terminal blocks for chassis mounting 0.5 22 10 10 2.1 1.0 216-141 1000 0.75 20 10 10 2.3 1.2 216-142 1000 1.0 18 10 10 2.5 1.4 216-143 1000 1.5 16 10 10 2.8 1.7 216-144 1000 0.5 22 white 12.0 16.0 10.0 3.1 2.6 1.0 216-241 1000 0.75 20 grey 12.0 16.0 10.0 3.3 2.8 1.2 216-242 1000 1.0 18 red 12.0 16.0 10.0 3.5 3.0 1.4 216-243 1000 1.5 16 black 12.0 16.0 10.0 4.0 3.5 1.7 216-244 1000 862 series 12 0.47 24 0.94 36 1.42 24 0.94 48 1.89 sleeve awg color stripped l l1 d d d2 item pack.-unit for mm 2 length mm mm no. pcs fasten via screw and nut ( 3 m m ?) from top fasten from below via self tapping screw (2. 9 m m ?) into terminal housing fasten onto chassis by self tapping screw (2. 9 m m ?) from top fasten via screw (3mm?) into thread in chassis fasten via screw and nut ( 3 m m ?) from top dimensions (mm) fastening via snap-in mounting feet insulated ferrules uninsulated ferrules ferrules crimp tool 206-204 0.25 - 4 mm 2 awg 24 - 12 stripper / cutter 206-101 0.5 - 6 mm 2 awg 28 - 8 wago corporation n120 w19129 freistadt road; p.o. box 1015; germantown, wi 53022 1-800 din rail (346-7245) fax: (262) 255-3232 info.us@wago.com www.wago. us 51011208 0888- 0153/0001-3601 rev2 10/0 5 printed in the united state s fastening options subject to design changes tools
2.3 mm /0.091 in ?, yellow 210-13 7 50 (5 x 10) cost-effective features: the new 862 series chassis mount terminal block was developed specifically to minimize wiring costs, while accommodating requirements for easy mounting, multiple connection points, marking, and handling. ? the new 862 series allows the connection of up to four conductors from wire size 20 to 12 awg. due to the multiple connection points per pole, different wire sizes can be used within the same terminal block position. ? the cage clamp ? s termination technology allows solid conductors, stranded conductors with ferrules, or ultrasonically bonded conductors to be easily connected by simply pushing the conductor into the contact. ? an integrated push button, with molded-in slots, accommodates fast and easy wiring of all conductor types - either by hand, or with a slotted tip/ phillips screwdriver. ? convenient automatic grounding contact available as an option (see page 3 for illustration). ? snap-in mounting feet for fast assembly (see back page for illustration). ? flexible marking options with standard marking (pre-marked), marker strip, or custom marked per your specifications with large quantity orders. ? built-in test points simplify testing with 2 mm / 0.079 in diameter test plug. ? makes an automatic contact to the mounting plate ? varnish coating is penetrated automatically ? four conductors per pole ? for solid and flexible conductors ? mixed wiring with solid and flexible conductors of different cross sections ? marking by direct printing and/or marker strips ? testing with test plug 2 mm ? 4 poles /16 connection points 5 poles /20 connection points ground (earth) contact conductor connection marking and testing 862-0504 862-0604 200 862-1504 862-1604 200 862-2504 862-2604 200 862-8504 862-8604 200 862-9504 862-9604 200 862-0534 862-0634 200 862-1534 862-1634 200 862-2534 862-2634 200 862-8534 862-8634 200 862-9534 862-9634 200 862-0594 862-0694 200 862-1594 862-1694 200 862-2594 862-2694 200 862-8594 862-8694 200 862-9594 862-9694 2 00 862-0505 862-0605 200 862-1505 862-1605 200 862-2505 862-2605 200 862-8505 862-8605 200 862-9505 862-9605 200 862-0525 862-0625 200 862-1525 862-1625 200 862-2525 862-2625 200 862-8525 862-8625 200 862-9525 862-9625 200 862-0515 862-0615 200 862-1515 862-1615 200 862-2515 862-2615 200 862-8515 862-8615 200 862-9515 862-9615 2 00 for fastening screw 3 mm ? or for self tapping screw 2. 9 m m ? from top without marking pe-n-l1-l2 (pre-marked) n-pe-l1-l2 (pre-marked) (pre-marked) n-pe-l1-l2 (pre-marked) pe-n-l1-l2 1 snap-in foot per pole without marking pe-n-l1-l2 (pre-marked) n-pe-l1-l2 (pre-marked) (pre-marked) n-pe-l1-l2 (pre-marked) pe-n-l1-l2 snap-in feet at pos. 1+4 without marking pe-n-l1-l2 (pre-marked) n-pe-l1-l2 (pre-marked) (pre-marked) n-pe-l1-l2 (pre-marked) pe-n-l1-l2 for fastening screw 3 mm ? or for self tapping screw 2. 9 m m ? from top without marking pe-n-l1-l2-l3 (pre-marked) l3-n-pe-l1-l2 (pre-marked) (pre-marked) l3-n-pe-l1-l2 (pre-marked) pe-n-l1-l2-l3 1 snap-in feet at pos. 2+4 without markin g pe-n-l1-l2-l3 (pre-marked) l3-n-pe-l1-l2 (pre-marked) (pre-marked) l3-n-pe-l1-l2 (pre-marked) pe-n-l1-l2-l3 snap-in feet at pos. 1+3+ 5 without marking pe-n-l1-l2-l3 (pre-marked) l3-n-pe-l1-l2 (pre-marked) (pre-marked) l3-n-pe-l1-l2 (pre-marked) pe-n-l1-l2-l3 4 x 0.5 C 4 m m 2 4 x awg 20 C12 500 v/6 kv/2 300 v, 20 a 32 a 600 v, 5 a 2 u l 10 C 11 mm / 0.41 in 4 x 0.5 C 4 m m 2 4 x awg 20 C12 500 v/6 kv/2 300 v, 20 a 32 a 600 v, 5 a 2 u l 10 C 11 mm / 0.41 in item no. item no. pack.-unit black white pcs item no. item no. pack.-unit black white pcs 862-0552 862-0652 500 862-1552 862-1652 500 862-2552 862-2652 500 862-0562 862-0662 500 862-1562 862-1662 500 862-2562 862-2662 500 862-0532 862-0632 500 862-1532 862-1632 500 862-2532 862-2632 500 862-0503 862-0603 250 862-1503 862-1603 250 862-2503 862-2603 250 862-8503 862-8603 250 862-9503 862-9603 250 862-0533 862-0633 250 862-1533 862-1633 250 862-2533 862-2633 250 862-8533 862-8633 250 862-9533 862-9633 250 862-0593 862-0693 250 862-1593 862-1693 250 862-2593 862-2693 250 862-8593 862-8693 250 862-9593 862-9693 250 862 series - terminal block for chassis mounting 4 x 0.5 C 4 m m 2 4 x awg 20 C12 500 v/6 kv/2 300 v, 20 a 32 a 600 v, 5 a 2 u l 10 C 11 mm / 0.41 in item no. item no. pack.-unit black white pcs item no. item no. pack.-unit black white pcs comb-type jumper bar , can easily be inserted into the available in black and white 2 poles /8 connection points 3 poles /12 connection points for fastening screw 3 mm / 0.008 in ? or for self tapping screw 2. 9 m m / 0.114 in ? from top without marking pe-n-l1 (pre-marked) n-pe-l1 (pre-marked) (pre-marked) n-pe-l1 (pre-marked) pe-n-l1 1 snap-in foot per pole without marking pe-n-l1 (pre-marked) n-pe-l1 (pre-marked) (pre-marked) n-pe-l1 (pre-marked) pe-n-l1 snap-in feet at pos. 1+3 without marking pe-n-l1 (pre-marked) n-pe-l1 (pre-marked) (pre-marked) n-pe-l1 (pre-marked) pe-n-l1 for fastening screw 3 mm /0.118 in ? or for self tapping screw 2. 9 m m / 0.114 in ? from top without marking l1-n (pre-marked) n-l1 (pre-marked) for self tapping screw 2. 9 mm / 0.114 mm ? from below without marking l1-n (pre-marked) n-l1 (pre-marked) 1 snap-in foot per pole without marking l1-n (pre-marked) n-l 1 ( pre-marked) wire entry, 32 a 862-482 5 accessories 4 x 0.5 C 4 m m 2 4 x awg 20 C12 500 v/6 kv/2 300 v, 20 a 32 a 600 v, 5 a 2 u l 10 C 11 mm / 0.41 in screwdriver , with partially inslated shaft (3.5 x 0.5) mm (.14 x .0025) in 210-620 1 test plug, with cable 500 mm / 1'7.7" 2 mm /0.079 in ?, red 210-136 1 m arker strip, white, plain for central marking ; 7.5 mm wide, on roll, 50 m long 709-178 1 test plug, with cable 500 mm / 1'7.7" m arker strip, white, plain for central marking ; 7.5 mm wide, on roll, 300 m long 709-188 1 without ground/ earth contact with ground/ earth contact available in black and white without ground/ earth contact with ground/ earth contact
|