iec inlet filters f.bn series general purpose modules a comprehensive range of chassis mount iec 60320 inlet power entry modules housed in a compact and lightweight enclosure. offers a low cost form of protection from mains borne interference in applications such as business, consumer, medical equipment, vdu?, computers, vending machines and many other general purpose applications. current ratings from 1a to 10a component value combinations to suit requirements low cost design medical versions available approvals filter range code l r lcxcy i l circ (a) (mh) (f) (pf) (ma) diag f.bn.ab.2100.ze.200 6 2x0.5 0.01 2x2700 2x0.25 a f.bn.ab.2470.za.100 1 2x2.8 0.047 2x2200 2x0.2 a f.bn.ab.2470.zb.000 1 2x10 0.047 2x2500 2x0.23 a f.bn.ab.2470.zd.000 3 2x2.5 0.047 2x2500 2x0.23 a f.bn.ab.2470.zf.000 6 2x1 0.047 2x2500 2x0.23 a f.bn.ab.2470.zg.110 10 2x0.13 0.047 2x2200 2x0.2 a f.bn.ab.2680.cz.300 3 2x1 0.068 2x3300 2x0.3 b f.bn.ab.2680.zb.000 1 2x10 0.068 2x2500 2x0.23 a f.bn.ab.2680.zd.000 3 2x2.5 0.068 2x2500 2x0.23 a f.bn.ab.2680.zf.000 6 2x1 0.068 2x2500 2x0.23 a f.bn.ab.3100.bz.000 1 2x10 0.1 2x2500 2x0.23 b f.bn.ab.3100.dz.000 3 2x2.5 0.1 2x2500 2x0.23 b f.bn.ab.3100.fz.000 6 2x1 0.1 2x2500 2x0.23 b f.bn.ab.3100.hz.420 3 2x6 0.1 2x150 2x0.014 b electrical specifications rated voltage (v r ): max 250v, 50/60hz rated current (i r ): r eferred to room temperature = 40? leakage current (i l ): at 220v, 50hz, max value voltage test (2 s .): line to ground 3000vdc or 1800vac line to line 1700vdc climatic category: hpf (25/085/21): t emperature range: -25? to +85? mechanical specifications manufacture: metal case with built-in power line connector according to iec 60320 & en 60320. connections: iec 60320 - standard plug (input); faston 2x2.8 x 0.8mm or 6.3 x 0.8mm (output); ground terminal connected to case. dimensions (mm) and connections circuit diagram available variants a b f. bn. - -. - - - -. - -. - - 0 a = 2x2.8mm x 0.8 faston b = 6.3mm x 0.8 faston a = standard version m = medical version (without y capacitors) x capacitance 2100 = 0.010uf 2470 = 0.047uf 2680 = 0.068uf 3100 = 0.1uf y capacitance current leakage 0 = 2500pf 2x0.23 ma 1 = 2200pf 2x0.20 ma 2 = 2700pf 2x0.25 ma 3 = 3300pf 2x0.3 ma 4 = 150pf 2x0.014 ma resistor 0 = no resistor 1 = 1m ? 2 = 2.2m ? i r , l & cct. cct a cct b values za az 1a, 2.8mh, zb bz 1a, 10mh, zc cz 3a, 1mh zd dz 3a, 2.5mh ze ez 6a, 0.5mh zf fz 6a, 1mh zg gz 10a, 0.13mh zh hz 3a, 6mh 22
23 0 10 20 30 40 50 60 70 80 90 100 .01 .1 1 10 100 .15 30 mhz db ?470.za ?470.zd ?470.zf ?680.zd ?680.zf ?100.ze ?680.cz ?470.zb ...3100dz ...3100fz ?100.bz ?680.zb ...2470.zg iec inlet filters f.bn series insertion loss (typical): asymmetrical (line to ground) ??? symmetrical (line to line) ?100.hz
|