Part Number Hot Search : 
CM150 IRF2903Z CY7C135 Z2PK206H CY7C135 DS2502T PCA4687B Z2PK206H
Product Description
Full Text Search
 

To Download EM-1RI Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  before installing this information is included as a quick reference installation guide. refer to the appropriate control panel installation manual for detailed system information. if the modules will be installed in an existing operational system, inform the operator and local authority that the system will be temporarily out of service. notice: this manual should be left with the owner/user of this equipment. general description relay module, model EM-1RI, is to be designed for use in activation of the types of products that are generally connected to an intelligent fire alarm sys - tem. it provides two sets of form c contacts that switch together (one dpdt relay). there is also an input that is capable of monitoring a dry set of contacts for open or closed conditions. the module also has on-board short circuit iso - lators to prevent shorts on the signaling line circuit from disabling more than one device on the intelligent loop. compatibility requirements to ensure proper operation, this module shall be connected to a listed compat - ible control panel. mounting the module mounts directly to 4-inch square electrical boxes. the box must have a minimum depth of 2 1 ? 8 inches. modules must be mounted with the ar - row facing upward for proper operation of the ir programming tool. surface mounted electrical boxes (smb500) are available from system sensor. ir receiver led indica to r c0166-00 d500-61-00 1 i56-2023-005 EM-1RI relay module specifications normal operating voltage: 15 to 30 vdc standby current: 580 a max. average (continuous broadcasts) alarm current: 2.0 ma (red led on) short circuit current, dry control input: 30 a max. average (5vdc) maximum resistance, dry contact input: 100 temperature range: 32f to 120f (0c to 49c) humidity: 10% to 93% rh non-condensing dimensions: 4.17? h 4.26? w 1.22? d; (106 mm h 108 mm w 31 mm d) accessories: wall cover plate (included); smb500 surface mount electrical box; cb500 control module barrier current rating maximum voltage load description application 3 a 30 vdc resistive non-coded 2 a 30 vdc resistive coded .9 a 110 vdc resistive non-coded .9 a 125 vdc resistive non-coded .5 a 30 vdc inductive (l/r=5ms) coded 1 a 30 vdc inductive (l/r=2ms) coded .3 a 125 vac inductive (pf=.35) non-coded 1.5 a 25 vac inductive (pf = .35) non-coded .7 a 70.7 vac inductive (pf=.35) non-coded 2 a 25 vac inductive (pf=.35) non-coded note: this module is not approved for use in the european union, at or above 50vac or 70vdc. wiring note: all wiring must conform to applicable local codes, ordinances, and regulations. 1. install module wiring in accordance with the job drawings and appropri - ate wiring diagrams. note: separate cable entry openings must be used to maintain required spacing between power limited and non-power limited wiring. optional ea-cb may be required to separate power limited and non power limited wiring in the electrical box. 2. set the address on the module per job drawings using the ir configura - tion tool (model no. ea-ct). 3. secure module to electrical box (supplied by installer). auto addressing eclipse series devices are capable of supporting auto addressing, if the fire alarm control panel is designed to do so. in auto addressing, the control panel, through the use of each devices on-board isolators, can automatically assign device addresses. in order to control which devices are addressed first in wiring configurations with branches, a branch marker can be set at a particular device. a branch marker is an electronic value from 0 to 255 stored in the device memory. the branch markers are set with the ir configuration tool, ea-ct. terminal definitions t1 (+) slc in/out t7 normally closed #1 t2 (C) slc in/out t8 common #1 t3 (+) slc in/out t9 normally open #1 t4 (C) slc in/out t10 normally closed #2 t5 (+) dry contact input t11 common #2 t6 (C) dry contact input t12 normally open #2 w arning all relay switch contacts are shipped in the standby state (open) state, but may have transferred to the activated (closed) state during shipping. to ensure that the switch contacts are in their correct state, modules must be made to com - municate with the panel before connecting circuits controlled by the module. installation and maintenance instructions i56-2023-005 3825 ohio avenue, st. charles, illinois 60174 1.800.sensor2; fax: 630.377.6495 www.systemsensor.com
this device complies with part 15 of the fcc rules. operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. note: this equipment has been tested and found to comply with the limits for a class b digital device, pursuant to part 15 of the fcc rules. these limits are designed to provide reasonable protection against harmful interference in a residential installation. this equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. however, there is no guarantee that interference will not occur in a particular installa - tion. if this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: C reorient or relocate the receiving antenna. C increase the separation between the equipment and receiver. C connect the equipment into an outlet on a circuit different from that to which the receiver is connected. C consult the dealer or an experienced radio/tv technician for help. fcc s tatement d500-61-00 2 i56-2023-005 ?2007 system sensor figure 2: wiring diagram: from p anel or previous p anel (C) (+) (C) (+) (C) (+) (C) (+) 1 2 3 4 to next device 5 6 12 11 10 9 8 7 { rela y cont acts note: normall y open or normall y closed cont act device (not super vised). note: normall y closed option ma y not be used for fire applica tions. connect modules to listed compat ible control pa nels only normall y open (t12) common (t1 1) normall y closed (t10) normall y open (t9) common (t8) normally closed (t7) rela y cont act #2 rela y cont act #1 signal line circuit (slc) 30 vdc max. twisted p air recommended and is power limited and super vised module does not super- vise controlled circuits. terminals 1-6 are power limited. terminals 7-12 are non-power limited. c0110-02 system sensor warrants its enclosed module to be free from defects in materials and workmanship under normal use and service for a period of three years from date of manufacture. system sensor makes no other express warranty for this module. no agent, representative, dealer, or employee of the company has the authority to increase or alter the obligations or limitations of this warranty. the companys obligation of this warranty shall be limited to the repair or replacement of any part of the module which is found to be defective in materials or workmanship under normal use and service during the three year period commencing with the date of manufacture. after phoning system sensors toll free number 800-sensor2 (736-7672) for a return authorization number, send defective units postage prepaid to: system sensor, returns department, ra three-year limited w arranty #__________, 3825 ohio avenue, st. charles, il 60174. please include a note describing the malfunction and suspected cause of failure. the company shall not be obligated to repair or replace units which are found to be defective because of damage, unreasonable use, modifications, or alterations occurring after the date of manufacture. in no case shall the company be liable for any consequential or incidental damages for breach of this or any other warranty, expressed or implied whatsoever, even if the loss or damage is caused by the companys negligence or fault. some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. this warranty gives you specific legal rights, and you may also have other rights which vary from state to state.


▲Up To Search▲   

 
Price & Availability of EM-1RI

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X