data sheet electronic transmitter with fieldbus fieldbus is a standard digital communication protocol between field instruments and upper control system. this fieldbus standa rd enables interactive communication among the number of i&c manufactures simultaneously and also the usage by exchanging fieldbus instruments. fcx-aii series electronic transmitters with foundation fieldbus and profibus is a fieldbus transmitters utilizing a unique micromachined capacitance silicon sensor with state-of -the-art microporcessor technology and converting the signal of silicon sensor to fieldbus protocol. this fieldbus transmitter can provide many merits of fieldbus as shown in the following ?eatures? features 1. fuji original ic ?rontier-1+ fieldbus ic ?rontier-1+?the original fieldbus interface controller ic, developed by fuji electric based on iec fieldbus physical layer specification, is installed in fcx-aii (fieldbus ver- sion.). 2. interoperability fcx-aii transmitter comply with the latest foundation fieldbus specification and profibus-pa specification and provide full interactive interoperability to other transmit- ters. in addition, foundation fieldbus fcx-aii transmitters are certified and registered by itk4.0, the latest standard for interoperability testing. 3. reduction of wiring cost the reduction of wiring cost of instrumentation is realizing due to multi-drop wiring of fieldbus instruments comparing to the current instruments. 4. high accuracy, high stability and high reliability high resolution data transmission with digital communica- tion lead high accuracy, high stability and high reliability. 5. abundant alarm functions and self-diagnosis abundant alarm and maintenance function defined in fieldbus specification in addition to process data can be well supported. the self-diagnosis including failure of pressure sensor, ab- normal of temperature etc. are also provided. date EDSX5-85D jul. 31, 2007
2 model configuration differential pressure/flow transmitter [model : fdc] (standard version and hydroseal diaphragm version) pressure transmitter [type : fdg] (standard version and hydroseal diaphragm version) absolute pressure transmitter [model : fda] remote seal type differential pressure/flow transmitter [model : fdd] level transmitter [model : fde] remote seal type pressure transmitter [model : fdb] reference page reference page reference page common specifications individual specifications code symbols outline diagram common specifications individual specifications code symbols outline diagram common specifications individual specifications code symbols outline diagram reference page reference page reference page common specifications individual specifications code symbols outline diagram common specifications individual specifications code symbols outline diagram common specifications individual specifications code symbols outline diagram 4 5 11 31 4 7 15 35 4 7 19 38 4 6 13 33 4 7 17 36 4 8 21 39 3 small frange type level transmitter [model : fdy] small frange remote seal type differential pressure/flow transmitter [model : fdx] small frange remote seal type pressure transmitter [model : fdw] reference page reference page reference page common specifications individual specifications common specifications individual specifications code symbols outline diagram code symbols outline diagram common specifications individual specifications code symbols outline diagram 4 8 4 9 25 43 23 41 4 9 27 46 4 model fdc, fdg, fda fde, fdy (lp side) fde, fdy (hp side) fdb, fdd, fdw, fdx process connections 1 / 4 -18npt or rc 1 / 4 on 54mm centers, as specified. meets din 19243. ansi, din or jis raised face frange. see code symbols of each model (5th digit). model fdc, fdg, fda fde, fdy fdb, fdd, fdw, fdx process connections on 60.5mm (jis 50a) pope using mounting or direct wall mounting. direct process mounting. fdb, fdd ? ? ? ? ? ? ? fdw, fdx, fdy ? ? ? ? ? ? ? ? ? ? ? optional specifications varies with model or material. so refer to code symbols. indicator: an optional 5-digit lcd meter with engi- neering unit is also available. oxygen service: special cleaning procedures are followed throughout the process to maintain all process wetted parts oil-free. the fill fluid is fluorinated oil. chlorine service: the fill fluid is fluorinated oil. degreasing: process-wetted parts are cleaned, but the fill fluid is standard silicone oil. not for use on oxygen or chlorine measure- ment. specifications (1) common specifications function and performance service: liquid, gas, and vapour output signal: digital signal based on fieldbus foun- dation protocol or profibus-pa. power supply: transmitter operates on 9v to 32v dc at transmitter terminals. quiescent draw current: 16 2ma standard: transmission cycle (macro cycle): foundation fieldbus profibus-pa fieldbus foundation specification(h1). (basic device, device type 113, ai function block) profibus profile. order no.3042 profibus-pa version 3.0 hazardous locations: foundation fieldbus profibus-pa 250ms min. 250ms fix. zero/span adjustment: zero and span are adjustable from the host system. zero is also adjustable ex- ternally from the adjustment screw. indication: none or 5-digit lcd meter, as specified. burnout direction: selectable from the host system. if self-diagnostic detect transmitter fail- ure, the output will be driven to either ?utput hold? ?utput overscale?or ?utput underscale?modes. temperature limit: ambient: 40 to +85 c (?0 to +80 c for lcd indicator) ( 40 to +60 c for arrester option) (?0 to +60 c for fluorinated oil filled transmitters) (?0 to +85 c for silicone oil ?, s, k? (+20 to +85 c for silicone oil ?, t? ambient: 15 to +65 c (?5 to +60 c for arrester option) (?0 to +60 c for fluorinated oil filled transmitter) (?0 to +60 c for silicone oil ?, s? for explosionproof units (flameproof or intrinsic safety), ambient tempera- ture must be within the limits speci- fied in each standard. process: see individual specifications storage: 40 to +90 c (fdw, fdx, fdy ? 40 to +70 c) atex ex ii2 gd -eexd iic t5/t6 factory class i ii iii mutual div. 1 groups b thru. g csa class i ii iii div. 1 groups c thru. g jis ex do iib+h 2 t4 authorities flameproof note ex iaiic t4 fisco (approval pending) ? ? ? ? ? ? ? ? ? ? ? humidity limit: 0 to 100% rh dielectric strength: 500v ac, 50/60hz 1 min., between cir- cuit and earth. insulation resistance: more than 100m ? at 500v dc. structure and material electrical connections: g1/2, 1/2-14 npt, pg13.5, or m20 1.5 conduit, as specified. and 1 conduit or 2 conduits, as specified. process connections: process-wetted parts material: see code symbols of each model (7th digit) non-wetted parts material: electronics housing: low copper die-cast aluminum alloy finished with polyes- ter coating (standard), or 316 stainless steel (scs14 per jis g5121), as speci- fied. bolts and nuts: cr-mo alloy (standard), 304 stainless steel or 630 stainless steel, as specified. see code symbols of each model. fill fluid: silicone oil (standard) or fluori- nated oil (daifloil) mounting bracket: 304 stainless steel environmental protection: iec ip67 and nema 6/6p mounting: 5 nace specification: metallic materials for all pressure bound- ary parts comply with nace mr-01-75. astm b7m or l7m bolts and 2hm nuts (class ii) are available. static pressure rating for code ??(16 mpa) is degraded to 10mpa. vacuum service: special silicone oil and filling procedure are applied. see fig. 1. optional tag plate: an extra stainless steel tag with cus- tomer tag data is wired to the transmit- ter. coating of cell: cell? surface is finished with epoxy/ polyurethane double coating. specify if environment is extremely corrosive. accessories oval flanges: (model ffp, refer to data sheet no. eds6-10) converts process connection to 1 / 2 -14 npt or to rc 1 / 2 ; in carbon steel or in 316 stainless steel. equalizing valves: (model ffn, refer to data sheet no. eds6-10) available in carbon steel or in 316 stain- less steel and in pressure rating 16mpa or 42mpa. ck ck (m4 screws) do not connect. field bus connection diagram (2) individual specifications zero-based spans, reference conditions, silicone oil fill, ss316 iso- lating diaphragms, output in linear mode, digital trim values equal to the span setpoints and capillary length of 1.5m. diffential pressure / flow transmitter : fdc static pressure, range limit: fd c 11 fd c 22 fd c 23 fd c 25 fd c 26 fd c 33 fd c 35 fd c 36 fd c 38 fd c 43 fd c 45 fd c 46 fd c 48 ?.1 to + 3.2 ?.1 to + 10 ?.1 to + 16 ?.1 to + 42 ?.1 to + 30 +/ 1 +/ 6 +/ 32 +/ 130 +/ 500 +/ 32 +/ 130 +/ 500 +/ 3000 +/ 32 +/ 130 +/ 500 +/ 3000 type range limit [kpa] static pressure [mpa] over range limit: to maximum static pressure limit process temperature and negative pressure tolerance limit: (for details, see fig. 1) filled oil 13th code process negative pressure temperatuer tolerance limit silicone oil (*1) y, g, n ?0 to +120 c 2.7 kpa abs fluorinated oil w, a, d ?0 to +80 c atmospheric pressure silicone oil r ?5 to +120 c 2.7 kpa abs lower limit of static pressure (vacuum limit): silicone oil filled sensor: see fig. 1 fluorinated oil filled sensor: 66kpa abs (500mmhg abs) at temperature below 60 c accuracy rating: (including linearity, hysteresis, and re- peatability) reference conditions, silicone oil fill, 316ss isolating diaphragms. max span above 32kpa model: for spans greater than 1/10 of url: 0.07% of span for spans below 1/10 of url: max span 1kpa, 6kpa model: for spans greater than 1/10 of url: 0.1% of span for spans below 1/10 of url: stability: 0.1% of upper range limit (url) for 3 years temperature effect: effects per 28 c change between the limits of ?40 c and +85 c static pressure code (5th digit in code symbols) ??/ 1kpa sensor ??/ 6kpa sensor ? ? ? 0.3% / 1mpa 0.1% / 3.2mpa 0.1% /10mpa 0.1% /16mpa 0.25% /42mpa zero shift (% of url) static pressure code (5th digit in code symbols) ??/1kpa sensor ??/6kpa sensor ? ? ? span shift zero shift (% of url) 0.05%/10mpa ?.2% /10mpa 0.2% / 1mpa ?.2% /3.2mpa 0.2% / 3.2mpa ?.2% /3.2mpa mounting position effect: zero shift, less than 0.12kpa for a 10 tilt in any plane. no effect on span. this error can be corrected by adjusting zero. mass{weight}: transmitter approximately 4.4kg without options. overrange effect: static pressure effect: 0.1 url span 0.02+0.05 % of span ( ) 0.1 url span 0.05+0.05 % of span () range code (6th digit in code symbols) ??1kpa max. span ??6kpa max. span ??32kpa max. span ??130kpa max. span ??500kpa max. span ??3000kpa max. span zero shift 0.225% 0.25% 0.0875% 0.1075% total effect 6 diffential pressure / flow transmitter hydroseal diaphragm version: fdc over range limit: to maximum static pressure limit process temperature and negative pressure tolerance limit: (for details, see fig. 1) filled oil 13th code process negative pressure temperatuer tolerance limit silicone oil y, g, n ?0 to +120 c 2.7 kpa abs fluorinated oil w, a, d ?0 to +80 c atmospheric pressure silicone oil r ?5 to +120 c 2.7 kpa abs static pressure, range limit: fdc 33 ?.1 to 16 +/? 32 fdc 35 ?.1 to 16 +/?130 type static pressure [mpa] range limit [kpa] lower limit of static pressure (vacuum limit): silicone oil filled sensor: see fig. 1 fluorinated oil filled sensor: 66kpa abs (500mmhg abs) at temperature below 60 c accuracy rating: (including linearity, hysteresis, and re- peatability) reference conditions, silicone oil fill, 316ss isolating diaphragms. for spans greater than 1/10 of url: 0.15% of span for spans below 1/10 of url: stability: 0.15% of upper range limit (url) for 3 years temperature effect: effects per 28 c change between the limits of ?40 c and +85 c range code zero shift (% of url) (6th digit in code symbols) ? 1 % url / 16mpa ? 0.6 % url / 16mpa span shift zero shift (% of url) 0.15% /10mpa{100bar} 0.2% /10mpa{100bar} 0.175% 0.2% total effect zero shift process temperature and negative pressure tolerance limit: (for details, see fig. 1) filled oil 13th code process negative pressure temperatuer tolerance limit silicone oil y, g, n ?0 to +100 c 2.7 kpa abs fluorinated oil w, a, d ?0 to +80 c atmospheric pressure silicone oil r ?5 to +100 c 2.7 kpa abs lower limit of static pressure (vacuum limit): silicone oil filled sensor: see fig. 1 fluorinated oil filled sensor: 66kpa abs (500mmhg abs) at temperature below 60 c accuracy rating: (including linearity, hysteresis, and re- peatability) reference conditions, silicone oil fill, 316ss isolating diaphragms. max span below 10000kpa model: for spans greater than 1/10 of url: 0.07% of span for spans below 1/10 of url: max span 50000kpa model: for spans greater than 1/10 of url: 0.1% of span for spans below 1/10 of url: stability: 0.1% of upper range limit (url) for 3 years temperature effect: effects per 28 c change between the limits of ?40 c and +85 c zero shift: 0.0875% total effect: 0.1075% overrange effect: zero shift; 0.2% of url for any overrange to maximum limit mounting position effect: zero shift, less than 0.1kpa for a 10 tilt in any plane. no effect on span. this error can be cor- rected by adjusting zero. mass{weight}: transmitter approximately 3.4kg without options. pressure transmitter : fdg range and overrange limit: fdg 01 fdg 02 fdg 03 fdg 04 fdg 05 type overrange limit [mpa] 1 1.5 9 15 75 range limit [kpa] 130 500 3000 10000 50000 lower limit upper limit permissible negative pressure limit pressure transmitter hydroseal diaphragm version: fdg process temperature and negative pressure tolerance limit: (for details, see fig. 1) static pressure, range limit: lower limit of static pressure (vacuum limit): silicone oil filled sensor: see fig. 1 fluorinated oil filled sensor: 66kpa abs (500mmhg abs) at temperature below 60 c accuracy rating: (including linearity, hysteresis, and re- peatability) reference conditions, silicone oil fill, 316ss isolating diaphragms. for spans greater than 1/10 of url: 0.15% of span for spans below 1/10 of url: 1.5 9 15 fdg 07 fdg 08 fdg 09 range limit [kpa] permissible negative pressure limit 500 3000 10000 upper limit lower limit ?.1 to 0.5 ?.1 to 3 ?.1 to 10 static pressure [mpa] over range limit [mpa] type mounting position effect: zero shift, less than 0.12kpa for a 10 tilt in any plane. no effect on span. this error can be corrected by adjusting zero. mass{weight}: transmitter approximately 4.4kg without options. overrange effect: static pressure effect: ( ) 0.1 url span 0.1+0.05 % of span () 0.1+0.05 % of span 0.1 x url span 0.1 url span 0.05+0.05 % of span ( ) 0.1 url span 0.02+0.05 % of span ( ) filled oil 13th code process negative pressure temperatuer tolerance limit silicone oil y, g, n ?0 to +100 c 2.7 kpa abs fluorinated oil w, a, d ?0 to +80 c atmospheric pressure 7 process temperature and negative pressure tolerance limit: process temperature; ?0 to +85 c negative pressure; depends on measur- ing range. accuracy rating: (including linearity, hysteresis, and re- peatability). reference conditions, silicone oil fill, 316ss isolating diaphragms. (standard) for spans greater than 1/10 of url: 0.2% of span for spans below 1/10 of url: (option) (code: 21th digit h) (not available for max span 16kpa abs, 130kpa abs) for spans greater than 1/10 of url: 0.1% of span for spans below 1/10 of url: stability: 0.2% of upper range limit (url) for 3 years temperature effect: effect per 28 c change between the lim- its of 40 c and +85 c zero shift: 0.225% total effect: 0.25% overrange effect: zero shift; 0.2% of url for any overrange to maximum limit mounting position effect: zero shift, less than 0.1kpa for a 10 tilt in any plane. no effect on span. this error can be cor- rected by adjusting zero. mass{weight}: transmitter approximately 3.4kg without options. absolute pressure transmitter : fda range and overrange limit: fda 01 fda 02 fda 03 fda 04 overrange limit [mpa] type 0.5 0.5 1.5 9 range limit [kpa abs] 0 to +16 0 to +130 0 to +500 0 to +3000 filled oil 13th code process negative pressure temperatuer tolerance limit fluorinated oil w, a, d ?0 to +120 c atmospheric pressure silicone oil h ?5 to +250 c j 85 to +300 c y, g ?0 to +120 c 2.7 kpa abs s ?5 to +250 c t 85 to +300 c k ?5 to +150 c 0.13 kpa abs level transmitter : fde static pressure, range limit: fde 3 fde 5 fde 6 +/?32 +/?130 +/?500 static pressure ? ? ? up to flange rating type range limit [kpa] over range limit: to maximum static pressure limit process temperature and negative pressure tolerance limit: (for details, see fig. 2, fig. 3) lower limit of static pressure (vacuum limit): silicone oil filled sensor: see fig. 1 fluorinated oil filled sensor: 66kpa abs (500mmhg abs) at temperature below 60 c low pressure side contact liquid temperature on transmitter of code ?, j, s, t?is 120 c or lower. low pressure side contact liquid temperature of code ??is 85 c or lower. remote seal type diffential pressure / flow transmitter: fdd accuracy rating: (including linearity, hysteresis, and re- peatability) reference conditions, silicone oil fill, 316ss isolating diaphragms. (standard) for spans greater than 1 /10 of url: 0.2% of span for spans below 1 /10 of url: (option) (code: 21th digit h, k) for span greater than 1 /10 of url: 0.1% of span for span below 1 /10 of url: stability: 0.2% of upper range limit (url) for 3 years temperature effect: effects per 28 c change between the limits of ?40 c and + 85 c (standard) zero shift: 0.35% of url total effect: 0.5% of url (option) (code: 21th digit j, k) zero shift: 0.3% of url total effect: 0.4% of url static pressure effect: zero shift: 0.2% of url / 1mpa span shift: ?0.2% of calibrated span / 1mpa overrange effect: zero shift; 0.1% of url for flange rat- ing pressure mounting position effect: zero shift, less than 0.3kpa for a 10 tilt in any plane. (no extension) no effect on span. this error can be corrected by adjusting zero. mass{weight}: transmitter approximately 13kg without options. static pressure, range limit: fdd 3 fdd 5 fdd 6 +/?32 +/?130 +/?500 static pressure ? ? ? up to flange rating type range limit [kpa] 0.1+0.1 % of span 0.1 url span ( ) 0.05+0.05 % of span 0.1 url span ( ) 0.1+0.1 % of span 0.1 url span ( ) 0.05+0.05 % of span 0.1 url span ( ) stability: 0.15% of upper range limit (url) for 3 years temperature effect: effects per 28 c change between the limits of ?40 c and +85 c zero shift: 0.2% total effect: 0.225% overrange effect: zero shift; 0.4% of url for any overrange to maximum limit mounting position effect: zero shift, less than 0.1kpa for a 10 tilt in any plane. no effect on span. this error can be cor- rected by adjusting zero. mass {weight}: transmitter approximately 3.4kg without options. 8 remote seal type pressure transmitter: fdb process temperature and negative pressure tolerance limit: (for details, see fig. 2, fig. 4) range, and overrange limit: accuracy rating: (including linearity, hysteresis, and re- peatability) reference conditions, silicone oil fill, 316ss isolating diaphragms. (standard) for spans greater than 1/10 of url: 0.2% of span for spans below 1/10 of url: (option) (code; 21th digit h,k) not available for max span 50000kpa model. for spans greater than 1/10 of url: 0.1% of span for spans below 1/10 of url: stability: 0.1% of upper range limit (url) for 3 years temperature effect: effect per 28 c change between the lim- its of 40 c and +85 c (standard) zero shift: 0.35% of url total effect: 0.5% of url (option) (code; 21th digit j,k) zero shift: 0.3% of url total effect: 0.4% of url overrange effect: zero shift; 0.2% of url for any overrange to maximum limit mass {weight}: transmitter approximately 10kg without options. filled oil 13th code process negative pressure temperatuer tolerance limit fluorinated oil w, a, d ?0 to +120 c atmospheric pressure silicone oil h ?5 to +250 c j 85 to +300 c y, g ?0 to +120 c 2.7 kpa abs s ?5 to +250 c t 85 to +300 c k ?5 to +200 c 0.13 kpa abs small frange level transmitter : fdy static pressure, range limit: over range limit: to maximum static pressure limit process temperature and negative pressure tolerance limit: (for details, see fig. 2) filled oil 13th code process negative pressure temperatuer tolerance limit fluorinated oil w, a, d ?0 to +80 c atmospheric pressure silicone oil h 0 to +250 c y, g ?0 to +120 c 2.7 kpa abs s 0 to +250 c lower limit of static pressure (vacuum limit): silicone oil filled sensor: see fig. 1 fluorinated oil filled sensor: 66kpa abs (500mmhg abs) at temperature below 60 c accuracy rating: (including linearity, hysteresis, and re- peatability) reference conditions, silicone oil fill, 316ss isolating diaphragms. (standard) for spans greater than 1 /10 of url: 0.25% of span for spans below 1 /10 of url: (option) (code: 21th digit h, k) for spans greater than 1 /10 of url: 0.1% of span for span below 1 /10 of url: low pressure side contact liquid temperature on transmitter of code ?, s?is 120 c or lower. fdb 1 fdb 2 fdb 3 fdb 4 fdb 5 1 1.5 9 15 75 ?00 to +130 ?00 to +500 ?00 to +3000 ?00 to +10000 ?00 to +50000 type overrange limit [mpa] range limit [kpa] +/?130 +/?500 static pressure up to flange rating ? ? ? type fdy 5 fdy 6 range limit [kpa] 0.17+0.08 % of span 0.1 x url span () () 0.05+0.05 % of span 0.1 x url span 0.1+0.1 % of span 0.1 url span () 0.05+0.05 % of span 0.1 url span () accuracy rating: (including linearity, hysteresis, and re- peatability) reference conditions, silicone oil fill, 316ss isolating diaphragms. (standard) for spans greater than 1 /10 of url: 0.2% of span for spans below 1 /10 of url: (option) (code; 21th digit h,k) for spans greater than 1 /10 of url: 0.1% of span for spans below 1 /10 of url: stability: 0.2% of upper range limit (url) for 3 years temperature effect (*): effects per 28 c change between the limits of ?40 c and +85 c (standard) zero shift: 0.35% of url total effect: 0.5% of url (option) (code; 21th digit j,k) zero shift: 0.3% of url total effect: 0.4% of url note: * excluding effect by temperature difference between the seals. static pressure effect: zero shift; 0.2% of url for flange rating pressure span shift: ?0.2% of calibrated span for flange rating pressure overrange effect: zero shift; 0.1% of url for flange rating pressure mass {weight}: transmitter approximately 15kg without options. 0.1+0.1 % of span 0.1 url span ( ) 0.05+0.05 % of span 0.1 url span ( ) over range limit: to maximum static pressure limit process temperature and negative pressure tolerance limit: (for details, see fig. 2, fig. 4) filled oil 13th code process negative pressure temperatuer tolerance limit fluorinated oil w, a, d ?0 to +120 c atmospheric pressure silicone oil h ?5 to +250 c j +85 to +300 c y, g ?0 to +120 c 2.7 kpa abs s ?5 to +250 c t +85 to +300 c k ?5 to +200 c 0.13 kpa abs 9 filled oil 13th code process negative pressure temperatuer tolerance limit fluorinated oil w, a, d ?0 to +120 c atmospheric pressure silicone oil h 0 to +250 c y, g ?0 to +120 c 2.7 kpa abs s 0 to +250 c over range limit: to maximum static pressure limit process temperature and negative pressure tolerance limit: (for details, see fig. 2, fig. 4) small frange remote seal type differential pressure transmitter: fdx accuracy rating: (including linearity, hysteresis, and re- peatability) reference conditions, silicone oil fill, 316ss isolating diaphragms. (standard) for spans greater than 1 /10 of url: 0.25% of span for spans below 1 /10 of url: (option) (code; 21th digit h,k) for spans greater than 1 /10 of url: 0.1% of span for spans below 1 /10 of url: stability: 0.2% of upper range limit (url) for 3 years temperature effect: effects per 28 c change between the limits of ?15 c and +65 c zero shift: 0.5% total shift; 0.75% filled oil 13th code process negative pressure temperatuer tolerance limit fluorinated oil w, a, d ?0 to +120 c atmospheric pressure silicone oil h 0 to +250 c y, g ?0 to +120 c 2.7 kpa abs s 0 to +250 c process temperature and negative pressure tolerance limit: (for details, see fig. 2) small frange remote seal type pressure transmitter: fdw range, and overrange limit: accuracy rating: (including linearity, hysteresis, and re- peatability) reference conditions, silicone oil fill, ss316 isolating diaphragms. (standard) for spans greater than 1/10 of url: 0.25% of span for spans below 1/10 of url: (option) (code; 21th digit h) for spans greater than 1/10 of url: 0.1% of span for spans below 1/10 of url: stability: 0.2% of upper range limit (url) for 3 years temperature effect: effect per 28 c change between the lim- its of 15 c and +65 c zero shift: 0.5% total shift; 0.75% where, url: maximum span (upper range limit) note : above specifications are based on the con- ditions that flange and sensor unit are at the same temperature and in the same level. if temperature is different at flange, capillary or sensor unit, output variation may increase. overrange effect: zero shift; 0.2% of url/(1.5 x url) mass {weight}: transmitter approximately 10kg without options. static pressure, range limit: static pressure effect: zero shift: 0.2% of url/1mpa span shift: ?.2% of calibrated span /1mpa overrange effect: zero shift; 0.1% of url for flange rat- ing pressure mass{weight}: transmitter approximately 13kg without options. up tp flange rating fdx 5 fdx 6 +/?130 +/?500 type range limit [kpa] static pressure } fdw 3 ?00 to +3000 4.5 fdw 4 ?00 to 10000 15 type overrange limit [mpa] range limit [kpa] () 0.17+0.08 % of span 0.1 x url span () 0.05+0.05 % of span 0.1 x url span 0.17+0.08 % of span 0.1 x url span () () 0.05+0.05 % of span 0.1 x url span (option) (code: 21th digit j, k) zero shift; 0.5% total shift; 0.75% where, url: maximum span (upper range limit) static pressure effect: zero shift; 0.2% of url/1mpa (10 bar) span shift: 0.2% of calibrated span / 1mpa overrange effect: zero shift; 0.1% of url for flange nomi- nal pressure mass {weight}: transmitter approximately 15kg without options. (option) (code; 21th digit j,k) zero shift: 0.5 total shift; 0.75% where, url: maxi mum span (upper range limit) note : above specifications are based on the con- ditions that flanges and sensor unit are at the same temperature and in the same level. if temperature is different at flanges, capillary or sensor unit, output variation may increase. stability: 0.2% of upper range limit (url) for 3 years temperature effect: effects per 28 c change between the limits of ?15 c and + 65 c zero shift; 0.5% total shift; 0.75% 10 ?0 60 ?5 85 120 none-operating area 2.7 4 20 operating pressure process temperature[ c ] 101 [kpa abs] silicone oil (code:y,g,n) silicone oil (code:r) operating area 101 53.3 13.3 2.7 [kpa abs] ?0 ?5 60 85 120 200 230250 300 [ c] filled fluid: silicone oil (code y, g) filled fluid: silicone oil (code t) filled fluid: silicone oil (code s) operating pressure operating area non-operating area process temperature 101 0.27 0.13 [kpa abs] 200 ?5 100 [ c] filled fluid: silicone oil (code k) operating pressure operating area non- operating area process temperature fig. 1 relation between process temperature and operating pressure (pressure and differential pressure/flow transmitters) fig. 2 relation between process temperature and operating pressure (remote seal type pressure, remote seal type differential pressure and level transmitters) fig. 4 relation between process temperature and operating pressure (remote seal type pressure, remote seal type differential pressure and level transmitters) fig. 3 relation between process temperature and operating pressure (level transmitters) operating arear non-operating area 101 {1010} 0.13 {1.3} [kpa abs] {mbar abs} operating pressure ?5 100 process temperature[ c ] sealing liquid:silicone (code k) 11 code symbols diffential pressure / flow transmitter : fdc a b c d e s t v w x description note note 1 note 1 note 1 note 1 note 2 note 3 note 3 digit 4 5, 6, 7 12 description note note 9 note 4 note 8 note 5 note 6 note 7 digit 9 10 11 12 13 14 15 4567 123 f4 dc 89 10 11 12 13 14 15 digit no. of code note 1: (*1) the thread is m12, if 42mpa {420bar} static pressure is specified. note 2: (*2) 100: 1 turn down is possible, but should be used at the span greater than 1 /40 of the maximum span for better performance. note 3: (*3) the diaphragm face is coated with gold and ceramic. note 4: (*4) customer tag number can be engraved on standard stainless steel name plate. if extra tag plate is required, select ?es? note 5: (*5) static pressure should be ?.1 to +10mpa{? to +100bar}. note 6: (*6) available for 5th digit code ?? ?? ?? in case of stainless steel bolt with 5th digit code ?? static pressur e should be ?.1 to +10mpa {? to + 100bar}. note 7: (*7) available for 5th digit code ?? ?? note 8: (*8) in case of tropical use, select stainless bolts and nuts. note 9: (*9) in case of 10th code is ??atex, fisco), then the 9th code, e, s, v and w (with arrester option) are not available. a b c d e x k f 4 a c d f y b c e m n p q y w g a d n r a e p s r v t w a b c d e f a b (*5) (*6) (*7) specify ??or ??for the 7th digit code ?? ?? or ? (*4) 13 pressure transmitter : fdg 14 description note note5 note3 note4 digit 10 11 12 13 14 15 15 absolute pressure transmitter : fda description note note1 note4 note2 digit 4 6, 7 16 description note note 3 digit 13 14 15 21 17 level transmitter : fde a b c d e s t v w x hp side lp side 0 1 2 3 4 5 6 7 8 9 m r a b c d e f g h j k s t u v w x 3 5 6 v c d e j h m t b l u p r diaphragm 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel hastelloy-c monel tantalum hastelloy-c monel tantalum 316 stainless steel 316 stainless steel diaphragm and flange face 316 stainless steel hastelloy-c monel tantalum diaphragm: 316l stainless steel +au coating flange face: 316 stainless steel hastelloy-c monel tantalum hastelloy-c monel tantalum titanium zirconium wetted sensor body 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel hastelloy-c lining monel lining tantalum lining hastelloy-c lining monel lining tantalum lining 316 stainless steel 316 stainless steel 18 19 remote seal type differential pressure transmitter : fdd 20 21 remote seal type pressure transmitter : fdb description note note 2 note 1 note 3 note 4 digit 4 5 6 7 22 description note note 10 note 5 note 5 note 5 note 5 note 5 note 5 note 5 note 6 note 6 note 6 note 6 note 5 note 5 note 5 note 7 note 8 note 9 digit 10 11 12 13 14 15 21 23 small frange type level transmitter : fdy diaphragm & flange face 316 stainless steel diaphragm: 316l stainless steel +au coating hastelloy-c monel tantalum flange face: 316 stainless steel hastelloy-c monel tantalum hastelloy-c monel tantalum 0 1 2 3 4 5 a b c d g h j k l m q r s t 5 6 v j c d e h m t b l u a b c d e s t v w x hp side lp side description note note1 digit 4 5 6 7 9 24 y b c e m n p q y a b c d y w g a d h s a b c d a b e (11th digit code ??only) (13th digit code ?? ??are not available.) description note digit 10 11 12 13 14 15 21 25 small frange remote seal type differential pressure transmitter : fdx 26 27 small frange remote seal type pressure transmitter : fdw 28 29 30 ordering information when ordering this instrument, specify: 1. code symbols 2. calibration range (xd_scale) and unit (cal_unit) unless specified, the range is maximum span. 3. output scale and unit (out_scale) ?unless specified, the scale is the same as the calibration range. 4. output mode (l_type) select any of direct/indirect linear/indirect sort. unless otherwise specified, q in case of output scale in flow rates indirect sort (extraction output) w in case of other units indirect linear (proportional output) 5. low flow rate cut point (specify only when needed for flow measurement) specify in percentages of output scale 6. output orientation (burnout direction) when abnormal- ity is occurred in the transmitter. select hold / overscale / underscale. unless specified, output hold function is supplied. 7. setting of external zero adjustment sw select either of ?alid?and ?nvalid unless otherwise specified, ?alid?is selected. 8. tag no. up to 26 alphanumerical characters. unless otherwise specified, the tag no. is efb- 002 (but, not stamped). 9. node address (if required) unless specified, ? f0?foundation fieldbus), ? 03?profibus) 10. display scale and unit (specify only for the transmitter with a digital indicator) for the settable range, contact fuji electric co. ltd. no low flow cut is performed unless otherwise specified, it conforms to the out- put scale. 31 outline diagram of each standard model (unit:mm) differential pressure / flow transmitter : fdc < 7th digit code without : b, l, u > note 1) cable gland is supplied in case of flameproof packing type. 11 cable is suitable. note 2) the pressure connector is located on the down side surface of the detector, when the vent /drain plug is attatched on the upper side of the detector. conduit conn. press. conn. def h oval flange screw g 1 /2 17 8 rc 1 /4 7 /16 -20unf screw depth 15 a, s 1 /2 -14npt 16 5 1 /4 -18npt 7 /16 -20unf screw depth 15 b, t pg13.5 84.5 1 /4 -18npt m10 screw depth 15 c, v pg13.5 84.5 1 /4 -18npt 7 /16 -20unf screw depth 15 e, x 4th digit of the code symbols m20 1.5 16 5 1 /4 -18npt m10 screw depth 15 d, w ck ck connection diagram (m4 screws) do not connect. field bus electronics unit sensor unit 70 104 41.3 54 154 59 43 231 17 g 1 /2 ?3 d e f ?5 h ? 38 58 37 237 70 80 105 123 52.5 88 120 130 43.5 ?0 mtg. pipe jis 50a (2b) u-bolt m8 ??press. conn. zero adj. screw fastener (flameproof only) cable gland (option) ??conduit conn. ??conduit conn.1 ??conduit conn.2 vent/drain plug 4 holes 9 dia. detail ? detail ? 8 2.5 see table 1 see table 1 earth terminal oval flange screw see table 1 side vent (option) press.conn. (low pressure side) press.conn. (high pressure side) up down (10) (conduit conn.) detail ? (press. conn.) ?8.5 in case of 4th digit code ?,v,w,x vent/drain plug (when the vent/drain plug attatched on the upper side of the detector) 4-m8 12 note 1) note 2) table 1 32 differential pressure / flow transmitter : fdc < 7th digit code : b, l, u > 4-m8 12 17 g 1 /2 13 e f h 15 note 1) cable gland is supplied in case of 10th digit code ?? 11 cable is suitable. conduit conn. efh oval flange screw g 1 /2 17 8 7 /16 -20unf screw depth 10 a, s 1 /2 -14npt 16 5 7 /16 -20unf screw depth 10 b, t pg13.5 8 4.5 m10 screw depth 10 c, v m20 1.5 16 5 m10 screw depth 10 d, w pg13.5 8 4.5 7 /16 -20unf screw depth 10 e, x 4th digit of the code symbols connection diagram detail ? see table 1 detail ? (conduit conn.) detail ? (press. conn.) cable gland (option) note 1) 2 +0.2 +0.1 16 12 0 - 0.1 1 4 4 16 1 /4 -18npt 10 detail ? (press. conn) u-bolt m8 fastener (flameproof only) ??conduit conn. electronics unit press.conn. (high pressure side) mtg. pipe jis 50a (2b) ??or ??press. conn. oval flange screw see table 1 in case of 4th digit code ?,v,w,x zero adj. screw vent/drain plug ??conduit conn.1 ??conduit conn.2 4 holes 9 dia. earth terminal press.conn. (low pressure side) up down 240 40 58 38 70 234 41.3 70 104 80 120 80 186 91 43 105 52.5 88 (10) 54 sensor unit table 1 ck ck (m4 screws) do not connect. field bus 33 pressure transmitter : fdg < 7th digit code without : b, l, u > note1) cable gland is supplied in case of flamproof packing type. 11 cable is suitable. note2) the pressure connector is located on the down side surface of the detector, when the vent / drainplug is attatched on the upper side of the detector. conduit conn. press.conn. def h oval flange screw g 1 /2 17 8 rc 1 /4 7 /16 -20unf screw depth15 a, s 1 /2 -14npt 16 5 1 /4 -18npt 7 /16 -20unf screw depth15 b, t pg13.5 84.5 1 /4 -18npt m10 screw depth15 c, v m20 1.5 16 5 1 /4 -18npt m10 screw depth15 d, w pg13.5 84.5 1 /4 -18npt 7 /16 -20unf screw depth15 e, x 4th digit of the code symbols connection diagram h 7 38 58 37 237 216 (6th digital code ?? 70 80 105 123 52.5 88 104 130 43.5 80 154 59 43 27 70 104 231 210 (6th digit code ?? mtg. pipe jis 50a (2b) u - bolt m8 ??press. conn. zero adj. screw fastener (flameproof only) cable gland (option) ??conduit conn. ??conduit conn.1 ??conduit conn.2 vent/drain plug 4 holes 9 dia. detail ? detail ? 8 2.5 see table 1 earth terminal oval flange screw see table 1 side vent (option) up down (10) 41.3 54 (conduit conn.) detail ? (press. conn.) 18.5 in case of 4th digit code ?,v,w,x vent/drain plug (when the vent/drain plug attached on the upper side of the detector) 4-m8 12 note1) note2) table 1 17 g 1 /2 13 d e f 15 see table 1 electronics unit sensor unit ck ck (m4 screws) do not connect. field bus 34 pressure transmitter : fdg < 7th digit code : b, l, u > ck ck (m4 screws) do not connect. field bus note) cable gland is supplied in case of 10th digit code ?? 11 cable is suitable. conduit conn. def oval flange screw g 1 /2 17 8 7 /16 -20unf screw depth10 a, s 1 /2 -14npt 16 5 7 /16 -20unf screw depth10 b, t pg13.5 84.5 m10 screw depth10 c, v m20 1.5 16 5 m10 screw depth10 d, w pg13.5 84.5 7 /16 -20unf screw depth10 e, x 4th digit of the code symbols connection diagram 17 g 1 /2 13 e f h 15 38 58 40 240 70 80 105 52.5 88 104 43.5 80 155 60 43 70 104 234 mtg. pipe jis 50a (2b) u - bolt m8 in case of 4th digit code ?,v,w,x zero adj. screw fastener (flameproof only) cable gland (option) note) ??conduit conn. ??conduit conn.1 ??conduit conn.2 4 holes 9 dia. detail ? (conduit conn.) detail ? see table 1 earth terminal up down p 16 12 +0.2 +0.1 4 1 2 0 -0.1 4th digit code ?. s? oval flange screw see table 1 ??or ? press. conn. vent/drain plug view from p 98 4 16 1 /4 -18npt 10 (10) 41.3 54 4th digit code ?,c,d,e,t,v,w,x detail ? (press. conn.) detail ? 4-m8 12 table 1 electronics unit sensor unit 35 absolute pressure transmitter : fda note1) cable gland is supplied in case of flamproof packing type. 11 cable is suitable. note2) the pressure connector is located on the down side surface of the detector, when the vent / drainplug is attached on the upper side of the detector. conduit conn. press.conn. def h oval flange screw g 1 /2 17 8 rc 1 /4 7 /16 -20unf screw depth15 a, s 1 /2 -14npt 16 5 1 /4 -18npt 7 /16 -20unf screw depth15 b, t pg13.5 8 4.5 1 /4 -18npt m10 screw depth15 c, v pg13.5 8 4.5 1 /4 -18npt 7 /16 -20unf screw depth15 e, x 4th digit of the code symbols m20 1.5 16 5 1 /4 -18npt m10 screw depth15 d, w connection diagram ?8.5 38 58 37 237 70 ?0 105 123 52.5 88 104 43.5 ?0 155 60 43 27 70 120 231 mtg. pipe jis 50a (2b) u - bolt m8 in case of 4th digit code ?,v,w,x fastener (flameproof only) cable gland (option) note1) ??conduit conn. ??conduit conn.1 ??conduit conn.2 vent / drain plug 4 holes 9 dia. 17 g 1 /2 ?3 d e f ?5 h ? see table 1 see table 1 table 1 oval flange screw see table 1 up down (10) 41.3 50 8 2.5 ??press. conn. zero adj. screw detail ? datail ? (conduit conn.) (press. conn.) detail ? earth terminal side vent (option) vent/drain plug (when the nent/drain plug attached on the upper side of the detector) note2) 2-m8 12 electronics unit sensor unit ck ck (m4 screws) do not connect. field bus 36 level transmitter : fde < 7th digit code without : b, l, u > ? 185 210 210 240 191 229 210 254 200 220 ? 150 170 175 195 152.5 190.5 168 200 160 180 ? 126 151 126 151 126 151 126 151 126 151 ? 100 103 100 103 100 103 100 103 100 103 ? 73 96 73 96 73 96 73 96 73 96 t 38 38 48 52 44 44 49 52 44 40 n-? 8-19 8-19 8-23 8-25 4-20 8-20 8-23 8-23 8-18 8-18 (flange) jis-10k-100a jis-10k-80a jis-30k-80a jis-30k-100a ansi-150lb-3b ansi-150lb-4b ansi-300lb-3b ansi-300lb-4b din pn40 dn80 din pn16 dn100 200 160 126 100 73 42 8-23 jis-20k-80a 210 168 126 100 73 52 8-23 ansi-600lb-3b note 1) cable grand is suppled in case of flamproof packing type. 11 cable is suitable. note 2) the pressure connector is located on the down side surface of the detector, when the vent / detector. conduit conn. press.conn. kmn j oval flage screw g 1 /2 17 8 rc 1 /4 7 /16 -20unf screw depth15 a, s 1 /2 -14npt 16 5 1 /4 -18npt 7 /16 -20unf screw depth15 b, t pg13.5 8 4.5 1 /4 -18npt m10 screw depth15 c, v m20 1.5 16 5 1 /4 -18npt m10 screw depth15 d, w pg13.5 8 4.5 1 /4 -18npt 7 /16 -20unf screw depth15 e, x 4th digit of the code symbols y 50 100 150 200 9.5 ~ 13 10 ~ 17 10.5 ~ 17.5 11 ~ 18 11.5 ~ 18.5 0 a e b f c g d h 160 354 l2 l3 360 296 154 290 11th degit code mass apprpx. l (mm) (kg) l1 ck ck (m4 screws) do not connect. field bus ? ? ? ? ?0 l t 20 h.p. conn. ?3 k m n ?5 g 1 /2 17 detail ? detail ? j ?8.5 ? 8 2.5 detail ? ??conduit conn. 43.5 ? n holes h dia inner of gasket 48 43 41.3 143 oval flang screw see table 1 27 l3 flange : ansi/jpi -150lb-3b ??l.p. conn. up down vent / drain plug l2 ?0 52.5 88 zero adj.screw ??conduit conn.1 105 l1 (10) 59 (conduit conn.) (l.p conn.) see table 1 see table 1 table 1 in case of 4th digit code ?, v, w, x ??conduit conn.2 vent / drain plug (when the vent /drain plug attatched on the upper side of the detector) note 2) fastener (flameproof only) earth terminal sensor unit electronics unit cable gland (option) note 1) connection diagram 37 level transmitter : fde < 7th digit code : b, l, u > ?3 k m n ?5 g1/2 17 2 +0.2 +0.1 ?6 ?2 0 -0.1 1 ? ?6 1/4-18npt 10 detail ? (l.p. conn.) 4th digit code ? see table 1 20 l l3 t 40.5 ?0 52.5 88 (10) 41.3 107 105 91 43 186 46.4 inner of gasket connection diagram ? ? ? ? ? h.p. conn. sensor unit electronics unit earth terminal vent / drain plug ??conduit conn.1 l2 l1 fastener (flameproof only) n holes h dia ?0 cable gland (option) note 1) ??conduit conn. ??or ??l.p. conn. zero adj.screw in case of 4th digit code ?, v, w, x oval flange screw see table 1 up down detail ? (conduit conn.) detail ? detail ? (l.p conn.) conduit conn. kmn oval flage screw g 1 /2 17 8 7 /16 -20unf screw depth10 a, s 1 /2 -14npt 16 5 7 /16 -20unf screw depth10 b, t pg13.5 8 4.5 m10 screw depth10 c, v m20 1.5 16 5 m10 screw depth10 d, w pg13.5 8 4.5 7 /16 -20unf screw depth10 e, x 4th digit of the code symbols y 50 100 150 200 11.5 ~ 15 12 ~ 19 12.5 ~ 19.5 13 ~ 20 13.5 ~ 20.5 0 a e b f c g d h 150 344 l2 l3 350 286 144 290 11th degit code mass apprpx. l (mm) (kg) l1 table 1 note 1) cable grand is suppled in case of 10th digit code ?? 11 cable is suitable. flange : ansi/jpi -150lb-3b ? 185 210 210 240 191 229 210 254 200 220 ? 150 170 175 195 152.5 190.5 168 200 160 180 ? 126 151 126 151 126 151 126 151 126 151 ? 100 103 100 103 100 103 100 103 100 103 ? 73 96 73 96 73 96 73 96 73 96 t 38 38 48 52 44 44 49 52 44 40 n-? 8-19 8-19 8-23 8-25 4-20 8-20 8-23 8-23 8-18 8-18 (flange) jis-10k-100a jis-10k-80a jis-30k-80a jis-30k-100a ansi-150lb-3b ansi-150lb-4b ansi-300lb-3b ansi-300lb-4b din pn40 dn80 din pn16 dn100 200 160 126 100 73 42 8-23 jis-20k-80a 210 168 126 100 73 52 8-23 ansi-600lb-3b ck ck (m4 screws) do not connect. field bus 38 remote seal type differential pressure transmitter : fdd note) cable gland is supplied in case of flamproof packing type. 11 cable is suitable. conduit donn. jkm g 1 /2 17 8 a, s 1 /2 -14npt 16 5 b, t pg13.5 84.5 c, v m20 1.5 16 5 d, w 4th digit of the code symbols ? 185 210 210 240 191 229 210 254 200 220 ? 150 170 175 195 152.5 190.5 168 200 160 180 ? 126 151 126 151 126 151 126 151 126 151 ? 100 103 100 103 100 103 100 103 100 103 ? 73 96 73 96 73 96 73 96 73 96 t 38 38 48 52 44 44 49 52 44 40 p 116 141 116 141 116 141 116 141 116 141 n-? 8-19 8-19 8-23 8-25 4-20 8-20 8-23 8-23 8-18 8-18 (flange) jis-10k-100a jis-10k-80a jis-30k-80a jis-30k-100a ansi-150lb-3b ansi-150lb-4b ansi-300lb-3b 210 168 126 100 73 52 116 8-23 ansi-600lb-3b ansi-300lb-4b din pn40 dn80 din pn16 dn100 200 160 126 100 73 42 116 8-23 jis-20k-80a v,h,m,t,p,r a,f b,j c,k d,l 0 50 100 150 200 14~19.5 15~30.5 15.5~31 16~31.5 16.5~32 l mass. appox. (kg) 11th digit code d, q e,r l,s f,t s (m) 1.5 3 5 6 (m) s m,v n,w p,x 7 8 10 11th digit code 7th digit code connection diagram ck ck (m4 screws) do not connect. field bus p ?3 j k m ?5 g 1 /2 17 see table 1 table 1 ?0 270 48 43 earth tarminal 120 70 in case of 4th digit code ?,v,w n holes h dia. detail ? (conduit donn.) detail ? 222 s s h.p. l.p. cable gland (option) note) ??conduit conn. ? conduit conn. 1 ? ? l 20 t ? ?0 52.5 88 zero adj. screw 38 28 58 228 mtg. pipe jis 50a (2b) u-bolt m8 70 4 holes 9 dia. ? inner of gasket no flange is attached in case of 5th digit code ?, q ? 54 104 up down 105 (10) fastener (flamproof only) ? ??conduit conn.2 electronics unit sensor unit 39 remote seal type pressure transmitter : fdb note) cable gland is supplied in case of flamproof packing type. ?1 cable is suitable. connection diagram ? 191 210 200 220 185 210 150 175 152.5 168 160 180 ? 126 151 126 126 126 151 ? 100 103 100 100 100 103 ? 73 96 73 73 73 96 ? 38 38 44 52 44 40 t 116 141 116 116 116 141 p 8-19 8-19 4-20 8-23 8-18 8-18 n-? jis-10k-80a jis-10k-100a ansi-150lb-3b ansi-600lb-3b din pn40 dn80 din pn16 dn100 (flange) 210 170 126 100 73 48 116 8-23 jis-30k-80a 200 160 126 100 73 42 116 8-23 jis-20k-80a 229 190.5 151 103 96 44 141 8-20 ansi-150lb-4b 210 168 126 100 73 49 116 8-23 ansi-300lb-3b jkm g 1 /2 17 8 a, s 1 /2-14npt 16 5 b, t pg13.5 8 4.5 c, v m20 1.5 16 5 d, w conduit conn. table 1 4th digit of the code symbols 7th digit code l mass approx.(kg) 11th digit code s (m) 0 50 100 150 200 9.5 10.5 11.5 12 12.5 1.5 3 5 6 7 8 10 v h m r a f b j c k d l d q e r l s t f v m w n x p t p electronics unit sensor unit ck ck (m4 screws) do not connect. field bus ? ? l t ? ? p ?3 j k m ?5 g 1 /2 17 ?0 52.5 88 zero adj. screw 104 ?0 191 60 43 38 30 58 237 120 70 mtg. pipe jis 50a (2b) u - bolt m8 in case of 4th digit code ?,v,w 70 ??conduit conn.1 ??conduit conn.2 4 holes 9 dia. cable gland (option) note) up down ??conduit conn. n holes h dia. no flange is attached in case of 5th digit code ?, q ,r?. detail ? (conduit conn.) 231 s see table 1 20 ? inner of gasket 50 105 (10) detail ? (conduit conn.) fastener (flameproof only) earth terminal 2-m8 12 4 1 2 3 fdb 40 remote seal type pressure transmitter : fdb v4 4 5 fdb k connection diagram details of ? details of ? 15 d e see table 1 c 13 g1/2 17 ck ck (m4 screws) do not connect. field bus earth terminal (both side) see table 1 191 60 43 s 206 70 50 120 2?8x12 mtg. jis 50a (2b) u-bolt m8 70 38 30 58 4 holes 9 dia. 237 80 105 52.5 (10) 88 4th of code symbols ?, v, w type is attached zero/span adj. screw up down a conduit conn. with field ind. 20 100 18 53 45 2 g1 packing 23.6 ?.1 ?.2 30 fastener (flameproof model only) 104 80 *cable gland (option) b conduit conn. ?.1 ?.2 4th of code symbols s t v w c g1/2 1/2-14npt pg13.5 m20x1.5 conduit conn. d 17 16 8 16 e 8 5 4.5 5 earth terminal m4 no. 8-32unc m4 m4 table 1 note *: cable gland is supplied in case of flameproof packing type. 11 cable is suitable. 11th of code symbols d q 1.5 s (m) e r l s f t m v n w p x 3 5 6 7 8 10 41 small frange type level transmitter : fdy < 7th digit code without : b, l, u > ??l. p. conn. in case of frange with 4 bolt holes l2 l 20 41.3 t l3 l1 up down 88 ?8 ?9 ? 27 48 43 143 8 2.5 m k 17 ? ? 52.5 105 43.5 ?0 (10) ?0 l.p. conn. h.p. conn ? ?5 ?3 hj g 1 /2 ?8.5 inner of gasket sensor unit electronics unit zero adj. screw in case of 4th digit code ?, v, w, x vent / drain plug (when the vent / drain plug attatched on the upper side of the detector) note2) ??conduit conn.1 ??conduit conn.2 vent / drain plug cable grand (option) ??conduit conn. fastener (flameproof only) n holes h dia. oval flange screw see table 1 detail ? detail ? detail ? 5th digit of code symbols 11th digit of code symbols l [mm] l1 l2 l3 mass approx, [kg] ? ? 0, g 140 105 36 4-19 jis-10k-40a y 0 360 160 296 9.5 to 12 a 50 10 to 17 b 100 354 154 290 10.5 to 17.5 c 150 11 to 18 d 200 11.5 to 18.5 1, h 155 120 36 4-19 jis-10k-50a 2, j 140 105 39 4-19 jis-20k-40a 3, k 155 120 38 8-19 jis-20k-50a 4, l 160 120 42 4-23 jis-30k-40a 5, m 165 130 42 8-19 jis-30k-50a a, q 127 98.4 37.5 4-16 ansi/jpi-150lb-1 1 /2 b b, r 152 120.6 39.5 4-20 ansi/jpi-150-2b c, s 156 114.3 41 4-23 ansi/jpi-300lb-1 1 /2 b d, t 165 127 42.5 8-20 ansi/jpi-300lb-2b t n-? flange table 1 jkm h g 1 /2 17 8rc 1 /4 7 /16 -20unf screw depth15 a, s 1 /2 -14npt 18 5 1 /4 -18npt 7 /16 -20unf screw depth15 b, t pg13.5 8 4.5 1 /4 -18npt m10 screw depth15 c, v m20 1.5 16 5 1 /4 -18npt m10 screw depth15 d, w pg13.5 8 4.5 1 /4 -18npt 7 /16 -20unf screw depth15 e, x note) cable gland is supplied in case of flamproof packing type. 11 cable is suitable. connection diagram conduit conn. press.conn. oval flange screw 4th digit of the code symbols note) see table 1 ck ck (m4 screws) do not connect. field bus 42 small frange type level transmitter : fdy < 7th digit code : b, l, u > 41.3 12 ?6 ?5 j ?3 g 1 /2 16 4 1 /4 -18npt ?.2 +0.1 0 ?.1 150 350 88 52.5 115 10 ?0 h.p. conn 20 t 28 107 286 ?9 ? 40.5 91 1 10 43 186 km 17 2 ? ? details of ? 4th of code symbols ?, s?type details of ? 4th of code symbols ?, c, d, e, t, v, w, x?type in case of flange with 4 bolt holes ??or ? l. p. conn. oval flange screw see table 1 zero adj. screw in case of 4th digit code ?,v,w, x ??conduit conn. 1 ??conduit conn. 2 vent / drain plug inner of gasket detail ? detail ? earth terminal sensor unit electronics unit conduit conn. oval flange screw 4th digit of the code symbols connection diagram 5th digit of code symbols d see table 1 table 1 e 0, g 140 105 36 4-19 jis-10k-40a 1, h 155 120 36 4-19 jis-10k-50a 2, j 140 105 39 4-19 jis-20k-40a 3, k 155 120 38 8-19 jis-20k-50a 4, l 160 120 42 4-23 jis-30k-40a 5, m 165 130 42 8-19 jis-30k-50a a, q 127 98.4 37.5 4-16 ansi/jpi-150lb-1 1 /2 b b, r 152 120.6 39.5 4-20 ansi/jpi-150-2b c, s 158 114.3 41 4-23 ansi/jpi-300lb-1 1 /2 b d, t 165 127 42.5 8-20 ansi/jpi-300lb-2b tn- h flange jkm g 1 /2 17 8 7 /16 -20unf screw depth 10 a, s 1 /2 -14npt 16 5 7 /16 -20unf screw depth 10 b, t pg13.5 84.5 m10 screw depth 10 c, v m20 15 16 5 m10 screw depth 10 d, w pg13.5 84.5 7 /16 -20unf screw depth 10 e, x note) cable gland is supplied in case of 10th digit code ?? ?1 cable is suitable. up down 43.5 ?0 cable grand (option) ??conduit conn. fastener (flameproof only) n holes h dia. note) ck ck (m4 screws) do not connect. field bus 43 small frange remote seal type differential pressure transmitter : fdx inner of gasket 105 104 ?0 70 (10) 88 71 222 ?0 52.5 ?8 km 17 ?9 ?4 ? ? 38 58 228 20 270 48 43 70 2-m8 12 l.p. ss h.p. 120 62 lt 28 see table 1 j ?5 g 1 /2 ?3 note : in case of wafer type, flange is excluded from the scope of supply. mount flange, referring to the view. 71 ?9 ?4 20 mtg. pipe jis 50a (2b) u-bolt m8 in case of 4th digit code ?,v,w zero adj. screw 4 holes 9 dia. ??conduit conn. 1 fastene (flameproof only) cable gland (option) ??conduit conn. n holes h dia. no flange is attached in case of 5th digit code ?, x earth terminal detail ? detail ? 2-m6 screw depth 9 inner of gasket 44 small frange remote seal type differential pressure transmitter : fdx 45 small frange remote seal type differential pressure transmitter : fdx 46 small frange remote seal type pressure transmitter : fdw note) cable gland is supplied in case of flamproof packing type. ?1 cable is suitable. 7th digit of code symbols 11th digit of code symbols capillary length : s [mm] l 5th digit of code symbols 0,g 140 36 4-19 jis-10k-40a 105 1,h 155 36 4-19 jis-10k-50a 120 2,j 140 38 4-19 jis-20k-40a 105 3,k 155 38 8-19 jis-20k-50a 120 4,l 160 42 4-23 jis-30k-40a 120 5,m 165 42 8-19 jis-30k-50a 130 6,n 175 52 4-25 jis-63k-40a 130 7,p 185 54 8-23 jis-63k-50a 145 a, q 127 37.5 4-16 ansi/jpi-150lb-1 1 /2 b table 1 98.4 b,r 152 39.5 4-20 ansi/jpi-150lb-2b 120.6 c,s 156 41 4-23 ansi/jpi-300lb-1 1 /2 b 114.3 d,t 165 42.5 8-20 ansi/jpi-300lb-2b 127 e,u 156 42.5 4-23 ansi/jpi-600lb-1 1 /2 b 114.3 f,v 165 45.5 8-20 ansi/jpi-600lb-2b 127 ? ? ? n-? (flange) mass approx. [kg] v, h, m, t 0 9.5 a d, q 1500 e, r 3000 l, s 5000 50 10.5 b 100 11.5 c 150 12 d 200 12.5 jkm g 1 /2 17 8 a, s 1 /2 -14npt 16 5 b, t pg13.5 8 4.5 c, v m20 1.5 16 5 d, w conduit conn. 4th digit of the code symbols connection diagram ck ck (m4 screws) do not connect. field bus 2-m6 screw depth 9 inner of gasket 47 small frange remote seal type pressure transmitter : fdw small frange remote seal type pressure transmitter : fdw |
Price & Availability of EDSX5-85D |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |