  Datasheet File OCR Text:
  data sheet pvx operation mode: program operation fixed value (fix) operation manual (man) operation digital input/output: time signal output: 4 points (ts1, ts2, ts3, ts4) external command input: 4 points (re- set, run, hold, advance) pattern select input: bcd 1 digit (2 3 , 2 2 , 2 1 , 2 0 ) status output (output informations): 3 points (reset, run/hold, end) option: auxiliary analog output: 2 points (ao1, ao2) expansion digital output: 2 points (ts5, ts6 or alm3, alm4) power source: flexible supply voltage: 100 to 240v ac the program controller x (pvx) is a high performance control- ler designed on the basis of many years of fuji? successful experience and advanced technologies. 1. display of 3 different datas three different datas such as measured value (pv), set value (sv) and time can be monitored simultaneously. 2. 20-segment program patterns (9 patterns) program patterns can be linked in series or repeated. 3. full multi-input type the program controller accepts a large number of inputs (full multi-input). up to 11 kinds of thermocouples, 1 resis- tance bulb, 6 different voltage inputs and a current input can be connected. 4. wide input/output functions (option) the program controller is able to expand the input/output functions up to 8 points of digital inputs, 11 points of digi- tal outputs and 2 points of auxiliary analog outputs. panel size: 96 96mm input: full multi-input thermocouple: j, k, r, b, t, e, s, n, u, wre5-26, pl-ii platinum resistance bulb: pt100 dc voltage/current input accuracy: 0.2% of full scale, 1 digit input sampling cycle: 100ms control action: pid with auto-tuning control output: relay contact voltage pulse output (for ssr drive) current output alarm output: 2 points (alm1, alm2) program function: number of patterns: 9 patterns (max.) number of segments/patterns: 20 seg- ments multi-memory (pid, etc.): 9 sets pattern linkage/repeat function: pos- sible time setting: hour/minute or minute/ second program controller x (96mm) features specifications date EDS11-124D jan. 31, 1997
2 pvx 1. input (1) input accuracy: 0.2% of full scale, 1 digit (under stan- dard condition), cold junction compensa- tion error: 1 c (2) input: j : 0 to 400 c pt100 ? (*): 0 to 150 c j : 0 to 800 c 0 to 300 c k : 0 to 400 c 0 to 500 c k : 0 to 800 c 0 to 600 c k : 0 to 1200 c ?0 to 100 c r : 0 to 1600 c ?00 to 200 c b : 0 to 1800 c ?99.9 to 600 c t : ?99.9 to 200 c ?99.9 to 850 c t : ?50 to 400 c jpt100(*) ? : 0 to 150 c e : 0 to 800 c 0 to 300 c e : ?99.9 to 800 c 0 to 500 c s : 0 to 1600 c 0 to 600 c n : 0 to 1300 c ?0 to 100 c u : ?99.9 to 400 c ?00 to 200 c wre5-26 : 0 to 2300 c ?99.9 to 600 c pl-ii : 0 to 1300 c (r: 1% within the range of 0 to 400 c) (b: 5% within the range of 0 to 500 c) dc voltage/current (full programmable scale; ?99 to 9999) 0 to 10mv dc, 0 to 100mv dc, 0 to 1v dc, 0 to 5v dc 1 to 5v dc, 0 to 10v dc, 4 to 20ma dc f display; possible 0.1 c/ f display; possible (1000 c/ f span or less) thermocouple (range code setting) resistance bulb (range code setting) 3. program setting (1) program function number of patterns: 9 patterns (max.) number of segments/patterns: 20 segments multi-memory (pid, etc.): 9 sets (2) operation mode program operation fixed value (fix) operation manual (man) operation (3) program operation pattern selection, program reset, start, stop and skip are possible with front panel key, digital input. (4) time setting setting of hour/minute or minute/second hour/minute: 0 (hr) 0 (min) to 99 (hr) 59 (min) minute/second: 0 (min) 0 (sec) to 99 (min) 59 (sec) 4. control action (1) auto-tuning pid action p: 0.0 to 999.9% (on/off control, p=0) i: 0 to 3200sec (integral action off, i=0) d: 0.0 to 900.0sec (derivative action off, d=0) (2) multi-memory pid, etc; up to 9 sets 5. digital input/output (1) digital input usual specification : 16v dc, 15ma external command input : reset: program reset run: program start hold: program stop advance: segment feed pattern select input : bcd input; 1 digit (2 3 , 2 2 , 2 1 , 2 0 ) (2) digital output time signal output (ts1, ts2, ts3, ts4) open-collector output: 4 points, 24v dc, 50ma status output : open-collector output: 3 points, 24v dc, 50ma reset: program reset status run/hold: program start/stop status end: program end status 6. option output (1) expansion digital output expansion alarm output (alm3, alm4) or expan- sion time signal output (ts5, ts6) open-collector output: 2 points, 24v dc, 50ma (2) auxiliary analog output output points : 1 or 2 points output data : measured value, set value or manipulated value output accuracy : 0.2% of full scale kinds of output : 1 to 5v dc 0 to 5v dc 0 to 10v dc additional function : scaling note: * pt100?ec pub751-1983 (3) input sampling cycle: 100ms 2. output (1) control output relay contact output : 220v ac/30v dc, 3a (resistive load) spdt contact electrical expected life: more than 10 5 op- erations minimum on/off current: 0.1a (24v dc) ssr drive output : on: 10 to 18v dc off: max. 0.5v max. current: 20ma dc current output : 4 to 20ma dc (allowable load: 600 ? or less) (2) alarm output (alm1, alm2) relay contact output : 2 points 220v ac/30v dc, 1a (resistive load) spst contact electrical expected life: more than 10 5 op- erations minimum on/off current: 0.1a(24v dc) functions and performance
3 7. operating conditions, etc. power supply voltage: 100 ( -15%) to 240 (+10%) vac, 50/ 60hz power consumption: 30va or less ambient temperature: 0 to 50 c ambient humidity: 90%rh or less (free from condensa- tion) memory backup: lithium battery (5 years expected: 0 to 40 c) dimensions (h w d): 96 96 173.5mm mass{weight}: 1kg (approx.) mounting angle: backward inclination within 15 note : if the range is not designated on or- der, the product will be delivered with the following range selected. k thermocouple 0 to 400 c. code symbols 12345678 910111213 pvx 1 2 3 t s ts c p d y t a y 0 1 2 y t e e 1- control output relay contact output ssr/ssc drive output current output (4 to 20ma dc) description digital input external command input (4 points) pattern select input (4 points) external command input +pattern select input output status expansion digital output (open-collector output, 2 points) without used as time signal (ts5, 6) used as alarm (alm3, 4) auxiliary analog output signal without voltage output, 1 point voltage output, 2 points note:prior to delivery from factory: 0 to 10v dc front panel indication and instruction manual (option) english time signal output, 1 to 4 communication function without with t-link
4 pvx functional block diagram external command input pattern select input reset sensor input full multi-input run hold advance 2 3 2 2 2 1 2 0 di fixed value,sv 9 patterns ficed value (fix) program setting, 20 segments 9 sets control parameter external command input reset run/hold end 3 points status output reset run/hold end control output ao do note :+2 points either time signal or alarm output can added (option). :communication function with t-link can be added (option). (option) ai pv pid with auto-tuning mv auto manual operation power supply, 100 to 240v ac auxiliary analog output, 1/2 points (pv/sv/mv) man sv filter program guarantee soak function time signal output, 4 points (+2 points) (note) alarm output, 2 points (+2 points) (note) pv start function pattern linkage function pattern repeat function (99,max.) pattern select input status output communication function with t-link (note)
5 main unit and panel mounting bracket 115 90.5 96 100 min. 92 +0.8 0 92 +0.8 0 116 min. 12 173.5 panel mounting bracket 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 1 + - 2 3 4 5 6 7 8 mv v ++ + - + - -- control output 1 (contact output, 4 to 20ma dc, ssr/ssc drive output) alarm output 1 alarm output 2 mv1-1 connection diagram panel cutout mv1-com time signal 1-4 output alarm 3-4 output or time signal 5-6 output status output pattern select input aux. analog output external command input trx-com trx1 trx2 a02 a01 a0-com alm3/ts5 di- reset di- run di- hold di- advance alm/ts-com di-2 3 di-2 2 di-2 1 di-2 0 di- com alm4 /ts6 input signal, power supply, 100 to 240v ac ts1 ts2 ts3 ts4 do-end do-com do- reset do- run/hold mv1-2 alm1 alm2 alm- com ac ac g pv rtd 250 ? (note) note:a resistor(250 ? 0.1%) should be used for 4 to 20ma dc input. tc sc 4~20ma a b outline diagram (unit:mm) scope of delivery
pvx information in this catalog is subject to change without notice. printed in japan head office 6-17, sanbancho, chiyoda-ku, tokyo 102-0075, japan http://www.fesys.co.jp/eng sales div. international sales dept. no.1, fuji-machi, hino-city, tokyo, 191-8502 japan phone: 81-42-585-6201, 6202 fax: 81-42-585-6187 http: //www.fic-net.jp/eng caution on safety *before using this product, be sure to read its instruction manual in advance.


▲Up To Search▲   

 
Price & Availability of EDS11-124D

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X