  microstructure pressure sensors precision compensated 0 in h 2 o to 4 in h 2 o and 0 in h 2 o to 10 in h 2 o scxl serie s sensing and control features ? very low pressure resolution ? precision temperature compensation ? small size ? low noise ? calibrated zero & span ? high impedance for low power applications typical applications ? air flow ? respirators ? hvac ? medical equipment ? computer peripherals ? pneumatic controls warning personal injury do not use these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury. failure to comply with these instructions could result in death or serious injury. the scxl series sensors provide a very cost-effective solution for pressure applications that require high accuracy over very low operating pressure ranges. these internally calibrated and temperature compensated sensors were specifically designed to provide an accurate and stable output over a 0 c to 50 c [32 f to 122 f] temperature range. this series is intended for use with non-corrosive, non-ionic working fluids such as air, dry gases and the like. the output of the bridge is ratiometric to the supply voltage. operation from any dc supply voltage up to 18 vdc [model scxl004dn] or 20 vdc [SCXL010DN] is acceptable. contact your local honeywell representative or go to honeywell?s website at www.honeywell.com/sensing for additional details. warning misuse of documentation ? the information presented in this product sheet is for reference only. do not use this document as a product installation guide. ? complete installation, operation, and maintenance information is provided in the instructions supplied with each product. failure to comply with these instructions could result in death or serious injury.
microstructure pressure sensors precision compensated 0 in h 2 o to 4 in h 2 o and 0 in h 2 o to 10 in h 2 o scxl series 2 honeywell ? sensing and control general specifications characteristic description (maximum ratings) scxl004dn description (maximum ratings) SCXL010DN supply voltage (v s) 18 vdc 20 vdc common mode pressure 150 in h 2 o 50 psig lead soldering temperature (2 seconds to 4 seconds) 250 c [482 f] 250 c [482 f] proof pressure (12) 10 in h 2 o 10 psi burst pressure 5 psi 200 in h 2 o environmental specifications characteristic description (maximum ratings) scxl004dn description (maximum ratings) SCXL010DN compensated operating temperature 0 c to 50 c [32 f to 122 f] 0 c to 50 c [32 f to 122 f] operating temperature 0 c to 70 c [32 f to 158 f] -40 c to 85 c [-40 f to 185 f] storage temperature 0 c to 70 c [32 f to 158 f] -40 c to 125 c [-40 f to 257 f] humidity limits 0 % to 100 % rh 0 % to 100 % rh pressure range specifications full-scale span (1) listing operating pressure proof pressure (2) min. typ. max. scxl004dn 0 in h 2 o to 4 in h 2 o 10 in h 2 o 38.0 mv 40.0 mv 42.0 mv SCXL010DN 0 in h 2 o to10 in h 2 o 10 psi 19.5 mv 20.0 mv 20.5 mv scxl004dn performance characteristics (3) characteristic min. typ. max. unit zero pressure offset (4) -1.5 0 1.5 mv sensitivity ? 10 ? mv/in h 2 o combined pressure non-linearity and pressure hysteresis (5) ? 0.5 1.0 % fss temperature effect on span 0 c to 50 c [32 f to 122 f] (6) ? 0.2 1.0 % fss temperature effect on offset 0 c to 50 c [32 f to 122 f] (6) ? 0.5 2.0 mv repeatability (7) ? 0.2 ? % fss input resistance (8) ? 4.0 ? kohm output resistance (9) ? 4.0 ? kohm common mode voltage (10) 5.7 6.0 6.3 vdc response time (11) ? 500 ? microsec. long term stability of offset and span (12) ? 0.5 ? % fss position sensitivity ? 0.25 ? mv/g
microstructure pressure sensors precision compensated 0 in h 2 o to 4 in h 2 o and 0 in h 2 o to 10 in h 2 o scxl series honeywell ? sensing and control 3 SCXL010DN performance characteristics (3) characteristic min. typ. max. unit zero pressure offset (4) -0.3 0.0 0.3 mv sensitivity ? 2 ? mv/in h 2 o combined pressure non-linearity and pressure hysteresis (5) ? 0.2 0.5 % fss temperature effect on span 0 c to 50 c [32 f to 122 f] (6) ? 0.2 1.0 % fss temperature effect on offset 0 c to 50 c [32 f to 122 f] (6) ? 300 500 microvolts repeatability (7) ? 0.2 0.5 % fss input resistance (8) ? 4.0 ? kohm output resistance (9) ? 4.0 ? kohm common mode voltage (10) 5.8 6.0 6.2 vdc response time (11) ? 100 ? microsec. long term stability of offset and span (12) ? 100 ? microvolts specification notes note 1: full-scale span is the algebraic difference between the output voltage at full-scale pressure and the output at zero pr essure. full-scale span is ratiometric to the supply voltage. note 2: proof pressure is the pressure above whic h devices will not return to guaranteed specifications. note 3: reference conditions: (unless otherwise noted) t a = 25 c, supply v s = 12 vdc, common mode line pressure = 0 psig, pressure applied to port b. for absolute devices only, pressure is applied to port a, and the output polarity is reversed. note 4: zero pressure effect is measured with pins pointed towards the ground. offset can be position sensitive. note 5: pressure hysteresis ? the maximum output difference at any point within the operating pressure range for increasing and decreasing pressure. note 6: maximum error band of the offset voltage and the error band of the span, relative to the 25 c [77 f] reading. note 7: maximum difference in output at any pressure within the operating pressure range and the temperature within 0 c to 50 c [32 f to 122 f] after: 004dn: a) 100 temperature cycles, 0 c to 50 c [32 f to 122 f] b) 1 million pressure cycles, 0 psi to full-scale span. 010dn: a) 1,000 temperature cycles, 0 c to 50 c [32 f to 122 f] b) 1.5 million pressure cycles, 0 psi to full-scale span. note 8: input resistance is the resistance between pins 2 and 4. note 9: output resistance is the resistance between pins 3 and 5. note 10: common mode voltage of the output arms (pins 3 and 5) for v s =12 vdc. note 11: response time for a 0 psi to full-scale span pressure step change, 10 % to 90 % rise time. note 12: long term stability over a one-year period. ordering information description part number 0 in h 2 o to 4 in h 2 o scxl 004dn 0 in h 2 o to 10 in h 2 o scxl 010dn special options: pins with n-90 = 90 lead bend electrical connection pinout scxl004dn [0 in h 2 o to 4 in h 2 o] scxl004dn [0 in h 2 o to 10 in h 2 o] pin 1) temperature output (+) pin 2) v s pin 3) + output pin 4) ground pin 5) - output pin 6) temperature output (-) pin 1) no connection pin 2) v s pin 3) + output pin 4) ground pin 5) - output pin 6) no connection
microstructure pressure sensors precision compensated 0 in h 2 o to 4 in h 2 o and 0 in h 2 o to 10 in h 2 o scxl series sensing and control www.honeywell.com/sensing honeywell 11 west spring street freeport, illinois 61032 008102-3-en il50 glo 504 printed in usa copyright 2004 honeywell international inc. all rights reserved physical dimensions for reference only-(mm/in) warranty/remedy honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. contact your local sales office for warranty information. if warranted goods are returned to honeywell during the period of coverage, honeywell will repair or replace without charge those items it finds defective. the foregoing is buyer?s sole remedy and is in lieu of all other warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. specifications may change without notice. the information we supply is believed to be accurate and reliable as of this printing. however, we assume no responsibility for its use. while we provide application assistance personally, through our literature and the honeywell web site, it is up to the customer to determine the suitability of the product in the application. for application assistance, current specifications, or name of the nearest authorized distributor, contact a nearby sales office. or call: 1-800-537-6945 usa/canada 1-815-235-6847 international fax 1-815-235-6545 usa internet www.honeywell.co m/sensing info.sc@honeywell.com


▲Up To Search▲   

 
Price & Availability of SCXL010DN

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X