ver : a_4 update : 2012.05.14 ac-dc power module aqc100 series 100 watts http://www.archcorp.com.tw tel: +886-2-26989508 fax: +886-2-26981319 -1- electrical specifications model no. AQC100-12S aqc100- 15s aqc100-24s aqc100-48s max output wattage (w) 85 w 85w 100w 100w voltage 90-264 vac or 120-370 vdc frequency (hz) 47-63 hz current (full load) <2.0 a max. (115 vac) / <1.0 a max. (230 vac) inrush current (<2ms) < 30 a max. (115 vac) / < 60 a max. (230 vac) leakage current < 0.5 ma max. input power factor pf>0.99 (115 vac) / pf>0.95 (230 vac) at full load voltage (v.dc.) 12v 15v 24v 48v voltage accuracy 2% current (a) max 7.08 5.66 4.2 2.1 line regulation 1% load regulation 1% minimum load 0% maximum capacitive load 70,000f 50,000f 6,000f 1,000f ripple & noise max. 120mv 150mv 200mv 240mv efficiency (typ.) 90% 90% 92% 93% hold-up time 10 ms (110 vac) min. output switching frequency 100~133 khz over power protection auto recovery over voltage protection zener diode clamp protection short circuit protection auto recovery, hiccup mode input-output (v.ac) 3000v input-fg (v.ac) 1500v isolation output-fg . (v.ac) 500v operating temperature -25c?+70c (with derating) storage temperature -25c?+85c temperature coefficient 0.03%/c ( 0~50c ) humidity 95% rh mtbf >250,000 h @ 25c (mil-hdbk-217f, notice 1) environment vibration 10~500hz, 2g 10min./1cycle, 60min. each along x, y, z axes. dimension (l x w x h) 4.3 x 2.3 x 1.18 inches ( 109.0 x 58.5 x 30.0 mm ) tolerance 0.1 mm weight 310 g physical cooling method free convection safety agency approvals ce, ul60950-1 emi (conducted & radiated emission) en61000-6-3 en 55022 class b (conductive plane to be connected to safety earth) emc ems (noise immunity) en 55024 en61000-4-2,3,4,5,6,8,11 key features ? switching power module for pcb mountable ? high efficiency up to 93% typical ? active pfc function, >0.95 (230vac), >0.99 (115vac) ? universal input: 90-264 vac ? low leakage current, <250ua ? four m3 mounting holes optional on bottom side ? remote on/off control ? en55022 class b meets ? class i and class ii construction ? continuous short circuit protection with hiccup mode and auto recover ? 3-years product warranty 1.all specifications valid at normal input voltage, full lo ad and +25c after warm-up time unless otherwise stated. 2.ripple & noise are measured at 20mhz of bandw idth with 0.1uf & 47uf parallel capacitor. 3.hold-up time measured at 90% vout.
ver : a_4 update : 2012.05.14 ac-dc power module aqc100 series 100 watts http://www.archcorp.com.tw tel: +886-2-26989508 fax: +886-2-26981319 -2- derating mechanical dimension ( top view ) block diagram efficiency versus load pin# single 1 1.2 0.1%mm ac in (n) 2 1.2 0.1%mm ac in (l) 3 1.2 0.1%mm fg 4 1.2 0.1%mm on / off (provide +5vdc controlled external) 5 1.8 0.1%mm +dc out 6 1.8 0.1%mm -dc out 7 1.2 0.1%mm trim remark: please reserve the pin 4 hole on pcb. if the remote on/off function is not required, please connect the pin 4 circuit lay out with pin6, or keep pin 4 floating.
ver : a_4 update : 2012.05.14 ac-dc power module aqc100 series 100 watts http://www.archcorp.com.tw tel: +886-2-26989508 fax: +886-2-26981319 -3- AQC100-12S vin vs efficiency load vs efficiency input voltage (v) 90 115 180 230 264 efficiency (%) 87.87 89.51 90.67 90.88 90.96 load (%) 10 20 30 40 50 115v (%) 78.62 85.67 88.07 89.14 89.76 230v (%) 73.49 83.84 86.57 88.55 89.76 load (%) 60 70 80 90 100 115v (%) 89.95 90.00 90.02 89.77 89.51 230v (%) 90.22 90.58 90.83 90.85 90.88 60.00% 65.00% 70.00% 75.00% 80.00% 85.00% 90.00% 95.00% 100.00% 90v 115v 180v 230v 264v vin eff% 55.00% 60.00% 65.00% 70.00% 75.00% 80.00% 85.00% 90.00% 95.00% 100.00% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% load eff% aqc100-15s vin vs efficiency load vs efficiency input voltage (v) 90 115 180 230 264 efficiency (%) 88.41 90.17 91.11 91.59 91.53 load (%) 10 20 30 40 50 115v (%) 74.53 83.09 86.59 88.41 89.20 230v (%) 73.94 82.70 85.31 87.77 89.14 load (%) 60 70 80 90 100 115v (%) 89.70 89.93 89.99 90.11 90.17 230v (%) 89.97 90.63 90.91 91.15 91.59 60.00% 65.00% 70.00% 75.00% 80.00% 85.00% 90.00% 95.00% 100.00% 90v 115v 180v 230v 264v vin eff% 55.00% 60.00% 65.00% 70.00% 75.00% 80.00% 85.00% 90.00% 95.00% 100.00% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% load eff%
ver : a_4 update : 2012.05.14 ac-dc power module aqc100 series 100 watts http://www.archcorp.com.tw tel: +886-2-26989508 fax: +886-2-26981319 -4- efficiency versus load aqc100-24s vin vs efficiency load vs efficiency input voltage (v) 90 115 180 230 264 efficiency (%) 90.45 92.45 93.62 93.35 93.26 load (%) 10 20 30 40 50 115v (%) 80.71 87.31 90.00 91.22 92.10 230v (%) 73.64 84.39 88.42 90.56 91.76 load (%) 60 70 80 90 100 115v (%) 92.41 92.51 92.53 92.47 92.45 230v (%) 92.54 92.97 93.28 93.52 93.35 60.00% 65.00% 70.00% 75.00% 80.00% 85.00% 90.00% 95.00% 100.00% 90v 115v 180v 230v 264v vin eff% 55.00% 60.00% 65.00% 70.00% 75.00% 80.00% 85.00% 90.00% 95.00% 100.00% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% load eff% aqc100-48s vin vs efficiency load vs efficiency input voltage (v) 90 115 180 230 264 efficiency (%) 91.22 93.13 94.24 94.59 94.66 load (%) 10 20 30 40 50 115v (%) 82.39 88.10 90.73 91.67 92.58 230v (%) 71.87 83.73 89.12 91.05 92.41 load (%) 60 70 80 90 100 115v (%) 92.92 93.02 93.11 93.16% 93.13 230v (%) 93.18 93.63 93.95 94.32 94.59 60.00% 65.00% 70.00% 75.00% 80.00% 85.00% 90.00% 95.00% 100.00% 90v 115v 180v 230v 264v vin eff% 55.00% 60.00% 65.00% 70.00% 75.00% 80.00% 85.00% 90.00% 95.00% 100.00% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% load eff%
|