Part Number Hot Search : 
BUW133A RKP412KS 5201A 70551 ADVANCE 124141 0169A 9510F13
Product Description
Full Text Search
 

To Download FT-NFM2S4 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  123 fiber sensors laser sensors photoelectric sensors micro photoelectric sensors area sensors safety components pressure sensors inductive proximity sensors particular use sensors sensor options wire-saving systems measurement sensors static control devices laser markers selection guide fiber sensor amplifiers fx-300 fx-100 fibers ft / fd / fr fx-410 fx-311 fx-11a fx-301-f other products fiber sensors fx-100 fiber sensor ampli ers related information digital fiber sensor fx-100 series glossary of terms / general precautions ... p.983~ / p.986~ taking ber sensors to the next level conforming to emc directive the dual digital display allows users to check both the threshold value and incident light intensity at the same time, allowing for clear and intuitive control of the sensor?s functions. the threshold value can be adjusted simply by pressing the (up) key or the (down) key, so that the output operation can be controlled with high precision, directly from the run mode. setup is made simple, using a dual digital display commercially-available connectors are used so that lead time and spare part numbers can both be reduced the connectors used are commercially-available connectors, so that processing costs and lead time required for carrying out processing after purchase of the sensors can be greatly reduced. the same connection parts as the dp-100 series of digital pressure sensors and the pm-64 series of micro photoelectric sensors can be used. fiber selection ................................. p.63~ general terms and conditions ............. p.1 sensor selection guide ........p.11~ / p.61~ pnp output type available timer light intensity monitor interference prevention a utomatic sensitivity setting test input conventional (cable type) from now on (built-in connector type) using cables with connectors 1 sensor purchase and preparation 2 harness processing by outside order 1 sensor purchase and preparation 2 harness processing by outside order 1 purchase of sensors and cable with connectors conventional lead time customer harness processor customer customer harness processor sensor preparation sensor preparation harness processing harness processing sensor installation reduced sensor installation reduced sensor preparation sensor installation lead time from now on lead time further reduced reduced lead time harness processing by outside order after sensor preparation harness processing by outside order commercially-available press- t connectors are used, so that the processing costs for connection cables can be greatly reduced. threshold value incident light intensity connection with a commercially-available connector http://www.sunx.com sunx website
digital fiber sensor fx-100 series 124 fiber sensors laser sensors photoelectric sensors micro photoelectric sensors area sensors safety components pressure sensors inductive proximity sensors particular use sensors sensor options wire-saving systems measurement sensors static control devices laser markers selection guide fiber sensor amplifiers fx-300 fx-100 fibers ft / fd / fr fx-410 fx-311 fx-11a fx-301-f other products fiber sensors fx-100 fiber sensor ampli ers the sensor is very slim, yet equipped with a dual digital display. both space saving and ease of use have been achieved. a stable amount of emitted light is ensured due to control of the aging of the emitting element to the maximum limit. saving-space with a width of 9 mm 0.354 in equipped with a four-chemical emitting element 9 mm 0.354 in quick code input function [run mode] sensor settings can be made simply by selecting preset values. a three level navigation structure provides easy access to the sensor?s functions, from basic to advanced setting details are divided into three levels for simple operation, so that settings for normal operation are made in ?run mode?, basic settings are made in ?set mode?, and advanced functions are set in ?pro mode?. this makes con guration much easier to understand and carry out. functions used during normal operation [function table] ? changing threshold values ? key lock ? quick settings ? code settings run mode set mode functions used when initializing the sensor and carrying out maintenance [function table] ? teaching ? l-on / d-on setting ? timer setting ? attenuation function ? interference prevention function pro mode equipped with a full complement of digital fiber sensor functions [function table] ? shift ? external input ? reset ? geta ? eco ? display reversing ? surplus value display ? copy ? threshold tracking run mode set mode pro mode simple setting special and detailed setting smooth support via telephone [run mode] con rmation can be carried out smoothly via telephone by simply quoting numbers. this can be of great assistance when dealing with foreign country customers. no. output operation light-emitting amount selection timer dark-on off none dark-on on none dark-on off off-delay 10 ms dark-on on off-delay 10 ms light-on on on-delay 40 ms light-on off on-delay 40 ms light-on on on-delay 10 ms light-on off on-delay 10 ms quick setting numbers (summary) p.138 dimensions p.136 ~ precautions for proper use p.135 ~ sensing characteristics p.134 ~ i/o circuit diagrams p.133 specifications p.128 ~ list of fibers p.126 ~ order guide [stable sensing comparison] three-chemical emitting element fx-100 light-emitting amount time long-term stability
125 digital fiber sensor fx-100 series fiber sensors laser sensors photoelectric sensors micro photoelectric sensors area sensors safety components pressure sensors inductive proximity sensors particular use sensors sensor options wire-saving systems measurement sensors static control devices laser markers fiber sensors selection guide fiber sensor amplifiers fx-300 fx-100 fibers ft / fd / fr fx-410 fx-311 fx-11a fx-301-f other products fx-100 fiber sensor ampli ers the emitted light and output indicator flash at the same frequency. attenuation function [set mode] if the light receiving level becomes saturated when sensing over short distances or when sensing transparent objects or minute objects, the light emitting amount can be reduced so that stable sensing can be provided without needing to change the response time. teaching using on / off buttons [set mode] simply press the on button when an object is present and off when it is not. there is no need to switch settings or make judgments between light-on ( ) and dark-on ( ). interference prevention function [set mode] the emission frequencies can be set separately for each unit in order to avoid interference. the emitted light ashes while setting is in progress, so that you can see at a glance which ber sensor is currently being set. in addition, this interference prevention is not done by using optical communication. this means that there is no need to place the ampli ers close together like there was before, and so the ampli ers can be set up apart from each other. fx-101 : interference prevention for up to 3 units fx-102 : interference prevention for up to 4 units multi-function external input [pro mode] settings such as emission halt, limit / auto teaching and eco settings can be carried out via external input. (brown) + v (blue) 0 v (white) external input (black) output external input lines are equipped as standard alert function [pro mode] when the amount light received approaches the threshold value, the display can be made to blink in order to alert the operator. * when the emission frequencies are changed, the response times will also change. thru-beam type / retroreflective type reflective type object present on object absent off object present on object absent off limit teaching function this carries out teaching and sets threshold values only when no object is present (when the incident light amount is stable). this is useful when sensing objects if there are other objects in the background and when sensing minute objects. teaching can also be carried out using external input. threshold tracking function [pro mode] this function seeks changes in the light emitting amount resulting from changes in the environment over long periods (such as dust levels), so that the incident light intensity can be checked at desired intervals and the threshold values can be reset automatically. time current value the amount of light received when there is no object incident light intensity threshold value geta function [pro mode] the display value for the incident light intensity can be offset by the desired value (target value). the target value can be set to between 0 and 2,000 (in increments of 100). for example, if the incident light intensity is 1,500 and the target value is set to 2,000, then ?2,000? will appear in the digital display. unify at 500 using the geta function variations in the amount of light received the amount of light received ranges from about 900 to 1,100 when the digital indicator flashes. range of the digital indicator flashing (margin: small) 1,100 approx. 900 approx. threshold value of 1,000 the digital indicator flashes. incident light intensity
digital fiber sensor fx-100 series 126 fiber sensors laser sensors photo- electric sensors micro photo- electric sensors area sensors safety components pressure sensors inductive proximity sensors particular use sensors sensor options wire- saving systems measure- ment sensors static control devices laser markers selection guide fiber sensor amplifiers fx-300 fx-100 fibers ft / fd / fr fx-410 fx-311 fx-11a fx-301-f other products fiber sensors fx-100 fiber sensor ampli ers ampli ers type appearance model no. emitting element output standard type fx-101 (note 2) red led npn open-collector transistor m8 plug-in connector type fx-101-z (note 3) npn open-collector transistor fx-101p (note 2) pnp open-collector transistor m8 plug-in connector type fx-101p-z (note 3) pnp open-collector transistor cable set (note 1) fx-101-cc2 npn open-collector transistor fx-101p-cc2 pnp open-collector collector transistor long sensing range type fx-102 (note 2) npn open-collector transistor m8 plug-in connector type fx-102-z (note 3) npn open-collector transistor fx-102p (note 2) pnp open-collector transistor m8 plug-in connector type fx-102p-z (note 3) pnp open-collector transistor cable set (note 1) fx-102-cc2 npn open-collector transistor fx-102p-cc2 pnp open-collector transistor order guide accessory cn-14a-c2 ? connector attached cable 2 m 6.562 ft only include cable set type * notes: 1) the connector attached cable cn-14a-c2 is supplied with the ampli er. 2) make sure to use the optional connector attached cable cn-14a ( -r ) -c or the connector cn-14a , or a connector manufactured by j.s.t. mfg. co., ltd. (contact: sphd-001t-p0.5, housing: pap-04v-s) 3) make sure to use the optional m8 connector attached cable cn-24a-c . designation model no. description connector attached cable cn-14a-c1 1 m 3.281 ft 0.02 mm 2 4-core cabtyre cable with connector on one end cable outer diameter: ?3.7 mm ?0.146 in cn-14a-c2 (note) 2 m 6.562 ft cn-14a-c3 3 m 9.843 ft cn-14a-c5 5 m 16.404 ft connector attached cable (flexible type) cn-14a-r-c1 1 m 3.281 ft cn-14a-r-c2 2 m 6.562 ft cn-14a-r-c3 3 m 9.843 ft cn-14a-r-c5 5 m 16.404 ft m8 connector attached cable cn-24a-c2 2 m 6.562 ft for m8 plug-in connector type the connector on one end cable outer diameter: ?4 mm ?0.157 in cn-24a-c5 5 m 16.404 ft connector cn-14a set of 10 housings and 40 contacts protection cover fc-fx-1 this protects the operating surfaces. ampli er mounting bracket ms-din-4 mounting bracket for ampli er end plates ms-din-e when it moves depending on the way it is installed on a din rail, these end plates ensure that all ampli ers are mounted together in a secure and fully connected manner. two pcs.per set m8 connector attached cable cn-24a-c ? protection cover fc-fx-1 ? options ampli er mounting bracket ms-din-4 ? connector cn-14a ? note: the connector attached cable cn-14a-c2 is supplied with the cable set type fx-10 ( p ) -cc2 . recommended connector recommended crimping tool contact: sphd-001t-p0.5, housing: pap-04v-s (manufactured by j.s.t. mfg. co., ltd.) note: contact the manufacturer for details of the recommended products. model no.: yc-610r (manufactured by j.s.t. mfg. co., ltd.) note: contact the manufacturer for details of the recommended products. contact housing ?9 ?0.354 31.4 1.236 ?4 ?0.157 m8 connector attached cable cn-24a-c fixing ring connector attached cable cn-14a ( -r ) -c ?
127 digital fiber sensor fx-100 series fiber sensors laser sensors photo- electric sensors micro photo- electric sensors area sensors safety components pressure sensors inductive proximity sensors particular use sensors sensor options wire- saving systems measure- ment sensors static control devices laser markers selection guide fiber sensor amplifiers fx-300 fx-100 fibers ft / fd / fr fx-410 fx-311 fx-11a fx-301-f other products fiber sensors fx-100 fiber sensor ampili ers model no. sensing range (mm in ) (note 1) dimensions standard type fx-101 long sensing range type fx-102 ft-a8 1,500 59.055 3,500 137.795 (note 2) p.106 ft-a30 3,500 137.795 (note 2) 3,500 137.795 (note 2) p.106 ft-afm2 280 11.024 720 28.346 p.106 ft-afm2e 240 9.449 670 26.378 p.106 ft-b8 400 15.748 1,150 45.276 p.106 ft-e12 6 0.236 19 0.748 p.106 ft-e22 15 0.591 60 2.362 p.106 ft-fm2 300 11.811 800 31.496 p.106 ft-fm2s p.106 ft-fm2s4 p.106 ft-fm10l 9,300 366.141 15,000 590.550 p.106 ft-h13-fm2 250 9.843 700 27.559 p.106 ft-h20-j20-s (note 3) 135 5.315 420 16.535 p.107 ft-h20-j30-s (note 3) p.107 ft-h20-j50-s (note 3) p.107 ft-h20-m1 210 8.268 540 21.260 p.107 ft-h20-vj50-s (note 3) 150 5.906 500 19.685 p.107 ft-h20-vj80-s (note 3) p.107 ft-h20w-m1 100 3.937 300 11.811 p.107 ft-h30-m1v-s (note 4) 110 4.331 280 11.024 p.107 ft-h35-m2 170 6.693 490 19.291 p.107 ft-h35-m2s6 p.107 ft-hl80y 990 38.976 2,340 92.126 p.107 ft-k8 1,000 39.370 3,000 118.110 p.108 ft-kv1 135 5.315 500 19.685 p.108 ft-kv8 1,000 39.370 3,000 118.110 p.108 ft-l80y 1,100 43.307 2,600 102.362 p.108 ft-nfm2 130 5.118 280 11.024 p.108 ft-nfm2s p.108 FT-NFM2S4 p.108 ft-p2 120 4.724 330 12.992 p.108 ft-p40 80 3.150 240 9.449 p.108 ft-p60 130 5.118 300 11.811 p.108 ft-p80 230 9.055 650 25.591 p.108 ft-p81x 260 10.236 800 31.496 p.108 notes: 1) please take care that the sensing range of the free-cut type ber may be reduced by 20 % max. depending upon how the ber is cut. 2) the ber cable length practically limits the sensing range to 3,500 mm 137.795 in long. 3) heat-resistant joint bers and ordinary-temperature side bers ( ft-fm2 ) are sold as a set. please refer to p.93~ for details. 4) sold as a set comprising vacuum-resistant type ber + photo-terminal ( fv-br1 ) + ber at atmospheric side ( ft-j8 ). please refer to p.91~ for details. thru-beam type (one pair set) fibers are listed in alphabetic order. refer to p.63~ ?fiber selection? for details of each ber. list of fibers model no. sensing range (mm in ) (note 1) dimensions standard type fx-101 long sensing range type fx-102 ft-ps1 40 1.575 90 3.543 p.109 ft-r80 180 7.087 430 16.929 p.109 ft-sfm2 300 11.811 800 31.496 p.109 ft-sfm2l 760 29.921 2,400 94.488 p.109 ft-sfm2sv2 180 7.087 470 18.504 p.109 ft-snfm2 130 5.118 280 11.024 p.109 ft-t80 300 11.811 800 31.496 p.109 ft-v10 1,000 39.370 2,350 92.520 p.109 ft-v22 140 5.512 380 14.961 p.109 ft-v41 40 1.575 120 4.724 p.109 ft-v80y 340 13.386 800 31.496 p.109 ft-w4 80 3.150 220 8.661 p.109 ft-w8 260 10.236 650 25.591 p.110 ft-wa8 1,500 59.055 3,500 137.795 (note 2) p.110 ft-wa30 3,500 137.795 (note 2) 3,500 137.795 (note 2) p.110 ft-wkv8 700 27.559 2,200 86.614 p.110 ft-wr80 215 8.465 570 22.441 p.110 ft-wr80l 430 16.929 1,150 45.276 p.110 ft-ws3 150 5.906 600 23.622 p.110 ft-ws4 80 3.150 220 8.661 p.110 ft-ws8 260 10.236 650 25.591 p.110 ft-ws8l 600 23.622 1,500 59.055 p.110 ft-wv42 30 1.181 80 3.150 p.110 ft-wz4 230 9.055 670 26.378 p.110 ft-wz4hb 80 3.150 230 9.055 p.111 ft-wz7 330 12.992 1,000 39.370 p.111 ft-wz7hb 190 7.480 580 22.835 p.111 ft-wz8 330 12.992 950 37.402 p.111 ft-wz8e 700 27.559 2,100 82.677 p.111 ft-wz8h 1,200 47.244 2,800 110.236 p.111 ft-z8 360 14.173 1,000 39.370 p.111 ft-z8e 800 31.496 1,850 72.835 p.111 ft-z8h 1,400 55.118 3,100 122.047 p.111 ft-z802y 520 20.472 3,100 122.047 p.111
digital fiber sensor fx-100 series 128 fiber sensors laser sensors photo- electric sensors micro photo- electric sensors area sensors safety components pressure sensors inductive proximity sensors particular use sensors sensor options wire- saving systems measure- ment sensors static control devices laser markers selection guide fiber sensor amplifiers fx-300 fx-100 fibers ft / fd / fr fx-410 fx-311 fx-11a fx-301-f other products fiber sensors fx-100 fiber sensor ampli ers list of fibers fibers are listed in alphabetic order. refer to p.63~ ?fiber selection? for details of each ber. retrore ective type model no. sensing range (mm in ) (note 1, 2) dimensions standard type fx-101 long sensing range type fx-102 fr-kv1 15 to 200 0.591 to 7.874 15 to 360 0.591 to 14.173 p.112 fr-kz21 200 7.874 200 7.874 p.112 fr-kz21e 200 7.874 200 7.874 p.112 fr-wkz11 100 to 550 3.937 to 21.654 100 to 830 3.937 to 32.677 p.112 2) the sensing range of fr-wkz11 is the possible setting range for the re ector or re ective tape. the ber can detect an object less than 100 mm 3.937 in away. however, note that if there are any white or highly-re ective surfaces near the ber head, re ected incident light may affect the ber head. if this occurs, adjust the threshold value of the ampli er unit before use. the sensing range of fr-kz21 ( e ) is the possible setting range for the re ector. however, if setting the ber to detect objects passing within 0 to 20 mm 0 to 0.787 in from the ber head, unstable detection may result. the sensing range of fr-kv1 is the possible setting range for the re ector. the ber can detect an object less than 15 mm 0.591 in away. re ective type fibers are listed in alphabetic order. refer to ?fiber selection p.63~? for details of each ber. model no. sensing range (mm in ) (note 1, 2) dimensions standard type fx-101 long sensing range type fx-102 fd-a15 125 4.921 250 9.843 p.113 fd-afm2 105 4.134 285 11.220 p.113 fd-afm2e 85 3.346 245 9.646 p.113 fd-b8 170 6.693 440 17.323 p.113 fd-e12 3.5 0.138 13 0.512 p.113 fd-e22 16 0.630 45 1.772 p.113 fd-eg1 18 0.709 50 1.969 p.113 fd-eg2 10 0.394 30 1.181 p.113 fd-eg3 7 0.276 22 0.866 p.113 fd-en500s1 1 0.039 4 0.157 p.113 fd-enm1s1 15 0.591 48 1.890 p.114 fd-f4 applicable pipe diameter: outer dia. ?6 to ?26 mm ?0.236 to ?1.024 in transparent pipe [pfa ( uorine resin) or equivalently transparent pipe, wall thickness 1 mm 0.039 in ] p.114 fd-f41 applicable pipe diameter: outer dia. ?6 to ?26 mm ?0.236 to ?1.024 in transparent pipe [pvc (vinyl chloride), uorine resin, polycarbonate, acrylic, glass, wall thickness 1 to 3 mm 0.039 to 0.118 in ] p.114 fd-f8y ? p.114 fd-fm2 100 3.937 410 16.142 p.114 fd-fm2s 100 3.937 345 13.583 p.114 fd-fm2s4 p.114 fd-g4 50 1.969 120 4.724 p.114 model no. sensing range (mm in ) (note 1, 2) dimensions standard type fx-101 long sensing range type fx-102 fd-g6 50 1.969 120 4.724 p.114 fd-g6x 45 1.772 160 6.299 p.114 fd-h13-fm2 100 3.937 280 11.024 p.114 fd-h18-l31 0 to 10 0 to 0.394 0 to 25 0 to 0.984 p.115 fd-h20-21 90 3.543 280 11.024 p.115 fd-h20-m1 120 4.724 300 11.811 p.115 fd-h30-kz1v-s (note 3) 25 to 80 0.984 to 3.150 10 to 220 0.394 to 8.661 p.115 fd-h30-l32 2 to 9 0.079 to 0.354 0 to 17 0 to 0.669 p.115 fd-h30-l32v-s (note 3) 2.5 to 6.5 0.098 to 0.256 0 to 11 0 to 0.433 p.115 fd-h35-20s 85 3.346 200 7.874 p.116 fd-h35-m2 75 2.953 280 11.024 p.116 fd-h35-m2s6 p.116 fd-l4 5 to 8 0.197 to 0.315 (convergent point 6 0.236 ) 1 to 17 0.039 to 0.669 (convergent point 6 0.236 ) p.116 fd-l41 3 to 14 0.118 to 0.551 (convergent point 8 0.315 ) 1.5 to 16 0.059 to 0.630 (convergent point 8 0.315 ) p.116 fd-l43 0 to 19 0 to 0.748 0 to 25 0 to 0.984 p.116 fd-l44 0 to 6 0 to 0.236 0 to 8 0 to 0.315 p.116 fd-l44s 0 to 4.5 0 to 0.177 0 to 5.5 0 to 0.217 p.116 fd-l45 0 to 40 0 to 1.575 0 to 50 0 to 1.969 p.116 fd-l46 16 to 30 0.630 to 1.181 12 to 50 0.472 to 1.969 p.116 fd-nfm2 35 1.378 100 3.937 p.117 fd-nfm2s p.117 fd-nfm2s4 p.117 fd-p2 25 0.984 65 2.559 p.117 notes: 1) the standard sensing objects of the sensing ranges vary depending on the bers. refer to p.71~ for details. 2) please take care that the sensing range of the free-cut type ber may be reduced by 20 % max. depending upon how the ber is cut. 3) sold as a set comprising vacuum-resistant type ber + photo-terminal ( fv-br1 ) + ber at atmospheric side ( ft-j8 ). please refer to p.91~ for details. notes: 1) please take care that the sensing range of the free-cut type ber may be reduced by 20 % max. depending upon how the ber is cut. the sensing range of fr-wkz11 is speci ed for the rf-13 . the sensing range of fr-kz21 , fr-kz21e and fr-kv1 is speci ed for the attached re ector. the sensing ranges when using in combination with the fr-wkz11 re ector (optional) are given in the below table. ampli er re ector fx-101 fx-102 fr-wkz11 + rf-210 100 to 700 3.937 to 27.559 100 to 1,100 3.937 to 43.307 fr-wkz11 + rf-220 100 to 1,300 3.937 to 51.181 100 to 2,600 3.937 to 102.362 fr-wkz11 + rf-230 100 to 2,000 3.937 to 78.740 100 to 4,000 3.937 to 157.480
129 digital fiber sensor fx-100 series fiber sensors laser sensors photo- electric sensors micro photo- electric sensors area sensors safety components pressure sensors inductive proximity sensors particular use sensors sensor options wire- saving systems measure- ment sensors static control devices laser markers selection guide fiber sensor amplifiers fx-300 fx-100 fibers ft / fd / fr fx-410 fx-311 fx-11a fx-301-f other products fiber sensors fx-100 fiber sensor ampili ers list of fibers model no. sensing range (mm in ) (note 1, 2) dimensions standard type fx-101 long sensing range type fx-102 fd-p40 8 0.315 30 1.181 p.117 fd-p50 45 1.772 150 5.906 p.117 fd-p60 45 1.772 150 5.906 p.117 fd-p80 90 3.543 200 7.874 p.117 fd-p81x 70 2.756 220 8.661 p.117 fd-r80 70 2.756 180 7.087 p.117 fd-s80 100 3.937 345 13.583 p.117 fd-sfm2sv2 30 1.181 90 3.543 p.117 fd-snfm2 35 1.378 100 3.937 p.118 fd-t40 35 1.378 100 3.937 p.118 fd-t80 100 3.937 345 13.583 p.118 fd-v41 25 0.984 70 2.756 p.118 fd-w8 80 3.150 230 9.055 p.118 fd-w44 15 0.591 40 1.575 p.118 re ective type fibers are listed in alphabetic order. refer to ?fiber selection p.63~? for details of each ber. model no. sensing range (mm in ) (note 1, 2) dimensions standard type fx-101 long sensing range type fx-102 fd-wg4 28 1.102 75 2.953 p.118 fd-wkz1 20 to 180 0.787 to 7.087 20 to 480 0.787 to 18.898 p.118 fd-wl41 7 to 12 0.276 to 0.472 (convergent point 8 0.315 ) 6 to 13.5 0.236 to 0.531 (convergent point 8 0.315 ) p.118 fd-wl48 1 to 4.5 0.039 to 0.177 0.5 to 6.5 0.020 to 0.256 p.119 fd-ws8 80 3.150 230 9.055 p.119 fd-wsg4 28 1.102 75 2.953 p.119 fd-wt4 15 0.591 40 1.575 p.119 fd-wt8 80 3.150 230 9.055 p.119 fd-wv42 6 0.236 20 0.787 p.119 fd-wz4 2 to 20 0.079 to 0.787 1 to 70 0.039 to 2.756 p.119 fd-wz4hb p.119 fd-wz7 1 to 55 0.039 to 2.165 160 6.299 p.119 fd-wz7hb 1 to 60 0.039 to 2.362 0.5 to 180 0.020 to 7.087 p.119 notes: 1) the standard sensing objects of the sensing ranges vary depending on the bers. refer to p.71~ for details. 2) please take care that the sensing range of the free-cut type ber may be reduced by 20 % max. depending upon how the ber is cut. 3) sold as a set comprising vacuum-resistant type ber + photo-terminal ( fv-br1 ) + ber at atmospheric side ( ft-j8 ). please refer to p.91~ for details.
digital fiber sensor fx-100 series 130 fiber sensors laser sensors photo- electric sensors micro photo- electric sensors area sensors safety components pressure sensors inductive proximity sensors particular use sensors sensor options wire- saving systems measure- ment sensors static control devices laser markers selection guide fiber sensor amplifiers fx-300 fx-100 fibers ft / fd / fr fx-410 fx-311 fx-11a fx-301-f other products fiber sensors fx-100 fiber sensor ampli ers lens (for thru-beam type ber) designation model no. description for thru-beam type ber expansion lens (note 1) fx-le1 increases the sensing range by 5 times or more. ? ambient temperature: ? 60 to +350 c ? 76 to +662 f (note 3) sensing range (mm in ) [lens on both sides] ampli er fiber fx-101 fx-102 ft-b8 2,200 86.614 3,500 137.795 (note 2) ft-fm2 , ft-t80 3,000 118.110 3,500 137.795 (note 2) ft-r80 1,900 74.803 3,500 137.795 (note 2) ft-w8 3,000 118.110 3,500 137.795 (note 2) ft-p80 , ft-p60 3,500 137.795 (note 2) 3,500 137.795 (note 2) ft-p81x 1,600 62.992 (note 2) 1,600 62.992 (note 2) ft-h35-m2 2,000 78.740 3,500 137.795 (note 2) ft-h20w-m1 1,300 51.181 1,600 62.992 (note 2) ft-h20-m1 1,600 62.992 (note 2) 1,600 62.992 (note 2) ft-h20-j20-s , ft-h20-j30-s , ft-h20-j50-s 1,000 39.370 3,500 137.795 (note 2) super- expansion lens (note 1) fx-le2 tremendously increases the sensing range with large diameter lenses. ? ambient temperature: ? 60 to +350 c ? 76 to +662 f (note 3) sensing range (mm in ) [lens on both sides] ampli er fiber fx-101 fx-102 ft-b8 , ft-fm2 , ft-r80 , ft-w8 , ft-p80 , ft-p60 3,500 137.795 (note 2) 3,500 137.795 (note 2) ft-p81x 1,600 62.992 (note 2) 1,600 62.992 (note 2) ft-h35-m2 3,500 137.795 (note 2) 3,500 137.795 (note 2) ft-h20w-m1 , ft-h20-m1 1,600 62.992 (note 2) 1,600 62.992 (note 2) ft-h13-fm2 3,500 137.795 (note 2) 3,500 137.795 (note 2) ft-h20-j20-s , ft-h20-j30-s , ft-h20-j50-s 3,500 137.795 (note 2) 3,500 137.795 (note 2) side-view lens fx-sv1 beam axis is bent by 90. ? ambient temperature: ? 60 to +300 c ? 76 to +572 f (note 3) sensing range (mm in ) [lens on both sides] ampli er fiber fx-101 fx-102 ft-b8 530 20.866 1,450 57.087 ft-fm2 , ft-t80 550 21.654 1,700 66.929 ft-w8 450 17.717 1,300 51.181 ft-p80 420 16.535 1,400 55.118 ft-p60 300 11.811 850 33.465 ft-p81x 550 21.654 1,700 66.929 ft-h35-m2 280 11.024 800 31.496 ft-h20w-m1 140 5.512 400 15.748 ft-h20-m1 280 11.024 840 33.071 ft-h20-j20-s , ft-h20-j30-s , ft-h20-j50-s 150 5.906 410 16.142 expansion lens for vacuum- resistant ber (note 1) fv-le1 sensing range increases by 4 times or more. ? ambient temperature: ? 60 to +350 c ?76 to +662 f (note 3) sensing range (mm in ) [lens on both sides] (note 4) ampli er fiber fx-101 fx-102 ft-h30-m1v 450 17.717 1,600 62.992 side-view lens for vacuum- resistant ber fv-sv2 beam axis is bent by 90. ? ambient temperature: ? 60 to +300 c ?76 to +572 f (note 3) sensing range (mm in ) [lens on both sides] (note 4) ampli er fiber fx-101 fx-102 ft-h30-m1v 450 17.717 1,600 62.992 notes: 1) be careful when installing the thru-beam type ber equipped with the expansion lens, as the beam envelope becomes narrow and alignment is dif cult. especially when installing a ber with many cores (sharp bending bers and heat-resistant glass ber), please be sure to use it only after you have adjusted it suf ciently. 2) the ber cable length practically limits the sensing range to 3,500 mm 137.795 in long ( ft-h20w-m1 , ft-p81x and ft-h20-m1 : 1,600 mm 62.992 in ). 3) for details on the ambient temperatures for the bers which being combined, refer to p.101~. 4) the ber cable length for the ft-h30-m1v is 1 m 3.281 ft . the sensing ranges in fx-102 (long sensing range type) take into account the length of the ft-j8 atmospheric side ber. fiber options the dimensions are on p.120~.
131 digital fiber sensor fx-100 series fiber sensors laser sensors photo- electric sensors micro photo- electric sensors area sensors safety components pressure sensors inductive proximity sensors particular use sensors sensor options wire- saving systems measure- ment sensors static control devices laser markers selection guide fiber sensor amplifiers fx-300 fx-100 fibers ft / fd / fr fx-410 fx-311 fx-11a fx-301-f other products fiber sensors fx-100 fiber sensor ampili ers lens (for re ective type ber) designation model no. description for re ective type ber pinpoint spot lens fx-mr1 pinpoint spot of ?0.5 mm ?0.020 in . enables detection of minute objects or small marks. ? distance to focal point: 6 1 mm 0.236 0.039 in ? applicable bers: fd-wg4 , fd-g4 ? ambient temperature: ?40 to +70 c ?40 to +158 f (note 2) zoom lens fx-mr2 screw-in depth distance to focal point spot diameter the spot diameter is adjustable from ?0.7 to ?2 mm ?0.028 to ?0.079 in according to how much the ber is screwed in. ? applicable bers: fd-wg4 , fd-g4 ? ambient temperature: ?40 to +70 c ?40 to +158 f (note 2) ? accessory: ms-ex-3 (mounting bracket) sensing range for fx-101 (mm in ) (note 1) screw-in depth distance to focal point spot diameter 7 mm 0.276 in 18.5 0.728 approx. ?0.7 ?0.028 12 mm 0.472 in 27 1.063 approx. ?1.2 ?0.047 14 mm 0.551 in 43 1.693 approx. ?2.0 ?0.079 finest spot lens fx-mr3 distance to focal point spot diameter extremely ne spot of ?0.3 mm ?0.012 in approx. achieved. ? applicable bers: fd-wg4 , fd-g4 , fd-eg1 , fd-eg2 , fd-eg3 , fd-g6x , fd-g6 ? ambient temperature: ?40 to +70 c ?40 to +158 f (note 2) sensing range for fx-101 (mm in ) (note 1) fiber model no. distance to focal point spot diameter fd-eg3 7.5 0.5 0.295 0.020 ?0.15 ?0.006 approx. fd-eg2 7.5 0.5 0.295 0.020 ?0.2 ?0.008 approx. fd-eg1 7.5 0.5 0.295 0.020 ?0.3 ?0.012 approx. fd-wg4/g4 , fd-g6x/g6 7.5 0.5 0.295 0.020 ?0.5 ?0.020 approx. finest spot lens fx-mr6 extremely ne spot of ?0.1 mm ?0.004 in approx. achieved. ? applicable bers: fd-wg4 , fd-g4 , fd-eg1 , fd-eg2 , fd-eg3 , fd-g6x , fd-g6 ? ambient temperature: ?20 to +60 c ?4 to +140 f (note 2) sensing range for fx-101 (mm in ) (note 1) fiber model no. distance to focal point spot diameter fd-eg3 7 0.5 0.276 0.020 ?0.1 ?0.004 approx. fd-eg2 7 0.5 0.276 0.020 ?0.15 ?0.006 approx. fd-eg1 7 0.5 0.276 0.020 ?0.2 ?0.008 approx. fd-wg4/g4 , fd-g6x/g6 7 0.5 0.276 0.020 ?0.4 ?0.016 approx. zoom lens side-view type fx-mr5 fx-mr2 is converted into a side-view type and can be mounted in a very small space. ? applicable bers: fd-wg4 , fd-g4 ? ambient temperature: ?40 to +70 c ?40 to +158 f (note 2) sensing range for fx-101 (mm in ) (note 1) screw-in depth distance to focal point spot diameter 8 mm 0.315 in 13 0.512 approx. ?0.5 ?0.020 10 mm 0.394 in 15 0.591 approx. ?0.8 ?0.031 14 mm 0.551 in 30 1.181 approx. ?3.0 ?0.118 screw-in depth spot diameter distance to focal point screw-in depth spot diameter distance to focal point notes: 1) the sensing ranges are the values when used in combination with fx-101 (standard type). please contact our of ce for details on sensing ranges for other types of ampli er. 2) for details on the ambient temperatures for the bers which being combined, refer to p.101~. fiber options the dimensions are on p.121~.
digital fiber sensor fx-100 series 132 fiber sensors laser sensors photo- electric sensors micro photo- electric sensors area sensors safety components pressure sensors inductive proximity sensors particular use sensors sensor options wire- saving systems measure- ment sensors static control devices laser markers selection guide fiber sensor amplifiers fx-300 fx-100 fibers ft / fd / fr fx-410 fx-311 fx-11a fx-301-f other products fiber sensors fx-100 fiber sensor ampli ers specifications notes: 1) where measurement conditions have not been speci ed precisely, the conditions used were an ambient temperature of +23 c +73.4 f . 2) when using the interference prevention function, set the emission frequencies for the ampli ers to be covered by the interference prevention function to different frequency values. however, the interference prevention function does not operate at emission frequency 0 (factory default setting) for the fx-101 ( p )( -z ) / fx-101 ( p ) -cc2 . 3) the voltage withstandability and the insulation resistance values given in the above table are for the ampli er only. 4) connector attached cable cn-14a-c2 is not attached to the models that have no ? -cc2 ? at the end of the model nos. make sure to use the optional connector attached cable cn-14a ( -r ) -c or the connector cn-14a , or a connector manufactured by j.s.t. mfg., ltd. (contact: sphd-001t-p0.5, housing: pap-04v-s). model nos. having the suf x ? -z ? are m8 plug-in connector type. make sure to use the optional m8 attached connector cable cn-24a-c . type standard type long sensing range type cable set cable set model no. npn output fx-101 ( -z ) (note 4) fx-101-cc2 fx-102 ( -z ) (note 4) fx-102-cc2 item pnp output fx-101p ( -z ) (note 4) fx-101p-cc2 fx-102p ( -z ) (note 4) fx-102p-cc2 supply voltage 12 to 24 v dc 10 % ripple p-p 10 % or less power consumption normal operation: 720 mw or less (current consumption 30 ma or less at 24 v supply voltage) eco mode: 600 mw or less (current consumption 25 ma or less at 24 v supply voltage) output npn open-collector transistor ? maximum sink current: 100 ma ? applied voltage: 30 v dc or less (between output and 0 v) ? residual voltage: 1.5 v or less (at 100 ma sink current) pnp open-collector transistor ? maximum source current: 100 ma ? applied voltage: 30 v dc or less (between output and +v) ? residual voltage: 1.5 v or less (at 100 ma source current) output operation selectable either light-on or dark-on, at set mode short-circuit protection incorporated external input npn non-contact input ? signal condition high: +8 v to +v dc or open low: 0 to +2 v dc (source current 0.5 ma or less) ? input impedance: 10 k approx. pnp non-contact input ? signal condition high: +4 v to +v dc (sink current 0.5 to 3 ma) low: 0 to +0.6 v dc or open ? input impedance: 10 k approx. response time emission frequency 0: 250 s or less (factory default setting) emission frequency 1: 450 s or less emission frequency 2: 500 s or less emission frequency 3: 600 s or less emission frequency 1: 2.5 ms or less (factory default setting) emission frequency 2: 2.8 ms or less emission frequency 3: 3.2 ms or less emission frequency 4: 5.0 ms or less sensitivity setting 2-level teaching / limit teaching / full-auto teaching operation indicator orange led (lights up when the output is on) digital display 4 digits (green) + 4 digits (red) lcd display fine sensitivity adjustment function incorporated timer function on-delay / off-delay timer, switchable either effective or ineffective [timer period: 1 ms, 5 ms, 10 ms, 20 ms, 40 ms, 50 ms, 100 ms, 500 ms, 1,000 ms] attenuation function incorporated switchable either effective or ineffective interference prevention function incorporated emission frequency selection method (note 2) (functions at emission frequency 1, 2 or 3) incorporated emission frequency selection method (note 2) (functions at emission frequency 1, 2, 3 or 4) environmental resistance ambient temperature ?10 to +55 c +14 to +131 f (if 4 to 7 units are mounted close together: ?10 to +50 c +14 to +122 f , if 8 to 16 units are mounted close together: ?10 to +45 c +14 to +113 f ) (no dew condensation or icing allowed), storage: ?20 to +70 c ?4 to +158 f ambient humidity 35 to 85 % rh, storage: 35 to 85 % rh ambient illuminance incandescent light: 3,000 ? x at the light-receiving face voltage withstandability 1,000 v ac for one min. between all supply terminals connected together and enclosure (note 3) insulation resistance 20 m , or more, with 250 v dc megger between all supply terminals connected together and enclosure (note 3) vibration resistance 10 to 150 hz frequency, 0.75 mm 0.030 in amplitude in x, y and z directions for two hours each shock resistance 98 m/s 2 acceleration (10 g approx.) in x, y and z directions for ve times each emitting element (modulated) red led (peak emission wavelength: 632 nm 0.025 mil ) material enclosure: polycarbonate, key switch: polycarbonate, fiber lock lever: pbt connecting method connector (note 4) cable length total length up to 100 m 328.084 ft is possible with 0.3 mm 2 , or more, cable. weight net weight: 15 g approx. gross weight: 35 g approx. net weight: 15 g approx. gross weight: 75 g approx. net weight: 15 g approx. gross weight: 35 g approx. net weight: 15 g approx. gross weight: 75 g approx. accessory ? cn-14a-c2 (connector attached cable, 2 m 6.562 ft long): 1pc. ? cn-14a-c2 (connector attached cable, 2 m 6.562 ft long): 1pc. refer to p.101~ for ber speci cations.
133 digital fiber sensor fx-100 series fiber sensors laser sensors photo- electric sensors micro photo- electric sensors area sensors safety components pressure sensors inductive proximity sensors particular use sensors sensor options wire- saving systems measure- ment sensors static control devices laser markers selection guide fiber sensor amplifiers fx-300 fx-100 fibers ft / fd / fr fx-410 fx-311 fx-11a fx-301-f other products fiber sensors fx-100 fiber sensor ampili ers i/o circuit and wiring diagrams fx-10 ( -z/-cc2 ) npn output type users circuit internal circuit + C 12 to 24 v dc 10 % 100 ma max. * 1 d tr load (brown) +v (blue) 0 v (white) extemal input (black) output terminal no. color code of cable with connector z d + 8 v sensor circuit 1 2 3 4 i/o circuit diagram 1 2 3 4 terminal arrangement diagram connector type terminal no. function 1 +v 2 output 3 external input 4 0 v m8 plug-in connector type terminal no. function 1 +v 2 output 3 external input 4 0 v 1 2 3 4 symbols ? d : reverse supply polarity protection diode z d : surge absorption zener diode tr : npn output transistor non-voltage contact or npn open-collector transistor or high (+8 v to +v dc, or open): ineffective low [(0 to +2 v dc (source current 0.5 ma or less)]: effective 1 * fx-10 p ( -z/-cc2 ) pnp output type i/o circuit diagram users circuit internal circuit 12 to 24 v dc 10 % 100 ma max. * 1 t i u c r i c r o s n e s d tr z d load + C (brown) +v (blue) 0 v (white) external input (black) output terminal no. color code of cable with connector 2 3 4 1 2 3 4 terminal arrangement diagram connector type terminal no. function 1 +v 2 output 3 external input 4 0 v m8 plug-in connector type terminal no. function 1 +v 2 output 3 external input 4 0 v 1 2 3 4 non-voltage contact or pnp open-collector transistor or high [ +4 v to +v dc (sink current 0.5 to 3 ma)]: effective low (0 to +0.6 v dc, or open): ineffective 1 * symbols ? d : reverse supply polarity protection diode z d : surge absorption zener diode tr : pnp output transistor
digital fiber sensor fx-100 series 134 fiber sensors laser sensors photo- electric sensors micro photo- electric sensors area sensors safety components pressure sensors inductive proximity sensors particular use sensors sensor options wire- saving systems measure- ment sensors static control devices laser markers selection guide fiber sensor amplifiers fx-300 fx-100 fibers ft / fd / fr fx-410 fx-311 fx-11a fx-301-f other products fiber sensors fx-100 fiber sensor ampli ers sensing characteristics (typical) 1,000 39.37 2,000 78.74 3,000 118.11 4,000 157.48 0 200 7.874 100 3.937 0 100 3.937 200 7.874 fx-102 fx-101 setting distance l (mm in ) operating point ? (mm in ) center down up ? 8 mm 0.315 in approx. fiber head fiber head l 0 operating point ? (mm in ) center left right 200 7.874 100 3.937 0 100 3.937 200 7.874 1,000 39.37 2,000 78.74 3,000 118.11 4,000 157.48 fx-102 fx-101 ? fiber head fiber head l setting distance l (mm in ) 1,000 39.370 500 19.685 0 1,000 39.37 500 19.685 0 500 19.685 1,000 39.37 fx-102 operating point ? (mm in ) center left right ? fiber head fiber head l setting distance l (mm in ) fx-101 400 15.748 200 7.874 0 200 7.874 400 15.748 operating point ? (mm in ) center left right 1,000 39.370 500 19.685 0 fx-101 fx-102 ? fiber head fiber head l setting distance l (mm in ) thru-beam type ft-a8 thru-beam type ft-b8 thru-beam type ft-fm2 ft-fm2s ft-fm2s4 ft-sfm2 ft-t80 parallel deviation vertical direction ? horizontal direction ? parallel deviation parallel deviation 100 3.937 50 1.969 050 1.969 100 3.937 0 operating point ? (mm in ) center left right 400 15.748 200 7.874 fx-102 fx-101 l ? white non-glossy paper fiber head setting distance l (mm in ) 100 3.937 50 1.969 050 1.969 100 3.937 200 7.874 400 15.748 0 operating point ? (mm in ) center left right fx-102 fx-101 l ? white non-glossy paper fiber head setting distance l (mm in ) 40 1.575 20 0.787 020 0.787 40 1.575 50 1.969 100 3.937 0 operating point ? (mm in ) center left right fx-102 fx-101 l ? white non-glossy paper fiber head setting distance l (mm in ) 40 1.575 20 0.787 020 0.787 40 1.575 0 operating point ? (mm in ) center left right 50 1.969 100 3.937 150 5.906 200 7.874 fx-102 fx-101 l ? white non-glossy paper fiber head setting distance l (mm in ) re ective type fd-g4 re ective type fd-g6x re ective type fd-b8 re ective type fd-fm2 sensing eld sensing eld sensing eld sensing eld 200 7.874 100 3.937 100 3.937 200 7.874 100 3.937 200 7.874 300 11.811 400 15.748 0 fx-102 fx-101 operating point ? (mm in ) center left right ? fiber head fiber head - setting distance l (mm in ) 400 15.748 200 7.874 0 200 7.874 400 15.748 operating point ? (mm in ) center left right 1,000 39.370 500 19.685 0 fx-102 fx-101 ? fiber head fiber head l setting distance l (mm in ) 100 3.937 50 1.969 050 1.969 100 3.937 operating point ? (mm in ) center left right 200 7.874 100 3.937 0 fx-102 fx-101 ? fiber head fiber head l setting distance l (mm in ) 200 7.874 100 3.937 0 100 3.937 200 7.874 200 7.874 400 15.748 600 23.622 800 9.843 0 fx-102 fx-101 operating point ? (mm in ) center left right ? fiber head fiber head l setting distance l (mm in ) thru-beam type ft-w4 ft-ws4 thru-beam type ft-w8 ft-ws8 thru-beam type ft-nfm2 ft-nfm2s FT-NFM2S4 ft-snfm2 thru-beam type ft-p81x parallel deviation parallel deviation parallel deviation parallel deviation operating point ? (mm in ) center left right 100 3.937 50 1.969 0 20 0.787 10 0.394 010 0.394 20 0.787 fx-101 fx-102 l ? white non-glossy paper fiber head setting distance l (mm in ) operating point ? (mm in ) center left right 200 7.874 100 3.937 0 40 1.575 20 0.787 020 0.787 40 1.575 fx-101 fx-102 l ? white non-glossy paper fiber head setting distance l (mm in ) 40 1.575 20 0.787 020 0.787 40 1.575 operating point ? (mm in ) center left right 200 7.874 100 3.937 0 fx-101 fx-102 l ? white non-glossy paper fiber head setting distance l (mm in ) operating point ? (mm in ) center left right 20 0.787 10 0.394 010 0.394 20 0.787 0 fx-102 fx-101 20 0.787 40 1.575 60 2.362 80 3.150 l ? white non-glossy paper fiber head setting distance l (mm in ) sensing eld sensing eld sensing eld sensing eld re ective type fd-w8 fd-ws8 fd-wt8 re ective type fd-wg4 fd-wsg4 re ective type fd-nfm2 fd-nfm2s fd-nfm2s4 fd-snfm2 fd-t40 re ective type fd-p81x contact our of ce for sensing characteristics that are not contained here.
135 digital fiber sensor fx-100 series fiber sensors laser sensors photo- electric sensors micro photo- electric sensors area sensors safety components pressure sensors inductive proximity sensors particular use sensors sensor options wire- saving systems measure- ment sensors static control devices laser markers selection guide fiber sensor amplifiers fx-300 fx-100 fibers ft / fd / fr fx-410 fx-311 fx-11a fx-301-f other products fiber sensors fx-100 fiber sensor ampili ers precautions for proper use refer to p.986~ for general precautions, and to the ?operation guide? or ?sunx website? (http://www.sunx.com) for details pertaining to operating instructions for the ampli er. never use this product as a sensing device for personnel protection. in case of using sensing devices for personnel protection, use products which meet laws and standards, such as osha, ansi or iec etc., for personnel protection applicable in each region or country. ? ? the fx-100 series does not use the horizontal connectors that are used with the fx-300 / fx-400 series. please note that horizontal connection cannot be performed using a connector attached cable. in addition, the optical communication function is not equipped on the fx-100 series, so it is unable to perform interference prevention for use with the fx-300 / fx-400 series. if using the fx-100 series together with the fx-300 / fx-400 series side-by-side, please set the same models together in groups. ? using in combination with the fx-300 / fx-400 series mounting how to mount the ampli er 1 fit the rear part of the mounting section of the ampli er on a 35 mm 1.378 in width din rail. 2 press down the rear part of the mounting section of the unit on the 35 mm 1.378 in width din rail and t the front part of the mounting section to the din rail. part description setting mode setting mode appears after the mode key is pressed for 2 sec. in run mode. ? setting item factory setting description teaching mode threshold value can be set in 2-level teaching, limit teaching, or full-auto teaching. output operation setting [dark-on] light-on or dark-on can be set. timer operation setting [without timer] without timer, on delay timer, or off delay timer can be set. timer setting [on-delay timer: 10 ms] [off-delay timer: 10 ms] in case of setting on-delay timer or off-delay timer in the timer operation setting mode, timer can be set. when timer is not set, this mode is not displayed. emission amount setting [off] setting for reduced intensity of emission amount is possible when the incident light intensity is saturated. emission frequency setting fx-101 0 (response time: 250 s or less) fx-102 1 (response time: 2.5 ms or less) in case of using the ber heads in parallel, interference can be prevented by setting different emission frequency. however, when emission frequency 0 is set, interference cannot be prevented. response time corresponds to emission frequency. for details, refer to ? specifications ? on p.132. operation indicator (orange) mode key on key / setting value up key off key / setting value down key digital display (green) (threshold value) digital display (red) (incident light intensity) 35 mm 1.378 in width din rail 1 2 how to remove the ampli er 1 push the ampli er forward. 2 lift up the front part of the ampli er to remove it. note: take care that if the front part is lifted without pushing the ampli er forward, the hook on the rear portion of the mounting section is likely to break. use m3 screws with washers for mounting. the tightening torque should be 0.5 nm or less. ? 1 2 m3 screw with washer
digital fiber sensor fx-100 series 136 fiber sensors laser sensors photo- electric sensors micro photo- electric sensors area sensors safety components pressure sensors inductive proximity sensors particular use sensors sensor options wire- saving systems measure- ment sensors static control devices laser markers selection guide fiber sensor amplifiers fx-300 fx-100 fibers ft / fd / fr fx-410 fx-311 fx-11a fx-301-f other products fiber sensors fx-100 fiber sensor ampli ers pro mode pro mode appears after the mode key is pressed for 4 sec. in run mode. ? setting item factory setting description shift setting [shift amount 15 %] shift amount can be selected from 0 to 80 % in the limit teaching. select 0 % when it is desired to set the present incident light intensity as a threshold value. external input setting [emission halt] extemal input can be selected from emission halt, limit +, limit -, auto, and eco. threshold value follow-up cycle setting (note 1) [off] when incident light intensity exceeds threshold value, this mode can change the threshold value with each set cycle depending on variations of the incident light intensity. the follow-up shift amount is same as the one set in the shift setting mode. however, the threshold value is not stored. geta function setting (note 2, 3) [off] variations can be reduced by correcting the present incident light intensity in each ampli er to a target value. target value to offset incident light intensity can be selected from 0 to 2,000 by 100 unit each. for example, if the target value is set to 2,000 when the incident light intensity is 1,500, the incident light intensity becomes 2,000. eco setting [off] it is possible to light up / turn off the digital display. when eco setting mode is on, the display turns off in 20 sec. approx. in run mode. to light up the display again, press any key for 2 sec. or more. digital display inversion setting [off] digital display can be inverted. threshold value margin setting [off] margin for threshold value to the present incident light intensity can be checked. when there is no margin, it is possible to make the digital display blink. : set to ?off?: does not function. : green blinks. : red blinks. : red and green blink. setting copy [no] the settings of the master side ampli er can be copied to the slave side ampli er. for details, refer to ? setting copy function . ? reset [no] returns to default settings (factory settings.) notes: 1) if the incident light intensity becomes ?300? or less, the follow-up operation stops. in that condition, threshold value [digital display (green)] blinks. this function can be used when thru-beam type or retrore ective type ber is applied to this product. if re ective type ber is applied, the function cannot be used depending on use conditions. 2) if mode key is pressed in run mode when geta function is used, the incident light intensity before setting geta function is displayed on the red digital display for 2 sec. approx. 3) when geta function is used in saturation of incident light intensity (4,000 or more,) ? ? is indicated on the red digital display. correction value is up to 4,000. setting copy function this can copy the settings of the master side ampli er to the slave side ampli er. ? be sure to use the setting copy function between the identical models (between fx-10 models or fx-102 models). this function cannot be used between different models. only one sensor can be connected on slave side with a master side sensor for the setting copy function. threshold value, output operation setting, timer operation setting, timer setting, light-emitting amount setting, shift setting, eco setting, digital display inversion setting, and threshold value margin setting can be copied. ? ? ? 1 set the setting copy mode of the master side ampli er to ?copy sending on?, and press the mode key so that ? ? is shown on the digital display and the sensor is in copy ready state. for the setting method, refer to ? operation guide ?. 2 turn off the master side ampli er. 3 connect the master side ampli er with the slave side ampli er as shown below. 4 turn on the master side ampli er and the slave side ampli er at the same time. (note) 5 ? ? is shown on the green digital display of the master side ampli er and 4-digit code is shown on the red digital display of it, then the copying starts. during copy communication, ? ? is shown on the green digital display of the slave side ampli er, and the ongoing copy communication indicator (? ?? ?? ? ? ?) is displayed on the red digital display. 6 when the copying is completed, ? ? is shown on the green digital display of the slave side ampli er, while the 4-digit code (the same code as the master side ampli er) is shown on the red digital display of it. 7 turn off the power of the master side ampli er and the slave side ampli er and disconnect the wire. if copying the settings to another ampli er repeatedly, follow the steps 3 to 7 . note: take care that if the power is not turned on at the same time, the setting contents may not be copied. 1 while the slave side ampli er is disconnected, turn on the power of the master side ampli er. 2 press the mode key for 2 sec. approx. * master side amplifier slave side amplifier color code of cable with connector + C 12 to 24v dc 10 % (brown) +v (black) input (white) extemal input (blue) 0 v (brown) +v (black) input (white) extemal input (blue) 0 v precautions for proper use refer to p.986~ for general precautions, and to the ?operation guide? or ?sunx website? (http://www.sunx.com) for details pertaining to operating instructions for the ampli er.
137 digital fiber sensor fx-100 series fiber sensors laser sensors photo- electric sensors micro photo- electric sensors area sensors safety components pressure sensors inductive proximity sensors particular use sensors sensor options wire- saving systems measure- ment sensors static control devices laser markers selection guide fiber sensor amplifiers fx-300 fx-100 fibers ft / fd / fr fx-410 fx-311 fx-11a fx-301-f other products fiber sensors fx-100 fiber sensor ampili ers code setting function settings for ?output operation?, ?timer?, ?emission amount?, ?emission frequency?, ?eco?, ?external input?, and ?shift amount? are possible by selecting codes discretionary. the code setting function makes it possible to set the output operation, timer operation, amount of light emitted, frequency of light emitted, eco setting, external input, and amount of shift by selecting a code of one?s choice. while in the run mode, pressing and holding both the on key ( ) and off key ( ) simultaneously for 4 seconds will switch to the code setting function. ? ? ? quick setting function settings for ?output operation?, ?light-emitting amount?, ?timer?, and ?emission frequency? are possible simply by selecting a setting number. the quick setting function makes it possible to set the content of the set mode (output operation, timer operation, amount of light emitted, and frequency of light emitted) simply by selecting a setting number. while in the run mode, pressing and holding both the on key ( ) and off key ( ) simultaneously for 2 seconds will switch to the quick setting function. ? ? ? no. output operation emission amount setting timer d-on off non d-on on non d-on off ofd 10 ms d-on on ofd 10 ms d-on off ofd 40 ms d-on on ofd 40 ms d-on off ond 10 ms d-on on ond 10 ms d-on off ond 40 ms d-on on ond 40 ms l-on on ond 40 ms l-on off ond 40 ms l-on on ond 10 ms l-on off ond 10 ms l-on on ofd 40 ms l-on off ofd 40 ms l-on on ofd 10 ms l-on off ofd 10 ms l-on on non l-on off non others do not use during the initial transient time (0.5 sec.) after the power supply is switched on. eeprom is adopted to this product. it is not possible to conduct teaching 100 thousand times or more, because of the eeprom?s lifetime. ? ? precautions for proper use refer to p.986~ for general precautions, and to the ?operation guide? or ?sunx website? (http://www.sunx.com) for details pertaining to operating instructions for the ampli er. code 1st digit 2nd digit 3rd digit 4th digit output operation timer (note5) emission amount setting emission frequency eco extemal input shift (note5) fx-101 fx-102 d-on non off 01 off e_of 5 % ond 10 ms 12 limit [+] 10 % ond 40 ms 23 limit [?] 15 % ofd 10 ms 3 4 auto 20 % ofd 40 ms on 0 1 eco 25 % l-on non 1 2 on e_of 30 % ond 10 ms 23 limit [+] 35 % ond 40 ms 34 limit [?] 40 % ofd 10 ms auto 45 % ofd 40 ms eco 50 % notes: 1) when the present setting is out of the code setting range, ? ? is shown. when ? ? is selected, the set content of the digit is not changed. 2) the factory setting is ? ?.
digital fiber sensor fx-100 series 138 fiber sensors laser sensors photo- electric sensors micro photo- electric sensors area sensors safety components pressure sensors inductive proximity sensors particular use sensors sensor options wire- saving systems measure- ment sensors static control devices laser markers selection guide fiber sensor amplifiers fx-300 fx-100 fibers ft / fd / fr fx-410 fx-311 fx-11a fx-301-f other products fiber sensors fx-100 fiber sensor ampli ers dimensions (unit: mm in ) refer to p.106 ~ for ber dimensions. the cad data in the dimensions can be downloaded from the website: http://www.sunx.com 10 0.394 64.5 2.539 13.5 0.531 35 1.378 5.5 0.217 50 1.969 4.1 0.161 2 0.079 3 0.118 ?3.2 ?0.126 1.1 0.043 9 0.354 7 0.276 1 0.039 8.1 0.319 3.2 0.126 2.7 0.106 4 0.157 0.8 0.031 6 0.236 6 0.236 10.85 0.427 12.2 0.480 0.7 0.028 mode key on key / setting value up key off key / setting value down key operation indicator (orange) digital display (green, red) 29 1.142 47 1.850 30 1.181 10 0.394 ?6.5 ?0.256 suitable for 35 mm 1.378 in width din rail 4.1 0.161 2.7 0.106 0.8 0.031 6 0.236 6 0.236 20 0.787 47 1.850 29 1.142 12.2 0.480 0.7 0.028 mode key on key / setting value up key off key / setting value down key operation indicator (orange) digital display (green, red) fx-101 fx-102 ampli er fx-101 ( p ) -z fx-102 ( p ) -z ampli er 5 0.197 24.5 0.965 1 0.039 4 0.157 11.5 0.453 35 1.378 9 0.354 9.25 0.364 15 0.591 1 0.039 ?3.2 ?0.126 ?3.2 ?0.126 3.2 0.126 3.2 0.126 7.2 mm 0.283 in spot facing, 4 0.157 deep 6.2 mm 0.244 in spot facing, 3 0.118 deep ?7.2 mm ?0.283 in spot facing, 4 0.157 deep ?6.2 mm ?0.244 in spot facing, 3 0.118 deep 1.6 0.063 32 1.260 4 0.157 5.6 0.220 2.75 0.108 m3 (iength 18 mm 0.709 in ) pan head screws m3 square nut 24.7 0.972 15 0.591 3 0.118 3 0.118 60 2.362 suitable for 35 mm 1.378 in width din rail ms-din-4 amplifer mounting bracket (optional) ms-din-e end plate (optional) material: pbt material: polycarbonate ( ) ( ) ( ) ?3.7 ?0.146 cable 8 0.315 l 35 1.378 50 1.969 8 0.315 ( ) model no. length l cn-14a ( -r ) -c1 1,000 39.370 cn-14a ( -r ) -c2 2,000 78.740 cn-14a ( -r ) -c3 3,000 118.110 cn-14a ( -r ) -c5 5,000 196.850 cn-14a-c2 is attached fx-101 ( p ) -cc2 / fx-102 ( p ) -cc2 cn-14a-c cn-14a-r-c connector attached cable (optional) ? length l assembly dimensions with optional protective cover (fc-fx-1) 10 0.394 9 0.354 64.5 2.539 13.5 0.531 35 1.378 5.5 0.217 50 1.969 66.2 2.606 2 0.079 2 0.079 2 0.079 3 0.118 1.1 0.043 7 0.276 0.8 0.031 30 1.181 8.1 0.319 10 0.394 3.2 0.126 4 0.157 6 0.236 0.75 0.030 suitable for 35 mm 1.378 in width din rail ?3.2 ?0.126 0.8 0.031 1.1 0.043 10 0.394 7 0.276 9 0.354 4 0.157 5.5 0.217 13.5 0.531 50 1.969 35 1.378 64.5 2.539 2 0.079 3.2 0.126 8.1 0.319 10 0.394 30 1.181 1 0.039 suitable for 35 mm 1.378 in width din rail ?3.2 ?0.126 3 0.118


▲Up To Search▲   

 
Price & Availability of FT-NFM2S4

All Rights Reserved © IC-ON-LINE 2003 - 2022  

 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X