  chemelex, s.a. polgono industrial can castells. c/ industria, 113 nave j 08420 canovelles tel/ +34 93 849 17 35 fax/ +34 93 846 78 75 e-mail: chemelex@terra.es ed. 10.2002 airone 200 instrucciones de trabajo directions for use automatizacin automation labkit ? clinical diagnostic reagent free datasheet http:///
labkit airone 200 - albumine chemelex, s.a. polgono industrial can castells. c/ industria, 113 nave j 08420 canovelles tel/ +34 93 849 17 35 fax/ +34 93 846 78 75 e-mail: chemelex@terra.es ed. 10.2002 preparation of working reagent: the reagents are ready to use and keep stab le until date indicated on the label. calibration: use labtrol serum calibrator. operation conditions : introduce in methods the following programation. method method alb test definition name albumine units g/dl. decimals 0.0 reaction endpoint sample volume ( l) serum ( l) 3 plasma ( l) urine ( l) normal range ( l) technic r1 volume ( l) 500 r2 volume ( l) 0 abs. limit low 0 abs. limit high 400 filter 1 620 filter 2 none lineal limit 6.0 pollutant yes reagent blank yes diferential no time mix 1 0 mix 2 incubation 1 300 incubation 2 phase 2 measurement measurement type calibration calibrator factor normal range men women age min. max. min. max. less than 10 3.9 5.1 3.9 5.1 between 10-60 3.9 5.1 3.9 5.1 older than 60 3.9 5.1 3.9 5.1
labkit airone 200 ? urea berthelot chemelex, s.a. polgono industrial can castells. c/ industria, 113 nave j 08420 canovelles tel/ +34 93 849 17 35 fax/ +34 93 846 78 75 e-mail: chemelex@terra.es ed. 10.2002 preparation of working reagent: dissolve 1 tablet r3 into one bottle of buffer r1. the working reagent is stable 4 weeks at 2- 8oc. r2 is ready to use. calibration: use labtrol serum calibrator. operation conditions : introduce in methods the following programation. method method urea-b test definition name urea units mg/dl. decimals 0.0 reaction endpoint sample volume ( l) serum ( l) 3 plasma ( l) 3 urine ( l) 3 normal range ( l) technic r1 volume ( l) 250 r2 volume ( l) 250 abs. limit low 0 abs. limit high 400 filter 1 578 filter 2 none lineal limit 150 pollutant no reagent blank yes diferential no time mix 1 2 mix 2 1 incubation 1 300 incubation 2 240 phase 2 measurement measurement type calibration calibrator factor normal range men women agemin.max.min.max. less than 99 15.0 50.0 15.0 50.0 between older than
labkit airone 200 ? triglycerides chemelex, s.a. polgono industrial can castells. c/ industria, 113 nave j 08420 canovelles tel/ +34 93 849 17 35 fax/ +34 93 846 78 75 e-mail: chemelex@terra.es ed. 10.2002 preparation of working reagent: dissolve 1 vial lyophilised r2 with a little quantity of buffer r1. return to the original vial buffer when it is completely dissolved. the worki ng reagent is stable 28 days refrigerated and keep it out of the light. calibration: use labtrol serum calibrator. operation conditions : introduce in methods the following programation. method method trig. test definition name triglycerides units mg/dl. decimals 0.0 reaction endpoint sample volume ( l) serum ( l) 5 plasma ( l) 5 urine ( l) 3 normal range ( l) technic r1 volume ( l) 500 r2 volume ( l) 0 abs. limit low -25 abs. limit high 200 filter 1 510 filter 2 none lineal limit 1.000 pollutant no reagent blank yes diferential no time mix 1 0 mix 2 0 incubation 1 300 incubation 2 0 phase 2 measurement measurement type calibration calibrator factor normal range men women agemin.max.min.max. less than 10 30 150 30 150 between 10-60 30 150 30 150 older than 60 30 150 30 150
labkit airone 200 ? got/ast chemelex, s.a. polgono industrial can castells. c/ industria, 113 nave j 08420 canovelles tel/ +34 93 849 17 35 fax/ +34 93 846 78 75 e-mail: chemelex@terra.es ed. 10.2002 preparation of working reagent: dissolve 1 tablet r3 into one vial of buffer or one tablet with 15 ml. of buffer, depending of the presentation. the working reagent is stable 2 weeks. calibration: use labtrol serum calibrator. operation conditions : introduce in methods the following programation. method method got test definition name got/ast units u/l. decimals 0 reaction kinetic sample volume ( l) serum ( l) 45 plasma ( l) 45 urine ( l) 0 normal range ( l) technic r1 volume ( l) 450 r2 volume ( l) 0 abs. limit low 900 abs. limit high 2000 filter 1 340 filter 2 none lineal limit 250 pollutant no reagent blank no diferential no time mix 1 2 mix 2 incubation 1 60 incubation 2 phase 10 measurement 30 measurement type calibration factor factor normal range men women agemin.max.min.max. less than 10 0 38 0 38 between 10-60 0 38 0 38 older than 60 0 38 0 38
labkit airone 200 - glucose chemelex, s.a. polgono industrial can castells. c/ industria, 113 nave j 08420 canovelles tel/ +34 93 849 17 35 fax/ +34 93 846 78 75 e-mail: chemelex@terra.es ed. 10.2002 preparation of working reagent: dissolve 1 vial lyophilised r2 with a little quantity of buffer r1. return to the original vial buffer when it is completely dissolved. the working reagent is stable 1 month refrigerated and keep it out of the light. calibration: use labtrol serum calibrator. operation conditions : introduce in methods the following programation. method method glu. test definition name glucose units mg/dl. decimals 0 reaction endpoint sample volume ( l) serum ( l) 5 plasma ( l) 5 urine ( l) 3 normal range ( l) technic r1 volume ( l) 500 r2 volume ( l) 0 abs. limit low -25 abs. limit high 200 filter 1 510 filter 2 none lineal limit 500 pollutant no reagent blank yes diferential no time mix 1 0 mix 2 incubation 1 600 incubation 2 phase 2 measurement measurement type calibration calibrator factor normal range men women agemin.max.min.max. less than 10 55 110 55 110 between 10-60 55 110 55 110 older than 60 55 110 55 110
labkit airone 200 - creatinine chemelex, s.a. polgono industrial can castells. c/ industria, 113 nave j 08420 canovelles tel/ +34 93 849 17 35 fax/ +34 93 846 78 75 e-mail: chemelex@terra.es ed. 10.2002 preparation of working reagent: the reagents are ready to use and keep stable until date indicated on the label. calibration: use labtrol serum calibrator. operation conditions : introduce in methods the following programation. method method crea test definition name creatinine units mg/dl. decimals 0.0 reaction fixed time sample volume ( l) serum ( l) 45 plasma ( l) 45 urine ( l) 10 normal range ( l) technic r1 volume ( l) 225 r2 volume ( l) 225 abs. limit low 0 abs. limit high 800 filter 1 492 filter 2 none lineal limit 15.0 pollutant yes reagent blank no diferential no time mix 1 2 mix 2 2 incubation 1 10 incubation 2 60 phase 10 measurement 30 measurement type calibration calibration factor normal range men women agemin.max.min.max. less than 10 0.8 1.4 0.7 1.4 between 10-60 0.8 1.4 0.7 1.4 older than 60 0.8 1.4 0.7 1.4
labkit airone 200 ? ck nac bireagent chemelex, s.a. polgono industrial can castells. c/ industria, 113 nave j 08420 canovelles tel/ +34 93 849 17 35 fax/ +34 93 846 78 75 e-mail: chemelex@terra.es ed. 10.2002 preparation of working reagent: dissolve 1 tablet (r2) with 25 ml. of buffer (r 1). it is stable 21 days at 2-8oc or 5 days at 15- 25oc. dissolve 1 tablet (r3) with 5 ml. of r4. it is stable 6 weeks at 2-8oc or 7 days at 15-25oc. operation conditions : introduce in methods the following programation. method method ck-nac test definition name ck-nac units u/l. decimals 0 reaction kinetic sample volume ( l) serum ( l) 9 plasma ( l) 9 urine ( l) 3 normal range ( l) technic r1 volume ( l) 450 r2 volume ( l) 45 abs. limit low 0 abs. limit high 2000 filter 1 340 filter 2 none lineal limit 2000 pollutant no reagent blank no diferential no time mix 1 1 mix 2 1 incubation 1 120 incubation 2 120 phase 2 measurement 90 measurement type calibration factor factor 9003 normal range men women agemin.max.min.max. less than 10 24 195 24 170 between 10-60 24 195 24 170 older than 60 24 195 24 170
labkit airone 200 ? ck nac chemelex, s.a. polgono industrial can castells. c/ industria, 113 nave j 08420 canovelles tel/ +34 93 849 17 35 fax/ +34 93 846 78 75 e-mail: chemelex@terra.es ed. 10.2002 preparation of working reagent: dissolve 1 tablet (r2) with 1 vial of buffer (r1) , or with 15 ml. of buffer (r1) depending of the presentation. the monoreagent is stable 5 days at 2-8oc or 24 hours at room temperature. operation conditions : introduce in methods the following programation. method method ck-nac test definition name ck-nac units u/l. decimals 0 reaction kinetic sample volume ( l) serum ( l) 15 plasma ( l) 15 urine ( l) 3 normal range ( l) technic r1 volume ( l) 500 r2 volume ( l) 0 abs. limit low 0 abs. limit high 700 filter 1 340 filter 2 none lineal limit 2000 pollutant no reagent blank no diferential no time mix 1 2 mix 2 incubation 1 150 incubation 2 phase 10 measurement 60 measurement type calibration factor factor 5450 normal range men women agemin.max.min.max. less than 10 24 195 24 170 between 10-60 24 195 24 170 older than 60 24 195 24 170
labkit airone 200 ? ck - mb chemelex, s.a. polgono industrial can castells. c/ industria, 113 nave j 08420 canovelles tel/ +34 93 849 17 35 fax/ +34 93 846 78 75 e-mail: chemelex@terra.es ed. 10.2002 preparation of working reagent: dissolve 1 tablet (r2) with 1 vial of buffer (r1. the monoreagent is stable 7 days at 2-8oc or 12 hours at room temperature. operation conditions : introduce in methods the following programation. method method ck-mb test definition name ck-mb units u/l. decimals 0.0 reaction kinetic sample volume ( l) serum ( l) 20 plasma ( l) 20 urine ( l) 3 normal range ( l) technic r1 volume ( l) 500 r2 volume ( l) 0 abs. limit low 0 abs. limit high 600 filter 1 340 filter 2 none lineal limit 1000 pollutant no reagent blank yes diferential no time mix 1 2 mix 2 incubation 1 600 incubation 2 phase 20 measurement 60 measurement type calibration factor factor 8255 normal range men women agemin.max.min.max. less than 99 0.0 24.0 0.0 24.0 between older than
labkit airone 200 ? calcium arsenazo iii chemelex, s.a. polgono industrial can castells. c/ industria, 113 nave j 08420 canovelles tel/ +34 93 849 17 35 fax/ +34 93 846 78 75 e-mail: chemelex@terra.es ed. 10.2002 preparation of working reagent: the reagents are ready to use and keep stable until date indicated on the label. calibration: use labtrol serum calibrator. operation conditions : introduce in methods the following programation. method method cal-a test definition name calcium units mg/dl. decimals 0.0 reaction endpoint sample volume ( l) serum ( l) 5 plasma ( l) -- urine ( l) 3 normal range ( l) technic r1 volume ( l) 500 r2 volume ( l) 0 abs. limit low 0 abs. limit high 700 filter 1 620 filter 2 none lineal limit 30.0 pollutant yes reagent blank yes diferential no time mix 1 1 mix 2 incubation 1 120 incubation 2 phase 2 measurement measurement type calibration calibrator factor normal range men women agemin.max.min.max. less than 1 8.0 13.0 8.0 13.0 between 1-12 10.0 12.0 10.0 12.0 older than 12 9.5 11.0 9.5 11.0
labkit airone 200 - calcium chemelex, s.a. polgono industrial can castells. c/ industria, 113 nave j 08420 canovelles tel/ +34 93 849 17 35 fax/ +34 93 846 78 75 e-mail: chemelex@terra.es ed. 10.2002 preparation of working reagent: the reagents are ready to use and keep stable until date indicated on the label. calibration: use labtrol serum calibrator. operation conditions : introduce in methods the following programation. method method calcium test definition name calcium units mg/dl. decimals 0.0 reaction endpoint sample volume ( l) serum ( l) 5 plasma ( l) -- urine ( l) 3 normal range ( l) technic r1 volume ( l) 250 r2 volume ( l) 250 abs. limit low 0 abs. limit high 600 filter 1 578 filter 2 none lineal limit 15.0 pollutant yes reagent blank yes diferential no time mix 1 1 mix 2 3 incubation 1 30 incubation 2 120 phase 2 measurement measurement type calibration calibrator factor normal range men women agemin.max.min.max. less than 1 8.0 13.0 8.0 13.0 between 1-12 10.0 12.0 10.0 12.0 older than 12 9.0 11.0 9.0 11.0
labkit airone 200 ? total bilirubin chemelex, s.a. polgono industrial can castells. c/ industria, 113 nave j 08420 canovelles tel/ +34 93 849 17 35 fax/ +34 93 846 78 75 e-mail: chemelex@terra.es ed. 10.2002 preparation of working reagent: mix 3 ml. with 0.1 ml. r2 sodium nitrite, to prepare the working rea gents. this monoreagent is stable 2 days at 2-8oc. calibration: use labtrol serum calibrator. operation conditions : introduce in methods the following programation. method method bil. t test definition name total bilirubin units mg/dl. decimals 0.0 reaction endpoint sample volume ( l) serum ( l) 30 plasma ( l) 30 urine ( l) normal range ( l) technic r1 volume ( l) 500 r2 volume ( l) 0 abs. limit low -50 abs. limit high 400 filter 1 546 filter 2 none lineal limit 20 pollutant no reagent blank yes diferential no time mix 1 1 mix 2 incubation 1 300 incubation 2 phase 2 measurement measurement type calibration calibrator factor normal range men women agemin.max.min.max. less than 1 0.0 10.0 0.0 10.0 between 1-99 0.0 1.1 0.0 1.1 older than
labkit airone 200 ? direct bilirubin chemelex, s.a. polgono industrial can castells. c/ industria, 113 nave j 08420 canovelles tel/ +34 93 849 17 35 fax/ +34 93 846 78 75 e-mail: chemelex@terra.es ed. 10.2002 preparation of working reagent: mix 3 ml. with 0.1 ml. r2 sodium nitrite, to prepare the working rea gents. this monoreagent is stable 2 days at 2-8oc. calibration: use labtrol serum calibrator. operation conditions : introduce in methods the following programation. method method bil. d test definition name direct bilirubin units mg/dl. decimals 0.0 reaction endpoint sample volume ( l) serum ( l) 30 plasma ( l) 30 urine ( l) 3 normal range ( l) technic r1 volume ( l) 500 r2 volume ( l) 0 abs. limit low -50 abs. limit high 400 filter 1 546 filter 2 none lineal limit 20 pollutant no reagent blank yes diferential no time mix 1 2 mix 2 incubation 1 300 incubation 2 phase 2 measurement measurement type calibration calibrator factor normal range men women agemin.max.min.max. less than 99 0.0 0.4 0.0 0.4 between older than
labkit airone 200 - amylase chemelex, s.a. polgono industrial can castells. c/ industria, 113 nave j 08420 canovelles tel/ +34 93 849 17 35 fax/ +34 93 846 78 75 e-mail: chemelex@terra.es ed. 10.2002 preparation of working reagent: dissolve 1 tablet (r2) with 1 vial of buffer (r1) , or with 15 ml. of buffer (r1) depending of the presentation. the monoreagent is stable 15 day s at 2-8oc or 2 days at room temperature. operation conditions : introduce in methods the following programation. method method amil test definition name amylase units u/l. decimals 0 reaction kinetic sample volume ( l) serum ( l) 12 plasma ( l) 12 urine ( l) 6 normal range ( l) technic r1 volume ( l) 500 r2 volume ( l) 0 abs. limit low 900 abs. limit high 2000 filter 1 405 filter 2 none lineal limit 1000 pollutant no reagent blank no diferential no time mix 1 0 mix 2 0 incubation 1 60 incubation 2 0 phase 10 measurement 30 measurement type calibration factor factor 5338 normal range men women agemin.max.min.max. less than 10 0 90 0 90 between 10-60 0 90 0 90 older than 60 0 90 0 90
labkit airone 200 ? uric acid chemelex, s.a. polgono industrial can castells. c/ industria, 113 nave j 08420 canovelles tel/ +34 93 849 17 35 fax/ +34 93 846 78 75 e-mail: chemelex@terra.es ed. 10.2002 preparation of working reagent: dissolve 1 vial lyophilised r2 with a little quantity of buffer r1. return to the original vial buffer when it is completely dissolved. the wo rking reagent is stable 3 weeks at 2-8oc. calibration: use labtrol serum calibrator. operation conditions : introduce in methods the following programation. method method uric test definition name uric acid units mg/dl. decimals 0.0 reaction endpoint sample volume ( l) serum ( l) 12 plasma ( l) 12 urine ( l) 3 normal range ( l) technic r1 volume ( l) 500 r2 volume ( l) 0 abs. limit low -50 abs. limit high 200 filter 1 510 filter 2 none lineal limit 25.0 pollutant no reagent blank yes diferential no time mix 1 0 mix 2 incubation 1 240 incubation 2 phase 2 measurement measurement type calibration calibrator factor normal range men women agemin.max.min.max. less than 10 3.4 7.0 2.5 6.0 between 10-60 3.4 7.0 2.5 6.0 older than 60 3.4 7.0 2.5 6.0


▲Up To Search▲   

 
Price & Availability of AIRONE200

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X