  data sheet. types n0606ys200 to n0606ys250 issue 2 page 1 of 11 october, 2004 westcode an ixys company date:- 18 oct, 2004 data sheet issue:- 2 phase control thyristor types n0606ys200 to n0606ys250 old type no.: n282sh20-22 absolute maximum ratings voltage ratings maximum limits units v drm repetitive peak off-state voltage, (note 1) 2000-2500 v v dsm non-repetitive peak off-state voltage, (note 1) 2000-2500 v v rrm repetitive peak reverse voltage, (note 1) 2000-2500 v v rsm non-repetitive peak reverse voltage, (note 1) 2100-2600 v other ratings maximum limits units i t(av)m maximum average on-state current, t sink =55c, (note 2) 606 a i t(av)m maximum average on-state current. t sink =85c, (note 2) 415 a i t(av)m maximum average on-state current. t sink =85c, (note 3) 250 a i t(rms)m nominal rms on-state current, t sink =25c, (note 2) 1199 a i t(d.c.) d.c. on-state current, t sink =25c, (note 4) 1034 a i tsm peak non-repetitive surge t p =10ms, v rm =60%v rrm , (note 5) 7100 a i tsm2 peak non-repetitive surge t p =10ms, v rm 10v, (note 5) 7800 a i 2 ti 2 t capacity for fusing t p =10ms, v rm =60%v rrm , (note 5) 25210 3 a 2 s i 2 t i 2 t capacity for fusing t p =10ms, v rm 10v, (note 5) 30510 3 a 2 s critical rate of rise of on-state current (repetitive), (note 6) 300 a/s (di/dt) cr critical rate of rise of on-state current (non-repetitive), (note 6) 600 a/s v rgm peak reverse gate voltage 5 v p g(av) mean forward gate power 2 w p gm peak forward gate power 30 w t j op operating temperature range -40 to +125 c t stg storage temperature range -40 to +150 c notes:- 1) de-rating factor of 0.13% per c is applicable for t j below 25c. 2) double side cooled, single phase; 50hz, 180 half-sinewave. 3) single side cooled, single phase; 50hz, 180 half-sinewave. 4) double side cooled. 5) half-sinewave, 125c t j initial. 6) v d =67% v drm , i fg =2a, t r 0.5s, t case =125c.
westcode westcode westcode westcode an ixys company phase control thyristor types n0606ys200 to n0606ys250 data sheet. types n0606ys200 to n0606ys250 issue 2 page 2 of 11 october, 2004 characteristics parameter min. typ. max. test conditions (note 1) units v tm maximum peak on-state voltage - - 2.35 i tm =1550a v v tm maximum peak on-state voltage - - 2.55 i tm =1800a v v t0 threshold voltage - - 1.103 v r t slope resistance - - 0.804 m ? (dv/dt) cr critical rate of rise of off-state voltage 1000 - - v d =80% v drm , linear ramp, gate o/c v/ s i drm peak off-state current - - 40 rated v drm ma i rrm peak reverse current - - 40 rated v rrm ma v gt gate trigger voltage - - 3.0 v i gt gate trigger current - - 200 t j =25c v d =10v, i t =3a ma v gd gate non-trigger voltage - - 0.25 rated v drm v i h holding current - - 500 t j =25c ma t gd gate-controlled turn-on delay time 0.5 1 s t gt turn-on time - 1.5 2 v d =67% v drm , i t =550a, di/dt=40a/s, i fg =2a, t r =0.5s, t j =25c s q rr recovered charge - 2000 - c q ra recovered charge, 50% chord - 800 1000 c i rr reverse recovery current - 180 - a t rr reverse recovery time - 9 - i tm =550a, t p =500s, di/dt=40a/s, v r =50v s - 300 - i tm =500a, t p =500s, di/dt=40a/s, v r =50v, v dr =80%v drm , dv dr /dt=20v/s t q turn-off time - 450 - i tm =500a, t p =500s, di/dt=40a/s, v r =50v, v dr =80%v drm , dv dr /dt=200v/s s - - 0.05 double side cooled k/w r thjk thermal resistance, junction to heatsink - - 0.1 single side cooled k/w f mounting force 5 - 9 kn w t weight - 90 - g notes:- 1) unless otherwise indicated t j =125 c.
westcode westcode westcode westcode an ixys company phase control thyristor types n0606ys200 to n0606ys250 data sheet. types n0606ys200 to n0606ys250 issue 2 page 3 of 11 october, 2004 notes on ratings and characteristics 1.0 voltage grade table voltage grade v drm v dsm v rrm v v rsm v v d v r dc v 20 2000 2100 1250 22 2200 2300 1350 24 2400 2500 1450 25 2500 2600 1500 2.0 extension of voltage grades this report is applicable to other voltage grades when supply has been agreed by sales/production. 3.0 de-rating factor a blocking voltage de-rating factor of 0.13%/c is applicable to this device for t j below 25c. 4.0 repetitive dv/dt standard dv/dt is 1000v/s. 5.0 snubber components when selecting snubber components, care must be taken not to use excessively large values of snubber capacitor or excessively small values of snubber resistor. such excessive component values may lead to device damage due to the large resultant values of snubber discharge current. if required, please consult the factory for assistance. 6.0 rate of rise of on-state current the maximum un-primed rate of rise of on-state current must not exceed 300a/s at any time during turn- on on a non-repetitive basis. for repetitive performance, the on-state rate of rise of current must not exceed 150a/s at any time during turn-on. note that these values of rate of rise of current apply to the total device current including that from any local snubber network. 7.0 gate drive the nominal requirement for a typical gate drive is illustrated below. an open circuit voltage of at least 30v is assumed. this gate drive must be applied when using the full di/dt capability of the device. i gm i g t p1 4a/s the magnitude of i gm should be between five and ten times i gt , which is shown on page 2. its duration (t p1 ) should be 20s or sufficient to allow the anode current to reach ten times i l , whichever is greater. otherwise, an increase in pulse current could be needed to supply the necessary charge to trigger. the ?back-porch? current i g should remain flowing for the same duration as the anode current and have a magnitude in the order of 1.5 times i gt .
westcode westcode westcode westcode an ixys company phase control thyristor types n0606ys200 to n0606ys250 data sheet. types n0606ys200 to n0606ys250 issue 2 page 4 of 11 october, 2004 8.0 computer modelling parameters 8.1 device dissipation calculations t av t t t av r ff w r ff v v i ? ? ? ? ? + + ? = 2 2 2 0 0 2 4 and: k j th av t t t r t w ? = ? ? = max where v t0 =1.103v, r t =0.804m ?, r th = supplementary thermal impedance, see table below and ff = form factor, see table below. supplementary thermal impedance conduction angle 30 60 90 120 180 270 d.c. square wave double side cooled 0.071 0.069 0.065 0.061 0.057 0.053 0.05 square wave single side cooled 0.12 0.119 0.115 0.111 0.107 0.103 0.1 sine wave double side cooled 0.053 0.052 0.0516 0.0513 0.0505 sine wave single side cooled 0.103 0.102 0.1017 0.1013 0.1005 form factors conduction angle 30 60 90 120 180 270 d.c. square wave 3.46 2.45 2 1.73 1.41 1.15 1 sine wave 3.98 2.78 2.22 1.88 1.57 8.2 calculating v t using abcd coefficients the on-state characteristic i t vs. v t , on page 6 is represented in two ways; (i) the well established v t0 and r t tangent used for rating purposes and (ii) a set of constants a, b, c, d, forming the coefficients of the representative equation for v t in terms of i t given below: () t t t t i d i c i b a v ? + ? + ? + = ln the constants, derived by curve fitting software, are given below for both hot and cold characteristics. the resulting values for v t agree with the true device characteristic over a current range, which is limited to that plotted. 25c coefficients 125c coefficients a 0.6344325 a -0.1326695 b 0.1054622 b 0.2813411 c 5.6730610 -4 c 9.3940910 -4 d -3.75299310 -3 d -0.02641982
westcode westcode westcode westcode an ixys company phase control thyristor types n0606ys200 to n0606ys250 data sheet. types n0606ys200 to n0606ys250 issue 2 page 5 of 11 october, 2004 8.3 d.c. thermal impedance calculation = = ? ? ? ? ? ? ? ? ? ? ? = n p p t p t p e r r 1 1 where p = 1 to n, n is the number of terms in the series and: t = duration of heating pulse in seconds. r t = thermal resistance at time t. r p = amplitude of p th term. p = time constant of r th term. the coefficients for this device are shown in the tables below: d.c. double side cooled term 1234 r p 0.12000552 0.01609235 8.81267310 -3 3.65976510 -3 p 0.3391689 0.09405764 0.12195269 2.19619710 -3 d.c. single side cooled term 12345 r p 0.06157697 8.43118210 -3 0.01031315 0.01613806 5.18108810 -3 p 2.136132 1.212898 0.1512408 0.04244 2.88959510 -3 9.0 reverse recovery ratings (i) q ra is based on 50% i rm chord as shown in fig. 1 fig. 1 (ii) q rr is based on a 150 s integration time i.e. = s rr rr dt i q 150 0 . (iii) 2 1 t t factor k =
westcode westcode westcode westcode an ixys company phase control thyristor types n0606ys200 to n0606ys250 data sheet. types n0606ys200 to n0606ys250 issue 2 page 6 of 11 october, 2004 curves figure 1 - on-state characteristics of limit device figure 2 - transient thermal impedance 100 1000 10000 012345 instantaneous on-state voltage - v tm (v) instantaneous on-state current - i tm (a) t j = 125c t j = 25c 0.001 0.01 0.1 1 0.001 0.01 0.1 1 10 100 time (s) thermal impedance (k/w) ssc 0.1k/w dsc 0.05k/w figure 3 - gate characteristics - trigger limits figure 4 - gate characteristics - power curves 0 1 2 3 4 5 6 7 8 9 10 0 0.1 0.2 0.3 0.4 0.5 0.6 gate trigger current - i gt (a) gate trigger voltage - v gt (v) i gd , v gd i gt , v gt min v g dc max v g dc t j =25c 25c -10c -40c 125c 0 5 10 15 20 25 30 0246810 gate trigger current - i gt (a) gate trigger voltage - v gt (v) p g 2w dc p g max 30w dc min v g dc max v g dc t j =25c n0606ys200-250 issue 2 n0606ys200-250 issue 2 n0606ys200-250 issue 2 n0606ys200-250 issue 2
westcode westcode westcode westcode an ixys company phase control thyristor types n0606ys200 to n0606ys250 data sheet. types n0606ys200 to n0606ys250 issue 2 page 7 of 11 october, 2004 figure 5 - total recovered charge, q rr figure 6 - recovered charge, q ra (50% chord) 1000 10000 1 10 100 1000 commutation rate - di/dt (a/s) total recovered charge - q rr (c) t j = 125c 1500a 1000a 550a 2000a 100 1000 10000 1 10 100 1000 commutation rate - di/dt (a/s) recovered charge - q ra (c) t j = 125c 2000a 1500a 1000a 550a figure 7 - peak reverse recovery current, i rm figure 8 - maximum recovery time, t rr (50% chord) 10 100 1000 1 10 100 1000 commutation rate - di/dt (a/s) reverse recovery current - i rm (a) 2000a 1500a 1000a 550a t j = 125c 1 10 100 1 10 100 1000 commutation rate - di/dt (a/s) recovery time - t rr (s) t j = 125c 2000a 1500a 1000a 5500a n0606ys200-250 issue 2 n0606ys200-250 issue 2 n0606ys200-250 issue 2 n0606ys200-250 issue 2
westcode westcode westcode westcode an ixys company phase control thyristor types n0606ys200 to n0606ys250 data sheet. types n0606ys200 to n0606ys250 issue 2 page 8 of 11 october, 2004 figure 9 ? on-state current vs. power dissipation ? double side cooled (sine wave) figure 10 ? on-state current vs. heatsink temperature - double side cooled (sine wave) 0 500 1000 1500 2000 2500 0 200 400 600 800 mean forward current (a) (whole cycle averaged) maximum forward dissipation (w) 30 60 90 120 180 0 20 40 60 80 100 120 140 0 200 400 600 800 mean forward current (a) (whole cycle averaged) maximum permissable heatsink temperature (c) 30 60 90 120 180 figure 11 ? on-state current vs. power dissipation ? double side cooled (square wave) figure 12 ? on-state current vs. heatsink temperature ? double side cooled (square wave) 0 500 1000 1500 2000 2500 0 200 400 600 800 1000 1200 mean forward current (amps) (whole cycle averaged) maximum forward dissipation (w) 30 60 90 120 180 d.c. 270 0 20 40 60 80 100 120 140 0 200 400 600 800 1000 1200 mean forward current (amps) (whole cycle averaged) maximum permissible heatsink temperature (c) 30 60 90 120 180 d.c. 270 n0606ys200-250 issue 2 n0606ys200-250 issue 2 n0606ys200-250 issue 2 n0606ys200-250 issue 2
westcode westcode westcode westcode an ixys company phase control thyristor types n0606ys200 to n0606ys250 data sheet. types n0606ys200 to n0606ys250 issue 2 page 9 of 11 october, 2004 figure 13 ? on-state current vs. power dissipation ? single side cooled (sine wave) figure 14 ? on-state current vs. heatsink temperature ? single side cooled (sine wave) 0 200 400 600 800 1000 1200 0 100 200 300 400 500 600 mean forward current (a) (whole cycle averaged) maximum forward dissipation (w) 30 60 90 120 180 0 20 40 60 80 100 120 140 0 100 200 300 400 500 600 mean forward current (a) (whole cycle averaged) maximum permissable heatsink temperature (c) 30 60 90 120 180 figure 15 ? on-state current vs. power dissipation ? single side cooled (square wave) figure 16 ? on-state current vs. heatsink temperature ? single side cooled (square wave) 0 200 400 600 800 1000 1200 0 100 200 300 400 500 600 700 mean forward current (amps) (whole cycle averaged) maximum forward dissipation (w) 30 60 90 120 180 d.c. 270 0 20 40 60 80 100 120 140 0 100 200 300 400 500 600 700 mean forward current (amps) (whole cycle averaged) maximum permissible heatsink temperature (c) 30 60 90 120 180 d.c. 270 n0606ys200-250 issue 2 n0606ys200-250 issue 2 n0606ys200-250 issue 2 n0606ys200-250 issue 2
westcode westcode westcode westcode an ixys company phase control thyristor types n0606ys200 to n0606ys250 data sheet. types n0606ys200 to n0606ys250 issue 2 page 10 of 11 october, 2004 figure 17 - maximum surge and i 2 t ratings 1000 10000 100000 total peak half sine surge current (a) 1.00e+05 1.00e+06 1.00e+07 maximum i 2 t (a 2 s) 13 510 1 5 10 50 100 duration of surge (ms) duration of surge (cycles @ 50hz) i 2 t: 60% v rrm i tsm : 60% v rrm i 2 t: v rrm 10v i tsm : v rrm 10v t j (initial) = 125c n0606ys200-250 issue 2
westcode westcode westcode westcode an ixys company phase control thyristor types n0606ys200 to n0606ys250 data sheet. types n0606ys200 to n0606ys250 issue 2 page 11 of 11 october, 2004 outline drawing & ordering information 101a335 ordering information (please quote 10 digit code as below) n0606 ys     0 fixed type code fixed outline code voltage code v drm /100 20-25 fixed turn-off time code order code: n0606ys250 ? 2500v v drm , v rrm , 15.1mm clamp height capsule. westcode ixys semiconductor gmbh edisonstra?e 15 d-68623 lampertheim tel: +49 6206 503-0 fax: +49 6206 503-627 e-mail: marcom@ixys.de an ixys company westcode semiconductors ltd langley park way, langley park, chippenham, wiltshire, sn15 1ge. tel: +44 (0)1249 444524 fax: +44 (0)1249 659448 e-mail: wsl.sales@westcode.com ixys corporation 3540 bassett street santa clara ca 95054 usa tel: +1 (408) 982 0700 fax: +1 (408) 496 0670 e-mail: sales@ixys.net www.westc ode.com www.ixys.com westcode semiconductors inc 3270 cherry avenue long beach ca 90807 usa tel: +1 (562) 595 6971 fax: +1 (562) 595 8182 e-mail: wsi.sales@westcode.com the information contained herein is confidential and is protected by copyright. the information may not be used or disclosed except with the written permission of and in the manner permitted by the proprietors westcode semiconductors ltd. in the interest of product improvement, westcode reserves the right to change specifications at any time without prior notice. devices with a suffix code (2-letter, 3-letter or letter/digit/letter combination) added to their generic code are not necessar ily subject to the conditions and limits contained in this report. ? westcode semiconductors ltd.
westcode westcode westcode westcode an ixys company phase control thyristor types n0606ys200 to n0606ys250 data sheet. types n0606ys200 to n0606ys250 issue 2 page 12 of 11 october, 2004


▲Up To Search▲   

 
Price & Availability of N0606YS220

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X