06-2013, rev. 0613 www.te.com ? 2013 tyco electronics corporation, a te connectivity ltd. company datasheets and product specifcation according to iec 61810-1 and to be used only together with the defnitions section. datasheets and product data is subject to the terms of the disclaimer and all chapters of the defnitions section, available at http://relays.te.com/definitions datasheets, product data, defnitions sec - tion, application notes and all specifcations are subject to change. 1 rf signal relays n y-design n frequency range dc to 3ghz n impedance 50 or 75 n small dimensions (14.6x7.2x10mm) n 1 form c contact (1 changeover contact) n immersion cleanable n low power consumption (140mw) typical applications cable modems and linecards/ catv, tabs, measurement and test equipment ate, satellite / audio / video tuners, wireless base stations and antennas, switching boards contact data contact arrangement 1 form c, 1 co max. switching voltage 220vdc, 250vac rated current 2a limiting continuous current, 23c 2a switching power 60w, 62.5va, 50w (2.5ghz) max. continuos rf-power, 23c 50w (2.5ghz) contact material ag, au covered minimum switching voltage 100v initial contact resistance <100m? at 10ma, 20mv operate time typ. 3ms, max. 5ms release time without diode in parallel typ. 2ms, max. 5ms with diode in parallel typ. 4ms, max. 6ms bounce time typ. 1ms, max. 3ms duration of set/reset pulse min. 20ms mechanical endurance 10 7 operations coil data coil voltage range 3 to 24vdc coil versions, monostable coil rated operate limiting release coil rated coil code voltage voltage voltage voltage resistance power vdc vdc vdc vdc ?10% mw 50 version, monostable, 1 coil 51 3 2.25 6.50 0.30 64 140 52 4.5 3.38 9.80 0.45 145 140 53 5 3.75 10.90 0.50 178 140 54 6 4.50 13.00 0.60 257 140 55 9 6.75 19.60 0.90 574 140 56 12 9.00 26.10 1.20 1028 140 57 24 18.00 52.30 2.40 4114 140 75 version, monostable, 1 coil 01 3 2.25 6.50 0.30 64 140 02 4.5 3.38 9.80 0.45 145 140 03 5 3.75 10.90 0.50 178 140 04 6 4.50 13.00 0.60 257 140 05 9 6.75 19.60 0.90 574 140 06 12 9.00 26.10 1.20 1028 140 07 24 18.00 52.30 2.40 4114 140 all fgures are given for coil without pre-energization, at ambient temperature +23c. coil data (continued) coil versions, bistable coil rated set limiting reset coil rated coil code voltage voltage voltage voltage resistance power vdc vdc vdc vdc ?10% mw 50 version, bistable, 1 coil 71 3 2.25 9.20 -2.25 128 70 72 4.5 3.38 13.85 -3.38 289 70 73 5 3.75 15.30 -3.75 357 70 74 6 4.50 18.50 -4.50 514 70 75 9 6.75 27.70 -6.75 1157 70 76 12 9.00 37.00 -9.00 2057 70 77 24 18.00 74.00 -18.00 8228 70 50 version, bistable, 2 coils 91 3 2.25 6.50 2.25 64 140 92 4.5 3.38 9.80 3.38 145 140 93 5 3.75 10.90 3.75 178 140 94 6 4.50 13.00 4.50 257 140 95 9 6.75 19.60 6.75 574 140 96 12 9.00 26.10 9.00 1028 140 97 24 18.00 52.30 18.00 4114 140 all fgures are given for coil without pre-energization, at ambient temperature +23c. coil data (continued) coil versions, bistable coil rated set limiting reset coil rated coil code voltage voltage voltage voltage resistance power vdc vdc vdc vdc ?10% mw 75 version, bistable, 1 coil 21 3 2.25 9.20 -2.25 128 70 22 4.5 3.38 13.85 -3.38 289 70 23 5 3.75 15.30 -3.75 357 70 24 6 4.50 18.50 -4.50 514 70 25 9 6.75 27.70 -6.75 1157 70 26 12 9.00 37.00 -9.00 2057 70 27 24 18.00 74.00 -18.00 8228 70 75 version, bistable, 2 coils 41 3 2.25 6.50 2.25 64 140 42 4.5 3.38 9.80 3.38 145 140 43 5 3.75 10.90 3.75 178 140 44 6 4.50 13.00 4.50 257 140 45 9 6.75 19.60 6.75 574 140 46 12 9.00 26.10 9.00 1028 140 47 24 18.00 52.30 18.00 4114 140 all fgures are given for coil without pre-energization, at ambient temperature +23c. hf3 relay axicom
06-2013, rev. 0613 www.te.com ? 2013 tyco electronics corporation, a te connectivity ltd. company datasheets and product specifcation according to iec 61810-1 and to be used only together with the defnitions section. datasheets and product data is subject to the terms of the disclaimer and all chapters of the defnitions section, available at http://relays.te.com/definitions datasheets, product data, defnitions sec - tion, application notes and all specifcations are subject to change. 2 rf signal relays hf3 relay (continued) rf data isolation at 100mhz/900mhz 80db/72db 80db/72db at 3ghz 45db 40db insertion loss at 100mhz/900mhz 0.03db/0.12db 0.03db/0.12db at 3ghz 0.35db 0.40db voltage standing wave ratio (vswr) at 100mhz/900mhz/3ghz 1.05/1.20/1.20 1.05/1.20/1.40 other data material compliance: eu rohs/elv, china rohs, reach, halogen content refer to the product compliance support center at www.te.com/customersupport/rohssupportcenter ambient temperature -55c to +85c thermal resistance <165k/w category of environmental protection iec 61810 rt iii - wash tight degree of protection, iec 60529 ip 67, immersion cleanable vibration resistance (functional) 35g, 10 to 1000hz shock resistance (functional), half sinus 11ms 50g shock resistance (destructive), half sinus 0.5ms 150g terminal type smt weight max. 2.5g resistance to soldering heat smt iec 60068-2-58 265c/10s moisture sensitive level, jedec j-std-020d msl3 ultrasonic cleaning not recommended packaging/unit reel/400 pcs., box/400 or 2000 pcs. insulation data 50 version 75 version initial dielectric strength between open contacts 600v rms between contact and coil 1000v rms initial surge withstand voltage between open contacts 1000v between contact and coil 1500v 108-98000 rev. f all speci?cations subject to change. consult t yco electronics for latest speci?cations. 5 of 12 t elecom-, signal and rf relays hf3 rela y axicom u max. at 0 a u op. min. u rel. min. 140 mw coil voltage [u/u nom ] ambient temperature [c] t erminal assignment relay top view non-lat ching type , not energized condition lat ching type, 2 co ils reset condition lat ching type, 1 c oil rest condition coil ope ra ting range 0 0.5 1 1.5 2 2.5 3 3.5 -55- 45 -35- 25 -15- 55 15 25 35 45 55 65 75 85 95 1051 15 1251 35 u nom. nominal coil voltage u max. at 0 a u op. min. 70 mw coil voltage [u/u nom ] ambient temperature [c] u nom. nominal coil voltage unom = nominal coil voltage umax. = upper limit of the operative range of the coil voltage (limiting voltage) u op. min. = lower limit of the operative range of the coil voltage (reliable operate voltage) for latching relays uset min. resp. ureset min. u rel. min. = lower limit of the operative range of the coil voltage (reliable release voltage) 140 mw 70 mw contacts in reset position. contact po - sition might change during transporta - tion and must be reset before use. 108-98000 rev. f all speci?cations subject to change. consult t yco electronics for latest speci?cations. 5 of 12 t elecom-, signal and rf relays hf3 rela y axicom u max. at 0 a u op. min. u rel. min. 140 mw coil voltage [u/u nom ] ambient temperature [c] t erminal assignment relay top view non-lat ching type , not energized condition lat ching type, 2 co ils reset condition lat ching type, 1 c oil rest condition coil ope ra ting range 0 0.5 1 1.5 2 2.5 3 3.5 -55- 45 -35- 25 -15- 55 15 25 35 45 55 65 75 85 95 1051 15 1251 35 u nom. nominal coil voltage u max. at 0 a u op. min. 70 mw coil voltage [u/u nom ] ambient temperature [c] u nom. nominal coil voltage unom = nominal coil voltage umax. = upper limit of the operative range of the coil voltage (limiting voltage) u op. min. = lower limit of the operative range of the coil voltage (reliable operate voltage) for latching relays uset min. resp. ureset min. u rel. min. = lower limit of the operative range of the coil voltage (reliable release voltage) 140 mw 70 mw contacts in reset position. contact po - sition might change during transporta - tion and must be reset before use. coil operating range axicom
06-2013, rev. 0613 www.te.com ? 2013 tyco electronics corporation, a te connectivity ltd. company datasheets and product specifcation according to iec 61810-1 and to be used only together with the defnitions section. datasheets and product data is subject to the terms of the disclaimer and all chapters of the defnitions section, available at http://relays.te.com/definitions datasheets, product data, defnitions sec - tion, application notes and all specifcations are subject to change. 3 rf signal relays hf3 relay (continued) no nc -0.4 -0.3 -0.2 -0.1 0.0 0.1 0 500 1000 1500 2000 2500 3000 frequency [mhz] insertion-loss [db] typical rf performance, 50? version (continued) typical rf performance, 75? version (continued) no nc -0.4 -0.3 -0.2 -0.1 0.0 0.1 0 500 1000 1500 2000 2500 frequency [mhz] insertion-loss [db] no nc 1.00 1.05 1.10 1.15 1.20 1.25 0 500 1000 1500 2000 2500 3000 frequency[mhz] vswr no nc 1.00 1.05 1.10 1.15 1.20 1.25 0 500 1000 1500 2000 2500 frequency[mhz] vswr terminal assignment top view on component side of pcb monostable bistable, 1 coil contacts are shown in reset condition. contact position might change during transportation and must be reset before use. bistable, 2 coils 1 12 2 3 4 5 6 7 8 9 10 11 13 14 15 16 17 18 19 20 21 22 hf3-pin-2spulen + - + - reset set + - + - reset set no nc -120 -100 -80 -60 -40 -20 0 0 500 1000 1500 2000 2500 3000 frequency [mhz] isolation [db] typical rf performance, 50? version typical rf performance, 75? version nc no -120 -100 -80 -60 -40 -20 0 0 500 1000 1500 2000 2500 frequency [mhz] isolation [db] axicom
06-2013, rev. 0613 www.te.com ? 2013 tyco electronics corporation, a te connectivity ltd. company datasheets and product specifcation according to iec 61810-1 and to be used only together with the defnitions section. datasheets and product data is subject to the terms of the disclaimer and all chapters of the defnitions section, available at http://relays.te.com/definitions datasheets, product data, defnitions sec - tion, application notes and all specifcations are subject to change. 4 rf signal relays hf3 relay (continued) pcb layout top view on component side of pcb 50? version 75? version dimensions 50? version 75? version 1 plc 0 plc 2 plc 3 plc 4 plc dimensions: tolerances unless otherwise specified: angles weight application spec product spec of material finish dwn chk apvd name size cage code drawing no scale sheet rev loc dist released for publication c copyright all rights reserved. this drawing is unpublished. revisions p ltr date dwn apvd description 1469-35 (3/11) a4 restricted to this drawing is a controlled document. te connectivity a 7.2 +0.1 -0.1 14.6 +0.1 -0.1 0.9 +0.1 -0.1 0.4 0.8 0.8 0.8 0.8 3.81 +0.1 -0.1 3.81 +0.1 -0.1 0.5 6.35 +0.15 -0.15 6.35 +0.15 -0.15 9.4 +0.2 -0.2 5.08 +0.1 -0.1 5.08 +0.1 -0.1 4.9 10 +0.5 0 3 2 2.54 +0.1 -0.1 2.54 +0.1 -0.1 5.08 +0.1 -0.1 5.08 +0.1 -0.1 1.27 +0.1 -0.1 1.27 +0.1 -0.1 0.95 6.7 5 6 10 7.2 0.9 0.9 0.9 0.7 0.9 0.7 0.9 0.95 14.6 0.9 1.27 2.54 xx = relay type zz = nominal voltage yyww = date code nnnn = lot number 0.1 a 1 12 2 3 4 5 6 7 8 9 10 11 13 14 15 16 17 18 19 20 21 22 relay housing a-a c printing 21jul2009 uko hd d printing 09jul2010 uko hd d1 reviesed per eco-11-005150 09jul2010 rk hmr d2 revised per eco-11-017072 (ecr-13-009645) 14jun2013 uko ak hj - 2005 2005 by te connectivity 16aug2002 mm uko 9193 - - 16aug2002 hd 9121 16aug2002 din 7168-m hd 9121 - - hf3-relay 50 - - - dimensions - 1 - - 00779 1462051-2 - customer drawing 3:1 1 1 d2 coplanarity<=0.10mm drawing alias: h2000-dok02 1 plc 0 plc 2 plc 3 plc 4 plc dimensions: tolerances unless otherwise specified: angles weight application spec product spec of material finish dwn chk apvd name size cage code drawing no scale sheet rev loc dist released for publication c copyright all rights reserved. this drawing is unpublished. revisions p ltr date dwn apvd description 1469-35 (3/11) a4 restricted to this drawing is a controlled document. te connectivity a 7.2 +0.1 -0.1 14.6 +0.1 -0.1 0.9 +0.1 -0.1 0.4 0.8 0.8 0.5 0.5 3.81 +0.1 -0.1 3.81 +0.1 -0.1 0.5 6.35 +0.15 -0.15 6.35 +0.15 -0.15 9.4 +0.2 -0.2 5.08 +0.1 -0.1 5.08 +0.1 -0.1 4.9 10 +0.5 0 3 2 2.54 +0.1 -0.1 2.54 +0.1 -0.1 5.08 +0.1 -0.1 5.08 +0.1 -0.1 1.27 +0.1 -0.1 1.27 +0.1 -0.1 0.95 6.7 5 6 10 7.2 0.5 0.9 0.5 0.7 0.9 0.6 0.9 0.95 14.6 0.5 1.27 2.54 xx = relay type zz = nominal voltage yyww = date code nnnn = lot number 0.1 a 1 12 2 3 4 5 6 7 8 9 10 11 13 14 15 16 17 18 19 20 21 22 relay housing a-a c printing 21jul2009 uko hd d printing 09jul2010 uko hd d1 revised per eco-11-005150 25mar2011 uko hmr d2 revised per eco-11-017072 (ecr-13-009645) 14jun2013 uko ak hj - 2005 2005 by te connectivity 16aug2002 mm uko 9193 - - 16aug2002 hd 9121 16aug2002 din 7168-m hd 9121 - - hf3-relay 75 - - - dimensions - - - - 00779 1462050-2 - customer drawing 3:1 1 1 d2 coplanarity<=0.10mm axicom
06-2013, rev. 0613 www.te.com ? 2013 tyco electronics corporation, a te connectivity ltd. company datasheets and product specifcation according to iec 61810-1 and to be used only together with the defnitions section. datasheets and product data is subject to the terms of the disclaimer and all chapters of the defnitions section, available at http://relays.te.com/definitions datasheets, product data, defnitions sec - tion, application notes and all specifcations are subject to change. 5 rf signal relays hf3 relay (continued) processing full line: typical dotted line: pr ocess limits exter nal pr eheating 240c 180c 130c 100c for ced cooling 20 to 40s t ime [s] t emperatur e [c] v apour phase soldering temperatur e/time pr o?le (lead and housing peak temp.) recommended soldering conditions v apour phase soldering t ime [s] t emperatur e [c] recommended r e?ow soldering pr o?le infrar ed soldering temperatur e/time pr o?le (lead and housing peak temp.) t ime [s] t emperatur e [c] resistance to soldering heat infrar ed soldering temperatur e/time pr o?le (lead and housing peak temp.) packing tape and reel for smt reel dimensions axicom
06-2013, rev. 0613 www.te.com ? 2013 tyco electronics corporation, a te connectivity ltd. company datasheets and product specifcation according to iec 61810-1 and to be used only together with the defnitions section. datasheets and product data is subject to the terms of the disclaimer and all chapters of the defnitions section, available at http://relays.te.com/definitions datasheets, product data, defnitions sec - tion, application notes and all specifcations are subject to change. 6 rf signal relays hf3 relay (continued) product code structure typical product code hf3 53 type hf3 signal relays hf3 series 1 form c, 1 co coil coil code: please refer to coil versions table performance type 5x 50? version, monostable 1coil 0x 75? version, monostable 1coil 7x 50? version, bistable 1coil 2x 75? version, bistable 1coil 9x 50? version, bistable 2coils 4x 75? version, bistable 2coils product code arrangement version coil coil type part number hf3 51 1 form c (1 co) 50ohm 3vdc monostable 1462051-1 hf3 52 4.5vdc 1-1462051-6 hf3 53 5vdc 1462051-2 hf3 54 6vdc 1-1462051-7 hf3 55 9vdc 1462051-3 hf3 56 12vdc 1462051-4 hf3 57 24vdc 1462051-5 hf3 71 1 form c (1 co) 50ohm 3vdc bistable 1 coil 1462051-6 hf3 72 4.5vdc 1-1462051-8 hf3 73 5vdc 1462051-7 hf3 76 12vdc 1462051-9 hf3 91 1 form c (1 co) 50ohm 3vdc bistable 2 coils 1-1462051-1 hf3 92 4.5vdc 2-1462051-0 hf3 93 5vdc 1-1462051-2 hf3 95 9vdc 1-1462051-3 hf3 96 12vdc 1-1462051-4 hf3 97 24vdc 1-1462051-5 hf3 01 1 form c (1 co) 75ohm 3vdc monostable 1462050-1 hf3 02 4.5vdc 1-1462050-6 hf3 03 5vdc 1462050-2 hf3 06 12vdc 1462050-4 hf3 07 24vdc 1462050-5 hf3 21 1 form c (1 co) 75ohm 3vdc bistable 1 coil 1462050-6 hf3 23 5vdc 1462050-7 hf3 26 12vdc 1462050-9 hf3 41 1 form c (1 co) 75ohm 3vdc bistable 2 coils 1-1462050-1 hf3 43 5vdc 1-1462050-2 hf3 46 12vdc 1-1462050-4 hf3 47 24vdc 1-1462050-5 this list represents the most common types and does not show all variants covered by this data sheet. other types on request axicom
|