model, and channel 2 of input and output end is no connection for 1 channel input & 1 channel output model. 2. for three-wire rtds signal input, make sure the equal resistance of three wires as possible as you can; 3. for two-wire rtds signal input, terminal 10 and 11, 14 and 15 must be short connected. installation & disassembly installation din35mm standard rail installation: 1.insert the top of the instrument card in the rail; 2.push the bottom of the instrument into the rail. disassembly 1.insert a screwdriver between the bottom of the card lock and the rail; 2.pull up the screwdriver and press the card lock downwards; 3.pull the instrument out of the rail. 1 2 3 packaging dimension & packaging diagram note: 1. all specifications are measured at ta=25 c, humidity<75%, nominal input voltage and rated output load unless otherwise specified. 2. in this datasheet, all the test setup and methods are based on our corporate standards. 3. all characteristics are meant for listed model, non-standard models may perform differently, you can contact mornsun fae for more details. 4. contact us for your specific requirement. 5. specifications are subject to change without prior notice. mornsun science & technology co.,ltd. address: no. 5, kehui st. 1, kehui development center, science ave., guangzhou science city, luogang district, guangzhou,p.r.china. tel: 86-20-38601850 fax:86-20-38601272 e-mail: info@mornsun.cn http://www.mornsun-power.com
|