vicor corp. tel: 800-735-6200, 978-470-2900 fax: 978-475-6715 mi-aim, ac input front end module rev. 1.2 page 1 of 5 set your site on vicor at www.vicorpower.com features ? inputs: 115 vac 60/400 hz ? output power: 250 w ? mil-std-704a-f input transient protection ? mil-std-461d/e emi compliant ? mil-std-810, mil-std-202 environments ? compatible with mi-x7x family modules ? efficiency: 95% ? operating temperature to 100?c ? size: 2.28" x 2.4" x 0.5" (57,9 x 61,0 x 12,7 mm) product highlights the ac input module interfaces directly with ac mains to provide line rectification, emi filtering, transient protection, and inrush limiting. these front-end modules accept 115 vac and provide 250 w of output power for any of vicor's mi-x7x family of standard and junior size modules. the mi-aim meets ce102 conducted emissions requirements of mil-std-461d/e and the transient and spike requirements of mil-std-704a-f. fully encapsulated in vicors industry standard package, the mi-aim meets mil-std-810 environmental testing requirements for humidity, fungus, salt- fog, explosive atmosphere, acceleration, vibration and shock. packaging options standard: slotted baseplate slimmod: flangeless baseplate, option suffix: - s example: mi - aim - m1 - s finmod: finned heat sink, option suffix: - f1, - f2, -f3 or -f4 examples: mi - aim - m1 - f1 , 0.25" fins, longitudinal mi - aim - m1 - f2 , 0.50" fins, longitudinal mi - aim - m1 - f3 , 0.25" fins, transverse mi - aim - m1 - f4 , 0.50" fins, transverse actual size: 2.28 x 2.4 x 0.5 in 57,9 x 61,0 x 12,7 mm data sheet mi-aim ac input front end module model number compatible mi-series converter operating temp (c) storage temp (c) mi-aim-m1 mi-27x / mi-j7x m?grade ?55 to +85 / +100 ?65 to +100 / +125 mi-aim-i1 mi-27x / mi-j7x i?grade ?40 to +85 / +100 ?55 to +100 / +125 model selection chart input characteristics parameter min typ max unit notes ac line input 85 115 140 vac 47 60/400 440 hz operates over entire range inrush current 40 a, peak 125 vac transient input (v) 80 vrms 20 ms, per mil-std-704a 180 vrms 100 ms, per mil-std-704a (f) 480 hz peak, per mil-std-704a conducted emi ce102 per mil-std-461 d/e 100 ? 125 vac; 60 hz spikes 50 % nominal line voltage, 50 s output characteristics parameter min typ max unit notes output power 250 w 100c hold-up time application specific a function of external capacitance and power efficiency 95% 115 vac; 60/400 hz
vicor corp. tel: 800-735-6200, 978-470-2900 fax: 978-475-6715 mi-aim, ac input front end module rev. 1.2 page 2 of 5 set your site on vicor at www.vicorpower.com specifications (typical at t bp = 25c, nominal line and 75% load, unless otherwise specified) safety specifications parameter min typ max unit notes dielectric withstand input to output none provided by dc-dc converter input/output to baseplate 1,500 v rms environmental ? mil-std-810d parameter min typ max unit notes altitude - method 500.2 70,000 feet procedure ii humidity - method 507.2 88 / 240 %/ hours procedure i, cycle 1 acceleration - method 513.3 9.0 g procedure ii vibration - method 514.3 20 g procedure i, category 6 shock - method 516.3 40 g procedure i general specifications parameter min typ max unit notes size 2.28 x 2.4 x 0.5 in (57,9 x 61,0 x 12,7) (mm) weight 3.0 ounces (85) (grams) reliability ? mil-hdbk-217f (mi-aim-m1) parameter min typ max unit notes 25c ground benign: g.b. 5,545 1,000 hrs 50c naval sheltered: n.s. 998 1,000 hrs 65c airborne inhabited cargo: a.i.c. 782 1,000 hrs
vicor corp. tel: 800-735-6200, 978-470-2900 fax: 978-475-6715 mi-aim, ac input front end module rev. 1.2 page 3 of 5 set your site on vicor at www.vicorpower.com parameter i-grade m-grade storage temperature -55c to +125c -65c to +125c operating temperature (baseplate) -40c to +100c -55c to +100c power cycling burn-in 12 hours, 29 cycles 96 hours, 213 cycles temperature cycled with power off 12 cycles 12 cycles 17c per minute rate of change -65c to +100c -65c to +100c test data supplied at these temperatures [a] -40c, +80c -55c, +80c warranty 2 years 2 years environmental compliance mil-std-810 mil-std-810 derating navmat p-4855-1a navmat p-4855-1a product grade specifications specifications (cont.) [a] test data available for review or download from vicorpower.com parameter qualification altitude mil-std-810d, method 500.2, procedure iii, explosive decompression (40 k ft.). mil-std-810d, method 500.2, procedure ii, 40,000 ft., 1000 ? 1500 ft./ min. to 70,000 ft., unit functioning explosive atmosphere mil-std-810c, method 511.1, procedure i vibration mil-std-810d, method 514.3, procedure i, category 6, helicopter, 20 g mil-std-810d, method 514.3 random: 10 ? 300 hz @ 0.02 g 2 /hz, 2000 hz @ 0.002 g 2 / hz, 3.9 total g rms 3 h rs / axis. sine: 30 hz @ 20 g, 60 hz @ 10 g, 90 hz @ 6.6 g, 120 hz @ 5.0 g, 16.0 total g rms, 3 axes mil-std-810e, method 514.4, table 514.4-vii, 6 db / octave, 7.7 g rms, 1hr / axis shock mil-std-810d, method 516.3, procedure i, functional shock, 40 g mil-std-202f, method 213b, 18 pulses, 60 g, 9 msec mil-std-202f, method 213b, 75 g, 11 ms saw tooth shock mil-std-202f, method 207a, 3 impacts / axis, 1, 3, 5 feet acceleration mil-std-810d, method 513.3, procedure ii operational test, 9 g for 1 minute along 3 mutually perpendicular axes humidity mil-std-810d, method 507.2, procedure i, cycle i, 240 hrs, 88% relative humidity solder test mil-std-202, method 208, 8 hr. aging fungus mil-std-810c, method 508.1 salt-fog mil-std-810c, method 509.1 environmental qualifications
vicor corp. tel: 800-735-6200, 978-470-2900 fax: 978-475-6715 mi-aim, ac input front end module rev. 1.2 page 4 of 5 set your site on vicor at www.vicorpower.com 5 6 7 8 9 4 3 2 1 .080 dia (2) places solder plate over copper alloy .040 (1,0) dia (7) places solder plate over copper alloy .01 aluminum base product id this surface function l1 l2/n +out parallel gate out ?out pin # 1 2 3 4 5 6 7 8 9 full r +.030 -.000 (5,6) min. .30 min. 1.75 max. 2.40 2.28 .12 .50 1.90 .65 (16,5) .49 (12,4) .30 .015 .15 2.10 (53,4) 1.30 .40 (10,2) .35 .015 (8,9) (0,38) 1.40 (35,6) 1.00 (25,4) .70 (17,8) nc nc gate in vi-aim (57,9) (33,0) (7,6) (0,38) (3,8) .15 (3,8) (48,3) (3,0) .22 (12,7) (0,76) (0) (7,6) (61,0) (44,4) mechanical drawings, connection diagram figure 1 mi-aim connection diagram, typical application figure 2 mechanical diagram mi-aim ac in mi-aim gate out par gate in +out ?out l2/n n/c n/c l1 ?out ?s trim +s +out +in ?in mi-27x/j7x driver load f2 c1 [b] f1 0.47 f 0.01 f (two 4700 pf) y-rated capacitors 0.01 f (two 4700 pf) y-rated capacitors 0.01 f ceramic 0.01 f ceramic gate in gate out [b] 1,200 f max. fuse 1: 7a f03a type recommended fuse 2: mi-x7x-xx ? buss pc ? tron 2 ? 5 a (450 v) in (mm) note: for alternate packaging options refer to the mechanical drawing page at vicorpower.com
vicor corp. tel: 800-735-6200, 978-470-2900 fax: 978-475-6715 mi-aim, ac input front end module rev. 1.2 9/07 set your site on vicor at www.vicorpower.com vicor corporation 25 frontage road andover, ma, usa 01810 tel: 800-735-6200 fax: 978-475-6715 email customer service: custserv@vicorpower.com technical support: apps@vicorpower.com vicors comprehensive line of power solutions includes high density ac-dc and dc-dc modules and accessory components, fully configurable ac-dc and dc-dc power supplies, and complete custom power systems. information furnished by vicor is believed to be accurate and reliable. however, no responsibility is assumed by vicor for its use. vicor components are not designed to be used in applications, such as life support systems, wherein a failure or malfunction could result in injury or death. all sales are subject to vicors terms and conditions of sale, which are available upon request. specifications are subject to change without notice. intellectual property notice vicor and its subsidiaries own intellectual property (including issued u.s. and foreign patents and pending patent applications) relating to the products described in this data sheet. interested parties should contact vicor's intellectual property department. warranty vicor products are guaranteed for two years from date of shipment against defects in material or workmanship when in normal use and service. this warranty does not extend to products subjected to misuse, accident, or improper application or maintenance. vicor shall not be liable for collateral or consequential damage. this warranty is extended to the original purchaser only. except for the foregoing express warranty, vicor makes no warranty, express or implied, including, but not limited to, the warranty of merchantability or fitness for a particular purpose. vicor will repair or replace defective products in accordance with its own best judgement. for service under this warranty, the buyer must contact vicor to obtain a return material authorization (rma) number and shipping instructions. products returned without prior authorization will be returned to the buyer. the buyer will pay all charges incurred in returning the product to the factory. vicor will pay all reshipment charges if the product was defective within the terms of this warranty. information published by vicor has been carefully checked and is believed to be accurate; however, no responsibility is assumed for inaccuracies. vicor reserves the right to make changes to any products without further notice to improve reliabilit y, function, or design. vicor does not assume any liability arising out of the application or use of any product or circuit; neith er does it convey any license under its patent rights nor the rights of others. vicor general policy does not recommend the use of its components in life support applications wherein a failure or malfunction may directly threaten life or injury. per vicor terms and conditions of sale, the user of vicor components in life support applications assumes all risks of such use and indemnifies vicor against all damages.
|