mos fet relays g3vm-353a/a1/d/d1 35 mos fet relays g3vm-353a/a1/d/d1 analog-switching mos fet relays with spst-nc contact. general-purpose models added. ? switches ac and dc minute analog signals. ? general-purpose models (high on resistance) added. ? rohs compliant application examples ? electronic automatic exchange systems ? security systems ? datacom (modem) systems ? fa systems and measurement devices note: the actual product is marked differently from the image shown here. list of models dimensions note: all units are in millimeter s unless otherwise indicated. terminal arrangement/internal connections (top view) pcb dimensions (bottom view) actual mounting pad dimensions (recommended value, top view) contact form terminals load voltage (peak value) model number per stick number per tape spst-nc pcb terminals 350 vac g3vm-353a 100 --- g3vm-353a1 surface-mounting terminals g3vm-353d g3vm-353d1 g3vm-353d(tr) --- 1,500 g3vm-353d1(tr) 4.58 0.25 6.4 0.25 2.54 0.25 1.2 0.15 0.5 0.1 0.8 0.25 7.62 0.25 7.85 to 8.80 2.5 min. 3.65 +0.15 ? 0.25 0.25 +0.1 ? 0.05 4.58 0.25 6.4 0.25 2.54 0.25 1.2 0.15 7.62 0.25 10.0 max. 1.0 min. 1.0 min. 3.65 +0.15 ? 0.25 4.0 +0.25 ? 0.2 g3vm-353a/a1 g3vm-353d/d1 note: the actual product is marked different- ly from the image shown here. note: the actual product is marked different- ly from the image shown here. weight: 0.26 g weight: 0.26 g 43 12 g3vm-353a/a1 g3vm-353d/d1 43 12 four 0.8-dia. holes (0.56) (0.1) 2.54 2.54 (0.56) (0.1) g3vm-353a/a1 8.3 to 8.8 2.54 1.5 1.3 g3vm-353d/d1
36 mos fet relays g3vm-353a/a1/d/d1 absolute maximum ratings (ta = 25 c) values in parentheses are for the g3vm-353a1/d1. electrical characteristics (ta = 25 c) values in parentheses are for the g3vm-353a1/d1. recommended operating conditions use the g3vm under the following conditions so that the relay will operate properly. values in parentheses are for the g3vm-353a1/d1. item symbol rating unit measurement conditions input led forward current i f 50 ma repetitive peak led forward current i fp 1 a 100 s pulses, 100 pps led forward current reduction rate i f / c ? 0.5 ma/ ct a 25 c led reverse voltage v r 5v connection temperature t j 125 c output load voltage (ac peak/dc) v off 350 v continuous load current (ac peak/dc) i o 150 (100) ma on current reduction rate i on / c ? 1.5 ( ? 1) ma/ ct a 25 c connection temperature t j 125 c dielectric strength between input and output (see note 1.) v i-o 2,500 v rms ac for 1 min operating temperature t a ? 40 to +85 c with no icing or condensation storage temperature t stg ? 55 to +125 c with no icing or condensation soldering temperature (10 s) --- 260 c 10 s note: 1. the dielectric strength between the input and output was checked by applying voltage be- tween all pins as a group on the led side and all pins as a group on the light-receiving side. item symbol mini- mum typical maxi- mum unit measurement conditions input led forward voltage v f 1.0 1.15 1.3 v i f = 10 ma reverse current i r --- --- 10 av r = 5 v capacity between terminals c t --- 30 --- pf v = 0, f = 1 mhz trigger led forward current i ft --- 1 3 ma i off = 10 a output maximum resistance with output on r on --- 15 (30) 25 (50) i o = 150 ma (100 ma) current leakage when the relay is open i leak --- 0.0105 (0.003) 1.0 ai f = 5 ma, v off = 350 v capacity between terminals c off --- 85 (30) --- pf v = 0, f = 1mhz, i f = 5 ma capacity between i/o terminals c i-o --- 0.8 --- pf f = 1 mhz, v s = 0 v insulation resistance r i-o 1,000 --- --- m v i-o = 500 vdc, r oh 60% tu r n - o n t i m e t on --- 0.1 (0.25) 1.0 (0.5) ms i f = 5 ma, r l = 200 , v dd = 20 v (see note 2.) turn-off time t off --- 1.0 (0.5) 3.0 (1) ms v out i f t on t off 10% 90% i f 1 2 4 3 r l v dd v out note: 2. turn-on and turn-off times item symbol minimum typical maximum unit load voltage (ac peak/dc) v dd --- --- 280 v operating led forward current i f 5 --- 25 ma continuous load current (ac peak/dc) i o --- --- 150 (100) ma operating temperature t a ? 20 --- 65 c
mos fet relays g3vm-353a/a1/d/d1 37 engineering data g3vm-353a/d led forward current vs. ambient temperature i f - ta continuous load current vs. ambient temperature i o - ta led forward current vs. led forward voltage i f - v f led forward current i f (ma) continuous load current i o (ma) led forward current i f (ma) ambient temperature ta (
) ambient temperature ta
led forward voltage v f (v) continuous load current vs. on-state voltage i o - v on on-state resistance vs. ambient temperature r on - ta trigger led forward current vs. ambient temperature i fc - ta continuous load current i o (ma) on-state resistance r on ( ) trigger led forward current i fc (ma) on-state voltage v on (v ) ambient temperature ta (
) ambient temperature ta (
) turn on, turn off time vs. led forward current t on , t off - i f turn on, turn off time vs. ambient temperature t on , t off - ta current leakage vs. ambient temperature i leak - ta turn on, turn off time t on , t off (s) turn on, turn off time t on , t off (s) current leakage i leak (na) led forward current i f (ma) ambient temperature ta (
ambient temperature ta (
) 0 ? 20 60 20 40 80 100 120 100 80 60 40 20 0 0 ? 20 300 120 100 80 60 40 20 0 250 200 150 50 100 ta = 25c 0.6 0.8 1 1.2 1.6 1.8 1.4 100 30 50 10 3 5 1 0.3 0.5 0.1 ta = 25c ? 2 ? 1 0 2 1 200 ? 200 ? 100 0 100 i o = 150 ma t < 1s 15 0 ? 20 0 20 40 80 100 60 5 10 20 i off = 10 a 0 ? 40 5 100 80 60 40 20 0 ? 20 4 3 2 1 30 1 2000 100 ta = 25c v dd = 20 v, r l = 200 t on t off 1000 300 500 100 50 30 50 10 3 5 v dd = 20 v, r l = 200 i f = 5 ma 0 ? 40 1200 100 80 60 40 20 0 ? 20 800 600 400 200 t on t off 1000 v off = 350 v i f = 5 ma 0 20 60 100 40 1000 100 10 1 80
38 mos fet relays g3vm-353a/a1/d/d1 engineering data g3vm-353a1/d1 led forward current vs. ambient temperature i f - ta continuous load current vs. ambient temperature i o - ta led forward current vs. led forward voltage i f - v f led forward current i f (ma) continuous load current i o (ma) led forward current i f (ma) ambient temperature ta (
) ambient temperature ta
led forward voltage v f (v) continuous load current vs. on-state voltage i o - v on on-state resistance vs. ambient temperature r on - ta trigger led forward current vs. ambient temperature i fc - ta continuous load current i o (ma) on-state resistance r on ( ) trigger led forward current i fc (ma) on-state voltage v on (v ) ambient temperature ta (
) ambient temperature ta (
) turn on, turn off time vs. led forward current t on , t off - i f turn on, turn off time vs. ambient temperature t on , t off - ta current leakage vs. ambient temperature i leak - ta turn on, turn off time t on , t off (s) turn on, turn off time t on , t off (s) current leakage i leak (na) led forward current i f (ma) ambient temperature ta (
ambient temperature ta (
) 0 ? 20 60 20 40 80 100 120 100 80 60 40 20 0 0 ? 20 160 120 100 80 60 40 20 0 120 80 40 ta = 25c 0.6 0.8 1 1.2 1.6 1.8 1.4 100 30 10 3 1 0.3 0.1 ta = 25c ? 4 ? 1 0 4 1 150 ? 150 ? 50 0 100 50 ? 100 ? 2 ? 3 2 3 i o = 100 ma t < 1 s 40 0 20 30 50 10 i off = 10 ? 40 5 100 80 60 40 20 0 ? 20 4 3 2 1 1 100 ta = 25c v dd = 20 v, r l = 200 t on t off 30 50 10 3 5 300 10 3000 300 100 30 1000 10 ? 40 3000 100 80 60 40 20 0 ? 20 300 100 30 1000 t on t off v dd = 20 v, r l = 200 i f = 5 ma 1 0 20 40 60 80 100 10 100 1000 3 30 300 v off = 350 v i f = 5 ma
mos fet relays g3vm-353a/a1/d/d1 memo
mos fet relays g3vm-353a/a1/d/d1 omron on-line global - http://www.omron.com usa - http://www.components.omron.com cat. no. x302-e-1 printed in usa omron electronic components llc 55 e. commerce drive, suite b schaumburg, il 60173 847-882-2288 12/10 specificat ions subject to change without notice all sales are subject to omron electronic components llc standard terms and conditions of sale, which can be found at http://www.components.omron.com/compon ents/web/webfiles.ns f/sales_terms.html all dimensions shown are in millimeters. to convert millimeters into inches, multiply by 0.0393 7. to convert grams into ounces, multiply by 0.03527.
|