Part Number Hot Search : 
0BZXC 0M350 KR3803X L101G MJF47 FESP05JA OPB780Z 79L12
Product Description
Full Text Search
 

To Download E5CN-CMT-500 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  1 1 digital temperature controllers/digital controllers e5 @ n/e5 @ n-h upgraded 1/16, 1/8, and 1/4 din co ntrollers, the best-selling e5 @ n series. basic type (renewal e5 @ n) and advanced type (new e5 @ n-h). ? improved indication accuracy and preventive maintenance (basic type e5 @ n).  new high-performance controllers (advanced type e5 @ n-h).  easy-to-use one-touch operation with pf key (only for 1/8 and 1/4 din).  logic operations. e5cn basic type (renewal e5 @ n) advanced type (new e5 @ n-h) e5en e5an e5cn-h e5en-h e5an-h 1/16 din 1/8 din 1/4 din 1/16 din 1/8 din 1/4 din e5 @ n series
2 contents digital temperature controllers e5cn/e5cn-u ............................................. 3 e5an/e5en ................................................. 17 digital controllers e5cn-h........................................................ 31 e5an-h/e5en-h.......................................... 43 operation procedure ? operation ..................................................... 58 common to all controllers  safety precautions ....................................... 66 cx-thermo support software  est2-2c-mv4.............................................. 70
e5cn e5cn-u (48 x 48 mm) e5an (96 x 96 mm) e5en (48 x 96 mm) e5cn-h (48 x 48 mm) e5an-h (96 x 96 mm) e5en-h (48 x 96 mm) operation safety precautions 3 basic-type digital temperature controller e5cn/e5cn-u (48 x 48 mm) new 48 x 48-mm basic temperature controller with enha nced functions and performance. improved indication accuracy and preventive maintenance function. ? indication accuracy thermocouple input: 0.3% of pv (previous models: 0.5%) pt input: 0.2% of pv (previous models: 0.5%) analog input: 0.2% fs (previous models: 0.5%) ? new e5cn-u models (plug-in models) with analog inputs and current outputs. ? a pv/sv-status display function can be set to automatically alternate between displaying the status of the temperature controller (auto/manual, run/stop, and alarms) and the pv or sv. ? preventive maintenance for relays in the temperature controller using a control output on/off counter. main i/o functions 48 48-mm e5cn 48 48-mm e5cn-u refer to safety precautions on page 66. event inputs  none  two sensor inputs  universal thermocouple/pt inputs (models with temperature inputs)  analog current/voltage inputs (models with analog inputs) indication accuracy  thermocouple input: 0.3% of pv  pt input: 0.2% of pv  analog input: 0.2% fs sampling period  250 ms control output 1  relay output  voltage output (for driving ssr)  current output  long-life relay output (hybrid) control output 2  none  voltage output (for driving ssr) auxiliary outputs  none  one  two 2-level display: pv and sv 4-digit display e5cn  auto/manual switching  temperature controller status display  simple program function  control output on/off count alarm  pv change rate alarm  models also available with rs-485 communications this data sheet is provided as a guideline for selecting products . be sure to refer to the following user manuals for applicati on precautions and other information required for operati on before attempting to use the product. e5cn/e5an/e5en digital temperature controllers user's manual basic type (cat. no. h156) e5cn/e5an/e5en digital temperature controllers co mmunications manual basic type (cat. no. h158)
e5cn/e5cn-u 4 e5cn e5cn-u (48 x 48 mm) e5an (96 x 96 mm) e5en (48 x 96 mm) e5cn-h (48 x 48 mm) e5an-h (96 x 96 mm) e5en-h (48 x 96 mm) safety precautions operation lineup note: models with one control output and one or two auxiliary outputs and models with two control outputs can be used for heating/coo ling control. model number structure model number legend controllers 1. control output 1 r: relay output q: voltage output (for driving ssr) c: current output y: long-life relay output (hybrid) ? 1 2. auxiliary outputs ? 2 blank: none 2: two outputs 3. option m: option unit can be mounted. 4. input type t: universal thermocouple/platinum resistance thermometer l: analog current/voltage input 5. power supply voltage blank: 100 to 240 vac d: 24 vac/vdc 6. case color blank: black w: silver 7. terminal cover -500: with terminal cover option units 1. applicable controller cn: e5cn or e5cn-h 2. function 1 blank: none q: control output 2 (voltage for driving ssr) p: power supply for sensor 3. function 2 blank: none h: heater burnout/ssr failure/heater overcurrent detection (ct1) hh: heater burnout/ssr failure/heater overcurrent detection (ct2) b: two event inputs 03: rs-485 communications h03: heater burnout/ssr failure/heater overcurrent detection (ct1) + rs-485 communications hb: heater burnout/ssr failure/heater overcurrent detection (ct1) + two event inputs hh03: heater burnout/ssr failure/heater overcurrent detection (ct2) + rs-485 communications 4. version n2: applicable only to models released after january 2008 note: not all combinations of function 1 and function 2 specifications are possible for option units (e53- @@@@ ). ? 1. always connect an ac load to a long-life relay output. the output will not turn off if a dc load is connected because a triac is used for switching the circuit. for detai ls, check the conditions in ratings . ? 2. auxiliary outputs are contact outputs that can be us ed to output alarms or results of logic operations. plug-in terminal block e5cn basic type analog input temperature input 2 control outputs 1 control output 2 control outputs 1 control output 0 or 2 auxiliary outputs 2 auxiliary outputs 0 or 2 auxiliary outputs 2 auxiliary outputs analog input temperature input 1 control output 1 control output 0, 1, or 2 auxiliary outputs 0, 1, or 2 auxiliary outputs 1 2345 6 7 e5cn- @@ m @@ - @ -500 1 23 4 e53-cn @@@
e5cn/e5cn-u 5 e5cn e5cn-u (48 x 48 mm) e5an (96 x 96 mm) e5en (48 x 96 mm) e5cn-h (48 x 48 mm) e5an-h (96 x 96 mm) e5en-h (48 x 96 mm) operation safety precautions ordering information controllers with terminal blocks option units one of the following option units can be mounted to provide the e5cn wi th additional functions. note: option units cannot be used for plug-in models. these option units are applicable only to models released after january 2008. size case color power supply voltage input type auxiliary outputs control output 1 model 1/16 din 48 48 78 (w h d) black 100 to 240 vac thermocouple or resistance thermometer none relay output e5cn-rmt-500 voltage output (for driving ssr) e5cn-qmt-500 current output E5CN-CMT-500 2 relay output e5cn-r2mt-500 voltage output (for driving ssr) e5cn-q2mt-500 current output e5cn-c2mt-500 long-life relay output (hybrid) e5cn-y2mt-500 24 vac/vdc thermocouple or resistance thermometer none relay output e5cn-rmtd-500 voltage output (for driving ssr) e5cn-qmtd-500 current output e5cn-cmtd-500 2 relay output e5cn-r2mtd-500 voltage output (for driving ssr) e5cn-q2mtd-500 current output e5cn-c2mtd-500 100 to 240 vac analog (current/voltage) none relay output e5cn-rml-500 voltage output (for driving ssr) e5cn-qml-500 current output e5cn-cml-500 2 relay output e5cn-r2ml-500 voltage output (for driving ssr) e5cn-q2ml-500 current output e5cn-c2ml-500 long-life relay output (hybrid) e5cn-y2ml-500 24 vac/vdc analog (current/voltage) 2 relay output e5cn-r2mld-500 voltage output (for driving ssr) e5cn-q2mld-500 current output e5cn-c2mld-500 silver 100 to 240 vac thermocouple or resistance thermometer none relay output e5cn-rmt-w-500 voltage output (for driving ssr) e5cn-qmt-w-500 current output e5cn-cmt-w-500 2 relay output e5cn-r2mt-w-500 voltage output (for driving ssr) e5cn-q2mt-w-500 current output e5cn-c2mt-w-500 long-life relay output (hybrid) e5cn-y2mt-w-500 24 vac/vdc 2 relay output e5cn-r2mtd-w-500 voltage output (for driving ssr) e5cn-q2mtd-w-500 current output e5cn-c2mtd-w-500 functions model communications rs-485 3-phase heater burnout/ssr failure/ heater overcurrent detection e53-cnhh03n2 heater burnout/ssr failure/heater overcurrent detection event inputs e53-cnhbn2 communications rs-485 control output 2 (voltage for driving ssr) e53-cnq03n2 event inputs external power supply for es1b e53-cnpbn2 heater burnout/ssr failure/heater overcurrent detection external power supply for es1b e53-cnphn2 communications rs-485 external power supply for es1b e53-cnp03n2 communications rs-485 heater burnout/ssr failure/heater overcurrent detection e53-cnh03n2 communications rs-485 e53-cn03n2 event inputs e53-cnbn2 heater burnout/ssr failure/heater overcurrent detection control output 2 (voltage for driving ssr) e53-cnqhn2 3-phase heater burnout/ssr failure/ heater overcurrent detection control output 2 (voltage for driving ssr) e53-cnqhhn2 event inputs control output 2 (voltage for driving ssr) e53-cnqbn2
e5cn/e5cn-u 6 e5cn e5cn-u (48 x 48 mm) e5an (96 x 96 mm) e5en (48 x 96 mm) e5cn-h (48 x 48 mm) e5an-h (96 x 96 mm) e5en-h (48 x 96 mm) safety precautions operation model number structure model number legend (plug-in-type controllers) 1. output type r: relay output q: voltage output (for driving ssr) c: current output 2. number of alarms blank: no alarm 1: one alarm 2: two alarms 3. input type t: universal thermocouple/platinum resistance thermometer l: analog input 4. plug-in type u: plug-in type ordering information plug-in-type controllers 1 234 e5cn- @@@ u size case color power supply voltage input type auxiliary outputs control output 1 model 1/16 din black 100 to 240 vac thermocouple or resistance thermometer none relay output e5cn-rtu voltage output (for driving ssr) e5cn-qtu current output e5cn-ctu 1 relay output e5cn-r1tu voltage output (for driving ssr) e5cn-q1tu current output e5cn-c1tu 2 relay output e5cn-r2tu voltage output (for driving ssr) e5cn-q2tu current output e5cn-c2tu analog (current/voltage) 1 relay output e5cn-r1lu voltage output (for driving ssr) e5cn-q1lu current output e5cn-c1lu 2 relay output e5cn-r2lu voltage output (for driving ssr) e5cn-q2lu current output e5cn-c2lu 24 vac/vdc thermocouple or resistance thermometer none relay output e5cn-rtdu voltage output (for driving ssr) e5cn-qtdu current output e5cn-ctdu 1 relay output e5cn-r1tdu voltage output (for driving ssr) e5cn-q1tdu current output e5cn-c1tdu 2 relay output e5cn-r2tdu voltage output (for driving ssr) e5cn-q2tdu current output e5cn-c2tdu
e5cn/e5cn-u 7 e5cn e5cn-u (48 x 48 mm) e5an (96 x 96 mm) e5en (48 x 96 mm) e5cn-h (48 x 48 mm) e5an-h (96 x 96 mm) e5en-h (48 x 96 mm) operation safety precautions accessories (order separately) usb-serial conversion cable terminal cover note: the terminal cover comes with the e5cn- @@@ -500 models. waterproof packing note: the waterproof packing is included with the controller only for models with terminal blocks. current transformers (cts) adapter note: use this adapter when the panel has been previously prepared for the e5b @ . sockets (for plug-in models) cx-thermo support software model e58-cifq1 connectable models terminal block models model e53-cov17 model y92s-29 hole diameter model 5.8 dia. e54-ct1 12.0 dia. e54-ct3 connectable models model terminal block models y92f-45 type model front-connecting socket p2cf-11 front-connecting socket wi th finger protection p2cf-11-e back-connecting socket p3ga-11 terminal cover for back-connecting socket with finger protection y92a-48g model est2-2c-mv4
e5cn/e5cn-u 8 e5cn e5cn-u (48 x 48 mm) e5an (96 x 96 mm) e5en (48 x 96 mm) e5cn-h (48 x 48 mm) e5an-h (96 x 96 mm) e5en-h (48 x 96 mm) safety precautions operation specifications ratings power supply voltage no d in model number: 100 to 240 vac, 50/60 hz d in model number: 24 vac, 50/60 hz; 24 vdc operating voltage range 85% to 110% of rated supply voltage power consump- tion e5cn 100 to 240 vac: 7.5 va (max.) (e5cn-r2t at 100 vac: 3.0 va) 24 vac/vdc: 5 va/3 w (max.) (e5cn-r2td at 24 vac: 2.7 va) e5cn-u 100 to 240 vac: 6 va (max.) 24 vac/vdc: 3 va/2 w (max.) (models with current output: 4 va/2 w) sensor input models with temperature inputs thermocouple: k, j, t, e, l, u, n, r, s, b, w, or pl ii platinum resistance thermometer: pt100 or jpt100 infrared temperature sensor: 10 to 70 c, 60 to 120 c, 115 to 165 c, or 140 to 260 c voltage input: 0 to 50 mv models with analog inputs current input: 4 to 20 ma or 0 to 20 ma voltage input: 1 to 5 v, 0 to 5 v, or 0 to 10 v input impedance current input: 150 ? max., voltage input: 1 m ? min. (use a 1:1 connection when connecting the es2-hb.) control method on/off control or 2-pid control (with auto-tuning) control outputs relay output e5cn spst-no, 250 vac, 3 a (resistive load), electr ical life: 100,000 operati ons, minimum applicable load: 5 v, 10 ma e5cn-u spdt, 250 vac, 3 a (resistive load), electrical life: 100,000 operations, mi nimum applicable load: 5 v, 10 ma voltage output (for driving ssr) e5cn e5cn-u output voltage: 12 vdc 15% (pnp), max. load current: 21 ma, with short-circuit protection circuit current output e5cn 4 to 20 ma dc/0 to 20 ma dc, load: 600 ? max., resolution: approx. 10,000 long-life relay output e5cn spst-no, 250 vac, 3 a (resistive load), electric al life: 1,000,000 operations, load power supply voltage: 75 to 250 vac (dc loads cannot be connec ted.), minimum applicable load: 5 v, 10 ma, leakage current: 5 ma max. (250 vac, 60 hz) auxiliary outputs number of outputs 1 or 2 max. (depends on the model.) output specifica- tions relay output: spst-no, 250 vac, 3 a (resistive load ), electrical life: 100 ,000 operations, minimum applicable load: 5 v, 10 ma event inputs number of inputs 2 external contact input specifica- tions contact input: on: 1 k ? max., off: 100 k ? min. non-contact input: on: residual voltage: 1.5 v max., off: leakage current: 0.1 ma max. current flow: approx. 7 ma per contact external power supply for es1b 12 vdc 10%, 20 ma, short-circuit pr otection circuit provided setting method digital setting using front panel keys indication method 11-segment digital display and individual indicators (7-segm ent display also possible) character height: pv: 11 mm, sv: 6.5 mm multi sp up to four set points (sp0 to sp3) can be saved and selected using event inputs, key operations, or serial communications. bank switching not supported other functions manual output, heating/cooling control, loop burnout alarm, sp ramp, other alarm functions, heater burnout detection, 40% at, 100% at, mv limiter, input digita l filter, self-tuning, temperature input shift, run/stop, protection functions, control output on/off counter, extraction of square root, mv change rate limit, logic operations, pv/sv status display, simple pr ogram, automatic cooli ng coefficient adjustment ambient operating temperature ? 10 to 55 c (with no condensation or icin g), for 3-year warranty: ? 10 to 50 c ambient operating humidity 25% to 85% storage temperature ? 25 to 65 c (with no condensation or icing)
e5cn/e5cn-u 9 e5cn e5cn-u (48 x 48 mm) e5an (96 x 96 mm) e5en (48 x 96 mm) e5cn-h (48 x 48 mm) e5an-h (96 x 96 mm) e5en-h (48 x 96 mm) operation safety precautions input ranges thermocouple/platinum resistance thermometer (uni versal inputs) models with analog inputs shaded settings are the default settings. input type platinum resistance thermometer thermocouple infrared temperature sensor analog input name pt100 jpt100 k j t e l u n r s b w pl ii 10 to 70 c 60 to 120 c 115 to 165 c 140 to 260 c 0 to 50 mv temperature range ( c) 2300 1800 1700 1600 1500 1400 1300 1200 1100 1000 900 800 700 600 500 400 300 200 100 0 ? 100.0 ? 200.0 2300 usable in the following ranges by scaling: ? 1999 to 9999 or ? 199.9 to 999.9 1800 1700 1700 1300 1300 1300 850 850 850 600 500.0 500.0 500.0 400.0 400 400.0 400 400.0 260 120 165 100.0 100.0 90 100 0.0 0.0 00 00 0 0 0 0 ? 20.0 ? 100 ? 20.0 ? 100 ? 200 ? 199.9 ? 199.9 ? 200 ? 200 ? 199.9 ? 200 ? 200 ? 199.9 ? 200 setting number 01234 5 6 7 8 9 1011121314151617182425 19 20 21 22 23 shaded settings are the default settings. the applicable standards for the input types are as follows: k, j, t, e, n, r, s, b: jis c 1602-1995, iec 584-1 l: fe-cuni, din 43710-1985 u: cu-cuni, din 43710-1985 w: w5re/w26re, astm e988-1990 jpt100: jis c 1604-1989, jis c 1606-1989 pt100: jis c 1604-1997, iec 751 pl ii: according to platinel ii electromot ive force charts from basf (previously engelhard) input type current voltage input specification 4 to 20ma 0 to 20 ma 1 to 5 v 0 to 5 v 0 to 10 v setting range usable in the following ranges by scaling: ? 1999 to 9999, ? 199.9 to 999.9, ? 19.99 to 99.99 or ? 1.999 to 9.999 setting number 01234
e5cn/e5cn-u 10 e5cn e5cn-u (48 x 48 mm) e5an (96 x 96 mm) e5en (48 x 96 mm) e5cn-h (48 x 48 mm) e5an-h (96 x 96 mm) e5en-h (48 x 96 mm) safety precautions operation alarm outputs each alarm can be independently set to one of the following 13 alarm types. the default is 2: upper limit . auxiliary outputs are allocated for alarms. on delays and off delay s (0 to 999 s) can also be specified. note: for models with heater burnout, ssr failure, and heater overcurrent detection , alarm 1 will be an or output of the alarm select ed from the following alarm types and the alarms for heater burnout, ssr failure, and heater over current. to output only a heater burnout a larm, ssr failure alarm, and heater overcurrent alarm for alarm 1, set the alarm type to 0 (i.e., no alarm function). ? 1. with set values 1, 4 and 5, t he upper and lower limit values can be set independently for each alar m type, and are expressed as ?l? and ?h.? ? 2. set value: 1, upper- and lower-limit alarm ? 3. set value: 4, upper- and lower-limit range ? 4. set value: 5, upper- and lower-limit with standby sequence for upper- and lower-limit alarm described above  case 1 and 2 always off when the upper-limit and lower-limit hysteresis overlaps.  case 3: always off ? 5. set value: 5, upper- and lower-limit with standby sequence always off when the upper-limit and lower-limit hysteresis overlaps. set value alarm type alarm output operation when x is positive when x is negative 0 alarm function off output off 1 ? 1 upper- and lower- limit ? 2 2 upper limit 3lower limit 4 ? 1 upper- and lower- limit range ? 3 5 ? 1 upper- and lower- limit with standby sequence ? 4 6 upper-limit with standby sequence 7 lower-limit with standby sequence 8 absolute-value upper-limit 9 absolute-value lower-limit 10 absolute-value upper-limit with standby sequence 11 absolute-value lower-limit with standby sequence 12 lba (for alarm 1 only) --- 13 pv change rate alarm --- on off sp lh sp x on off sp x on off sp x on off sp x on off sp lh on off sp lh on off ? 5 sp x on off sp x on off sp x on off sp x on off 0 x on off 0 x on off 0 x on off 0 x on off 0 x on off 0 x on off 0 x on off 0 x on off lh h < 0, l > 0 ? h ? < ? l ? sp case 1 lh h > 0, l < 0 ? h ? > ? l ? sp case 2 l h h < 0, l < 0 sp l h h < 0, l > 0 ? h ? ? l ? sp l h h > 0, l < 0 ? h ? ? l ? sp case 3 (always on) lhsp case 1 lh sp case 2 l hsp l l hsp h sp case 3 (always off) h < 0, l > 0 ? h ? < ? l ? h > 0, l < 0 ? h ? > ? l ? h < 0, l < 0 h < 0, l > 0 ? h ? ? l ? h > 0, l < 0 ? h ? ? l ?
e5cn/e5cn-u 11 e5cn e5cn-u (48 x 48 mm) e5an (96 x 96 mm) e5en (48 x 96 mm) e5cn-h (48 x 48 mm) e5an-h (96 x 96 mm) e5en-h (48 x 96 mm) operation safety precautions characteristics ? 1. the indication accuracy of k thermocouples in the ? 200 to 1300 c range, t and n thermocouples at a temperature of ? 100 c max., and u and l thermocouples at any temperatures is 2 c 1 digit max. the indication accuracy of the b thermocouple at a temperature of 400 c max. is not specified. the indication accuracy of b thermocouples in the 400 to 800 c range is 3 c max. the indication accuracy of the r and s thermocouples at a temperature of 200 c max. is 3 c 1 digit max. the indication accuracy of w thermocouples is 0.3 of pv or 3 c, whichever is greater, 1 digit max. the indication accuracy of pl ii thermocouples is 0.3 of pv or 2 c, whichever is greater, 1 digit max. ? 2. ambient temperature: ? 10 c to 23 c to 55 c, voltage range: ? 15% to 10% of rated voltage ? 3. k thermocouple at ? 100 c max.: 10 max. ? 4. ?eu? stands for engineering unit and is used as the unit after scaling. for a temperature sensor, the eu is c or f. ? 5. when robust tuning (rt) is on, the differential time is 0.0 to 999.9 (in units of 0.1 s). ? 6. external communications (rs-485) and cable communications for the setup tool can be used at the same time. ? 7. the e5cn-u plug-in model is certified for ul listing only when used together with the omron p2cf-11 or p2cf-11-e socket. the p3ga-11 is not certified for ul listing. indication accuracy thermocouple: ? 1 terminal block models (e5cn): ( 0.3% of indicated value or 1 c, whichever is greater) 1 digit max. plug-in models (e5cn-u): ( 1% of indicated value or 2 c, whichever is greater) 1 digit max. platinum resistance thermometer input: terminal block models (e5cn) and plug-in models (e5cn-u): ( 0.2% of indicated value or 0.8 c, whichever is greater) 1 digit max. analog input: terminal block models (e5cn) and plug-in models (e5cn-u): 0.2% fs 1 digit max. ct input: terminal block models (e5cn): 5% fs 1 digit max. influence of temperature ? 2 thermocouple input (r, s, b, w, pl ii): terminal block models (e5cn): ( 1% of pv or 10 c, whichever is greater) 1 digit max. plug-in models (e5cn-u): ( 2% of pv or 10 c, whichever is greater) 1 digit max. other thermocouple input: ? 3 terminal block models (e5cn): ( 1% of pv or 4 c, whichever is greater) 1 digit max. plug-in models (e5cn-u): ( 2% of pv or 4 c, whichever is greater) 1 digit max. platinum resistance thermometer input: terminal block models (e5cn) and plug-in models (e5cn-u): ( 1% of pv or 2 c, whichever is greater) 1 digit max. analog input: terminal block models (e5cn) and plug-in models (e5cn-u): ( 1%fs) 1 digit max. influence of voltage ? 2 input sampling period 250 ms hysteresis models with thermocouple/platinum resistance thermometer input (universal input): 0.1 to 999.9 eu (in units of 0.1 eu) ? 4 models with analog input: 0.01 to 99.99% fs (in units of 0.01% fs) proportional band (p) models with thermocouple/platinum resistance thermometer input (universal input): 0.1 to 999.9 eu (in units of 0.1 eu) ? 4 models with analog input: 0.1 to 999.9% fs (in units of 0.1% fs) integral time (i) 0 to 3999 s (in units of 1 s) derivative time (d) 0 to 3999 s (in units of 1 s) ? 5 control period 0.5, 1 to 99 s (in units of 1 s) manual reset value 0.0 to 100.0% (in units of 0.1%) alarm setting range ? 1999 to 9999 (decimal point position depends on input type) affect of signal source resis- tance thermocouple: 0.1 c/ ? max. (100 ? max.) platinum resistance thermometer: 0.1 c/ ? max. (10 ? max.) insulation resistance 20 m ? min. (at 500 vdc) dielectric strength 2,300 vac, 50 or 60 hz for 1 min (between terminals with different charge) vibration resistance malfunction 10 to 55 hz, 20 m/s 2 for 10 min each in x, y, and z directions destruction 10 to 55 hz, 0.75-mm single amplitude for 2 hrs each in x, y, and z directions shock resistance malfunction 100 m/s 2 , 3 times each in x, y, and z directions destruction 300 m/s 2 , 3 times each in x, y, and z directions weight e5cn controller: approx. 150 g, mounting bracket: approx. 10 g e5cn-u controller: approx. 110 g, mounting bracket: approx. 10 g degree of protection e5cn front panel: ip66, rear case: ip20, terminals: ip00 e5cn-u front panel: ip50, rear case: ip20, terminals: ip00 memory protection non-volatile memory (number of writes: 1,000,000 times) setup tool cx-thermo version 4.0 or higher setup tool port provided on the bottom of the e5cn. use this port to connect a computer to the e5cn when using the setup tool. an e58-cifq1 usb-serial conversion cable is required to connect the computer to the e5cn. ? 6 standards approved standards ? 7 ul 61010-1, csa c22.2 no. 1010-1 conformed standards en 61010-1 (iec 61010-1): pollution level 2, overcurrent category ii emc emi: en 61326 radiated interference electromagnetic field strength: en 55011 group 1, class a noise terminal voltage: en 55011 group 1, class a ems: en 61326 esd immunity: en 61000-4-2 electromagnetic field immunity: en 61000-4-3 burst noise immunity: en 61000-4-4 conducted disturbance immunity: en 61000-4-6 surge immunity: en 61000-4-5 power frequency magnetic field immunity: en 61000-4-8 voltage dip/interrupting immunity: en 61000-4-11
e5cn/e5cn-u 12 e5cn e5cn-u (48 x 48 mm) e5an (96 x 96 mm) e5en (48 x 96 mm) e5cn-h (48 x 48 mm) e5an-h (96 x 96 mm) e5en-h (48 x 96 mm) safety precautions operation usb-serial conversion cable note: a driver must be installed in the personal computer. refer to installation information in the operation manual for the conversion cable. communications specifications ? the baud rate, data bit length, stop bit length, and vertical parity can be individually set using the communications setting level. current transformer (order separately) ratings heater burnout alarms, ssr failure alarms, and heater overcurrent alarms ? 1. for heater burnout alarms, the heat er current will be measured when the control output is on, and the output assigned to the alarm 1 function will turn on if the heater current is lower than the set value (i.e., heater burnout detection current value). ? 2. for ssr failure alarms, the heater current will be measured when the control output is off, and the output assigned to the alarm 1 function will turn on if the heater current is higher than the set value (i.e., ssr failure detection current value). ? 3. for heater overcurrent alarms , the heater current will be measured when the control output is on, and the output assigned to the alarm 1 function will turn on if the heater current is higher than the set value (i.e., heater overcurrent detection current value). electrical life expectancy curve for relays (reference values) note: do not connect a dc load to a controller with a long-life relay output. applicable os windows 2000, xp, or vista applicable software thermo mini, cx-thermo version 4.0 or higher applicable models e5an/e5en/e5cn/e5cn-u/e5an-h/ e5en-h/e5cn-h usb interface standard conforms to usb specification 1.1. dte speed 38400 bps connector specifications computer: usb (type a plug) temperature controller: setup tool port (on bottom of controller) power supply bus power (supplied from usb host controller.) power supply voltage 5 vdc current consumption 70 ma ambient operating temperature 0 to 55c (with no condensation or icing) ambient operating humidity 10% to 80% storage temperature ? 20 to 60c (with no condensation or icing) storage humidity 10% to 80% altitude 2,000 m max. weight approx. 100 g transmission line connection method rs-485: multipoint communications rs-485 (two-wire, half duplex) synchronization method start-stop synchronization protocol compoway/f, sysway, or modbus baud rate 1200, 2400, 4800, 9600, 19200, 38400, or 57600 bps transmission code ascii data bit length ? 7 or 8 bits stop bit length ? 1 or 2 bits error detection vertical parity (none, even, odd) frame check sequence (fcs) with sysway block check character (bcc) with compoway/f or crc-16 modbus flow control none interface rs-485 retry function none communications buffer 217 bytes communications response wait time 0 to 99 ms default: 20 ms dielectric strength 1,000 vac for 1 min vibration resistance 50 hz, 98 m/s 2 weight e54-ct1: approx. 11.5 g, e54-ct3: approx. 50 g accessories (e54-ct3 only) armatures (2) plugs (2) ct input (for heater current de- tection) models with detection for single-phase heaters: one input models with detection for single-phase or three-phase heaters: two inputs maximum heater current 50 a ac input current indication accuracy 5% fs 1 digit max. heater burnout alarm setting range ? 1 0.1 to 49.9 a (in units of 0.1 a) minimum detection on time: 100 ms ssr failure alarm set- ting range ? 2 0.1 to 49.9 a (in units of 0.1 a) minimum detection off time: 100 ms heater overcurrent alarm setting range ? 3 0.1 to 49.9 a (in units of 0.1 a) minimum detection on time: 100 ms 500 300 100 50 30 10 5 3 1 01 2 3 4 56 e5cn 250 vac, 30 vdc (resistive load) cos = 1 switching current (a) life ( 10 4 operations)
e5cn/e5cn-u 13 e5cn e5cn-u (48 x 48 mm) e5an (96 x 96 mm) e5en (48 x 96 mm) e5cn-h (48 x 48 mm) e5an-h (96 x 96 mm) e5en-h (48 x 96 mm) operation safety precautions external connections ? a voltage output (control output, for driving ssr) is not electrical ly insulated from the intern al circuits. when using a groun ding thermocouple, do not connect any of the control output term inals to ground. (if the control output te rminals are connected to ground, errors will occur in the measured temperature values as a result of leakage current.) ? consult with your omron r epresentative before using the external power supply for th e es1b for any other purpose. e5cn controllers option units e5cn-u note: for the wiring socket, purchase t he p2cf-11 or pg3a-11 separately. voltage output (for driving ssr) 12 vdc, 21 ma control output 2 relay output 250 vac, 3 a (resistive load) voltage output (for driving ssr) 12 vdc, 21 ma current output 0 to 20 ma dc load: 600 ? max. 4 to 20 ma dc long-life relay output 250 vac, 3 a (resistive load) control output 1 auxiliary outputs (relay outputs) + ? a b b tc/pt universalinput + ? input power supply control output 1 auxiliary outputs (relay outputs) 250 vac, 3 a (resistive load)  100 to 240 vac  24 vac/vdc (no polarity) + analog input ? + v ? auxiliary output 2 ma auxiliary output 1 a heater burnout alarm, heater short alarm, heater overcurrent alarm, or input alarm is sent to the output to which the alarm 1 function is assigned. do not use do not use do not use 11 12 13 14 15 ev1 ev2 e53-cnhbn2 event inputs and ct 11 12 13 14 15 e53-cnpbn2 event inputs and external power supply ev1 ev2 + ? external power supply 12 vdc, 20 ma 11 12 13 14 15 e53-cnphn2 external power supply and ct + ? external power supply 12 vdc, 20 ma 11 12 13 14 15 b(+) a( ? ) rs-485 e53-cnp03n2 communications (rs-485) and external power supply + ? external power supply 12 vdc, 20 ma 11 12 13 14 15 e53-cnqhn2 control output 2 and ct + ? control output 2 11 12 13 14 15 ev1 ev2 e53-cnqbn2 event inputs and control output 2 + ? control output 2 11 12 13 14 15 b(+) a( ? ) rs-485 e53-cnhh03n2 communications (rs-485) and ct2 11 12 13 14 15 b(+) a( ? ) rs-485 e53-cnq03n2 communications (rs-485) and control output 2 + ? control output 2 11 12 13 14 15 b(+) a( ? ) rs-485 e53-cn03n2 communications (rs-485) 11 12 13 14 15 ev1 ev2 e53-cnbn2 event inputs 11 12 13 14 15 e53-cnqhhn2 control output 2 and ct2 + ? control output 2 11 12 13 14 15 b(+) a( ? ) rs-485 e53-cnh03n2 communications (rs-485) and ct do not use do not use do not use do not use do not use do not use do not use do not use do not use do not use ct1 ct1 ct1 ct1 ct1 ct1 ct2 ct2 a b b auxiliary output 250 vac, 3 a (resistive load) control output 1 tc/pt universal in p ut input power supply  100 to 240 vac  24 vac/vdc ( no p olarit y) auxiliary output 1 (relay outputs) analog input v ma an input error is sent to the output to which the alarm 1 function is assigned. current output 0 to 20 ma dc relay output (three terminals used) spdt, 250 vac, 3 a (resistive load) voltage output (for driving ssr) 12 vdc, 21 ma load: 600 w max. 4 to 20 ma dc control output 1 auxiliary output 2 (control output (cooling side)) do not use do not use do not use
e5cn/e5cn-u 14 e5cn e5cn-u (48 x 48 mm) e5an (96 x 96 mm) e5en (48 x 96 mm) e5cn-h (48 x 48 mm) e5an-h (96 x 96 mm) e5en-h (48 x 96 mm) safety precautions operation nomenclature dimensions (unit: mm) accessories (order separately) usb-serial conversion cable operation indicators level key temperature unit no.1 display no. 2 display up key mode key down key e5 c n e5cn-u the front panel is the same for the e5cn and e5cn-u. 45 +0.6 0 45 +0.6 0 45 +0.6 0 60 min. (48 number of units ? 2.5) +1.0 0 group mounting does not allow waterproofing. panel cutout mounted separately group mounted 48 48 terminal cover (e53-cov17) (accessory) 44.8 44.8 48.8 6 1.5 91 78 mounting adapter (accessory) 58 waterproof packing (accessory) e5cn terminal models note: the terminal block cannot be removed.  recommended panel thickness is 1 to 5 mm.  group mounting is not possible in the vertical direction. (maintain the specified mounting space between controllers.)  to mount the controlle r so that it is waterproof, insert the waterproof packing onto the controller.  when two or more controllers are mounted, make sure that the surrounding temperature does not exceed the allowable operating temperature specified in the specifications. 48 48 6 14.2 58 44.8 44.8 70.5 (84.7) mounting adapter (accessory) 45 +0.6 0 45 +0.6 0 45 +0.6 0 60 min. (48 number of units ? 2.5) +1.0 0 panel cutout mounted separately group mounted e5cn-u plug-in models  recommended panel thickness is 1 to 5 mm.  group mounting is not possible in the vertical direction. (maintain the specified mounting space between controllers.)  when two or more controllers are mounted, make sure that the surrounding temperature does not exceed the allowable operating temperature specified in the specifications. (2,100) 250 1,765 usb connector (type a plug) serial connector led indicator ( rd ) led indicator (sd) e58-cifq1
e5cn/e5cn-u 15 e5cn e5cn-u (48 x 48 mm) e5an (96 x 96 mm) e5en (48 x 96 mm) e5cn-h (48 x 48 mm) e5an-h (96 x 96 mm) e5en-h (48 x 96 mm) operation safety precautions current transformers 48 48.8 22 9.1 order the waterproof packing separately if it becomes lost or damaged. the waterproof packing can be used to achieve an ip66 degree of protection. (deterioration, shrinking, or har dening of the waterproof packing may occur depending on the operating env ironment. therefore, periodic replacement is recommended to ensure the level of waterproofing specified in ip66. the time fo r periodic replacement depends on the operating environment. be sure to c onfirm this point at your site. consider one year a rough standard. omron shall not be liable for the level of water resistance if th e customer does not perform periodic replacement.) the waterproof packing does not need to be attached if a waterproof structure is not required. terminal cover e53-cov17 waterproof packing y92s-29 (for din 48 48) note: the e53-cov10 cannot be used. e54-ct3 accessory ? armature 30 21 15 5.8 dia. 25 3 40 10.5 2.8 7.5 10 two, 3.5 dia. 40 40 30 12 dia. 9 2.36 dia. 15 30 two, m3 (depth: 4) approx. 3 dia. 18 (22) approx. 6 dia. plug armature lead e54-ct1 e54-ct3 connection example ? plug e54-ct1 thru-current (io) vs. output voltage (eo) (reference values) maximum continuous heater current: 50 a (50/60 hz) number of windings: 4002 winding resistance: 182 ? thru-current (io) a (r.m.s.) 1 10 100 ma 1 10 100 1,000 a output voltage (eo) v (r.m.s.) 100 v 50 hz distortion factor 10% 3% 1% 100 ? rl = 10 ? 10 1 100 mv 10 1 100 v 10 1 k ? e54-ct3 thru-current (io) vs. output voltage (eo) (reference values) maximum continuous heater current: 120 a (50/60 hz) (maximum continuous heater current for the temperature controller is 50 a.) number of windings: 4002 winding resistance: 80.8 ? 3% 1% 1 k ? 100 ? 50 ? r l = 10 ? 500 ? distor- tion factor 10% thru-current (io) a (r.m.s.) 1 10 100 ma 1 10 100 1,000 a output voltage (eo) v (r.m.s.) 100 v 50 hz 10 1 100 mv 10 1 100 v 10
e5cn/e5cn-u 16 e5cn e5cn-u (48 x 48 mm) e5an (96 x 96 mm) e5en (48 x 96 mm) e5cn-h (48 x 48 mm) e5an-h (96 x 96 mm) e5en-h (48 x 96 mm) safety precautions operation adapter e5cn-u wiring socket note: a model with finger protection (p 2cf-11-e) is also available. note: 1. using any other sockets will adversely affect accuracy. use only t he specified sockets. 2. a protective cover for finger protec tion (y92a-48g) is also available. fixture (accessory) 69.6 to 77.6 87 67 67 72 72 76 4.7 72 72 48 48 panel (1 to 8 mm) 77.3 (to back of e5cn) 2.2 4.7 y92f-45 note: use this adapter when the panel has already been prepared for the e5b @ . mounted to e5cn 40 0.2 4.5 5 6 7 8 4 3 2 1 9 10 11 70 max. 4 eleven, m3.5 7.5 sems screws 7.8 tw o, 4.5-dia. holes 50 max. 3 31.2 max. 35.4 note: can also be mounted to a din track. mounting holes terminal layout/internal connections (top view) two, 4.5 dia. mounting holes front-connecting socket p2cf-11 5 6 7 8 4 3 2 9 10 11 1 25.6 27 dia. 45 45 4.5 16.3 6.2 47 3 8.7 6 terminal layout/internal connections (bottom view) back-connecting socket p3ga-11
17 e5cn e5cn-u (48 x 48 mm) e5cn-h (48 x 48 mm) e5an-h (96 x 96 mm) e5en-h (48 x 96 mm) operation safety precautions e5an (96 x 96 mm) e5en (48 x 96 mm) basic-type digital temperature controller e5an/e5en (96 x 96 mm and 48 x 96 mm) new 96 x 96-mm and 48 x 96-mm basic temperature controllers with enhanced functions and performance. improved indication accuracy and preventive maintenance function. ? indication accuracy thermocouple input: 0.3% of pv (previous models: 0.5%) pt input: 0.2% of pv (previous models: 0.5%) analog input: 0.2% fs (previous models: 0.5%) ? a pv/sv-status display function can be set to automatically alternate between displaying the status of the temperature controller (auto/manual, run/stop, and alarms) and the pv or sv. ? preventive maintenance for relays in the temperature controller using a control output on/off counter. ? three-level display that simultaneously displays the pv, sv, and mv. ? one-touch operation with pf key that can be assigned to auto/manual, run/ stop, or other functions. main i/o functions 96 96 mm e5an 48 96 mm e5en refer to safety precautions on page 66. sensor inputs  universal thermocouple/pt inputs (models with temperature inputs)  analog current/voltage inputs (models with analog inputs) indication accuracy  thermocouple input: 0.3% of pv  pt input: 0.2% of pv  analog input: 0.2% fs sampling period ? 250 ms pf key (programmable function key) control output 1 ? relay output ? voltage output (for driving ssr) ? current output control output 2 ? voltage output (for driving ssr) ? long-life relay output (hybrid) auxiliary outputs ? three ? auto/manual switching ? temperature controller status display ? simple program function ? control output on/off count alarm ? pv change rate alarm ? models also available with rs-485 or rs-232c communications e5an e5en 4-digit display 3-level display ? simultaneously displays set items, such as the pv, sv, and mv. ? a 2-level display when shipped from the factory. a 3-level display is activated if parameters are initialized. for details on the third display level, refer to the user?s manual, basic type (cat. no. h156) . event inputs ? none ? two this data sheet is provided as a guideline for selecting products . be sure to refer to the following user manuals for applicati on precautions and other information required for operati on before attempting to use the product. e5cn/e5an/e5en digital temperature controllers user's manual basic type (cat. no. h156) e5cn/e5an/e5en digital temperature controllers co mmunications manual basic type (cat. no. h158)
e5an/e5en 18 e5cn e5cn-u (48 x 48 mm) e5cn-h (48 x 48 mm) e5an-h (96 x 96 mm) e5en-h (48 x 96 mm) safety precautions operation e5an (96 x 96 mm) e5en (48 x 96 mm) lineup note: models with one control output or two contro l outputs can be used for heating/cooling control. model number structure model number legend controllers 1. control output 1 r: relay output q: voltage output (for driving ssr) c: current output 2. auxiliary outputs 3: three outputs 3. heater burnout/ssr failure, control output 2, or external power supply for es1b blank: none q: control output 2 (voltage output for driving ssr) y: long-life relay output (hybrid) h: heater burnout/ssr failure/heater overcurrent detection (ct1) hh: heater burnout/ssr failure/heater overcurrent detection (ct2) p: power supply for sensor 4. option m: option unit can be mounted. 5. input type t: universal thermocouple/platinum resistance thermometer input l: analog current/voltage input 6. power supply voltage blank: 100 to 240 vac d: 24 vac/vdc 7. case color blank: black w: silver 8. terminal cover -500: with terminal cover 9. version n: available only to models released after january 2008. option units 1. function en01: rs-232c communications en03: rs-485 communications akb: event input terminal block e5an/e5en basic type analog input temperature input 2 control outputs 1 control output 2 control outputs 1 control output 3 auxiliary outputs 3 auxiliary outputs 3 auxiliary outputs 3 auxiliary outputs 1 23 4 5 6 7 8 9 e5an/e5en- @ 3 @ m @@ - @ -500-n 1 e53- @
e5an/e5en 19 e5cn e5cn-u (48 x 48 mm) e5cn-h (48 x 48 mm) e5an-h (96 x 96 mm) e5en-h (48 x 96 mm) operation safety precautions e5an (96 x 96 mm) e5en (48 x 96 mm) ordering information e5an controllers with terminal blocks size case color power supply voltage input type auxilia- ry outputs control output 1 functions model heater burnout power supply for sensor control output 2 1/4 din 96 96 78 (w h d) black 100 to 240 vac thermocouple or resistance thermometer 3 relay output e5an-r3mt-500-n voltage output (for driving ssr) e5an-q3mt-500-n current output e5an-c3mt-500-n relay output 1 e5an-r3hmt-500-n voltage output for driving ssr) 1 e5an-q3hmt-500-n relay output 2 e5an-r3hhmt-500-n voltage output for driving ssr) 2 e5an-q3hhmt-500-n relay output voltage output e5an-r3qmt-500-n voltage output (for driving ssr) voltage output e5an-q3qmt-500-n current output voltage output e5an-c3qmt-500-n relay output long-life relay output e5an-r3ymt-500-n voltage output (for driving ssr) e5an-q3ymt-500-n current output e5an-c3ymt-500-n relay output sensor power e5an-r3pmt-500-n voltage output (for driving ssr) sensor power e5an-q3pmt-500-n analog (current/voltage) 3 relay output e5an-r3ml-500-n voltage output (for driving ssr) e5an-q3ml-500-n current output e5an-c3ml-500-n relay output 1 e5an-r3hml-500-n voltage output (for driving ssr) 1 e5an-q3hml-500-n voltage output (for driving ssr) long-life relay output e5an-q3yml-500-n 24 vac/ vdc thermocouple or resistance thermometer 3 relay output e5an-r3mtd-500-n voltage output (for driving ssr) e5an-q3mtd-500-n current output e5an-c3mtd-500-n relay output 1 e5an-r3hmtd-500-n voltage output (for driving ssr) 1 e5an-q3hmtd-500-n relay output 2 e5an-r3hhmtd-500-n voltage output (for driving ssr) 2 e5an-q3hhmtd-500-n silver 100 to 240 vac thermocouple or resistance thermometer 3 relay output e5an-r3mt-w-500-n voltage output (for driving ssr) e5an-q3mt-w-500-n current output e5an-c3mt-w-500-n relay output 1 e5an-r3hmt-w-500-n voltage output (for driving ssr) 1 e5an-q3hmt-w-500-n 24 vac/ vdc relay output e5an-r3mtd-w-500-n voltage output (for driving ssr) e5an-q3mtd-w-500-n current output e5an-c3mtd-w-500-n
e5an/e5en 20 e5cn e5cn-u (48 x 48 mm) e5cn-h (48 x 48 mm) e5an-h (96 x 96 mm) e5en-h (48 x 96 mm) safety precautions operation e5an (96 x 96 mm) e5en (48 x 96 mm) e5en controllers with terminal blocks size case color power supply voltage input type auxilia- ry outputs control output 1 functions model heater burnout power supply for sensor control output 2 1/8 din 48 96 78 (w h d) black 100 to 240 vac thermocouple or resistance thermometer 3 relay output e5en-r3mt-500-n voltage output (for driving ssr) e5en-q3mt-500-n current output e5en-c3mt-500-n relay output 1 e5en-r3hmt-500-n voltage output (for driving ssr) 1 e5en-q3hmt-500-n relay output 2 e5en-r3hhmt-500-n voltage output (for driving ssr) 2 e5en-q3hhmt-500-n relay output voltage output e5en-r3qmt-500-n voltage output (for driving ssr) voltage output e5en-q3qmt-500-n current output voltage output e5en-c3qmt-500-n relay output long-life relay output e5en-r3ymt-500-n voltage output (for driving ssr) long-life relay output e5en-q3ymt-500-n current output long-life relay output e5en-c3ymt-500-n relay output sensor po wer e5en-r3pmt-500-n voltage output (for driving ssr) sensor power e5en-q3pmt-500-n analog (current/volt- age) 3 relay output e5en-r3ml-500-n voltage output (for driving ssr) e5en-q3ml-500-n current output e5en-c3ml-500-n relay output 1 e5en-r3hml-500-n voltage output (for driving ssr) 1 e5en-q3hml-500-n long-life relay output e5en-q3yml-500-n 24 vac/ vdc thermocouple or resistance thermometer 3 relay output e5en-r3mtd-500-n voltage output (for driving ssr) e5en-q3mtd-500-n current output e5en-c3mtd-500-n relay output 1 e5en-r3hmtd-500-n voltage output (for driving ssr) 1 e5en-q3hmtd-500-n relay output 2 e5en-r3hhmtd-500-n voltage output (for driving ssr) 2 e5en-q3hhmtd-500-n silver 100 to 240 vac thrmocouple or resistance thermometer 3 relay output e5en-r3mt-w-500-n voltage output (for driving ssr) e5en-q3mt-w-500-n current output e5en-c3mt-w-500-n relay output 1 e5en-r3hmt-w-500-n 24 vac/ vdc voltage output (for driving ssr) 1 e5en-q3hmt-w-500-n relay output e5en-r3mtd-w-500-n voltage output (for driving ssr) e5en-q3mtd-w-500-n current output e5en-c3mtd-w-500-n
e5an/e5en 21 e5cn e5cn-u (48 x 48 mm) e5cn-h (48 x 48 mm) e5an-h (96 x 96 mm) e5en-h (48 x 96 mm) operation safety precautions e5an (96 x 96 mm) e5en (48 x 96 mm) option units accessories (order separately) usb-serial conversion cable terminal cover note: the terminal cover comes with the e5cn- @@@ -500 models. waterproof packing note: the waterproof packing is in cluded with the controller. current transformers (cts) cx-thermo support software name function model communications unit rs-232c communications e53-en01 rs-485 communications e53-en03 event input unit event inputs e53-akb model e58-cifq1 connectable models model e5an e53-cov16 e5en connectable models model e5an y92s-p4 e5en y92s-p5 hole diameter model 5.8 dia. e54-ct1 12.0 dia. e54-ct3 model est2-2c-mv4
e5an/e5en 22 e5cn e5cn-u (48 x 48 mm) e5cn-h (48 x 48 mm) e5an-h (96 x 96 mm) e5en-h (48 x 96 mm) safety precautions operation e5an (96 x 96 mm) e5en (48 x 96 mm) specifications ratings ? a 2-level display when shipped from the factory. a 3-level displa y is activated if parameters ar e initialized. for details on t he third display level, refer to the user?s manual, basic type (cat. no. h156). power supply voltage no d in model number: 100 to 240 vac, 50/60 hz d in model number: 24 vac, 50/60 hz; 24 vdc operating voltage range 85% to 110% of rated supply voltage power consumption 100 to 240 vac: 10 va 24 vac/vdc: 5.5 va (24 vac)/4 w (24 vdc) sensor input models with temperature inputs thermocouple: k, j, t, e, l, u, n, r, s, b, w, or pl ii platinum resistance thermometer: pt100 or jpt100 infrared temperature sensor: 10 to 70 c, 60 to 120 c, 115 to 165 c, or 140 to 260 c voltage input: 0 to 50 mv models with analog inputs current input: 4 to 20 ma or 0 to 20 ma voltage input: 1 to 5 v, 0 to 5 v, or 0 to 10 v input impedance current input: 150 ? max., voltage input: 1 m ? min. (use a 1:1 connection when connecting the es2-hb.) control method on/off control or 2-pid control (with auto-tuning) control output relay output spst-no, 250 vac, 5 a (resistive load) , electrical life: 100,000 operations , minimum applicable load: 5 v, 10 ma voltage output (for driving ssr) output voltage: 12 vdc 15% (pnp), max. load current: 40 ma, with short-circuit prot ection circuit: max. load current of 21 ma for control output 2 current output 4 to 20 ma dc/0 to 20 ma dc, load: 600 ? max., resolution: approx. 10,000 long-life relay out- put spst-no, 250 vac, 3 a (resistive l oad), electrical life: 1,000,000 operat ions, load power supply voltage: 75 to 250 vac (dc loads cannot be connected.), minimum applicable load: 5 v, 10 ma, leakage current: 5 ma max. (250 vac, 60 hz) auxiliary output number of outputs 3 output specifica- tions relay output: spst-no, 250 vac, 3 a (resistive load), electrical life: 100,000 ope rations, minimum applicable load: 5 v, 10 ma event input number of inputs 2 external contact in- put specifications contact input: on: 1 k ? max., off: 100 k ? min. non-contact input: on: residual voltage: 1. 5 v max., off: leakage current: 0.1 ma max. current flow: approx. 7 ma per contact external power supply for es1b 12 vdc 10%, 20 ma, short-circuit pr otection circuit provided setting method digital setting using front panel keys indication method 11-segment digital display and individual indicators (7-segm ents displays also possible) character height: e5an: pv: 15.8 mm, sv: 9.5 mm, mv: 6.8 mm; e5en: pv: 11.8 mm, sv: 8.1 mm, mv: 5.8 mm content of 3-level display: pv/sv/mv, pv/sv/multi-sp, or soak time remain ? number of digits: 4 for pv, sv, and mv multi sp up to four set points (sp0 to sp3) can be saved and selected using event inputs, key operations, or serial communications. bank switching not supported. other functions manual output, heating/cooling control, loop burnout alar m, sp ramp, other alarm functions, heater burnout detection, 40% at, 100% at, mv limiter, input digita l filter, self-tuning, temper ature input shift, run/stop, protection functions, control output on/off counter, extraction of square root, mv change rate limit, logic operations, pv/sv status display, simple pr ogram, automatic cooli ng coefficient adjustment ambient operating temperature ? 10 to 55 c (with no condensation or icin g), for 3-year warranty: ? 10 to 50 c ambient operating humidity 25% to 85% storage temperature ? 25 to 65 c (with no condensation or icing)
e5an/e5en 23 e5cn e5cn-u (48 x 48 mm) e5cn-h (48 x 48 mm) e5an-h (96 x 96 mm) e5en-h (48 x 96 mm) operation safety precautions e5an (96 x 96 mm) e5en (48 x 96 mm) input ranges thermocouple/platinum resistance thermometer (uni versal inputs) models with analog inputs shaded settings are the default settings. input type platinum resistance thermometer thermocouple infrared temperature sensor analog input name pt100 jpt100 k j t e l u n r s b w pl ii 10 to 70 c 60 to 120 c 115 to 165 c 140 to 260 c 0 to 50 mv temperature range ( c) 2300 1800 1700 1600 1500 1400 1300 1200 1100 1000 900 800 700 600 500 400 300 200 100 0 ? 100.0 ? 200.0 2300 usable in the following ranges by scaling: ? 1999 to 9999 or ? 199.9 to 999.9 1800 1700 1700 1300 1300 1300 850 850 850 600 500.0 500.0 500.0 400.0 400 400.0 400 400.0 260 120 165 100.0 100.0 90 100 0.0 0.0 00 00 0 0 0 0 ? 20.0 ? 100 ? 20.0 ? 100 ? 200 ? 199.9 ? 199.9 ? 200 ? 200 ? 199.9 ? 200 ? 200 ? 199.9 ? 200 setting number 01234 5 6 7 8 9 1011121314151617182425 19 20 21 22 23 shaded settings are the default settings. the applicable standards for the input types are as follows: k, j, t, e, n, r, s, b: jis c 1602-1995, iec 584-1 l: fe-cuni, din 43710-1985 u: cu-cuni, din 43710-1985 w: w5re/w26re, astm e988-1990 jpt100: jis c 1604-1989, jis c 1606-1989 pt100: jis c 1604-1997, iec 751 pl ii: according to platinel ii electromot ive force charts from basf (previously engelhard) input type current voltage input specification 4 to 20ma 0 to 20 ma 1 to 5 v 0 to 5 v 0 to 10 v setting range usable in the following ranges by scaling: ? 1999 to 9999, ? 199.9 to 999.9, ? 19.99 to 99.99 or ? 1.999 to 9.999 setting number 01234
e5an/e5en 24 e5cn e5cn-u (48 x 48 mm) e5cn-h (48 x 48 mm) e5an-h (96 x 96 mm) e5en-h (48 x 96 mm) safety precautions operation e5an (96 x 96 mm) e5en (48 x 96 mm) alarm outputs each alarm can be independently set to one of the following 13 alarm types. the default is 2: upper limit . auxiliary outputs are allocated for alarms. on delays and off delay s (0 to 999 s) can also be specified. note: for models with heater burnout, ssr failure, and heater overcurrent detection , alarm 1 will be an or output of the alarm select ed from the following alarm types and the alarms for heater burnout, ssr failure, and heater over current. to output only a heater burnout a larm, ssr failure alarm, and heater overcurrent alarm for alarm 1, set the alarm type to 0 (i.e., no alarm function). ? 1. with set values 1, 4 and 5, t he upper and lower limit values can be set independently for each alar m type, and are expressed as ?l? and ?h.? ? 2. set value: 1, upper- and lower-limit alarm ? 3. set value: 4, upper- and lower-limit range ? 4. set value: 5, upper- and lower-limit with standby sequence for upper- and lower-limit alarm described above  case 1 and 2 always off when the upper-limit and lower-limit hysteresis overlaps.  case 3: always off ? 5. set value: 5, upper- and lower-limit with standby sequence always off when the upper-limit and lower-limit hysteresis overlaps. set value alarm type alarm output operation when x is positive when x is negative 0 alarm function off output off 1 ? 1 upper- and lower-limit ? 2 2 upper limit 3 lower limit 4 ? 1 upper- and lower-limit range ? 3 5 ? 1 upper- and lower-limit with standby sequence ? 5 ? 4 6 upper-limit with standby sequence 7 lower-limit with standby sequence 8 absolute-value upper-limit 9 absolute-value lower-limit 10 absolute-value upper-limit with standby sequence 11 absolute-value lower-limit with standby sequence 12 lba (for alarm 1 only) --- 13 pv change rate alarm --- on off sp lh sp x on off sp x on off sp x on off sp x on off sp lh on off sp lh on off sp x on off sp x on off sp x on off sp x on off 0 x on off 0 x on off 0 x on off 0 x on off 0 x on off 0 x on off 0 x on off 0 x on off lh h < 0, l > 0 ? h ? < ? l ? sp case 1 lh h > 0, l < 0 ? h ? > ? l ? sp case 2 l h h < 0, l < 0 sp l h h < 0, l > 0 ? h ? ? l ? sp l h h > 0, l < 0 ? h ? ? l ? sp case 3 (always on) lhsp case 1 lh sp case 2 l hsp l l hsp h sp case 3 (always off) h < 0, l > 0 ? h ? < ? l ? h > 0, l < 0 ? h ? > ? l ? h < 0, l < 0 h < 0, l > 0 ? h ? ? l ? h > 0, l < 0 ? h ? ? l ?
e5an/e5en 25 e5cn e5cn-u (48 x 48 mm) e5cn-h (48 x 48 mm) e5an-h (96 x 96 mm) e5en-h (48 x 96 mm) operation safety precautions e5an (96 x 96 mm) e5en (48 x 96 mm) characteristics ? 1. the indication accuracy of k thermocouples in the ? 200 to 1300 c range, t and n thermocouples at a temperature of ? 100 c max., and u and l thermocouples at any temperatures is 2 c 1 digit max. the indication accuracy of the b thermocouple at a temperature of 400 c max. is not specified. the indication accuracy of b thermocouples in the 400 to 800 c range is 3 c max. the indication accuracy of the r and s thermocouples at a temperature of 200 c max. is 3 c 1 digit max. the indication accu racy of w thermocouples is 0.3 of pv or 3 c, whichever is greater, 1 digit max. the indication accu racy of pl ii thermocouples is 0.3 of pv or 2 c, whichever is greater, 1digit max. ? 2. ambient temperature: ? 10 c to 23 c to 55 , voltage range: ? 15% to 10% of rated voltage ? 3. k thermocouple at ? 100 c max.: 10 c max. ? 4. ?eu? stands for engineering unit and is used as the unit after scaling. fo r a temperature sensor, the eu is c or f. ? 5. when robust tuning (rt) is on, the differentia l time is 0.0 to 999.9 (in units of 0.1 s). ? 6. external communications (rs-232c or rs-485) and cable communications for the setup tool can be used at the same time. indication accuracy thermocouple: ( 0.3% of indicated value or 1 c, whichever is greater) 1 digit max. ? 1 platinum resistance thermometer: ( 0.2% of indicated value or 0.8 c, whichever is greater) 1 digit max. analog input: 0.2% fs 1 digit max. ct input: 5% fs 1 digit max. transfer output accuracy 0.3% fs max. influence of temperature ? 2 thermocouple input (r, s, b, w, pl ii): ( 1% of pv or 10 c, whichever is greater) 1 digit max. other thermocouple input: ( 1% of pv or 4 c, whichever is greater) 1 digit max. ? 3 platinum resistance thermometer: ( 1% of pv or 2 c, whichever is greater) 1 digit max. analog input: ( 1%fs) 1 digit max. influence of voltage ? 2 input sampling period 250 ms hysteresis models with thermocouple/platinum resist ance thermometer input (universal inpu t): 0.1 to 999.9 eu (in units of 0.1 eu) ? 4 models with analog input: 0.01 to 99.99% fs (in units of 0.01% fs) proportional band (p) models with thermocouple/platinum resist ance thermometer input (universal inpu t): 0.1 to 999.9 eu (in units of 0.1 eu) ? 4 models with analog input: 0.1 to 999.9% fs (in units of 0.1% fs) integral time (i) 0 to 3999 s (in units of 1 s) derivative time (d) 0 to 3999 s (in units of 1 s) ? 5 control period 0.5, 1 to 99 s (in units of 1 s) manual reset value 0.0 to 100.0% (in units of 0.1%) alarm setting range ? 1999 to 9999 (decimal point position depends on input type) affect of signal source resistance thermocouple: 0.1 c/ ? max. (100 ? max.) platinum resistance thermometer: 0.1 c/ ? max. (10 ? max.) insulation resistance 20 m ? min. (at 500 vdc) dielectric strength 2,300 vac, 50 or 60 hz for 1 min (bet ween terminals with different charge) vibration resistance malfunction 10 to 55 hz, 20 m/s 2 for 10 min each in x, y, and z directions destruction 10 to 55 hz, 0.75-mm single amplitude for 2 hrs each in x, y, and z directions shock resistance malfunction 100 m/s 2 , 3 times each in x, y, and z directions destruction 300 m/s 2 , 3 times each in x, y, and z directions weight e5an controller: approx. 310 g, mounting bracket: approx. 100 g e5en controller: approx. 260 g, mounting bracket: approx. 100 g degree of protection front panel: ip66, rear case: ip20, terminals: ip00 memory protection non-volatile memory (number of writes: 1,000,000 times) setup tool cx-thermo version 4.0 or higher setup tool port provided on the bottom of the e5an and e5en. an e58-cifq1 usb-serial conversion cable is requir ed to connect the computer to the e5an and e5en ? 6 standards approved standards ul 61010-1, csa c22.2 no. 1010-1 conformed standards en 61010-1 (iec 61010-1): pollution le vel 2, overcurrent category ii emc emi: en 61326 radiated interference electromagnetic fi eld strength: en 55011 group 1, class a noise terminal voltage: en 55011 group 1, class a ems: en 61326 esd immunity: en 61000-4-2 electromagnetic field immunity: en 61000-4-3 burst noise immunity: en 61000-4-4 conducted disturbance immunity: en 61000-4-6 surge immunity: en 61000-4-5 power frequency magnetic fiel d immunity: en 61000-4-8 voltage dip/interrupting immunity: en 61000-4-11
e5an/e5en 26 e5cn e5cn-u (48 x 48 mm) e5cn-h (48 x 48 mm) e5an-h (96 x 96 mm) e5en-h (48 x 96 mm) safety precautions operation e5an (96 x 96 mm) e5en (48 x 96 mm) usb-serial conversion cable note: a driver must be installed in the personal computer. refer to installation information in the operation manual for the conversion cable. communications specifications ? the baud rate, data bit length, stop bit length, and vertical parity can be individually set using the communications setting level. current transformer (order separately) ratings heater burnout alarms, ssr failure alarms, and heater overcurrent alarms ? 1. for heater burnout alarms, the heat er current will be measured when the control output is on, and the output assigned to the alarm 1 function will turn on if the heater current is lower than the set value (i.e., heater burnout detection current value). ? 2. for ssr failure alarms, the heater current will be measured when the control output is off, and the output assigned to the alarm 1 function will turn on if the heater current is higher than the set value (i.e., ssr failure detection current value). ? 3. for heater overcurrent alarms , the heater current will be measured when the control output is on, and the output assigned to the alarm 1 function will turn on if the heater current is higher than the set value (i.e., heater overcurrent detection current value). electrical life expectancy curve for relays (reference values) note: do not connect a dc load to a controller with a long-life relay output. applicable os windows 2000, xp, or vista applicable software thermo mini, cx-thermo version 4.0 or higher applicable models e5an/e5en/e5cn/e5cn-u/e5an- h/e5en-h/e5cn-h usb interface standard conforms to usb specification 1.1. dte speed 38400 bps connector specifications computer: usb (type a plug) temperature controller: setup tool port (on bottom of controller) power supply bus power (supplied from usb host controller.) power supply voltage 5 vdc current consumption 70 ma ambient operating temper- ature 0 to 55c (with no condensation or icing) ambient operating humidity 10% to 80% storage temperature ? 20 to 60c (with no condensation or icing) storage humidity 10% to 80% altitude 2,000 m max. weight approx. 100 g transmission line connection method rs-485: multipoint rs-232c: point-to-point communications rs-485 (two-wire, half duplex) or rs- 232c synchronization method start-stop synchronization protocol compoway/f, sysway, or modbus baud rate 1200, 2400, 4800, 9600, 19200, 38400, or 57600 bps transmission code ascii data bit length ? 7 or 8 bits stop bit length ? 1 or 2 bits error detection vertical parity (none, even, odd) frame check sequence (fcs) with sysway block check character (bcc) with compoway/f or crc-16 modbus flow control none interface rs-485, rs-232c retry function none communications buffer 217 bytes communications response wait time 0 to 99 ms default: 20 ms dielectric strength 1,000 vac for 1 min vibration resistance 50 hz, 98 m/s 2 weight e54-ct1: approx. 11.5 g, e54-ct3: approx. 50 g accessories (e54-ct3 only) armatures (2) plugs (2) ct input (for heater cur- rent detection) models with detection for single- phase heaters: one input models with detection for single- phase or three-phase heaters: two inputs maximum heater current 50 a ac input current indication accuracy 5% fs 1 digit max. heater burnout alarm set- ting range ? 1 0.1 to 49.9 a (in units of 0.1 a) minimum detection on time: 100 ms ssr failure alarm setting range ? 2 0.1 to 49.9 a (in units of 0.1 a) minimum detection off time: 100 ms heater overcurrent alarm setting range ? 3 0.1 to 49.9 a (in units of 0.1 a) minimum detection on time: 100 ms 500 300 100 50 30 10 5 3 1 0123456 e5an/e5en 250 vac, 30 vdc (resistive load) cos = 1 switching current (a) life ( 10 4 operations)
e5an/e5en 27 e5cn e5cn-u (48 x 48 mm) e5cn-h (48 x 48 mm) e5an-h (96 x 96 mm) e5en-h (48 x 96 mm) operation safety precautions e5an (96 x 96 mm) e5en (48 x 96 mm) external connections ? a voltage output (control output 1, for drivi ng ssr) is not electrically insulated from the internal circui ts. when using a gro unding thermocouple, do not connect any of the control output te rminals to ground. if the control output terminals are connected to ground, errors w ill occur in the measured temperature values as a result of leakage current. the voltage output (control output 2, for driving ssr) has basic insulation provided for the internal circuit. ? consult with your omron r epresentative before using the external power supply for th e es1b for any other purpose. a heater burnout alarm, heater short alarm, heater overcurrent alarm, or input alarm is sent to the output to which the alarm 1 function is assigned. communications e53-en03 rs-485 b ( + ) 11 a ( ? ) 12 do not use 13 e53-en01 rs-232c sd 11 rd 12 sg 13 e53-akb event inputs 11 12 13 250 vac, 3 a (resistive load) relay outputs  100 to 240 vac  24 vac/vdc (no polarity) current output 0 to 20 ma dc voltage output (for driving ssr) 12 vdc, 40 ma load: 600 ? max. 4 to 20 ma dc relay output 250 vac, 5a (resistive load) voltage output (for driving ssr) 12 vdc, 21 ma long-life relay output 250 vac, 3 a (resistive load) ev ev2 ct1/ct2 control output 2 auxiliary output 1, 2, 3 control output 1 input power supply auxiliary output 2 1 2 3 4 5 13 14 15 6 7 8 9 10 16 17 18 19 control output 1 analog input tc/pt multi-input b v ma auxiliary output 3 20 ct1 ct2 ev1 ev2 ct1/ct2 control output 2 + - control output 2 do not use + - external power supply 12 vdc, 20 ma do not use external power supply do not use b a do not use do not use do not use auxiliary output 1 event inputs 11 12 controllers option units
e5an/e5en 28 e5cn e5cn-u (48 x 48 mm) e5cn-h (48 x 48 mm) e5an-h (96 x 96 mm) e5en-h (48 x 96 mm) safety precautions operation e5an (96 x 96 mm) e5en (48 x 96 mm) nomenclature ? a 2-level display when shipped from the factory. a 3-level displa y is activated if parameters ar e initialized. for details on t he third display level, refer to the user?s manual, basic type (cat. no. h156). dimensions (unit: mm) sub3 ha sub2 out2 out1 cmw stop pf a/m manu sub1 mv sv pv e5an operation indicators programmable function key/ auto/manual key no.1 display no. 2 display no. 3 display up key down key temperature unit mode key level key e5an e5en pf a/m mv sv pv e5en sub2 sub3 stop out1 manu cmw out2 sub1 ha operation indicators temperature unit operation indicators mode key level key no.1 display no.2 display no.3 display up key down key programmable function key/ auto/manual key 96 96 mounting bracket (accessory) waterproof packing (accessory) terminal cover (e53-cov16) (accessory) crimp terminal size: m3.5 112 91 79.2 6 2 92 +0.8 0 92 +0.8 0 92 +0.8 0 (96 number of units ? 3.5) +1.0 0 120 min. group mounting does not allow waterproofing. mounted separately group mounted  recommended panel thickness is 1 to 8mm.  group mounting is not possible in the vertical direction. (maintain the specified mounting space between controllers.)  to mount the controller so that it is waterproof, insert the waterproof packing onto the controller.  when two or more controllers are mounted, make sure that the surrounding temperature does not exceed the allowable operating temperature specified in the specifications. e5an
e5an/e5en 29 e5cn e5cn-u (48 x 48 mm) e5cn-h (48 x 48 mm) e5an-h (96 x 96 mm) e5en-h (48 x 96 mm) operation safety precautions e5an (96 x 96 mm) e5en (48 x 96 mm) accessories (order separately) mounting bracket (accessory) waterproof packing (accessory) terminal cover (e53-cov16) (accessory) crimp terminal size: m3.5 96 112 48 79.2 6 91 2 e5en 92 +0.8 0 92 +0.8 0 45 +0.6 0 120 min. (48 number of units ? 2.5) +1.0 0 group mounting does not allow waterproofing. mounted separately group mounted  recommended panel thickness is 1 to 8 mm.  group mounting is not possible in the vertical direction. (maintain the specified mounting space between controllers.)  to mount the controller so that it is waterproof, insert the waterproof packing onto the controller.  when two or more controllers are mounted, make sure that the surrounding temperature does not exceed the allowable operating temperature specified in the specifications. (2,100) 250 1,765 usb connector (type a plug) serial connecto r led (rd) led (sd) usb-serial conversion cable e58-cifq1 terminal covers e53-cov16 (six covers provided.) 10 1.2 3.2 44.8
e5an/e5en 30 e5cn e5cn-u (48 x 48 mm) e5cn-h (48 x 48 mm) e5an-h (96 x 96 mm) e5en-h (48 x 96 mm) safety precautions operation e5an (96 x 96 mm) e5en (48 x 96 mm) current transformers waterproo f pack i ng y92s-p4 (for din 96 96) order the waterproof packing separately if it becomes lost or damaged. the waterproof packing can be used to achieve an ip66 degree of protection. (deterioration, shrinking, or harde ning of the waterproof packing may occur depending on the operating env ironment. therefore, periodic replacement is recommended to ensure the level of waterproofing specified in ip66. the time for periodic replacement depends on the operating environment. be sure to c onfirm this point at your site. consider one year a rough standard. omron shall not be liable for the level of water resistance if the customer does not perform periodic replacement.) the waterproof packing does not need to be attached if a waterproof structure is not required. y92s-p5 (for din 48 96) e54-ct3 accessory ? armature 30 21 15 5.8 dia. 25 3 40 10.5 2.8 7.5 10 two, 3.5 dia. 40 40 30 12 dia. 9 2.36 dia. 15 30 two, m3 (depth: 4) approx. 3 dia. 18 (22) approx. 6 dia. plug armature lead e54-ct1 e54-ct3 connection example ? plug e54-ct1 thru-current (io) vs. output voltage (eo) (reference values) maximum continuous heater current: 50 a (50/60 hz) number of windings: 400 2 winding resistance: 18 2 ? thru-current (io) a (r.m.s.) 1 10 100 ma 1 10 100 1,000 a output voltage (eo) v (r.m.s.) 100 v 50 hz distortion factor 10% 3% 1% 100 ? r l = 10 ? 10 1 100 mv 10 1 100 v 10 1 k ? e54-ct3 thru-current (io) vs. output voltage (eo) (reference values) maximum continuous heater current: 120 a (50/60 hz) (maximum continuous heater current for an omron temperature controller is 50 a.) number of windings: 4002 winding resistance: 80.8 ? 3% 1% 1 k ? 100 ? 50 ? r l = 10 ? 500 ? distor- tion factor 10% thru-current (io) a (r.m.s.) 1 10 100 ma 1 10 100 1,000 a output voltage (eo) v (r.m.s.) 100 v 50 hz 10 1 100 mv 10 1 100 v 10
31 e5cn e5cn-u (48 x 48 mm) operation safety precautions e5an (96 x 96 mm) e5en (48 x 96 mm) e5an-h (96 x 96 mm) e5en-h (48 x 96 mm) e5cn-h (48 x 48 mm) advanced digital temperature controller e5cn-h (48 x 48 mm) a new high-performance controller : high resolution, high speed, and high input accuracy. logic operations and preventive maintenance function. ? high-resolution displa y with 5 digits/0.01 c display in a compact controller (48 x 48 mm). ? high-speed sampling cycle of 60 ms. ? high accuracy thermocouple/pt input: 0.1% of pv analog input: 0.1% fs ? universal inputs on all models (thermocouple, pt, or analog input) to handle various sensors with one controller. ? a pv/sv-status display function can be set to automatically alternate between displaying the status of the temperature controller (auto/ manual, run/stop, and alarms) and the pv or sv. ? flexible contact outputs with logic operations (and, or, and delays) set from the support software (cx-thermo ver. 4.0) ? preventive maintenance for relays in the temperature controller using a control output on/off counter. main i/o functions 48 48 mm e5cn-h refer to safety precautions on page 66. universal sensor inputs ? universal thermocouple/pt/analog (current/voltage) inputs. indication accuracy ? thermocouple/pt input: 0.1% of pv ? analog input: 0.1% fs 2-level display: pv and sv 5-digit display with high resolution of 0.01 c e5cn-h event inputs ? none ? two sampling period ? 60 ms control output 1 ? relay output ? voltage output (for driving ssr) ? current output ? linear voltage output control output 2 ? none ? voltage output (for driving ssr) auxiliary outputs ? two ? auto/manual switching ? temperature controller status display ? simple program function ? logic operations ? control output on/off count alarm ? pv change rate alarm ? models also available with rs-485 or rs-232c communications this data sheet is provided as a guideline for selecting products . be sure to refer to the following user manuals for applicati on precautions and other information required for operati on before attempting to use the product. e5cn-h/e5an-h/e5en-h digital controllers user's manual advanced type (cat. no. h157) e5cn-h/e5an-h/e5en-h digital controllers comm unications manual advanced type (cat. no. h159)
e5cn-h 32 e5cn e5cn-u (48 x 48 mm) safety precautions operation e5an (96 x 96 mm) e5en (48 x 96 mm) e5an-h (96 x 96 mm) e5en-h (48 x 96 mm) e5cn-h (48 x 48 mm) lineup note: models with one control output and models with two cont rol outputs can be used for heating/cooling control. model number structure model number legend controllers 1. type h: advanced 2. control output 1 r: relay output q: voltage output (for driving ssr) c: current output v: linear voltage output 3. auxiliary outputs 2: two outputs 4. option 1 m: option unit can be mounted. 5. power supply voltage blank: 100 to 240 vac d: 24 vac/vdc 6. case color blank: black w: silver 7. terminal cover -500: with terminal cover option units 1. applicable controller cn: e5cn-h or e5cn 2. function 1 blank: none q: control output 2 (voltage output for driving ssr) p: power supply for sensor c: current output 3. function 2 blank: none h: heater burnout/ssr failure/heater overcurrent detection (ct1) hh: heater burnout/ssr failure/heater overcurrent detection (ct2) b: two event inputs 03: rs-485 communications h03: heater burnout/ssr failure/heater overcurrent detection (ct1) + rs-485 communications hb: heater burnout/ssr failure/heater overcurrent detection (ct1) + two event inputs hh03: heater burnout/ssr failure/heater overcurrent detection (ct2) + rs-485 communications h01: heater burnout/ssr failure/heater overcurrent detection (ct1)/rs-232c communications f: transfer output bf: two event inputs/transfer output 4. version n2: available only to models released after january 2008 note: not all combinations of function 1 and function 2 specifications are possible for option units (e53- @@@@ ). terminal block e5cn-h advanced type fully universal input 2 control outputs 1 control output 2 auxiliary outputs 2 auxiliary outputs 1 2345 6 7 e5cn- @@@ m @ - @ -500 1 234 e53- @@@@
e5cn-h 33 e5cn e5cn-u (48 x 48 mm) operation safety precautions e5an (96 x 96 mm) e5en (48 x 96 mm) e5an-h (96 x 96 mm) e5en-h (48 x 96 mm) e5cn-h (48 x 48 mm) ordering information controllers option units one of the following option units can be mounted to provide the e5cn wi th additional functions. note: these option units are applicable only to models released after january 2008. accessories (order separately) usb-serial conversion cable terminal cover note: 1. the terminal cover comes with the e5cn- @@@ -500 models. 2. the e53-cov10 cannot be used. waterproof packing note: waterproof packing is included with the controller only for models with terminal blocks. current transformers (cts) adapter note: use this adapter when the panel has been previously prepared for the e5b @ . cx-thermo support software size case color power supply voltage auxiliary output control output 1 model 1/16 din 48 48 78 (w h d) black 100 to 240 vac 2 relay output e5cn-hr2m-500 voltage output (for driving ssr) e5cn-hq2m-500 current output e5cn-hc2m-500 linear voltage output e5cn-hv2m-500 24 vac/vdc 2 relay output e5cn-hr2md-500 voltage output (for driving ssr) e5cn-hq2md-500 current output e5cn-hc2md-500 linear voltage output e5cn-hv2md-500 silver 100 to 240 vac 2 relay output e5cn-hr2m-w-500 voltage output (for driving ssr) e5cn-hq2m-w-500 current output e5cn-hc2m-w-500 24 vac/vdc 2 relay output e5cn-hr2md-w-500 voltage output (for driving ssr) e5cn-hq2md-w-500 current output e5cn-hc2md-w-500 functions model communications rs-485 3-phase heater burnout/ssr failure/ heater overcurrent detection e53-cnhh03n2 heater burnout/ssr failure/ heater overcurrent detection event inputs e53-cnhbn2 communications rs-485 control output 2 (voltage for driving ssr) e53-cnq03n2 communications rs-485 heater burnout/ssr failure/ heater overcurrent detection e53-cnh03n2 communications rs-485 e53-cn03n2 event inputs e53-cnbn2 heater burnout/ssr failure/ heater overcurrent detection control output 2 (voltage for driving ssr) e53-cnqhn2 3-phase heater burnout/ssr failure/ heater overcurrent detection control output 2 (voltage for driving ssr) e53-cnqhhn2 event inputs control output 2 (voltage for driving ssr) e53-cnqbn2 control output 2 (voltage for driving ssr) transfer output e53-cnqfn2 event inputs transfer output e53-cnbfn2 communications rs-232c control output 2 (voltage for driving ssr) e53-cnq01n2 communications rs-232c e53-cn01n2 communications rs-232c heater burnout/ssr failure/ heater overcurrent detection e53-cnh01n2 model e58-cifq1 model e53-cov17 model y92s-29 hole diameter model 5.8 dia. e54-ct1 12.0 dia. e54-ct3 connectable models model terminal type y92f-45 model est2-2c-mv4
e5cn-h 34 e5cn e5cn-u (48 x 48 mm) safety precautions operation e5an (96 x 96 mm) e5en (48 x 96 mm) e5an-h (96 x 96 mm) e5en-h (48 x 96 mm) e5cn-h (48 x 48 mm) specifications ratings ? for models with current outputs, control output 1 can be used as a transfer output. power supply voltage no d in model number: 100 to 240 vac, 50/60 hz d in model number: 24 vac, 50/60 hz; 24 vdc operating voltage range 85% to 110% of rated supply voltage power consumption 100 to 240 vac: 8.5 va (max.) (e5cn-hr2 at 100 vac: 3.0 va) 24 vac/vdc: 5.5 va (24 vac)/3.5 w (24 vdc) (max.) (e5cn-hr2d at 24 vac: 2.7 va) sensor input any of the following can be selected (i.e., fully universal input). thermocouple: k, j, t, e, l, u, n, r, s, b, w, or pl ii platinum resistance thermometer: pt100 or jpt100 current input: 4 to 20 ma or 0 to 20 ma voltage input: 1 to 5 v, 0 to 5 v, or 0 to 10 v input impedance current input: 150 ? max., voltage input: 1 m ? min. (use a 1:1 connection when connecting the es2-hb.) control method on/off control or 2-pid control (with auto-tuning) control output relay output spst-no, 250 vac, 3 a (resistive load), electrical life : 100,000 operations, minimum applicable load: 5 v, 10 ma voltage output (for driving ssr) output voltage: 12 vdc 15% (pnp), max. load current: 21 ma, wi th short-circuit protection circuit current output 4 to 20 ma dc/0 to 20 ma dc, load: 600 ? max., resolution: approx. 10,000 ? linear voltage out- put 0 to 10 vdc (load: 1 k ? min.), resolution: approx. 10,000 auxilia- ry output number of outputs 2 max. output specifica- tions relay output: spst-no, 250 vac, 3 a (resistive load), electrical life: 100,000 oper ations, minimum applicable load: 5 v, 10 ma event input number of outputs 2 external contact input specifica- tions contact input: on: 1 k ? max., off: 100 k ? min. non-contact input: on: residual voltage: 1.5 v max., off: leakage current: 0.1 ma max. current flow: approx. 7 ma per contact logic opera- tions number of opera- tions 8 max. (combinations can be made using work bits.) operations ? logic operation: any of the following four patterns can be selected. the input status may be inverted. (a and b) or (c and d), (a or c) and (b or d), a or b or c or d, a and b and c and d (a, b, c, and d are four inputs.) ? delay: on delay or off delay for the re sults of the logic operation given above. setting time: 0 to 9999 s or 0 to 9999 min ? output inversion: possible outputs one work bit per operation work bit assign- ments any of the following can be assigned to up to eight work bits (logic operation results) : event input operations, auxiliary outputs, or control outputs. transfer outputs number of outputs 1 max. output specifications current output: 4 to 20 ma dc, load: 600 ? max., resolution at 4 to 20 ma: approx. 10,000 rsp input not supported setting method digital setting using front panel keys indication method 11-segment digital display and i ndividual indicators (7-segment s displays also possible) character height: pv: 11 mm, sv: 6.5 mm bank switching supported (number of banks: 8) local sp, alarm settings, pid sets (pid cons tants, mv upper limit, mv lower limit, etc.) other functions manual output, heating/cooling contro l, loop burnout alarm, sp ramp, other alarm functions, heater burnout detection, 40% at, 100% at, mv limiter, input digital fi lter, self-tuning, temperature input shift, run/stop, protection functions, control output on/off counter, extraction of squar e root, mv change rate limit, pv/sv status display, logic operations, aut omatic cooling c oefficient adjustment ambient operating tempera- ture ? 10 to 55 c (with no condensation or ici ng), for 3-year warranty: ? 10 to 50 c ambient operating humidity 25% to 85% storage temperature ? 25 to 65 c (with no condensation or icing)
e5cn-h 35 e5cn e5cn-u (48 x 48 mm) operation safety precautions e5an (96 x 96 mm) e5en (48 x 96 mm) e5an-h (96 x 96 mm) e5en-h (48 x 96 mm) e5cn-h (48 x 48 mm) input ranges thermocouple/platinum resistan ce thermometer/analog input (fully universal inputs) input type platinum resistance thermometer thermocouple analog input name pt100 jpt100 k j t e l u n r s b w pl ii 4 to 20 ma 0 to 20 ma 1 to 5v 0 to 5v 0 to 10 v temperature range ( c) 2300 1800 1700 1600 1500 1400 1300 1200 1100 1000 900 800 700 600 500 400 300 200 100 0 ? 100 ? 200 2300.0 usable in the following ranges by scaling: ? 19999 to 32400, ? 1999.9 to 3240.0, ? 199.99 to 324.00, or ? 19.999 to 32.400 1800.0 1700.01700.0 1300.0 1300.0 1300.0 850.0 850.0 850.0 600.0 500.0 500.0 500.0 400.0 400.0 400.0 400.0 400.0 200.00 200.00 200.00 200.00 100.0 100.0 100.0 0.0 0.0 0.0 0.0 0.0 0.0 ? 50.00 ? 20.0 ? 50.00 ? 100.0 ? 20.0 ? 50.00 ? 50.00 ? 100.0 ? 200.0 ? 199.9 ? 199.9 ? 200.0 ? 200.0 ? 199.9 ? 200.0 ? 200.0 ? 199.9 ? 200.0 setting number 0122434 5 6 21 7 8 22 9 1023111213141516171819202526272829 shaded settings are the default settings. the applicable standards for the input types are as follows: k, j, t, e, n, r, s, b: jis c 1602-1995, iec 584-1 l: fe-cuni, din 43710-1985 u: cu-cuni, din 43710-1985 w: w5re/w26re, astm e988-1990 jpt100: jis c 1604-1989, jis c 1606-1989 pt100: jis c 1604-1997, iec 751 pl ii: according to platinel ii electromotive force charts from basf (previously engelhard)
e5cn-h 36 e5cn e5cn-u (48 x 48 mm) safety precautions operation e5an (96 x 96 mm) e5en (48 x 96 mm) e5an-h (96 x 96 mm) e5en-h (48 x 96 mm) e5cn-h (48 x 48 mm) alarm outputs each alarm can be independently set to one of the following 13 alarm types. the default is 2: upper limit . auxiliary outputs are allocated for alarms. on delays and off delay s (0 to 999 s) can also be specified. note: for models with heater burnout, ssr failure, and heater overcurrent detection , alarm 1 will be an or output of the alarm select ed from the following alarm types and the alarms for heater burnout, ssr failure, and heater over current. to output only a heater burnout a larm, ssr failure alarm, and heater overcurrent alarm for alarm 1, set the alarm type to 0 (i.e., no alarm function). ? 1. with set values 1, 4 and 5, t he upper and lower limit values can be set independently for each alar m type, and are expressed as ?l? and ?h.? ? 2. set value: 1, upper- and lower-limit alarm ? 3. set value: 4, upper- and lower-limit range ? 4. set value: 5, upper- and lower-limit with standby sequence for upper- and lower-limit alarm described above  case 1 and 2 always off when the upper-limit and lo wer-limit hysteresis overlaps.  case 3: always off ? 5. set value: 5, upper- and lower-limit with standby sequence always off when the upper-limit and lower-limit hysteresis overlaps. set value alarm type alarm output operation when x is positive when x is negative 0 alarm function off output off 1 ? 1 upper- and lower- limit ? 2 2 upper limit 3lower limit 4 ? 1 upper- and lower- limit range ? 3 5 ? 1 upper- and lower- limit with standby sequence ? 4 6 upper-limit with standby sequence 7 lower-limit with standby sequence 8 absolute-value upper-limit 9 absolute-value lower-limit 10 absolute-value upper-limit with standby sequence 11 absolute-value lower-limit with standby sequence 12 lba (for alarm 1 only) --- 13 pv change rate alarm --- on off sp lh sp x on off sp x on off sp x on off sp x on off sp lh on off sp lh on off ? 5 sp x on off sp x on off sp x on off sp x on off 0 x on off 0 x on off 0 x on off 0 x on off 0 x on off 0 x on off 0 x on off 0 x on off lh h < 0, l > 0 ? h ? < ? l ? sp case 1 lh h > 0, l < 0 ? h ? > ? l ? sp case 2 l h h < 0, l < 0 sp l h h < 0, l > 0 ? h ? ? l ? sp l h h > 0, l < 0 ? h ? ? l ? sp case 3 (always on) lhsp case 1 lh sp case 2 l hsp l l hsp h sp case 3 (always off) h < 0, l > 0 ? h ? < ? l ? h > 0, l < 0 ? h ? > ? l ? h < 0, l < 0 h < 0, l > 0 ? h ? ? l ? h > 0, l < 0 ? h ? ? l ?
e5cn-h 37 e5cn e5cn-u (48 x 48 mm) operation safety precautions e5an (96 x 96 mm) e5en (48 x 96 mm) e5an-h (96 x 96 mm) e5en-h (48 x 96 mm) e5cn-h (48 x 48 mm) characteristics ? 1. the indication accuracy of k thermocouples in the ? 200 to 1300 c range, t and n thermocouples at a temperature of ? 100 c max., and u and l thermocouples at any temperatures is 2 c 1 digit max. the indication accuracy of the b thermocouple at a temperature of 400 c max. is not specified. the indication accuracy of b thermocouples in the 400 to 800 c range is 3 c max. the indication accuracy of the r and s thermocouples at a temperature of 200 c max. is 3 c 1 digit max. the indication accu racy of w thermocouples is 0.3 of pv or 3 c, whichever is greater, 1 digit max. the indication accu racy of pl ii thermocouples is 0.3 of pv or 2 c, whichever is greater, 1digit max. ? 2. ambient temperature: ? 10 c to 23 c to 55 c, voltage range: ? 15% to 10% of rated voltage ? 3. k thermocouple at ? 100 c max.: 10 c max. ? 4. external communications (rs-232c or rs-485) and cable communications for the setup tool can be used at the same time. indication accuracy thermocouple: ( 0.1% of indicated value or 1 c, whichever is greater) 1 digit max. ? 1 platinum resistance thermometer: ( 0.1% of indicated value or 0.5 c, whichever is greater) 1 digit max. analog input: 0.1% fs 1 digit max. ct input: 5% fs 1 digit max. transfer output accuracy 0.3% fs max. influence of temperature ? 2 thermocouple input (r, s, b, w, plii): ( 1% of pv or 10 c, whichever is greater) 1 digit max. other thermocouple input: ( 1% of pv or 4 c, whichever is greater) 1 digit max. ? 3 platinum resistance thermometer: ( 1% of pv or 2 c, whichever is greater) 1 digit max. analog input: ( 1%fs) 1 digit max. influence of voltage ? 2 input sampling period 60 ms hysteresis temperature input: 0.1 to 3240.0 c or f (in units of 0.1 c or f) analog input: 0.01% to 99.99% fs (in units of 0.01% fs) proportional band (p) temperature input: 0.1 to 3240.0 c or f (in units of 0.1 c or f) analog input: 0.1% to 999.9% fs (in units of 0.1% fs) integral time (i) 0.0 to 3240.0 s (in units of 0.1 s) derivative time (d) 0.0 to 3240.0 s (in units of 0.1 s) control period 0.5, 1 to 99 s (in units of 1 s) manual reset value 0.0 to 100.0% (in units of 0.1%) alarm setting range ? 19999 to 32400 (decimal point position depends on input type) affect of signal source resistance thermocouple: 0.1 c/ ? max. (100 ? max.) platinum resistance thermometer: 0.1 c/ ? max. (10 ? max.) insulation resistance 20 m ? min. (at 500 vdc) dielectric strength 2,300 vac, 50 or 60 hz for 1 min (bet ween terminals with different charge) vibration resistance malfunction 10 to 55 hz, 20 m/s 2 for 10 min each in x, y, and z directions destruction 10 to 55 hz, 0.75-mm single amplitude for 2 h rs each in x, y, and z directions shock resistance malfunction 100 m/s 2 , 3 times each in x, y, and z directions destruction 300 m/s 2 , 3 times each in x, y, and z directions weight controller: approx. 150 g, mounting bracket: approx. 10 g degree of protection front panel: ip66, rear case: ip20, terminals: ip00 memory protection non-volatile memory (number of writes: 1,000,000 times) setup tool cx-thermo version 4.0 or higher setup tool port provided on the bottom of the e5cn-h. use this port to connect a computer to the e5cn-h. an e58-cifq1 usb-serial conver sion cable is required to connect the computer to the e5cn-h. ? 4 standards approved standards ul 61010-1, csa c22.2 no. 1010-1 conformed standards en 61010-1 (iec 61010-1): pollution level 2, overcurrent category ii emc emi: en 61326 radiated interference electromagnetic fi eld strength: en 55011 group 1, class a noise terminal voltage: en 55011 group 1, class a ems: en 61326 esd immunity: en 61000-4-2 electromagnetic field immunity: en 61000-4-3 burst noise immunity: en 61000-4-4 conducted disturbance immunity: en 61000-4-6 surge immunity: en 61000-4-5 power frequency magnetic field immunity: en 61000-4-8 voltage dip/interrupting immunity: en 61000-4-11
e5cn-h 38 e5cn e5cn-u (48 x 48 mm) safety precautions operation e5an (96 x 96 mm) e5en (48 x 96 mm) e5an-h (96 x 96 mm) e5en-h (48 x 96 mm) e5cn-h (48 x 48 mm) usb-serial conversion cable note: a driver must be installed in the personal computer. refer to installation information in the operation manual for the conversion cable. communications specifications ? the baud rate, data bit length, stop bit length, and vertical parity can be individually set using the communications setting level. current transformer (order separately) ratings heater burnout alarms, ssr failure alarms, and heater overcurrent alarms ? 1. for heater burnout alarms, the heat er current will be measured when the control output is on, and the output assigned to the alarm 1 function will turn on if the heater current is lower than the set value (i.e., heater burnout detection current value). ? 2. for ssr failure alarms, the heater current will be measured when the control output is off, and the output assigned to the alarm 1 function will turn on if the heater current is higher than the set value (i.e., ssr failure detection current value). ? 3. for heater overcurrent alarms , the heater current will be measured when the control output is on, and the output assigned to the alarm 1 function will turn on if the heater current is higher than the set value (i.e., heater overcurrent detection current value). electrical life expectancy curve for relays (reference values) applicable os windows 2000, xp, or vista applicable software thermo mini, cx-thermo version 4.0 or higher applicable models e5an/e5en/e5cn/e5cn-u/ e5an-h/e5en-h/e5cn-h usb interface standard conforms to usb specification 1.1. dte speed 38400 bps connector specifications computer: usb (type a plug) temperature controller: setup tool port (on bottom of controller) power supply bus power (supplied from usb host controller.) power supply voltage 5 vdc current consumption 70 ma ambient operating tempera- ture 0 to 55c (with no condensation or icing) ambient operating humidity 10% to 80% storage temperature ? 20 to 60c (with no condensation or icing) storage humidity 10% to 80% altitude 2,000 m max. weight approx. 100 g transmission line connection method rs-485: multipoint rs-232c: point-to-point communications rs-485 (two-wire, half duplex)/rs-232c synchronization method start-stop synchronization protocol compoway/f, sysway, or modbus baud rate 1200, 2400, 4800, 9600, 19200, 38400, or 57600 bps transmission code ascii (compoway/f, sysway) rtu (modbus) data bit length ? 7 or 8 bits stop bit length ? 1 or 2 bits error detection vertical parity (none, even, odd) frame check sequence (fcs) with sysway block check character (bcc) with compoway/f or crc-16 modbus flow control none interface rs-485, rs-232c retry function none communications buffer 217 bytes communications response wait time 0 to 99 ms default: 20 ms dielectric strength 1,000 vac for 1 min vibration resistance 50 hz, 98 m/s 2 weight e54-ct1: approx. 11.5 g, e54-ct3: approx. 50 g accessories (e54-ct3 only) armatures (2) plugs (2) ct input (for heater cur- rent detection) models with detection for single- phase heaters: one input models with detection for single- phase or three-phase heaters: two inputs maximum heater current 50 a ac input current indication accuracy 5% fs 1 digit max. heater burnout alarm set- ting range ? 1 0.1 to 49.9 a (in units of 0.1 a) minimum detection on time: 100 ms ssr failure alarm setting range ? 2 0.1 to 49.9 a (in units of 0.1 a) minimum detection off time: 100 ms heater overcurrent alarm setting range ? 3 0.1 to 49.9 a (in units of 0.1 a) minimum detection on time: 100 ms 500 300 100 50 30 10 5 3 1 0123456 e5cn-h 250 vac, 30 vdc (resistive load) cos = 1 switching current (a) life ( 10 4 operations)
e5cn-h 39 e5cn e5cn-u (48 x 48 mm) operation safety precautions e5an (96 x 96 mm) e5en (48 x 96 mm) e5an-h (96 x 96 mm) e5en-h (48 x 96 mm) e5cn-h (48 x 48 mm) external connections ? a voltage output (control output, for driving ssr) is not electrical ly insulated from the intern al circuits. when using a groun ding thermocouple, do not connect any of the control output te rminals to ground. if the control output terminals are connected to ground, errors w ill occur in the measured temperature values as a result of leakage current. controllers note: wire all voltage input terminals correctly. the controller may fail if voltage input termi nals are wired incorrectly. control output 1 a b b control output 1 v do not use do not use do not use ma auxiliary outputs (relay outputs) ? input power supply auxiliary outputs (relay outputs) 250 vac, 3 a (resistive load) ? 100 to 240 vac ? 24 vac/vdc (no polarity) auxiliary output 2 auxiliary output 1 6 7 8 9 10 11 12 13 14 15 1 3 2 4 5 relay output 250 vac, 3 a (resistive load) voltage output (for driving ssr) 12 vdc, 21 ma linear voltage output 0 to 10 vac load 1 k ? max. current output 0 to 20 ma dc 4 to 20 ma dc load 600 ? max. a heater burnout alarm, ssr failure, heater overcurrent alarm, or input alarm is sent to the output to which the alarm 1 function is assigned. rs-232c ct1 ct1 ct1 11 12 13 14 15 communications (rs-232) and ct 11 12 13 14 15 ct2 ct1 control output 2 and ct2 11 12 13 14 15 control output 2 and transfer output 11 12 13 14 15 ev1 ev2 event inputs e53-cnbn2 e53-cnqhhn2 11 12 13 14 15 ct1 control output 2 and ct e53-cnqhn2 e53-cn03n2 e53-cnq03n2 e53-cnh03n2 e53-cnhh03n2 e53-cnqfn2 e53-cn01n2 e53-cnh01n2 e53-cnq01n2 e53-cnqbn2 e53-cnhbn2 e53-cnbfn2 sd rs-232c rd sg sd rd sg rs-232c 11 12 13 14 15 communications (rs-232) sd rd sg 11 12 13 14 15 11 12 13 14 15 rs-485 communications (rs-485) and ct 11 12 13 14 15 ct2 ct1 rs-485 communications (rs-485) and ct2 communications (rs-232) and control output 2 11 12 13 14 15 rs-485 communications (rs-485) and control output 2 11 12 13 14 15 rs-485 communications (rs-485) 11 12 13 14 15 ev1 ev2 event inputs and control output 2 11 12 13 14 15 ev1 ev2 event inputs and ct 11 12 13 14 15 ev1 ev2 event inputs and transfer output transfer output do not use do not use do not use do not use do not use do not use do not use do not use do not use do not use do not use 4 to 20 ma dc (load 600 ? max.) 4 to 20 ma dc (load 600 ? max.) b ( + ) a ( ? ) b ( + ) a ( ? ) b ( + ) a ( ? ) b ( + ) a ( ? ) control output 2 12 vdc 21 ma control output 2 12 vdc 21 ma control output 2 12 vdc 21 ma control output 2 12 vdc 21 ma transfer output control output 2 12 vdc 21 ma control output 2 12 vdc 21 ma option units
e5cn-h 40 e5cn e5cn-u (48 x 48 mm) safety precautions operation e5an (96 x 96 mm) e5en (48 x 96 mm) e5an-h (96 x 96 mm) e5en-h (48 x 96 mm) e5cn-h (48 x 48 mm) nomenclature dimensions (unit: mm) accessories (order separately) usb-serial conversion cable e5cn-h e5cn-h sub1 out1 out2 stop cwm manu sub2 sub3 ha level key temperature unit no. 1 display no. 2 display up key mode key down key operation indicators 45 +0.6 0 45 +0.6 0 45 +0.6 0 60 min. (48 number of units ? 2.5) +1.0 0 group mounting does not allow waterproofing. panel cutout mounted separately group mounted 48 48 44.8 44.8 48.8 6 1.5 91 78 58 terminal cover (e53-cov17) (accessory) mounting adapter (accessory) waterproof packing (accessory) e5cn-h  recommended panel thickness is 1 to 5mm.  group mounting is not possible in the vertical direction. (maintain the specified mounting space between controllers.)  to mount the controller so that it is waterproof, insert the waterproof packing onto the controller.  when two or more controllers are mounted, make sure that the surrounding temperature does not exceed the allowable operating temperature specified in the specifications. note: the terminal block cannot be removed. (2,100) 250 1,765 usb connector (type a plug) serial connecto r led indicator (rd) led indicator (sd) e58-cifq1
e5cn-h 41 e5cn e5cn-u (48 x 48 mm) operation safety precautions e5an (96 x 96 mm) e5en (48 x 96 mm) e5an-h (96 x 96 mm) e5en-h (48 x 96 mm) e5cn-h (48 x 48 mm) current transformers 48 48.8 22 9.1 terminal cover e53-cov17 waterproof packing y92s-29 (for din 48 48) order the waterproof packing separately if it becomes lost or damaged. the waterproof packing can be used to achieve an ip66 degree of protection. (deterioration, shrinking, or har dening of the waterproof packing may occur depending on the operating env ironment. therefore, periodic replacement is recommended to ensure the level of waterproofing specified in ip66. the time fo r periodic replacement depends on the operating environment. be sure to c onfirm this point at your site. consider one year a rough standard. omron shall not be liable for the level of water resistance if th e customer does not perform periodic replacement.) the waterproof packing does not need to be attached if a waterproof structure is not required. note: the e53-cov10 can not be used. e54-ct3 accessory ? armature 30 21 15 5.8 dia. 25 3 40 10.5 2.8 7.5 10 two, 3.5 dia. 40 40 30 12 dia. 9 2.36 dia. 15 30 two, m3 (depth: 4) approx. 3 dia. 18 (22) approx. 6 dia. plug armature lead e54-ct1 e54-ct3 connection example ? plug e54-ct1 thru-current (io) vs. output voltage (eo) (reference values) maximum continuous heater current: 50 a (50/60 hz) number of windings: 400 2 winding resistance: 18 2 ? thru-current (io) a (r.m.s.) 1 10 100 ma 1 10 100 1,000 a output voltage (eo) v (r.m.s.) 100 v 50 hz distortion factor 10% 3% 1% 100 ? r l = 10 ? 10 1 100 mv 10 1 100 v 10 1 k ? e54-ct3 thru-current (io) vs. output voltage (eo) (reference values) maximum continuous heater current: 120 a (50/60 hz) (maximum continuous heater current for an omron temperature controller is 50 a.) number of windings: 400 2 winding resistance: 8 0.8 ? 3% 1% 1 k ? 100 ? 50 ? r l = 10 ? 500 ? distor- tion factor 10% thru-current (io) a (r.m.s.) 1 10 100 ma 1 10 100 1,000 a output voltage (eo) v (r.m.s.) 100 v 50 hz 10 1 100 mv 10 1 100 v 10
e5cn-h 42 e5cn e5cn-u (48 x 48 mm) safety precautions operation e5an (96 x 96 mm) e5en (48 x 96 mm) e5an-h (96 x 96 mm) e5en-h (48 x 96 mm) e5cn-h (48 x 48 mm) adapter fixture (accessory) 69.6 to 77.6 87 67 67 72 72 76 4.7 72 72 48 48 panel (1 to 8 mm) 77.3 (to back of e5cn-h) 2.2 4.7 y92f-45 note: use this adapter when the panel has already been prepared for the e5b @ . mounted to e5cn-h
43 e5cn e5cn-u (48 x 48 mm) e5cn-h (48 x 48 mm) operation safety precautions e5an (96 x 96 mm) e5en (48 x 96 mm) e5an-h (96 x 96 mm) e5en-h (48 x 96 mm) advanced digital temperature controller e5an-h/e5en-h (96 x 96 mm and 48 x 96 mm) a new high-performance controller : high resolution, high speed, and high input accuracy. logic operations and preven tive maintenance function. plus infrared port on front panel. ? high-resolution di splay with 5 digits/0.01c display. ? high-speed sampling cycle of 60 ms. ? high accuracy thermocouple/pt input: 0.1% of pv analog input: 0.1% fs ? universal inputs on all models (thermocouple, pt, or analog input) to handle various sensors with one controller. models also available with remote sp. ? a pv/sv-status display function can be set to automatically alternate between displaying the status of the temperature controller (auto/manual, run/stop, and alarms) and the pv or sv. ? flexible contact outputs with logic operations (and, or, and delays) set from the support software (cx-thermo ver. 4.0) ? preventive maintenance for relays in the temperature controller using a control output on/off counter. ? model available with position-proportional control main i/o functions 96 96 mm e5an-h 48 96 mm e5en-h refer to safety precautions on page 66 .  auto/manual switching  temperature controller status display  simple program function  logic operations  control output on/off count alarm  pv change rate alarm ? models available with rs-485, rs-422, or rs-232c communications event inputs  none  two  four universal sensor inputs  universal thermocouple/ pt/analog (current/voltage) inputs. indication accuracy ? thermocouple/pt input: 0.1% of pv ? analog input: 0.1% fs sampling period ? 60 ms pf key (programmable key function) auxiliary outputs  two  three remote sp input ? one 3-level display simultaneously displays set items, such as the pv, sv, and mv. 5-digit display with high resolution of 0.01 c infrared port e5an-h e5en-h computer support software cx-thermo usb control output 1 (built-in)  ssr outputs output unit  relay output  voltage output (for driving ssr)  current output  linear voltage output control output 2 (built-in)  ssr outputs output unit  relay output  voltage output (for driving ssr)  current output  linear voltage output
e5an-h/e5en-h 44 e5cn e5cn-u (48 x 48 mm) e5cn-h (48 x 48 mm) safety precautions operation e5an (96 x 96 mm) e5en (48 x 96 mm) e5an-h (96 x 96 mm) e5en-h (48 x 96 mm) lineup note: the controller can be used for heating/cooling control even if only 1 control output is used. model number structure model number legend controllers 1. type h: advanced 2. control mode blank: standard or heating/cooling control p: position-proportional control 3. control output 1 a: control output unit r: relay output s: ssr output 4. control output 2 a: control output unit r: relay output s: ssr output 5. auxiliary outputs 2: two outputs 3: three outputs 6. option 1 blank: none h: heater burnout/ssr failure/heater overcurrent detection (ct1) hh: heater burnout/ssr failure/heater overcurrent detection (ct2) 7. option 2 b: two event inputs bf: event input + transfer output 8. option 3 m: option unit can be mounted. 9. power supply voltage blank: 100 to 240 vac d: 24 vac/vdc 10.case color blank: black w: silver 11.terminal cover -500: with terminal cover option units 1. function en01: rs-232c communications en02: rs-422 communications en03: rs-485 communications akb: event input output units 1. control output r: relay output q: voltage output (for driving ssr) q3: voltage output (for driving ssr) + 24 vdc (npn) q4: voltage output (for driving ssr) + 24 vdc (pnp) c3: current output + 4 to 20 ma dc c3d: current output + 0 to 20 ma dc v34: linear voltage output + 0 to 10 vdc v35: linear voltage output + 0 to 5 vdc 2. version blank: available for e5an-h/e5en-h and e5ak/e5ek. n: available only for e5an-h/e5en-h. e5an-h/e5en-h advanced type 2 control outputs 1 control output 2 auxiliary outputs 2 auxiliary outputs terminal block fully universal input 1 23456789 10 11 e5an/e5en- @@@@@@@ m @ - @ -500 1 e53- @ 1 2 e53- @@ this data sheet is provided as a guideline for selecting products . be sure to refer to the following user manuals for applicati on precautions and other information required for operati on before attempting to use the product. e5cn-h/e5an-h/e5en-h digital controllers user's manual advanced type (cat. no. h157) e5cn-h/e5an-h/e5en-h digital controllers comm unications manual advanced type (cat. no. h159)
e5an-h/e5en-h 45 e5cn e5cn-u (48 x 48 mm) e5cn-h (48 x 48 mm) operation safety precautions e5an (96 x 96 mm) e5en (48 x 96 mm) e5an-h (96 x 96 mm) e5en-h (48 x 96 mm) ordering information e5an-h size case color power supply voltage control method auxiliary output control output 1/2 heater burnout optional functions model event inputs transfer output rsp 1/4 din 96 96 78 (w h d) black 100 to 240 vac basic 2 control output unit 21 2 4 to 20-ma input e5an-haa2hbm-500 ssr outputs 212 4 to 20-ma input e5an-hss2hbm-500 control output unit 22 2 4 to 20-ma output 4 to 20-ma input e5an-haa2hhbfm-500 ssr outputs 222 4 to 20-ma output 4 to 20-ma input e5an-hss2hhbfm-500 3 control output unit 22 4 to 20-ma output 4 to 20-ma input e5an-haa3bfm-500 ssr outputs 22 4 to 20-ma output 4 to 20-ma input e5an-hss3bfm-500 valve 2 relay outputs 22 4 to 20-ma input e5an-hprr2bm-500 relay outputs 22 4 to 20-ma output 4 to 20-ma input e5an-hprr2bfm-500 24 vac/ vdc basic 2 control output unit 21 2 4 to 20-ma input e5an-haa2hbmd-500 ssr outputs 212 4 to 20-ma input e5an-hss2hbmd-500 control output unit 22 2 4 to 20-ma output 4 to 20-ma input e5an-haa2hhbfmd-500 ssr outputs 222 4 to 20-ma output 4 to 20-ma input e5an-hss2hhbfmd-500 3 control output unit 22 4 to 20-ma output 4 to 20-ma input e5an-haa3bfmd-500 ssr outputs 22 4 to 20-ma output 4 to 20-ma input e5an-hss3bfmd-500 valve 2 relay outputs 22 4 to 20-ma input e5an-hprr2bmd-500 relay outputs 22 4 to 20-ma output 4 to 20-ma input e5an-hprr2bfmd-500 silver 100 to 240 vac basic 2 control output unit 21 2 4 to 20-ma input e5an-haa2hbm-w-500 control output unit 22 2 4 to 20-ma output 4 to 20-ma input e5an-haa2hhbfm-w-500 24 vac/ vdc control output unit 21 2 4 to 20-ma input e5an-haa2hbmd-w-500
e5an-h/e5en-h 46 e5cn e5cn-u (48 x 48 mm) e5cn-h (48 x 48 mm) safety precautions operation e5an (96 x 96 mm) e5en (48 x 96 mm) e5an-h (96 x 96 mm) e5en-h (48 x 96 mm) e5en-h accessories (order separately) output units usb-infrared conversion cable usb-serial conversion cable terminal cover note: the terminal cover comes with the e5cn- @@@ -500 models. waterproof packing note: the waterproof packing is included with the controller. current transformers (cts) cx-thermo support software size case color power supply voltage control method auxil- iary output control output 1/2 heater burn- out optional functions model event inputs transfer output rsp 1/8 din 48 96 78 (w h d) black 100 to 240 vac basic 2 control output unit 21 2 4 to 20-ma input e5en-haa2hbm-500 ssr outputs 212 4 to 20-ma input e5en-hss2hbm-500 control output unit 22 2 4 to 20-ma output 4 to 20-ma input e5en-haa2hhbfm-500 ssr outputs 222 4 to 20-ma output 4 to 20-ma input e5en-hss2hhbfm-500 3 control output unit 22 4 to 20-ma output 4 to 20-ma input e5en-haa3bfm-500 ssr outputs 22 4 to 20-ma output 4 to 20-ma input e5en-hss3bfm-500 valve 2 relay outputs 22 4 to 20-ma input e5en-hprr2bm-500 relay outputs 22 4 to 20-ma output 4 to 20-ma input e5en-hprr2bfm-500 24 vac/ vdc basic 2 control output unit 21 2 4 to 20-ma input e5en-haa2hbmd-500 ssr outputs 212 4 to 20-ma input e5en-hss2hbmd-500 control output unit 22 2 4 to 20-ma output 4 to 20-ma input e5en-haa2hhbfmd-500 ssr outputs 222 4 to 20-ma output 4 to 20-ma input e5en-hss2hhbfmd-500 3 control output unit 22 4 to 20-ma output 4 to 20-ma input e5en-haa3bfmd-500 ssr outputs 22 4 to 20-ma output 4 to 20-ma input e5en-hss3bfmd-500 valve 2 relay outputs 22 4 to 20-ma input e5en-hprr2bmd-500 relay outputs 22 4 to 20-ma output 4 to 20-ma input e5en-hprr2bfmd-500 silver 100 to 240 vac basic 2 control output unit 21 2 4 to 20-ma input e5en-haa2hbm-w-500 control output unit 22 2 4 to 20-ma output 4 to 20-ma input e5en-haa2hhbfm-w-500 24 vac/ vdc control output unit 21 2 4 to 20-ma input e5en-haa2hbmd-w-500 output unit model specifications relay output e53-rn spst-no, 250 vac, 5 a (resistive load), electrical life: 100,000 operations voltage output (for driving ssr) e53-qn 12 vdc (pnp), max. load current: 40-ma, with short- circuit protection e53-q3 24 vdc (npn), max. load current: 20-ma, with short- circuit protection e53-q4 24 vdc (pnp), max. load current: 20-ma, with short- circuit protection current output e53-c3n 4 to 20-ma dc, load: 600 ? max., resolution: approx. 10,000 e53-c3dn 0 to 20-ma dc, load: 600 ? max., resolution: approx. 10,000 linear voltage output e53-v34n 0 to 10 vdc, load: 1 k ? min., resolution: approx. 10,000 e53-v35n 0 to 5 vdc, load: 1 k ? min., resolution: approx. 10,000 model e58-cifir model e58-cifq1 connectable models model e5an-h e53-cov16 e5en-h connectable models model e5an-h y92s-p4 e5en-h y92s-p5 hole diameter model 5.8 dia. e54-ct1 12.0 dia. e54-ct3 model est2-2c-mv4
e5an-h/e5en-h 47 e5cn e5cn-u (48 x 48 mm) e5cn-h (48 x 48 mm) operation safety precautions e5an (96 x 96 mm) e5en (48 x 96 mm) e5an-h (96 x 96 mm) e5en-h (48 x 96 mm) specifications ratings power supply voltage no d in model number: 100 to 240 vac, 50/60 hz d in model number: 24 vac, 50/60 hz; 24 vdc operating voltage range 85% to 110% of rated supply voltage power consumption 100 to 240 vac: 12 va 24 vac/vdc: 8.5 va (24 vac)/5.5 w (24 vdc) sensor input any of the following can be selected. thermocouple: k, j, t, e, l, u, n, r, s, b, w, or pl ii platinum resistance thermometer: pt100 or jpt100 current input: 4 to 20 ma or 0 to 20 ma voltage input: 1 to 5 v, 0 to 5 v, or 0 to 10 v input impedance current input: 150 ? max., voltage input: 1 m ? min. (use a 1:1 connection when connecting the es2-hb.) control method on/off control or 2-pid control (with auto-tuning) control output relay output output unit (install the output unit (sold separately).) voltage output (for driving ssr) current output linear voltage output built-in ssr output 75 to 250 vac, 1 a (resistive load) relay output for posi- tion-proportional con- trol relay output: open and close: spst-no, 250 vac, 1 a (includi ng in-rush current), electrical life: 100,000 operations min. potentiometer input: must be between 100 ? and 2.5 k ? for maximum open position. auxiliary output number of outputs 2 or 3 max. output specifications relay output: spst-no, 250 vac, 3 a (resistive load), electrical life: 100,000 operations, minimum applicable load: 5 v, 10 ma event input number of outputs 2 or 4 (with an e53-akb) external contact input specifications contact input: on: 1 k ? max., off: 100 k ? min. non-contact input: on: residual voltage: 1.5 v max., off: leakage current: 0.1 ma max. current flow: approx. 7 ma per contact logic opera- tions number of operations 8 max. operations ? logic operation: any of the following four patterns can be selected. the input status may be inverted. (a and b) or (c and d), (a or c) and (b or d), a or b or c or d, a and b and c and d (a, b, c, and d are four inputs.) ? delay: on delay or off delay for the results of the logic operation given above. setting time: 0 to 9999 s or 0 to 9999 min ? output inversion: possible output one work bit per operation work bit assignment any of the following can be assigned to up to eight work bits (logic operation results): event input operations, auxiliary outputs, or control outputs. transfer outputs number of outputs 1 max. (depends on model. models with transfer output (f in model number) output specifications current output: 4 to 20 ma dc, load: 600 ? max., resolution at 4 to 20 ma: approx. 10,000 rsp input number of inputs 1 signal type current input: 4 to 20 ma (input impedance: 150 ? 10%) analog input scaling scaling of signal to engineering units (eu) ? 19,999 to 30,000 (display: 30,000 max.) accuracy ( 0.2% of fs) 1 digit max. input sampling period 60 ms setting method set digitally using keys on the front panel or by using the rsp input. indication method 11-segment digital display and individual indicators (7-segments displays also possible) character height: e5an-h: pv: 15.8 mm, sv: 9.5 mm, mv: 6.8 mm; e5en-h: pv: 11.8 mm, sv: 8.1 mm, mv: 5.8 mm content of 3-level display: pv/sv/mv, pv/sv/bank no., or soak time remain number of digits: 5 for pv and sv, 4 for mv bank switching supported (number of banks: 8) local sp, alarm settings, pid sets (pid const ants, mv upper limit, mv lower limit, etc.) other functions manual output, heating/cooling control, loop burnout alarm, sp ramp, other alarm functions, heater burnout detection, 40% at, 100% at, mv limiter, input digital filter, self-tuning, temperature input shift, run/stop, protection functions, control output on/off counter, extraction of square root, mv change rate limit, pv/sv status display, logic operations, automatic cooling coefficient adjustment ambient operating temperature ? 10 to 55 c (with no condensation or icing), for 3-year warranty: ? 10 to 50 c ambient operating humidity 25% to 85% storage temperature ? 25 to 65 c (with no condensation or icing)
e5an-h/e5en-h 48 e5cn e5cn-u (48 x 48 mm) e5cn-h (48 x 48 mm) safety precautions operation e5an (96 x 96 mm) e5en (48 x 96 mm) e5an-h (96 x 96 mm) e5en-h (48 x 96 mm) input ranges thermocouple/platinum r esistance thermometer ( fully universal inputs) input type platinum resistance thermometer thermocouple analog input name pt100 jpt100 k j t e l u n r s b w pl ii 4 to 20 m a 0 to 20 m a 1 to 5v 0 to 5v 0 to 10 v temperature range ( c) 2300 1800 1700 1600 1500 1400 1300 1200 1100 1000 900 800 700 600 500 400 300 200 100 0 ? 100.0 ? 200.0 2300.0 usable in the following ranges by scaling: ? 19999 to 32400, ? 1999.9 to 3240.0, ? 199.99 to 324.00, or ? 19.999 to 32.400 1800.0 1700.01700.0 1300.0 1300.0 1300.0 850.0 850.0 850.0 600.0 500.0 500.0 500.0 400.0 400.0 400.0 400.0 400.0 200.00 200.00 200.00 200.00 100.0 100.0 100.0 0.0 0.0 0.0 0.0 0.0 0.0 ? 50.00 ? 20.0 ? 50.00 ? 100.0 ? 20.0 ? 50.00 ? 50.00 ? 100.0 ? 200.0 ? 199.9 ? 199.9 ? 200.0 ? 200.0 ? 199.9 ? 200.0 ? 200.0 ? 199.9 ? 200.0 setting number 0122434 5 6 21 7 8 22 9 102311121314151617181920 25 26 27 28 29 shaded settings are the default settings. the applicable standards for the input types are as follows: k, j, t, e, n, r, s, b: jis c 1602-1995, iec 584-1 l: fe-cuni, din 43710-1985 u: cu-cuni, din 43710-1985 w: w5re/w26re, astm e988-1990 jpt100: jis c 1604-1989, jis c 1606-1989 pt100: jis c 1604-1997, iec 751 pl ii: according to platinel ii electromot ive force charts from basf (previously engelhard)
e5an-h/e5en-h 49 e5cn e5cn-u (48 x 48 mm) e5cn-h (48 x 48 mm) operation safety precautions e5an (96 x 96 mm) e5en (48 x 96 mm) e5an-h (96 x 96 mm) e5en-h (48 x 96 mm) alarm outputs each alarm can be independently set to one of t he following 15 alarm types. the default is 2: upper limit . auxiliary outputs are allocated for alarms. on delays a nd off delays (0 to 999 s) can also be specified. note: for models with heater burnout, ssr failure, and heater overcurr ent detection, alarm 1 will be an or output of the alarm select ed from the following alarm types and the alarms for heater burnout, ssr failure, and heater overcurrent. to output only a heater burnout a larm, ssr failure alarm, and heater overcurrent alarm for alarm 1, set the alarm type to 0 (i.e., no alarm function). ? 1.with set values 1, 4 and 5, th e upper and lower limit values can be set independently for each alarm ty pe, and are expressed as ?l? and ?h.? ? 2. set value: 1, upper- and lower-limit alarm ? 3. set value: 4, upper- and lower-limit range ? 4. set value: 5, upper- and lowe r-limit with standby sequence for upper- and lower-limit alarm described above  case 1 and 2 always off when the upper-limit and lower-limit hysteresis overlaps.  case 3: always off ? 5. set value: 5, upper- and lowe r-limit with standby sequence always off when the upper-limit and lower-limit hysteresis overlaps. ? 6. displayed when there is a remote sp input. set val- ue alarm type alarm output operation when x is positive when x is negative 0 alarm function off output off 1 ? 1 upper- and lower- limit ? 2 2 upper limit 3 lower limit 4 ? 1 upper- and lower- limit range ? 3 5 ? 1 upper- and lower- limit with standby sequence ? 5 ? 4 6 upper-limit with standby sequence 7 lower-limit with standby sequence 8 absolute-value upper-limit 9 absolute-value lower-limit 10 absolute-value upper-limit with standby sequence 11 absolute-value lower-limit with standby sequence 12 lba (for alarm 1 only) --- 13 pv change rate alarm --- 14 rsp absolute value upper limit ? 6 15 rsp absolute value lower limit ? 6 on off sp lh sp x on off sp x on off sp x on off sp x on off sp lh on off sp lh on off sp x on off sp x on off sp x on off sp x on off 0 x on off 0 x on off 0 x on off 0 x on off 0 x on off 0 x on off 0 x on off 0 x on off 0 x on off 0 x on off 0 x on off 0 x on off lh h < 0, l > 0 ? h ? < ? l ? sp case 1 lh h > 0, l < 0 ? h ? > ? l ? sp case 2 l h h < 0, l < 0 sp l h h < 0, l > 0 ? h ? ? l ? sp l h h > 0, l < 0 ? h ? ? l ? sp case 3 (always on) lh h < 0, l > 0 ? h ? < ? l ? sp case 1 lh h > 0, l < 0 ? h ? > ? l ? sp case 2 l h h < 0, l < 0 sp l h h < 0, l > 0 ? h ? ? l ? sp l h h > 0, l < 0 ? h ? ? l ? sp case 3 (always on)
e5an-h/e5en-h 50 e5cn e5cn-u (48 x 48 mm) e5cn-h (48 x 48 mm) safety precautions operation e5an (96 x 96 mm) e5en (48 x 96 mm) e5an-h (96 x 96 mm) e5en-h (48 x 96 mm) characteristics ? 1. the indication accuracy of k thermocouples in the ? 200 to 1300 c range, t and n thermocouples at a temperature of ? 100 c max., and u and l thermocouples at any temperatures is 2 c 1 digit max. the indication accuracy of the b thermocouple at a temperature of 400 c max. is not specified. the indication accu racy of b thermocouples in the 400 to 800 c range is 3 c max. the indication accuracy of the r and s thermocouples at a temperature of 200 c max. is 3 c 1 digit max. the indication accu racy of w thermocouples is 0.3% of pv or 3 c, whichever is greater, 1 digit max. the indication accuracy of pl ii thermocouples is 0.3% of pv or 2 c, whichever is greater, 1digit max. ? 2. ambient temperature: ? 10 c to 23 c to 55 c, voltage range: ? 15% to 10% of rated voltage ? 3. k thermocouple at ? 100 c max.: 10 c max. ? 4. external communications (rs-232c, rs-485, or rs-422) and cable communications for the setup tool can be used at the same time . indication accuracy thermocouple: ( 0.1% of indicated value or 1 c, whichever is greater) 1 digit max. ? 1 platinum resistance thermometer: ( 0.1% of indicated value or 0.5 c, whichever is greater) 1 digit max. analog input: 0.1% fs 1 digit max. ct input: 5% fs 1 digit max. potentiometer input: 5% fs 1 digit max. transfer output accuracy 0.3% fs max. influence of temperature ? 2 thermocouple input (r, s, b, w, pl ii): ( 1% of pv or 10 c, whichever is greater) 1 digit max. other thermocouple input: ( 1% of pv or 4 c, whichever is greater) 1 digit max. ? 3 platinum resistance thermometer: ( 1% of pv or 2 c, whichever is greater) 1 digit max. analog input: ( 1%fs) 1 digit max. influence of voltage ? 2 input sampling period 60 ms hysteresis temperature input: 0.1 to 3240.0 c or f (in units of 0.1 c or f) analog input: 0.01% to 99.99% fs (in units of 0.01% fs) proportional band (p) temperature input: 0.1 to 3240.0 c or f (in units of 0.1 c or f) analog input: 0.1% to 999.9% fs (in units of 0.1% fs) integral time (i) 0.0 to 3240.0 s (in units of 0.1 s) derivative time (d) 0.0 to 3240.0 s (in units of 0.1 s) control period 0.5, 1 to 99 s (in units of 1 s) manual reset value 0.0 to 100.0% (in units of 0.1%) alarm setting range ? 19999 to 32400 (decimal point position depends on input type) affect of signal source resistance thermocouple: 0.1 c/ ? max. (100 ? max.) platinum resistance thermometer: 0.1 c/ ? max. (10 ? max.) insulation resistance 20 m ? min. (at 500 vdc) dielectric strength 2,300 vac, 50 or 60 hz for 1 min (between terminals with different charge) vibration resistance malfunction 10 to 55 hz, 20 m/s 2 for 10 min each in x, y, and z directions destruction 10 to 55 hz, 0.75-mm single amplitude fo r 2 hrs each in x, y, and z directions shock resistance malfunction 100 m/s 2 , 3 times each in x, y, and z directions destruction 300 m/s 2 , 3 times each in x, y, and z directions weight e5an-h controller: approx. 310 g, mounting bracket: approx. 100 g e5en-h controller: approx. 260 g, mounting bracket: approx. 100 g degree of protection front panel: ip66, rear case: ip20, terminals: ip00 memory protection non-volatile memory (number of writes: 1,000,000 times) setup tool cx-thermo version 4.0 or higher setup tool port provided on the bottom of the e5an-h and e5en-h. an e58-cifq1 usb-serial conversion cable is required to connect the computer to the e5an-h and e5en-h. provided on the front of the e5an-h and e5en-h. an e58- cifir usb-infrared conversion cable is required to connect the computer to the e5an-h or e5en-h. ? 4 standards approved standards ul 61010-1, csa c22.2 no. 1010-1 conformed standards en 61010-1 (iec 61010-1): pollution level 2, overcurrent category ii emc emi: en 61326 radiated interference electromagnetic fiel d strength: en 55011 group 1, class a noise terminal voltage: en 55011 group 1, class a ems: en 61326 esd immunity: en 61000-4-2 electromagnetic field immunity: en 61000-4-3 burst noise immunity: en 61000-4-4 conducted disturbance immunity: en 61000-4-6 surge immunity: en 61000-4-5 power frequency magnetic field immunity: en 61000-4-8 voltage dip/interrupting immunity: en 61000-4-11
e5an-h/e5en-h 51 e5cn e5cn-u (48 x 48 mm) e5cn-h (48 x 48 mm) operation safety precautions e5an (96 x 96 mm) e5en (48 x 96 mm) e5an-h (96 x 96 mm) e5en-h (48 x 96 mm) usb-serial conversion cable note: a driver must be installed in the personal computer. refer to installation information in the operation manual for the conversion cable. communications specifications note: the baud rate, data bit length, stop bit length, and vertical parity can be individually set usi ng the communications setting level. current transformer (order separately) ratings usb-infrared conversion cable note: a driver must be installed in the personal computer. refer to installation information in the operation manual for the conversion cable. heater burnout alarms, ssr failure alarms, and heater overcurrent alarms ? 1. for heater burnout alarms, the heater current will be measured when the control output is on, and the output assigned to the alarm 1 function will turn on if the heater current is lower than the set value (i.e., heater burnout detection current value). ? 2. for ssr failure alarms, the heater current will be measured when the control output is off, and the output assigned to the alarm 1 function will turn on if the heater current is higher than the set value (i.e., ssr failure detection current value). ? 3. for heater overcurrent alarms, the heater current will be measured when the control output is on, and the output assigned to the alarm 1 function will turn on if the heater current is higher than the set value (i.e., heater overcurrent detection current value). applicable os windows 2000, xp, or vista applicable software thermo mini, cx-thermo version 4.0 or higher applicable models e5an/e5en/e5cn/e5cn-u/ e5an-h/e5en-h/e5cn-h usb interface standard conforms to usb specification 1.1. dte speed 38400 bps connector specifications computer: usb (type a plug) temperature controller: setup tool port (on bottom of controller) power supply bus power (supplied from usb host controller.) power supply voltage 5 vdc current consumption 70 ma ambient operating tempera- ture 0 to 55c (with no condensation or icing) ambient operating humidity 10% to 80% storage temperature ? 20 to 60c (with no condensation or icing) storage humidity 10% to 80% altitude 2,000 m max. weight approx. 100 g transmission line connection method rs-485, rs-422: multipoint rs-232c: point-to-point communications rs-485 (two-wire, half duplex) rs-422 (four-wire, hal f duplex) or rs-232c synchronization method start-stop synchronization protocol compoway/f, sysway, or modbus baud rate 1200, 2400, 4800, 9600, 19200, 38400, or 57600 bps transmission code ascii (compoway/f, sysway) rtu (modbus) data bit length ? 7 or 8 bits stop bit length ? 1 or 2 bits error detection vertical parity (none, even, odd) frame check sequence (fcs) with sysway block check character (bcc) with compoway/f or crc-16 modbus flow control none interface rs-485, rs-422, or rs-232c retry function none communications buffer 217 bytes communications response wait time 0 to 99 ms default: 20 ms dielectric strength 1,000 vac for 1 min vibration resistance 50 hz, 98 m/s 2 weight e54-ct1: approx. 11.5 g, e54-ct3: approx. 50 g accessories (e54-ct3 only) armatures (2) plugs (2) applicable os windows 2000, xp, or vista applicable software thermo mini, cx-thermo version 4.0 or higher applicable models e5an-h/e5en-h usb interface standard conforms to usb specification 1.1. dte speed 38400 bps connector specifications computer: usb (type a plug) temperature controller: infrared port (on front of controller) power supply bus power (supplied from usb host controller.) power supply voltage 5 vdc current consumption 80 ma ambient operating tempera- ture 0 to 55c (with no condensation or icing) ambient operating humidity 10% to 80% storage temperature ? 20 to 60c (with no condensation or icing) storage humidity 10% to 80% altitude 2,000 m max. weight approx. 130 g (with mounting adaptor) ct input (for heater current detec- tion) models with detection for single-phase heaters: one input models with detection for single-phase or three-phase heaters: two inputs maximum heater current 50 a ac input current indication accuracy 5% fs 1 digit max. heater burnout alarm set- ting range ? 1 0.1 to 49.9 a (in units of 0.1 a) minimum detection on time: 100 ms ssr failure alarm setting range ? 2 0.1 to 49.9 a (in units of 0.1 a) minimum detection off time: 100 ms heater overcurrent alarm setting range ? 3 0.1 to 49.9 a (in units of 0.1 a) minimum detection on time: 100 ms
e5an-h/e5en-h 52 e5cn e5cn-u (48 x 48 mm) e5cn-h (48 x 48 mm) safety precautions operation e5an (96 x 96 mm) e5en (48 x 96 mm) e5an-h (96 x 96 mm) e5en-h (48 x 96 mm) electrical life expectancy curve for relays (reference values) ssr outputs (out1/out2) ratings ? rated load voltage: 75 to 250 vac ? rated load current: 1 a (resistive load) note: 1. the load current must be within the derating curve. 2. there is no zero-cross function. derating curve for ssr ou tputs (reference values) condition a: ssr outputs 100% on condition b: ssr outputs 50% on with 2-s control cycle 500 300 100 50 30 10 5 3 1 0123456 e5an-h/e5en-h 250 vac, 30 vdc (resistive load) cos = 1 switching current (a) life ( 10 4 operations) 1.5 1.25 1 0.75 0.5 0.25 0 ? 10 0 10 20 30 40 50 55 45 60 ambient temperature ( c) load current i (a) out1/out2 condition a condition b
e5an-h/e5en-h 53 e5cn e5cn-u (48 x 48 mm) e5cn-h (48 x 48 mm) operation safety precautions e5an (96 x 96 mm) e5en (48 x 96 mm) e5an-h (96 x 96 mm) e5en-h (48 x 96 mm) external connections ? a voltage output (control output 1, for drivi ng ssr) is not electrically insulated from the internal circui ts. when using a gro unding thermocouple, do not connect any of the control output te rminals to ground. if the control output terminals are connected to ground, errors w ill occur in the measured temperature values as a result of leakage current. the voltage output (control output 2, for driving ssr) has basic insulation provided for the internal circuit note: wire all voltage input terminals correctly. the controller may fail if voltage input term inals are wired incorrectly. output unit control outputs 1, 2 relay outputs 250 vac, 5 a (resistive load) ssr outputs 75 to 250 vac, 1a (resistive load) models with position- proportional control 250 vac, 1 a (including inrush current) potentiometer rdb rda sg sdb sda 4 to 20 ma dc (load: 600 ? max.) 4 to 20 ma dc 1 2 3 4 5 6 7 8 9 10 21 22 23 24 25 26 27 28 29 30 21 22 23 24 25 26 27 28 29 30 21 22 23 24 25 26 27 28 29 30 11 12 13 14 15 16 17 18 19 20 ev4 ev3 transfer output remote sp input do not use ? 100 to 240 vac ? 24 vac/vdc (no polarity) input power supply auxiliary output 2 control output 1 b v ma control output 2 ct2 ct1 ev1 ev2 ct2 do not use do not use do not use b a c w o do not use do not use do not use do not use auxiliary output 1 event inputs ev1 ev2 event inputs communications b ( + ) a ( ? ) do not use b ( + ) a ( ? ) 11 12 13 21 22 e53-en03 rs-485 11 12 13 21 22 e53-en01 rs-232c sd rd sg do not use do not use 11 12 13 21 22 e53-akb 11 12 13 21 22 e53-en02 rs-422 control outputs 1, 2 relay output spst-no, 250 vac, 3 a (resistive load) auxiliary outputs 1, 2 relay output spdt, 250 vac, 3 a (resistive load) auxiliary output 3 a heater burnout alarm, ssr failure, heater overcurrent alarm, or input alarm is sent to the output to which the alarm 1 function is assigned. auxiliary output 3 14 15 16 option units controllers
e5an-h/e5en-h 54 e5cn e5cn-u (48 x 48 mm) e5cn-h (48 x 48 mm) safety precautions operation e5an (96 x 96 mm) e5en (48 x 96 mm) e5an-h (96 x 96 mm) e5en-h (48 x 96 mm) nomenclature dimensions (unit: mm) pf a/m sub3 ha sub2 out2 out1 cmw rsp stop manu sub1 mv sv pv ir e5an-h operation indicators no.1 display no.2 display no.3 display up key down key temperature unit mode key level key programmable function key/ auto/manual key e5an-h e5en-h ir pf a/m mv sv pv sub2 sub3 stop out1 rsp manu cmw out2 sub1 ha e5en-h operation indicators temperature unit operation indicators mode key level key no.1 display no.2 display no.3 display up key down key programmable function key/ auto/manual key mounting bracket (accessory) waterproof packing (accessory) terminal cover (e53-cov16) (accessory) crimp terminal size: m3.5 96 96 112 91 79.2 6 2 92 +0.8 0 92 +0.8 0 92 +0.8 0 (96 number of units ? 3.5) +1.0 0 120 min. group mounting does not allow waterproofing. mounted separately group mounted ?  recommended panel thickness is 1 to 8mm.  group mounting is not possible in the vertical direction. (maintain the specified mounting space between controllers.)  to mount the controller so that it is waterproof, insert the waterproof packing onto the controller.  when two or more controllers are mounted, make sure that the surrounding temperature does not exceed the allowable operating temperature specified in the specifications. e5an-h ? group mounting is not possible if an ssr output is used for control output 1 or 2 and the e53-c3n or e53-c3dn output unit is used. for these combinations, maintain the following mounting space between controllers. 92 +0.8 0 92 +0.8 0 110 min. 120 min.
e5an-h/e5en-h 55 e5cn e5cn-u (48 x 48 mm) e5cn-h (48 x 48 mm) operation safety precautions e5an (96 x 96 mm) e5en (48 x 96 mm) e5an-h (96 x 96 mm) e5en-h (48 x 96 mm) mounting bracket (accessory) waterproof packing (accessory) terminal cover (e53-cov16) (accessory) crimp terminal size: m3.5 96 112 48 79.2 6 91 2 e5en-h 92 +0.8 0 92 +0.8 0 45 +0.6 0 120 min. (48 number of units ? 2.5) +1.0 0 group mounting does not allow waterproofing. mounted separately group mounted ? ? recommended panel thickness is 1 to 8 mm.  group mounting is not possible in the vertical direction. (maintain the specified mounting space between controllers.)  when two or more controllers are mounted, make sure that the surrounding temperature does not exceed the allowable operating temperature specified in the specifications. ? group mounting is not possible if an ssr output is used for control output 1 or 2 and the e53-c3n or e53-c3dn output unit is used. for these combinations, maintain the following mounting space between controllers. 45 +0.6 0 60 min. 120 min. 92 +0.8 0
e5an-h/e5en-h 56 e5cn e5cn-u (48 x 48 mm) e5cn-h (48 x 48 mm) safety precautions operation e5an (96 x 96 mm) e5en (48 x 96 mm) e5an-h (96 x 96 mm) e5en-h (48 x 96 mm) accessories (order separately) (2,000) 54 4.6 dia. 35.8 17.8 usb connector (type a plug) led indicator: rd led indicator: sd usb-infrared conversion cable e58-cifir usb-infrared conversion cable 16 99.2 18.5 23.1 (75) 21.8 39 mounting adapter (accessory) with mounting adapter connected mounting adapter (2,100) 250 1,765 usb connector (type a plug) serial connecto r led indicator: rd led indicator: sd usb-serial conversion cable e58-cifq1 terminal covers e53-cov16 (six covers provided.) 10 1.2 3.2 44.8
e5an-h/e5en-h 57 e5cn e5cn-u (48 x 48 mm) e5cn-h (48 x 48 mm) operation safety precautions e5an (96 x 96 mm) e5en (48 x 96 mm) e5an-h (96 x 96 mm) e5en-h (48 x 96 mm) current transformers waterproof packing y92s-p4 (for din 96 96) order the waterproof packing separately if it becomes lost or damaged. the waterproof packing can be used to achieve an ip66 degree of protection. (deterioration, shrinking, or harde ning of the waterproof packing may occur depending on the operating env ironment. therefore, periodic replacement is recommended to ensure the level of waterproofing specified in ip66. the time for periodic replacement depends on the operating environment. be sure to c onfirm this point at your site. consider one year a rough standard. omron shall not be liable for the level of water resistance if the customer does not perform periodic replacement.) the waterproof packing does not need to be attached if a waterproof structure is not required. y92s-p5 (for din 48 96) e54-ct3 accessory ? armature 30 21 15 5.8 dia. 25 3 40 10.5 2.8 7.5 10 two, 3.5 dia. 40 40 30 12 dia. 9 2.36 dia. 15 30 two, m3 (depth 4) approx. 3 dia. 18 (22) approx. 6 dia. plug armature lead e54-ct1 e54-ct3 connection example ? plug e54-ct1 thru-current (io) vs. output voltage (eo) (reference values) maximum continuous heater current: 50 a (50/60 hz) number of windings: 400 2 winding resistance: 18 2 ? thru-current (io) a (r.m.s.) 1 10 100 ma 1 10 100 1,000 a output voltage (eo) v (r.m.s.) 100 v 50 hz distortion factor 10% 3% 1% 100 ? r l = 10 ? 10 1 100 mv 10 1 100 v 10 1 k ? e54-ct3 thru-current (io) vs. output voltage (eo) (reference values) maximum continuous heater current: 120 a (50/60 hz) (maximum continuous heater current for an omron temperature controller is 50 a.) number of windings: 4002 winding resistance: 80.8 ? 3% 1% 1 k ? 100 ? 50 ? r l = 10 ? 500 ? distor- tion factor 10% thru-current (io) a (r.m.s.) 1 10 100 ma 1 10 100 1,000 a output voltage (eo) v (r.m.s.) 100 v 50 hz 10 1 100 mv 10 1 100 v 10
e5 @ n/e5 @ n-h 58 e5cn e5cn-u (48 x 48 mm) e5an (96 x 96 mm) e5en (48 x 96 mm) e5cn-h (48 x 48 mm) e5an-h (96 x 96 mm) e5en-h (48 x 96 mm) safety precautions operation operation setting levels diagram this diagram shows all of the setting levels. to move to the advanced function setting level and calibration level, you must en ter passwords. some parameters are not displayed depending on the prot ect level setting and the conditions of use. control stops when you move from the operation level to the initial setting level. basic type ? 1. you can return to the operation level by executing a software reset. ? 2. it is not possible to move to other levels from the calibration level by operating the keys on the front panel. it can be done only by first turning off the power. ? 3. from the manual control level, key operations c an be used to move to the operation level only. ? 4. when the pf setting parameter is set to a-m for a controller with a pf key (e5an/e5en). ? 5. when the pf setting parameter is set to pfdp for a controller with a pf key (e5an/e5en) error displays (troubleshooting) when an error occurs, the no.1 display shows the error code. take necessary measure ac cording to the error code, referring the table below. note: if the input value exceeds the display limit ( ? 1999 to 9999), though it is within the control range, will be displayed under ? 1999 and above 9999. under these conditions, control out put and alarm output will operate normally. for details on the control range, refer to the e5cn/e5an/e5en digital temperature c ontrollers user's manual basic type (cat. no. h156). ? these errors are displayed only when the pv/sp is disp layed. errors are not di splayed for other displays. no.1 display meaning action status at error control output alarm output s.err (s. err) input error ? check the wiring of inputs for miswiring, di sconnections, and short-ci rcuits and check the input type. off operates as above the upper limit. e333 (e333) a/d converter error turn the power off then back on again. if the display remains the same, the controller must be repaired. if the display is restored to normal, then a probable cause can be external noise affecting the control system. check for external noise. off off e111 (e111) memory error turn the power off then back on again. if the display remains the same, the controller must be repaired. if the display is restored to normal, then a probable cause can be external noise affecting the control system. check for external noise. off off start in manual mode. 25 100 c 25 100 c a-m power on ? 3 manual mode press the o key or the pf key for at least 1 s. ? 4 press the o key for at least 3 s while a-m is displayed. ( a-m will flash after 1st second.) operation level press the o key for at least 1 s. press the o key for at least 1 s. input password. input password while amov is displayed. (set value ? 169) press the o key less than 1 s. press the o key for at least 3 s. (display will flash after 1st second.) control stops. press the o key for less than 1 s. press the o + m keys for at least 3 s. (display will flash after 1st second.) protect level control in progress level change not displayed for some models control stopped start in automatic mode. adjustment level pf key ? 5 pf key ? 5 initial setting level manual control level monitor/setting item level advanced function setting level calibration level press the pf key for at least 1 s. communica- tions setting level press the o + m keys for at least 1 s. ? 4 * 1 note: the time taken to move to the protect level can be adjusted by changing the ?move to protect level time? setting. ? 2
e5 @ n/e5 @ n-h 59 e5cn e5cn-u (48 x 48 mm) e5an (96 x 96 mm) e5en (48 x 96 mm) e5cn-h (48 x 48 mm) e5an-h (96 x 96 mm) e5en-h (48 x 96 mm) operation safety precautions advanced type ? 1. you can return to the operation level by executing a software reset. ? 2. it is not possible to move to other levels from the calibration level by operating the keys on the front panel. it can be done only by first turning off the power. ? 3. from the manual control level, key operations can be used to move to the operation level only. ? 4. when the pf setting parameter is set to a-m fo r a controller with a pf key (e5an-h/e5en-h). ? 5. when the pf setting parameter is set to pfdp for a controller with a pf key (e5an-h/e5en-h) error displays (t roubleshooting) when an error occurs, the no.1 display shows the error code. take necessary measure according to the error code, referring the table below. note: if the input value exceeds the display limit ( ? 19999 to 32400), though it is within the control range, will be displayed under ? 19999 and above 32400. under these conditions, control output and alarm output will operate normally. for details on the control range, refer to the e5cn-h/e5an-h/e5en-h digital cont rollers user's m anual advanced type (cat. no. h157). ? these errors are displayed only when the pv/sp is displayed. errors are not displayed for other displays. no.1 display meaning action status at error control output alarm output s.err (s. err) input error ? check the wiring of inputs for miswiring, disc onnections, and short-circuits and check the input type. off operates as above the upper limit. e333 (e333) a/d converter error turn the power off then back on again. if the display remains the same, the controller must be repaired. if the display is restored to normal, then a probable cause can be external noise affecting the control system. check for external noise. off off e111 (e111) memory error turn the power off then back on again. if the display remains the same, the controller must be repaired. if the display is restored to normal, then a probable cause can be external noise affecting the control system. check for external noise. off off start in manual mode. press the o key or the pf key for at least 1 s. ? 4 press the o key for at least 3 s while a-m is displayed. ( a-m will flash after 1st second.) 25.0 100.0 c a-m 25.0 100.0 c power on manual control level manual mode operation level press the o key for at least 1 s. input password. input password while amov is displayed. (set value ? 169) press the o key less than 1 s. press the o key for at least 3 s. (display will flash after 1st second.) control stops. press the o key for less than 1 s. press the o + m keys for at least 1 s. press the o + m keys for at least 3 s. (display will flash after 1st second.) protect level control in progress level change not displayed for some models control stopped start in automatic mode. adjustment level pf key ? 5 pf key ? 5 initial setting level monitor/setting item level advanced function setting level calibration level press the pf key for at least 1 s. communica- tions setting level press the o key less than 1 s. press the o key less than 1 s. press the o key for at least 1 s. pid setting level bank setting level press the o key less than 1 s. ? 3 ? 4 ? 1 ? 2 note: the time taken to move to the protect level can be adjusted by changing the ?move to protect level time? setting.
e5 @ n/e5 @ n-h 60 e5cn e5cn-u (48 x 48 mm) e5an (96 x 96 mm) e5en (48 x 96 mm) e5cn-h (48 x 48 mm) e5an-h (96 x 96 mm) e5en-h (48 x 96 mm) safety precautions operation m m m m m m m psel cwf u-no 1 bps 9.6 len 7 sbit 2 prty even sdwt 20 starting in manual mode. m m m m m m pmov 0 oapt 0 pmsk on prlp 0 icpt 1 wtpt off pfpt off m 25 m m m m m m m m m m st (self-tuning) m m m m in-t 5 in-h 100 in-l dp d-u sl-h 1300 sl-l -200 cntl onof s-hc stnd st on ptrn off cp 20 c-cp 20 orev or-r 0 0 c m m m l.adj cmwt off at off m m m m m m ct1 0.0 0.0 0.0 hb1 0.0 hb2 0.0 m m 50.0 50.0 m m oc1 50.0 oc2 50.0 m m m sp-0 0 sp-1 0 sp-2 0 sp-3 0 m m m m m m m m m m m m m m m m of-r 50.0 soak 1 c-sc 1.00 d 40 p 8.0 i 233 c-db 0.0 hys 1.0 chys 1.0 ol-l -5.0 wt-b off mv-s 0.0 mv-e 0.0 ol-h 105.0 m m m ins 0.0 insh 0.0 insl 0.0 sprt off sqrp 0.0 m m m a-m 25 25 0 m m m m m m m sp-m 0 ct1 0.0 ct2 0.0 lcr1 0.0 lcr2 0.0 prst rset sktr 0 m m-sp 0 r-s run m m m m m m m m m m m m c-o 0.0 al-1 0 al1h 0 al1l 0 al-2 0 al2h 0 al2l 0 al-3 0 al3l 0 al3h 0 o 0.0 m orl 0.0 m ct2 lcr1 hs1 lcr2 hs2 0.0 0.0 alh1 0.2 m alt1 2 m power on starting in automatic mode. manual control level pid control only pv/mv press the o key less than 1 s. press the o key less than 1 s. operation level adjustment level adjustment level display displayed only once when entering adjustment level. at execute/cancel communications writing heater current 1 value monitor heater burnout detection 1 heater overcurrent detection 1 heater current 2 value monitor heater burnout detection 2 heater overcurrent detection 2 leakage current 1 monitor leakage current 2 monitor hs alarm 1 hs alarm 2 c sp 0 sp 1 c c sp 2 sp used by multi-sp sp 3 c c c c c c c c temperature input shift 1-point shift 2-point shift set either of these parameters. upper limit temperature input shift value lower limit temperature input shift value proportional band integral time pid settings derivative time cooling coefficient heating/cooling dead band manual reset value clear the offset during stabilization of p or pd control. hysteresis (heating) hysteresis (cooling) hysteresis settings c soak time wait band mv at stop mv at pv error c sp ramp set value mv upper limit mv lower limit mv change rate limit extraction of square root low-cut point c process value added when additional pv display is on. c process value/ set point c c c auto/manual switch pid control only. added when auto/manual select addition is on. multi-sp set point setting set point during sp ramp heater current 1 value monitor heater current 2 value monitor leakage current 1 monitor leakage current 2 monitor program start soak time remain press the o and m keys for at least 3 s. protect level press the o and m keys for at least 1 s. press the o key less than 1 s. communications setting level note: the time taken to move to the protect level can be adjusted by changing the "move to protect level time" setting. note: displayed only for models with communications. changes are effective after cycling power or after a software reset. move to protect level: displayed only when a password is set. restricts moving to protect level. operation/adjustment protect: restricts displaying and modifying menus in operation, adjustment, and manual control levels. initial setting/ communications protect: this protect level restricts movement to the initial setting, communications setting, and advanced function setting levels. setting change protect: protects changes to setups by operating the front panel keys. password to move to protect level: password setting pf key protect restricts pf key operation (e5an/e5en only) parameter mask enable: displayed only when a parameter mask is set. protocol setting: switches between compoway/f (sysway) and modbus. communications unit no. communications baud rate compoway/f (sysway) only communications data length communications stop bits communications parity send data wait time c run/stop alarm value 1 set either of these parameters. alarm value upper limit 1 alarm value lower limit 1 c c c c alarm value 2 set either of these parameters. alarm value upper limit 2 alarm value lower limit 2 alarm value 3 c c c alarm value upper limit 3 alarm value lower limit 3 set either of these parameters. mv monitor (heating) mv monitor (cooling) press the o key for at least 1 s. press the o key less than 1 s. initial setting level input type scaling upper limit scaling lower limit decimal point for input type of analog c c temperature unit c, f for input type of temperature sp upper limit sp lower limit limit the set point pid on/off standard or heating/cooling for input type of temperature, standard control, or pid program pattern when assigning pid or control output to on/off output control period (heating) control period (cooling) set the on/off output cycle. direct/reverse operation c alarm 1 type alarm 1 hysteresis press the o key for at least 3 s. other than the auto/manual switch display pf key ? 2 press the pf key for at least 1 s. ? 1 pf key ? 2 press the o key or the pf key for at least 1 s. ? 1 ? 1. when the pf setting parameter is set to a-m for a controller with a pf key (e5an/e5en). ? 2. when the pf setting parameter is set to pfdp for a controller with a pf key (e5an/e5en). press the o key for at least 3 s. parameters basic type some parameters are not displayed depending on the model of the controller and parameter settings. for details, refer to the e5cn/e5an/e5en digital temperature controllers user's manual basic type (cat. no. h156).
e5 @ n/e5 @ n-h 61 e5cn e5cn-u (48 x 48 mm) e5an (96 x 96 mm) e5en (48 x 96 mm) e5cn-h (48 x 48 mm) e5an-h (96 x 96 mm) e5en-h (48 x 96 mm) operation safety precautions m m m m m m a1lt off a2lt off a3lt off prlt 3 sero off cjc on rlrv m m off colr red pv-b 5.0 m m m m m m m m m hsu on hsl off hsh 0.1 lba 0 lbal 8.0 lbab 3.0 out1 o out2 none m init off m m m m m m m m mspu off spru m rest a sb1n n-o sb2n n-o sb3n n-o hbu on hbl off hbh 0.1 m m m m ra1m 0 ra2m 0 ra2 0 ra1 0 rac 0 m m m m pf a-m pfd1 1 pfd2 0 pfd3 0 m m m m m spdp 4 odsl o pvdp on pvst off svst off m m pfd4 0 pfd5 0 m m cmov 0 inf 0.0 m m alfa 0.65 st-b 15.0 m m at-h 0.8 at-g 0.8 m lcma 20.0 m m m m m m a1on 0 a2on 0 a3on 0 a1of 0 a2of 0 a3of 0 m m m m m ocu on ocl off och 0.1 m m m m m sub1 alm1 sub2 alm2 csel on t-u m alsp sp-m m sub3 alm3 m pvrp 4 csca off m manl off m m m pvad off o-dp off ret off m istp ins1 m m mvse off amad off rt off m rt m 25 0 pf pf pf pf monitor/setting item level m m m m m alt2 2 alt3 2 tr-t off tr-h 100.0 tr-l 0.0 m o1-t 4-20 m m ev-m 1 ev-1 none ev-2 stop alh3 0.2 m alh2 0.2 m d.ref 0.25 (e5an/e5en only) c monitor/setting item display 1 note: the monitor/setting items to be displayed is set in the monitor/setting item 1 to 5 parameters (advanced function setting leve l). monitor/setting item display 2 monitor/setting item display 3 monitor/setting item display 4 monitor/setting item display 5 press the o key for at least 1 s. advanced function setting level c alarm 2 type alarm 3 type alarm 2 hysteresis alarm 3 hysteresis c transfer output type linear output transfer output upper limit transfer output lower limit linear current output linear output number of multi-sp uses two sps: 1 four sps: 2 event input assignment 1 event input assignment 2 m amov 0 m sqr off m extraction of square root enable move to advanced function setting level: displayed when initial setting/communications protect is set to 0. move by setting password ( ? 169). parameter initialization multi-sp uses sp ramp time unit standby sequence reset auxiliary output 1 open in alarm auxiliary output 2 open in alarm auxiliary output 3 open in alarm hb on/off heater burnout latch c c heater burnout hysteresis st stable range at calculated gain at hysteresis c limit cycle mv amplitude input digital filter additional pv display mv display automatic display return time alarm 1 latch alarm 2 latch alarm 3 latch move to protect level time input error output cold junction compensation method mb command logic switching pv change color pv stable band alarm 1 on delay alarm 2 on delay alarm 3 on delay alarm 1 off delay alarm 2 off delay alarm 3 off delay input shift type mv at stop and error addition auto/manual select addition hs alarm use hs alarm latch hs alarm hysteresis lba detection time c c lba level lba band control output 1 assignment control output 2 assignment auxiliary output 1 assignment auxiliary output 2 assignment auxiliary output 3 assignment (e5an/e5en only) character select soak time unit alarm sp selection manual mv limit enable pv rate of change calculation period automatic cooling coefficient adjustment heater overcurrent use heater overcurrent latch heater overcurrent hysteresis move to calibration level pf setting (e5an/e5en only) monitor/setting item 1 (e5an/e5en only) monitor/setting item 2 monitor/setting item 3 monitor/setting item 4 monitor/setting item 5 "pv/sp" display screen selection mv display selection pv decimal point display pv status display function sv status display function display refresh period control output 1 on/off count monitor control output 2 on/off count monitor control output 1 on/off count alarm set value control output 2 on/off count alarm set value on/off counter reset
e5 @ n/e5 @ n-h 62 e5cn e5cn-u (48 x 48 mm) e5an (96 x 96 mm) e5en (48 x 96 mm) e5cn-h (48 x 48 mm) e5an-h (96 x 96 mm) e5en-h (48 x 96 mm) safety precautions operation pid setting level d.pid 3 d.pid 2 d.pid 1 d.pid 8 display pid selection pid1 m m m m m m 1.oll -5.0 m m m m pid 8 proportional band m m m m m 8.p 8.0 l -5.0 8.d 40.0 h 105.0 m m m 8.ol 8.ol 1.p 8.0 1.i 233.0 1.d 40.0 1.olh 105.0 1.aut 1320.0 1.csc 1.00 1.lba 0 8.i 233.0 8.aut 1320.0 sc 1.00 8.c 8.lba 0 c c power on c c d.bnk 2 m m m m m m m m m m m m m m m m m m m m m m m m m m m m 0.lsp 0.0 0.pid 1 0.spr off 0.0 -1 0.a 1h 0.0 0.a 1l 0.0 0.a 0.0 -2 0.a 2h 0.0 0.a 2l 0.0 0.a 0.0 -3 0.a 3h 0.0 0.a 3l 0.0 0.a 1 0.sok off 0.wtb 2l 0.0 7.a 0.0 -3 7.a 3h 0.0 7.a 3l 0.0 7.a 1 7.sok off 7.wtb 7.lsp 0.0 7.pid 1 7.spr off 1h 0.0 7.a 1l 0.0 7.a 2h 0.0 7.a d.bnk 7 -1 7.a 0.0 d.bnk 2 d.bnk 1 d.bnk 0 c c c c c c c c c c c c c c c c c c c 0.0 -2 7.a c m m c c c c manual control level operation level initial setting level advanced function setting level communica- tions setting level adjustment level protect level monitor/setting item level pid setting level bank setting level bank setting level press the o key less than 1 s. press the o key less than 1 s. press the o key less than 1 s. pid2 pid3 pid8 pid 8 integral time pid 8 derivative time pid 8 mv upper limit pid 8 mv lower limit pid 8 automatic selection range upper limit pid 8 cooling coefficient pid 8 lba detection time display bank selection bank0 bank1 bank2 bank7 bank 7 sp bank 7 pid set no. bank 7 sp ramp set value bank 7 alarm value 1 bank 7 alarm value upper limit 1 bank 7 alarm value lower limit 1 set either of these parameters set either of these parameters set either of these parameters bank 7 alarm value 2 bank 7 alarm value upper limit 2 bank 7 alarm value lower limit 2 bank 7 alarm value 3 bank 7 alarm value upper limit 3 bank 7 alarm value lower limit 3 bank 7 soak time bank 7 wait band advanced type some parameters are not displayed depending on the model of the controller and parameter settings. for details, refer to the e5cn-h/e5an-h/ e5en-h digital controllers user's manual advanced type (cat. no. h157).
e5 @ n/e5 @ n-h 63 e5cn e5cn-u (48 x 48 mm) e5an (96 x 96 mm) e5en (48 x 96 mm) e5cn-h (48 x 48 mm) e5an-h (96 x 96 mm) e5en-h (48 x 96 mm) operation safety precautions 25.0 c al1l 0.0 c m m m m m m m m m m m m m m m m m m m m m m m m m 25.0 c 25.0 0.0 c a-m bank 0 rsp 0.0 sp-m 0.0 ct1 0.0 ct2 0.0 lcr1 0.0 lcr2 0.0 prst rset sktr 0 r-s run al-1 0.0 c al-2 0.0 c al2h 0.0 c al2l 0.0 c al-3 0.0 c al3h 0.0 al3l 0.0 o 0.0 c-o 0.0 v-m 0.0 al1h 0.0 c pf pf pf pf 25.0 0.0 c m m m m m m m m m m m m m m m m m m m m m m m m m m l.adj at off cmwt off irda off spmd lsp ct1 0.0 ins 0.00 c insh 0.00 c insl 0.00 c p 8.0 c i 233.0 d 40.0 c-sc 1.00 c-db 0.0 of-r 50.0 hys 1.0 chys 1.0 soak 1 wt-b off mv-s 0.0 mv-e 0.0 sprt off ol-h 105.0 ol-l -5.0 db 2.0 oc-h 0.8 sqrp 0.0 m orl m 0.0 m m m m m m m m ct2 0.0 lcr1 0.0 lcr2 0.0 hb1 0.0 hb2 0.0 hs1 50.0 hs2 50.0 oc1 50.0 oc2 50.0 m 100.0 starting in manual mode. power on starting in automatic mode. manual control level pid control only pv/mv press the o key less than 1 s. operation level adjustment level adjustment level display displayed only once when entering adjustment level. at execute/cancel communications writing heater current 1 value monitor heater burnout detection 1 heater overcurrent detection 1 heater current 2 value monitor heater burnout detection 2 heater overcurrent detection 2 leakage current 1 monitor leakage current 2 monitor hs alarm 1 hs alarm 2 temperature input shift 1-point shift 2-point shift upper limit temperature input shift value lower limit temperature input shift value proportional band integral time pid settings derivative time cooling coefficient heating/cooling dead band manual reset value clear the offset during stabilization of p or pd control. hysteresis (heating) hysteresis (cooling) hysteresis settings soak time wait band mv at stop mv at pv error sp ramp set value mv upper limit mv lower limit mv change rate limit process value added when additional pv display is on. process value/ set point auto/manual switch pid control only. added when auto/manual select addition is on. set point during sp ramp heater current 1 value monitor heater current 2 value monitor leakage current 1 monitor leakage current 2 monitor program start soak time remain press the o and m keys for at least 3 s. run/stop alarm value 1 set either of these parameters. alarm value upper limit 1 alarm value lower limit 1 alarm value 2 set either of these parameters. alarm value upper limit 2 alarm value lower limit 2 alarm value 3 alarm value upper limit 3 alarm value lower limit 3 set either of these parameters. mv monitor (heating) mv monitor (cooling) press the pf key for at least 1 s. press the o key or the pf key for at least 1 s. ? 1 press the o key for at least 3 s. set either of these param- eters. extraction of square root low-cut point press the o and m keys for at least 1 s. pf key ? 2 pf key ? 2 monitor/setting item level (e5an-h/e5en-h only) monitor/setting item display 1 monitor/setting item display 2 monitor/setting item display 3 monitor/setting item display 4 monitor/setting item display 5 note: the monitor/setting items to be displayed is set in the monitor/setting item 1 to 5 parameters (advanced function setting level). infrared communications use sp mode position proportional dead band open/close hysteresis bank no. remote sp monitor valve opening monitor ? 1 ? 1. when the pf setting parameter is set to a-m for a controller with a pf key (e5an-h/e5en-h). ? 2. when the pf setting parameter is set to pfdp for a controller with a pf key (e5an-h/e5en-h).
e5 @ n/e5 @ n-h 64 e5cn e5cn-u (48 x 48 mm) e5an (96 x 96 mm) e5en (48 x 96 mm) e5cn-h (48 x 48 mm) e5an-h (96 x 96 mm) e5en-h (48 x 96 mm) safety precautions operation m m m m m m m pmov 0 oapt 0 icpt 0 wtpt off pfpt off pmsk on prlp 0 m m m m m m m psel cwf u-no 1 bps 9.6 len 7 sbit 2 prty even sdwt 20 m m m m m m m m m m m m m m m m m m m m m m m m in-t 5 in-h 100 in-l 0 dp 0 d-u c sl-h 1300.0 c sl-l -200.0 c cntl pid s-hc stnd st on ptrn off cp 20 c-cp 20 alt1 2 alt2 2 alt3 2 tr-t off tr-h 100.0 tr-l 0.0 o1-t 4-20 clfl flot calb off mot 30 off sqr amov 0 m m pbnk 7 m alh1 0.2 c m alh2 0.2 c m alh3 0.2 c m m m m ev-1 none ev-2 stop ev-3 none ev-4 none m ev-b 1 m orev or-r st (self-tuning) protect level communications setting level the time taken to move to the protect level can be adjusted by changing the "move to protect level time" setting. displayed only for models with communications. changes are effective after cycling power or after a software reset. move to protect level: displayed only when a password is set. restricts moving to protect level. operation/adjustment protect: restricts displaying and modifying menus in operation, adjustment, and manual control levels. initial setting/ communications protect: this protect level restricts movement to the initial setting, communications setting, and advanced function setting levels. setting change protect: protects changes to setups by operating the front panel keys. password to move to protect level: password setting pf key protect restricts pf key operation (e5an-h/e5en-h only) parameter mask enable: displayed only when a parameter mask is set. protocol setting: switches between compoway/f (sysway) and modbus. communications unit no. communications baud rate compoway/f (sysway) only communications data length communications stop bits communications parity send data wait time press the o key for at least 1 s. press the o key less than 1 s. initial setting level input type scaling upper limit scaling lower limit decimal point for input type of analog temperature unit c, f for input type of temperature sp upper limit sp lower limit limit the set point pid on/off standard or heating/cooling for input type of temperature, standard control, or pid program pattern when assigning pid or control output to on/off output control period (heating) control period (cooling) set the on/off output cycle. direct/reverse operation alarm 1 type alarm 1 hysteresis press the o key for at least 3 s. other than the auto/manual switch display press the o key less than 1 s. alarm 2 type alarm 3 type alarm 2 hysteresis alarm 3 hysteresis transfer output type linear output transfer output upper limit transfer output lower limit linear current output linear output bank numbers used event input assignment 1 event input assignment 2 event input assignment 3 event input assignment 4 extraction of square root enable move to advanced function setting level: displayed when initial setting/ communications protect is set to 0. move by setting password ( ? 169). valid program bank closed/floating motor calibration travel time
e5 @ n/e5 @ n-h 65 e5cn e5cn-u (48 x 48 mm) e5an (96 x 96 mm) e5en (48 x 96 mm) e5cn-h (48 x 48 mm) e5an-h (96 x 96 mm) e5en-h (48 x 96 mm) operation safety precautions m m m m m m m m m m m m m m m m m init off m m m m m m m spru m rest a sb1n n-o sb2n n-o sb3n n-o hbh 0.1 hbu on hbl off m a3lt ret o-dp m m m m m m m m m m m m m m off off off m m m st-b 15.0 c alfa 0.65 at-g at-h lcma 20.0 inf 0.0 pvad off a1lt off a2lt off prlt 3 sero off colr red rlrv off pv-b 5.0 c m cjc on m m m m m m m m m m m m istp ins1 mvse off amad on rt off hsu on hsl off hsh 0.1 lba 0 lbab 3.0 c out1 o out2 none 8.0 c lbal p-db 0.0 m m m m m m m m m m m m m rspu off rsph 1300.0 rspl -200.0 sptr off rseo off pidh 0.50 manl off pmvd off pvrp 17 csca off pidi pv pfd1 1 pfd2 0 pfd3 0 pfd4 0 pfd5 0 spdp 4 odsl o pvdp on pvst off svst off ra1m 0 ra2m 0 ra1 0 ra2 0 rac 0 cmov 0 c c c c m m m m m 0 a1on 0 a2on 0 a3on 0 a1of a2of 0 a3of 0 m m m m sub1 alm1 sub2 alm2 csel on t-u m sub3 alm3 m m ocl off ocu on och 0.1 m pf a-m 0.8 1.0 m alsp sp-m m m m d.ref 0.25 0 rt press the o key for at least 1 s. advanced function setting level parameter initialization sp ramp time unit standby sequence reset auxiliary output 1 open in alarm auxiliary output 2 open in alarm auxiliary output 3 open in alarm hb on/off heater burnout latch heater burnout hysteresis st stable range at calculated gain at hysteresis limit cycle mv amplitude input digital filter additional pv display mv display automatic display return time alarm 1 latch alarm 2 latch alarm 3 latch move to protect level time input error output cold junction compensation method mb command logic switching pv change color pv stable band alarm 1 on delay alarm 2 on delay alarm 3 on delay alarm 1 off delay alarm 2 off delay alarm 3 off delay input shift type mv at stop and error addition auto/manual select addition hs alarm use hs alarm latch hs alarm hysteresis lba detection time lba level lba band control output 1 assignment control output 2 assignment auxiliary output 1 assignment auxiliary output 2 assignment auxiliary output 3 assignment (e5an/e5en-h only) character select soak time unit alarm sp selection manual mv limit enable pv rate of change calculation period automatic cooling coefficient adjustment heater overcurrent use heater overcurrent latch heater overcurrent hysteresis move to calibration level pf setting monitor/setting item 1 monitor/setting item 2 monitor/setting item 3 monitor/setting item 4 monitor/setting item 5 "pv/sp" display screen selection mv display selection pv decimal point display pv status display function sv status display function display refresh period control output 1 on/off count monitor control output 2 on/off count monitor control output 1 on/off count alarm set value control output 2 on/off count alarm set value on/off counter reset power on manual control level operation level initial setting level adjustment level protect level monitor/setting item level pid setting level bank setting level remote sp enable remote sp upper limit remote sp lower limit sp tracking remote sp input error output pid set automatic selection data pid set automatic selection hysteresis pv dead band direct setting of position proportional mv advanced function setting level communica- tions setting level
e5 @ n/e5 @ n-h 66 e5cn e5cn-u (48 x 48 mm) e5an (96 x 96 mm) e5en (48 x 96 mm) e5cn-h (48 x 48 mm) e5an-h (96 x 96 mm) e5en-h (48 x 96 mm) safety precautions operation safety precautions ! caution ? 1. an selv circuit is one separa ted from the power supply with double insulation or reinforced in sulation, that does not exceed 30 v r.m.s. and 42.4 v peak or 60 vdc. ? 2. a class 2 power supply is one test ed and certified by ul as having the current and voltage of the secondary output restricted to specific levels. ? 3. the tightening torque for e5cn-u is 0.5 nm. precautions for safe use be sure to observe the following precautions to prevent malfunction or adverse affects on the performance or functionality of the product. not doing so may occasionally result in faulty operation. 1. this product is specifically designed for indoor use only. do not use this product in the following places: ? places directly subject to hea t radiated from heating equipment. ? places subject to splashi ng liquid or oil atmosphere. ? places subject to direct sunlight. ? places subject to dust or corrosive gas (in par ticular, sulfide gas and ammonia gas). ? places subject to in tense temperature change. ? places subject to ic ing and condensation. ? places subject to vibr ation and large shocks. 2. use and store the product within the rated ambient temperature and humidity. gang-mounting two or more temper ature controllers, or mounting temperature controllers above each other may cause heat to build up inside the temperature controll ers, which will shorten their service life. in such a case, use forced cooling by fans or other means of air ventilation to cool down the temperature controllers. 3. to allow heat to escape, do not block the area around the product. do not block the ventilation holes on the product. 4. be sure to wire properly with correct polarity of terminals. 5. use the specified size (m3.5, width 7.2 mm or less) crimped terminals for wiring. to connect bar e wires to the terminal block, use stranded or solid copper wires with a gage of awg24 to awg14 (equal to a cross-sectional area of 0.205 to 2.081 mm 2 ). (the stripping length is 5 to 6 mm.) up to two wires of the same size and type or two crimp termi nals can be inserted into a single terminal. 6. do not wire the terminals that are not used. 7. to avoid inductive noise, keep the wiring for the product?s terminal block away from power cables carry high voltages or large currents. also, do not wire power lines together with or parallel to product wiring. using shielded ca bles and using separate conduits or ducts is recommended. attach a surge suppressor or noise filter to peripheral devices that generate noise (in particular, moto rs, transformers, solenoids, magnetic coils, or other equipment that have an inductance component). when a noise filter is used at the power supply, first check the voltage or current, and attach the noi se filter as cl ose as possible to the product. allow as much space as possi ble between the product and devices that generate powerful high frequencies (high-frequency welders, high-frequency sewing machines, etc.) or surge. 8. use this product within the rated load and power supply. 9. make sure that the rated voltage is attained within two seconds of turning on the power using a switch or relay contact. if the voltage is applied gradually, the power may not be reset or output malfunctions may occur. 10. make sure that the temperatur e controller has 30 minutes or more to warm up after turning on the power before starting actual control operations to ensure t he correct temperature display. do not touch the terminals while power is being supplied. doing so may occasionally re sult in minor injury due to electric shock. do not allow pieces of meta l, wire clippings, or fine metallic shavings or filings from installation to enter the product. doing so may occasi onally result in electric shock, fire, or malfunction. do not use the product wher e subject to flammable or explosive gas. otherwise, minor injury from explosion may occasionally occur. do not leave the cable for the support software connected to the product. malfunction may occur due to noise in the cable. do not use the temperature controller or conversion cable if it is damaged. doing so may occasionally result in minor electric shock or fire. never disassemble, modify, or repair the product or touch any of the internal parts. minor electric shock, fire, or malfunction may occasionally occur. caution - risk of fire and electric shock a) this product is ul li sted as open type process control equipment. it must be mounted in an enclosure that does not allow fire to escape externally. b) more than one disconnect switch may be required to de-energize the equipment before servicing the product. c) signal inputs are selv, limited energy. ? 1 d) caution: to reduce the risk of fire or electric shock, do not interconnect the outputs of different class 2 circuits. ? 2 if the output relays are used past their life expectancy, contact fusing or burning may occasionally occur. always consider the applic ation conditions and use the output relays within their rated load and electrical life expectancy. the life expectanc y of output relays varies considerably with the output load and switching conditions. tighten the terminal screws to between 0.74 and 0.90 nm. ? 3 loose screws may occa sionally result in fire. set the parameters of the product so that they are suitable for the system being controlled. if they are not suitable, unexpected operation may occasionally result in property damage or accidents. a malfunction in the product may occasionally make control operations impossible or prevent alarm outputs, resulting in property damage. to maintain safety in the event of malfunction of the product, take appropriate safety measures, such as installing a monitoring device on a separate line. a semiconductor is used in the output section of long-life relays. if excessive noise or surge is impressed on the output terminals, a short-circuit failure is likely to occur. if the output remains shorted, fire will occur due to overheating of the heater or other cause. take measures in the overall system to prevent excessive temperature increase and to prevent fire from spreading. do not allow pieces of metal or wire cuttings to get inside the cable connector for the support software. failure to do so may occasionally result in minor electric shock, fire, or damage to equipment. do not allow dust and dirt to collect between the pins in the connector on the conversion cable. failure to do so may occasionally result in fire. when inserting the body of the temperature controller into the case, confirm that the hooks on the top and bottom are securely engaged with the case. if the body of the temperature controller is not inserted properly, faulty contact in the terminal section or reduced water resistance may occasionally result in fire or malfunction. when connecting the control output unit to the socket, press it in until there is no gap between the control output unit and the socket. otherwise contact faults in the connector pins may occasionally result in fire or malfunction.
e5 @ n/e5 @ n-h 67 e5cn e5cn-u (48 x 48 mm) e5an (96 x 96 mm) e5en (48 x 96 mm) e5cn-h (48 x 48 mm) e5an-h (96 x 96 mm) e5en-h (48 x 96 mm) operation safety precautions 11. when executing self-tuning, turn on power to the load (e.g., heater) at the same time as or before supplying power to the product. if power is turned on to the product before turning on power to the load, self-tuning wi ll not be performed properly and optimum control will not be achieved. 12. a switch or circuit breaker must be provided close to the product. the switch or circui t breaker must be within easy reach of the operator, and must be marked as a disconnecting means for this unit. 13. always turn off the power supply be fore pulling out the interior of the product, and never touch nor apply shock to t he terminals or electronic components. when insert ing the interior of the product, do not allow the electronic components to touch the case. 14. do not use paint thinner or simi lar chemical to clean with. use standard grade alcohol. 15. design the system (e.g., contro l panel) considering the 2 seconds of delay that the product's output to be set after power on. 16. the output may turn off when shifting to certain levels. take this into consideration when performing control. 17. the number of eeprom write operatio ns is limited. therefore, use ram write mode when frequently overwriting data during communications or other operations. 18. always touch a grounded piece of metal before touching the temperature controller to discharge static electricity from your body. 19. do not remove the terminal block. doing so may result in failure or malfunction. 20. control outputs (for driving ssr) that are voltage outputs are not isolated from the internal circuits. when using a grounded thermocouple, do not connect any of the control output terminals to ground. (doing so may result in an unwanted circuit path, causing error in the measured temperature.) 21. when replacing the body of the temperature controller, check the condition of the terminals. if co rroded terminals are used, contact failure in the terminals may cause the temperature inside the temperature controller to increase, possibly resulting in fire. if the terminals are corroded, r eplace the case as well. 22. use suitable tools when taking the temperature controller apart for disposal. sharp par ts inside the temperature controller may cause injury. 23. before connecting an output uni t, confirm the specifications and thoroughly read relevant information in the datasheet and manual for the temperature controller. 24. check the orientation of the connectors on the conversion cable before connecting the conversion cable. do not force a connector if it does not connect smoothly. using excessive force may damage the connector. 25. do not place heavy object on t he conversion cable, bend the cable past its natural bending radi us, or pull on the cable with undue force. 26. do not connect or disconnect the conversion cable while communications are in progress. product faults or malfunction may occur. 27. make sure that the conversion cable's metal components are not touching the external power terminals. 28. do not touch the connectors on the conversion cable with wet hands. electrical shock may result. 29. before using infrared communications, correctly attach the enclosed mounting adapter to the cable for the support software. when connecting the infrared port on the cable to the support software into the adapter, insert the connector to the specified line. communications may not be po ssible if the connector is not connected properly. precautions for correct use service life 1. use the product within the following temperature and humidity ranges: temperature: ? 10 to 55 c (with no icing or condensation) humidity: 25% to 85% if the product is installed inside a control board, the ambient temperature must be kept to under 55 c, including the temperature around the product. 2. the service life of el ectronic devices like temperature controllers is determined not only by the number of times the relay is switched but also by the service life of internal electronic components. component service life is affected by the ambient temperature: the higher the temperature, the shorter the service life and, the lower the temperature, the longer the serv ice life. therefore, the service life can be extended by lowering the temperature of the temperature controller. 3. when two or more temperature controllers are mounted horizontally close to each other or vertically next to one another, the internal temperature will in crease due to heat radiated by the temperature controllers and the service life will decrease. in such a case, use forced cooling by fans or other means of air ventilation to cool down the temperature c ontrollers. when providing forced cooling, however, be careful not to cool down the terminals sections alone to avoid measurement errors. measurement accuracy 1. when extending or connecting the thermocouple lead wire, be sure to use compensating wires that match the thermocouple types. 2. when extending or connecting the lead wire of the platinum resistance thermometer, be sure to use wires that have low resistance and keep the resistance of the three lead wires the same. 3. mount the product so that it is horizontally level. 4. if the measurement accuracy is low, check to see if input shift has been set correctly. waterproofing the degree of protection is as s hown below. sections without any specification on their degree of protection or those with ip @ 0 are not waterproof. front panel: ip66 rear case: ip20, terminal section: ip00 (e5cn-u: front panel: ip50, rear case: ip20, terminals: ip00) operating precautions 1. it takes approximately two seconds for the outputs to turn on from after the power supply is turned on. due consideration must be given to this time when incorporat ing temperature controllers in a sequence circuit. 2. when using self-tuning, turn on power for the load (e.g., heater) at the same time as or before supplying power to the temperature controller. if power is turned on for the temperature controller before turning on power for the load, self-tuning will not be performed properly and optimum control will not be achieved. 3. when starting operation after the temperature controller has warmed up, turn off the power and then turn it on again at the same time as turning on power for the load. (instead of turning the temperature controller off and on again, switching from stop mode to run mode can also be used.) 4. avoid using the controller in places near a radio, television set, or wireless installing. these devi ces can cause radio disturbances which adversely affect the performance of the controller. others 1. the disk that is included with the conversion cable is designed for a computer cd-rom driver. never a ttempt to play the disk in a general-purpose audio player. 2. do not connect or disconnect t he conversion cable connector repeatedly over a shor t period of time. the computer may malfunction. 3. after connecting the conversion c able to the computer, check the com port number before starting communications. the computer requires time to recognize the cable connection. this delay does not indicate failure. 4. do not connect the conversion cable through a usb hub. doing so may damage the conversion cable. 5. do not use an extension cable to extend the conversion cable length when connecting to the computer. doing so may damage the conversion cable. 6. the e5an-h/e5en-h use the same port for communications through the infrared port and the support software port. do not attempt to use communications through the support software port when the infrared port is being used.
e5 @ n/e5 @ n-h 68 e5cn e5cn-u (48 x 48 mm) e5an (96 x 96 mm) e5en (48 x 96 mm) e5cn-h (48 x 48 mm) e5an-h (96 x 96 mm) e5en-h (48 x 96 mm) safety precautions operation mounting mounting to a panel for waterproof mounting, waterproof packing must be installed on the controller. waterproofing is not possible when group mounting several controllers. waterproof packing is not necessary when there is no need for the waterproofing function. e5cn 1. the panel mounting adapter is also included with the e5cn-u. there is no waterproof packing included with the e5cn-u. 2. insert the e5cn/e5cn-u into the mounting hole in the panel. 3. push the adapter from the terminals up to the panel, and temporarily fasten the e5cn/e5cn-u. 4. tighten the two fastening screws on the adapter. alternately tighten the two screws li ttle by little to maintain a balance. tighten the screws to a torque of 0.29 to 0.39 nm. e5en/e5an 1. insert the e5an/e5en into the square mounting hole in the panel (thickness: 1 to 8 mm). attach t he mounting brackets provided with the product to the mounting grooves on the top and bottom surfaces of the rear case. 2. use a ratchet to alternately tighten the screws on the top and bottom mounting brackets little by little to maintain balance, until the ratchet turns freely. mounting the terminal cover e5cn make sure that the ?up? mark is facing up, and then attach the e53- cov17 terminal cover to the holes on the top and bottom of the temperature controller. e5an/e5en slightly bend the e53-cov16 terminal cover to attach it to the terminal block as shown in the fo llowing diagram. the terminal cover cannot be attached in the opposite direction. removing the temperature controller from the case the temperature controller can be re moved from the case to perform maintenance without removing the term inal leads. this is possible for only the e5cn, e5an, and e5en, and not for the e5cn-u. check the specifications of the case an d temperature controller before removing the temperature controller from the case. e5cn 1. insert a flat-blade screwdriver into the two tool insertion holes (one on the top and one on the bottom) to release the hooks. 2. insert the flat-blade screwdriver in the gap between the front panel and rear case, and pull out the fron t panel slightly. hold the top and bottom of the front panel and carefully pull it out toward you, without applying unnecessary force. 3. when inserting the body of the temperature controller into the case, make sure the pcbs are parallel to each other, make sure that the sealing rubber is in place, and press the e5cn toward the rear case into position. while pushing the e5cn into place, push down on the hooks on the top and bottom surfaces of the rear case so that the hooks are securely locked in place. be sure that electronic components do not come into contact with the case. e53-cov17 terminal cover (accessory) adapter (accessory) e5cn e5cn-u waterproof packing (accessory) panel order the p2cf-11 or p3ga-11 socket separately. for front-mounting socket (panel mounting is also possible.) mounting bracket (accessory) mounting bracket (accessory) panel panel waterproof packing (accessory) waterproof packing (accessory) e53-cov16 terminal cover (accessory) e5en e5an e53-cov16 terminal cover (accessory) slightly bend the e53-cov16 terminal cover in the direction shown by the arrows to attach it to the terminal block. e53-cov16 terminal cover (accessory) 2.0 0.4 (1) (2) (3) (1) flat-blade screwdriver (unit: mm) tool insertion hole
e5 @ n/e5 @ n-h 69 e5cn e5cn-u (48 x 48 mm) e5an (96 x 96 mm) e5en (48 x 96 mm) e5cn-h (48 x 48 mm) e5an-h (96 x 96 mm) e5en-h (48 x 96 mm) operation safety precautions e5an/e5en 1. insert a flat-blade screwdriver into the two tool insertion holes (one on the top and one on the bottom) to release the hooks. 2. insert the flat-blade screwdriver in the gap between the front panel and rear case (two on the top and two on the bottom), and use it to pry and pull out the front panel slightly. then, pull out on the front panel gripping both sides. be sure not to impose excessive force on the panel. 3. when inserting the body of the temperature controller into the case, make sure the pcbs are parallel to each other, make sure that the sealing rubber is in place, and press the e5an/e5en toward the rear case until it snap s into position. while pressing the e5an/e5en into place, press down on the hooks on the top and bottom surfaces of the rear case so that the hooks securely lock in place. make sure that electronic components do not come into contact with the case. precautions when wiring ? separate input leads and power lines in order to prevent external noise. ? use wires with a gage of awg24 (cross-sectional area: 0.205 mm 2 ) to awg14 (cross-sectional area: 2.081 mm 2 ) twisted- pair cable (stripping length: 5 to 6 mm). ? use crimp terminals when wiring the terminals. ? tighten the terminal screws to a torque of 0.74 to 0.90 nm, however the terminal screws on the e5cn-u must be tightened to a torque of 0.5 nm. ? use the following types of crim p terminals for m3.5 screws. ? do not remove the terminal block. doing so will result in malfunction or failure. (1) (1) (2) (3) (1) (1) (2) (3) tool insertion hole tool insertion hole e5an e5en 7.2 mm max. 7.2 mm max.
70 cx-thermo support software ver. 4.0 est2-2c-mv4 monitoring/setting support soft ware for e5cn/cn-h, e5an/an-h, e5en/en-h, e5zn, e5 @ r/ @ r-t, and ej1 temper ature controllers enabling faster parameter setu p, device adjustment, and maintenance ? enables editing and batch-downloading parameters from a personal computer, reducing the work required to set parameters. usability is improved with table-formatted parameter editing from version. 4.0. ? supports trend monitoring: monitor data (pv,sp,mv,pid parame ter, alarm on/off, etc.) for up to 31 e5 @ n/ @ n-h temperature controllers. connect up to 64 ej1n, 17 ej1g, or 16 e5zn temperature controllers. (the temperature cont rollers must be from the same series.) ? supports parameter masks to hide parameters unnecessary to display. (supported only by the e5 @ n/ @ n-h and e5 @ r/ @ r-t). ? logic operations enable setting inpu ts from external inputs (event inputs) or temperature status, outputs to external outputs (control or auxiliary outputs), and changing operating status with on/off delays. (supported only by the e5 @ n/ @ n-h). ? easy adjustment of control performance by fine-tuning. ? fine-tuning instructs the cx-thermo to calculate a pid parameters by directly inputting commands to improve response. ordering information list of models specifications name model cx-thermo support software est2-2c-mv4 compatible devices temperature controllers e5cn (available from april 2004) e5an, e5en (available from feb 2005), e5cn-h, e5an-h, e5en-h e5ar, e5er e5ar-t, e5er-t e5zn ej1n-tc4, ej1n-tc2, ej1n-hfu ej1g-tc4, ej1g-tc2, ej1g-hfu g3za (only when connected to ej1n-tc4, ej1n-tc2, ej1g-tc4, ej1g-tc2) note: models with devicenet communications are not supported. personal computer system requirements os windows 2000 (service pack 3 or higher), xp, or vista (japanese or english version) cpu 300 mhz min. memory 128 mb min. harddisk 300 mb min. available space cd-rom one cd-rom drive min. monitor svga (800 600) min. communications ports ? rs-232c port, or usb port, 1 port min. connection method ? an e58-cifq1 usb-serial conversion cable is required to connect a com puter to the setup tool port the e5 @ n, e5 @ n-h, or ej1. ? a k3sc interface converter is used to connec t a computer to models with rs-422/rs-485 communications. ? an e58-cifir usb-infrared conversion cable is required to wirelessly connect a computer to models with infrared communications (e5an-h or e5en-h).
71
warranty and application considerations read and understand this catalog please read and understand this catalog before purchasing the products. please consult your omron representative if you have any questions or comments. warranty and limitations of liability warranty omron's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by omron. omron makes no warranty or representation, expr ess or implied, regarding non-infringement, merchantability, or fitness for particular purpose of the products. any buyer or user acknowledges that the buyer or user alone has determined that the products will suitably meet the requirements of their intended use. omron disclaims all other warranties, express or implied. limitations of liability omron shall not be responsible for special, indirect , or consequential damages, loss of profits, or commercial loss in any way connected with the products, whether such claim is based on contract, warranty, neglige nce, or strict liability. in no event shall the resp onsibility of omron for any act e xceed the individual pr ice of the product on which liability is asse rted. in no event shall omron be responsible for warra nty, repair, or other claims regarding the products unless omron's analysis confirms that the products were properly handled, stored, installed, and maintained and not subject to contamination, abuse, misuse, or inappropriate modification or repair. application considerations suitability for use omron shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's application or use of the products. take all necessary steps to determine th e suitability of the product for the systems, machines, and equipment with which it wil l be used. know and observe all prohibitions of use applicable to this product. never use the products for an application involv ing serious risk to life or property without ensuring that the system as a whole has been designed to address the risks, and that the omron products are properly rated and installed for th e intended use within the overall equipment or system. disclaimers performance data performance data given in this catalog is provided as a guide fo r the user in determining suitability and does not constitute a warranty. it may represent the result of omron's test conditions, and the users mu st correlate it to actual application requirements. actual performance is subject to the omron warranty and limitations of liability. change in specifications product specifications and accessories may be changed at any time based on improvements and other reasons. consult with your omron representative at any time to conf irm actual specifications of purchased product. dimensions and weights dimensions and weights are nominal and are not to be used fo r manufacturing purposes, even when tolerances are shown. in the interest of product impr ovement, specifications are subj ect to change without notice. all dimensions shown are in millimeters. to convert millimeters into inches, multiply by 0.03937. to convert grams into ounces, multiply by 0.03527. cat. no. h160-e1-01a omron corporation industrial automation company control devices division h.q. analog controller division shiokoji horikawa, shimogyo-ku, kyoto, 600-8530 japan tel: (81)75-344-7080/fax: (81)75-344-7149 0208 (1207)


▲Up To Search▲   

 
Price & Availability of E5CN-CMT-500

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X