If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
agilent t-1 3 / 4 (5 mm) precision optical performance alingap led lamps data sheet features well defined spatial radiation patterns viewing angles: 6 , 15 , 23 , 30 high luminous output colors: 590 nm amber 605 nm orange 615 nm reddish-orange 626 nm red high operating temperature: t j led = +130 c superior resistance to moisture package options: with or without lead stand-offs benefits viewing angles match traffic management sign requirements colors meet automotive and pedestrian signal specifications superior performance in outdoor environments suitable for autoinsertion onto pc boards applications traffic management: traffic signals pedestrian signals work zone warning lights variable message signs commercial outdoor advertising: signs marquees automotive: exterior and interior lights description these precision optical perform- ance alingap leds provide superior light output for excellent readability in sunlight and are extremely reliable. alingap led technology provides extremely stable light output over long periods of time. precision optical performance lamps utilize the aluminum indium gallium phosphide (alingap) technology. these led lamps are untinted, nondiffused, t-1 3 / 4 packages incorporating second generation optics producing well defined spatial radiation patterns at specific viewing cone angles. these lamps are made with an advanced optical grade epoxy, offering superior high tempera- ture and high moisture resistance performance in outdoor signal and sign applications. the high maximum led junction temperature limit of +130 c enables high temperature operation in bright sunlight conditions. the package epoxy contains both uv-a and uv-b inhibitors to reduce the effects of long term exposure to direct sunlight. these lamps are available in two package options to give the designer flexibility with device mounting. sunpower series hlmp-elxx hlmp-ehxx hlmp-ejxx hlmp-egxx
2 device selection guide typical color and dominant lamps without lamps with standoffs luminous intensity viewing angle wavelength standoffs on leads on leads iv (mcd) [1,2] @ 20 ma 2 1 / 2 (deg.) [4] (nm), typ. [3] (outline drawing a) (outline drawing b) min. max. hlmp-el08-vy000 hlmp-el10-vy000 4200 12000 hlmp-el08-vyk00* 4200 12000 hlmp-el08-vxk00* 4200 9300 hlmp-el08-vx400** 4200 9300 hlmp-el08-vx000 4200 9300 hlmp-el08-wz000 hlmp-el10-wz000 5500 16000 amber 590 hlmp-el08-xz400** 7200 16000 hlmp-el08-xz000 7200 16000 hlmp-el08-xzk00* 7200 16000 hlmp-el08-xy000 7200 12000 hlmp-el08-xyk00* 7200 12000 hlmp-el08-x1k00* 7200 21000 hlmp-el08-x1000 hlmp-el10-x1000 7200 21000 6 [5] hlmp-ej08-wz000 hlmp-ej10-wz000 5500 16000 orange 605 hlmp-ej08-x1000 hlmp-ej10-x1000 7200 21000 hlmp-ej08-y2000 hlmp-ej10-y2000 9300 27000 hlmp-eh08-ux000 hlmp-eh10-ux000 3200 9300 hlmp-eh08-vy000 hlmp-eh10-vy000 4200 12000 red-orange 615 hlmp-eh08-wz000 hlmp-eh10-wz000 5500 16000 hlmp-eh08-x1000 hlmp-eh10-x1000 7200 21000 hlmp-eh08-y2000 hlmp-eh10-y2000 9300 21000 hlmp-eg08-vw000 4200 7200 hlmp-eg08-vy000 hlmp-eg10-vy000 4200 12000 hlmp-eg08-wz000 hlmp-eg10-wz000 5500 16000 red 626 hlmp-eg08-x1000 hlmp-eg10-x1000 7200 21000 hlmp-eg08-yz000 9300 16000 hlmp-eg08-y1000 9300 21000 hlmp-eg08-y2000 hlmp-eg10-y2000 9300 27000 notes: 1. the luminous intensity is measured on the mechanical axis of the lamp package. 2. the optical axis is closely aligned with the package mechanical axis. 3. the dominant wavelength, d , is derived from the cie chromaticity diagram and represents the color of the lamp. 4. 1/2 is the off-axis angle where the luminous intensity is one half the on-axis intensity. 5. the intensity of narrow viewing angle lamps is measured at the intensity peak. part numbers in bold are recommended for new designs. *hlmp-xlxx-xxk00 are selected to amber color bins 2 and 4 only. **hlmp-xlxx-xx400 are selected to amber color bin 4 only. 3 typical color and dominant lamps without lamps with standoffs luminous intensity viewing angle wavelength standoffs on leads on leads iv (mcd) [1,2] @ 20 ma 2 1 / 2 (deg.) [4] (nm), typ. [3] (outline drawing a) (outline drawing b) min. max. hlmp-el15-ps000 hlmp-el17-ps000 880 2500 hlmp-el15-qr000 1150 1900 hlmp-el15-qrk00* 1150 1900 hlmp-el15-qs000 1150 2500 hlmp-el15-qs400** 1150 2500 hlmp-el15-qsk00* 1150 2500 hlmp-el15-qt000 hlmp-el17-qt000 1150 3200 hlmp-el15-qtk00* 1150 3200 hlmp-el15-ru000 hlmp-el17-ru000 1500 4200 hlmp-el17-sv000 1900 5500 amber 590 hlmp-el15-tw000 hlmp-el17-tw000 2500 7200 hlmp-el15-twk00* 2500 7200 hlmp-el15-tuk00* 2500 4200 15 hlmp-el15-tv400** 2500 5500 hlmp-el15-ux000 hlmp-el17-ux000 3200 9300 hlmp-el15-vy000 hlmp-el17-vy000 4200 12000 hlmp-el15-vyk00* 4200 12000 hlmp-el15-vx000 4200 9300 hlmp-el15-vxk00* 4200 9300 hlmp-el15-vx400** 4200 9300 hlmp-el15-vw000* 4200 7200 hlmp-el15-vwk00* 4200 7200 hlmp-ej15-ps000 880 2500 orange 605 hlmp-ej15-ru000 hlmp-ej17-ru000 1500 4200 hlmp-ej15-sv000 hlmp-ej17-sv000 1900 5500 hlmp-eh15-qt000 hlmp-eh17-qt000 1150 3200 red-orange 615 hlmp-eh15-ru000 hlmp-eh17-ru000 1500 4200 hlmp-eh15-tw000 hlmp-eh17-tw000 2500 7200 hlmp-eh15-ux000 hlmp-eh17-ux000 3200 9300 device selection guide (continued) notes: 1. the luminous intensity is measured on the mechanical axis of the lamp package. 2. the optical axis is closely aligned with the package mechanical axis. 3. the dominant wavelength, d , is derived from the cie chromaticity diagram and represents the color of the lamp. 4. 1/2 is the off-axis angle where the luminous intensity is one half the on-axis intensity. 5. the intensity of narrow viewing angle lamps is measured at the intensity peak. part numbers in bold are recommended for new designs. *hlmp-xlxx-xxk00 are selected to amber color bins 2 and 4 only. **hlmp-xlxx-xx400 are selected to amber color bin 4 only. 4 typical color and dominant lamps without lamps with standoffs luminous intensity viewing angle wavelength standoffs on leads on leads iv (mcd) [1,2] @ 20 ma 2 1 / 2 (deg.) [4] (nm), typ. [3] (outline drawing a) (outline drawing b) min. max. HLMP-EG15-PS000 880 2500 hlmp-eg15-qt000 hlmp-eg17-qt000 1150 3200 15 red 626 hlmp-eg15-ru000 hlmp-eg17-ru000 1500 4200 hlmp-eg15-ux000 hlmp-eg17-ux000 3200 9300 hlmp-eg15-tw000 hlmp-eg17-tw000 2500 7200 hlmp-el24-mq000 520 1500 hlmp-el24-nr000 hlmp-el26-nr000 680 1900 hlmp-el24-ps000 hlmp-el26-ps000 880 2500 hlmp-el24-psk00* 880 2500 hlmp-el24-pr400** 880 1900 hlmp-el24-pqk00* 880 1500 hlmp-el24-qr000 1150 1900 hlmp-el24-qrk00* 1150 1900 hlmp-el24-qs000 1150 2500 hlmp-el24-qsk00* 1150 2500 hlmp-el24-qs400** 1150 2500 23 amber 590 hlmp-el24-qt000 hlmp-el26-qt000 1150 3200 hlmp-el24-qtk00* 1150 3200 hlmp-el24-ru000 hlmp-el26-ru000 1500 4200 hlmp-el24-ruk00* 1500 4200 hlmp-el26-sv000 1900 5500 hlmp-el24-stk00* 1900 3200 hlmp-el24-suk00* 1900 4200 hlmp-el24-su400** 1900 4200 hlmp-el24-sv000 1900 5500 hlmp-el24-svk00* 1900 5500 hlmp-el24-tw000 hlmp-el26-tw000 2500 7200 hlmp-el24-twk00* 2500 7200 device selection guide (continued) notes: 1. the luminous intensity is measured on the mechanical axis of the lamp package. 2. the optical axis is closely aligned with the package mechanical axis. 3. the dominant wavelength, d , is derived from the cie chromaticity diagram and represents the color of the lamp. 4. 1/2 is the off-axis angle where the luminous intensity is one half the on-axis intensity. 5. the intensity of narrow viewing angle lamps is measured at the intensity peak. part numbers in bold are recommended for new designs. *hlmp-xlxx-xxk00 are selected to amber color bins 2 and 4 only. **hlmp-xlxx-xx400 are selected to amber color bin 4 only. 5 typical color and dominant lamps without lamps with standoffs luminous intensity viewing angle wavelength standoffs on leads on leads iv (mcd) [1,2] @ 20 ma 2 1 / 2 (deg.) [4] (nm), typ. [3] (outline drawing a) (outline drawing b) min. max. orange 605 hlmp-ej24-qt000 hlmp-ej26-qt000 1150 3200 hlmp-ej24-ru000 hlmp-ej26-ru000 1500 4200 hlmp-eh26-ps000 880 2500 red-orange 615 hlmp-eh24-qt000 hlmp-eh26-qt000 1150 3200 23 hlmp-eh24-ru000 hlmp-eh26-ru000 1500 4200 hlmp-eh24-sv000 hlmp-eh26-sv000 1900 5500 hlmp-eg24-ps000 hlmp-eg26-ps000 880 2500 red 626 hlmp-eg24-qt000 hlmp-eg26-qt000 1150 3200 hlmp-eg24-ru000 hlmp-eg26-ru000 1500 4200 hlmp-el30-mq000 hlmp-el32-mq000 520 1500 hlmp-el30-nr000 hlmp-el32-nr000 680 1900 hlmp-el30-pq000 880 1500 hlmp-el30-pqk00* 880 1500 hlmp-el30-pr000 880 1900 hlmp-el30-pr400** 880 1900 hlmp-el30-prk00* 880 1900 hlmp-el30-ps000 hlmp-el32-ps000 880 2500 30 amber 590 hlmp-el30-psk00* 880 2500 hlmp-el30-qrk00* 1150 1900 hlmp-el30-qs000 1150 2500 hlmp-el30-qs400** 1150 2500 hlmp-el30-qt000 hlmp-el32-qt000 1150 3200 hlmp-el30-qtk00* 1150 3200 hlmp-el30-st000 1900 3200 hlmp-el30-su000 1900 4200 hlmp-el30-su400** 1900 4200 hlmp-el30-suk00* 1900 4200 device selection guide (continued) notes: 1. the luminous intensity is measured on the mechanical axis of the lamp package. 2. the optical axis is closely aligned with the package mechanical axis. 3. the dominant wavelength, d , is derived from the cie chromaticity diagram and represents the color of the lamp. 4. 1/2 is the off-axis angle where the luminous intensity is one half the on-axis intensity. 5. the intensity of narrow viewing angle lamps is measured at the intensity peak. part numbers in bold are recommended for new designs. *hlmp-xlxx-xxk00 are selected to amber color bins 2 and 4 only. **hlmp-xlxx-xx400 are selected to amber color bin 4 only. 6 typical color and dominant lamps without lamps with standoffs luminous intensity viewing angle wavelength standoffs on leads on leads iv (mcd) [1,2] @ 20 ma 2 1 / 2 (deg.) [4] (nm), typ. [3] (outline drawing a) (outline drawing b) min. max. hlmp-el30-stk00* 1900 3200 amber hlmp-el30-sv000 1900 5500 hlmp-el30-svk00* 1900 5500 hlmp-el32-sv000 1900 5500 hlmp-ej30-mq000 520 1500 orange 605 hlmp-ej30-nr000 hlmp-ej32-nr000 680 1900 hlmp-ej30-ps000 hlmp-ej32-ps000 880 2500 hlmp-eh30-mq000 hlmp-eh32-mq000 520 1500 30 hlmp-eh30-nr000 hlmp-eh32-nr000 680 1900 red-orange 615 hlmp-eh30-ps000 hlmp-eh32-ps000 880 2500 hlmp-eh30-qt000 hlmp-eh32-qt000 1150 3200 hlmp-eh30-ru000 hlmp-eh32-ru000 1500 4200 hlmp-eg30-kn000 310 880 hlmp-eg30-mq000 hlmp-eg32-mq000 520 1500 hlmp-eg30-nq000 680 1500 hlmp-eg30-nr000 hlmp-eg32-nr000 680 1900 red 626 hlmp-eg30-pq000 880 1500 hlmp-eg30-pr000 880 1900 hlmp-eg30-ps000 hlmp-eg32-ps000 880 2500 hlmp-eg30-qt000 hlmp-eg32-qt000 1150 3200 device selection guide (continued) notes: 1. the luminous intensity is measured on the mechanical axis of the lamp package. 2. the optical axis is closely aligned with the package mechanical axis. 3. the dominant wavelength, d , is derived from the cie chromaticity diagram and represents the color of the lamp. 4. 1/2 is the off-axis angle where the luminous intensity is one half the on-axis intensity. 5. the intensity of narrow viewing angle lamps is measured at the intensity peak. part numbers in bold are recommended for new designs. *hlmp-xlxx-xxk00 are selected to amber color bins 2 and 4 only. **hlmp-xlxx-xx400 are selected to amber color bin 4 only. 7 hlmp - x x xx - xxxxx mechanical options 00: bulk packaging dd: ammo pack yy: flexi-bin; bulk packaging zz: flexi-bin; ammo pack color bin selections 0: no color bin limitation 4: amber color bin 4 only k: amber color bins 2 and 4 only maximum intensity bin 0: no iv bin limitation minimum intensity bin viewing angle & lead stand offs 08: 6 deg without lead stand offs 10: 6 deg with lead stand offs 15: 15 deg without lead stand offs 17: 15 deg with lead stand offs 24: 23 deg without lead stand offs 26: 23 deg with lead stand offs 30: 30 deg without lead stand offs 32: 30 deg with lead stand offs color g: 626 nm red h: 615 nm red-orange j: 605 nm orange l: 590 nm amber package e: 5 mm round part numbering system 8 notes: 1. all dimensions are in millimeters (inches). 2. leads are mild steel, solder dipped. 3. tapers shown at top of leads (bottom of lamp package) indicate an epoxy meniscus that may extend about 1 mm (0.040 in.) down the leads. 4. recommended pc board hole diameters: lamp package a without stand-offs: flush mounting at base of lamp package = 1.143/1.067 (0.044/0.042). lamp package b with stand-offs: mounting at lead stand-offs = 0.965/0.889 (0.038/0.035). 5. for dome heights above lead stand-off seating plane, d, lamp package b, see table. b package dimensions a 1.14 0.20 (0.045 0.008) 5.80 0.20 (0.228 0.008) 5.00 0.20 (0.197 0.008) 31.60 (1.244) min. 0.70 (0.028) max. 1.00 (0.039) min. 8.71 0.20 (0.343 0.008) 2.54 0.38 (0.100 0.015) 0.50 0.10 (0.020 0.004) sq. typ. cathode lead 2.35 (0.093) max. cathode flat 1.14 0.20 (0.045 0.008) 5.80 0.20 (0.228 0.008) 5.00 0.20 (0.197 0.008) 31.60 (1.244) min. 0.70 (0.028) max. 1.00 (0.039) min. 8.71 0.20 (0.343 0.008) 2.54 0.38 (0.100 0.015) 0.50 0.10 (0.020 0.004) sq. typ. cathode lead cathode flat d 1.50 0.15 (0.059 0.006) part no. d hlmp-xx10 12.37 0.25 (0.487 0.010) hlmp-xx17 12.42 0.25 (0.489 0.010) hlmp-xx26 12.52 0.25 (0.493 0.010) hlmp-xx32 11.96 0.25 (0.471 0.010) 9 electrical/optical characteristics at t a = 25 c parameter symbol min. typ. max. units test conditions forward voltage i f = 20 ma amber ( l d = 590 nm) 2.02 orange ( l d = 605 nm) v f 1.98 2.4 v red-orange ( l d = 615 nm) 1.94 red ( l d = 626 nm) 1.90 reverse voltage v r 520 vi f = 100 a peak wavelength: peak of wavelength of amber ( l d = 590 nm) 592 spectral distribution orange ( l d = 605 nm) l peak 609 nm at i f = 20 ma red-orange ( l d = 615 nm) 621 red ( l d = 626 nm) 635 spectral halfwidth ? l 1/2 17 nm wavelength width at spectral distribution 1 / 2 power point at i f = 20 ma speed of response t s 20 ns exponential time constant, e -t/ts capacitance c 40 pf v f = 0, f = 1 mhz thermal resistance r q j-pin 240 c/w led junction-to-cathode lead luminous efficacy [1] emitted luminous amber ( l d = 590 nm) 480 power/emitted radiant orange ( l d = 605 nm) h v 370 lm/w power red-orange ( l d = 615 nm) 260 red ( l d = 626 nm) 150 note: 1. the radiant intensity, i e , in watts per steradian, may be found from the equation i e = i v / h v , where i v is the luminous intensity in candelas and h v is the luminous efficacy in lumens/watt. absolute maximum ratings at t a = 25 c /3 +/ a&%8%'b !!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!;. *3 +/ a8%'b !!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!! &.. 3 +/ a'b !!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!'. =c # = d&.. ???? ???? ? ???? ? ????? ???? ?????? ???? ????? ??????????? ??????????????????? ?????????????????????? ????????????? ???????????????????? ???????? 10 figure 2. forward current vs. forward voltage. figure 3. relative luminous intensity vs. forward current. figure 4. maximum forward current vs. ambient temperature. derating based on t jmax = 130 c. figure 1. relative intensity vs. peak wavelength. figure 5. representative spatial radiation pattern for 6 viewing angle lamps. wavelength nm relative intensity 550 600 650 700 1.0 0.5 0 amber red-orange orange red current ma 1.0 0 v f forward voltage v 2.5 100 40 30 1.5 2.0 60 3.0 10 20 50 red amber 70 80 90 relative luminous intensity (normalized at 20 ma) 0 0 i f dc forward current ma 40 3.0 2.0 1.5 1.0 0.5 20 60 2.5 i f forward current ma 0 0 t a ambient temperature c 40 80 50 40 30 20 10 20 60 100 r ja = 585 c/w r ja = 780 c/w relative intensity % 100 0 angular displacement degrees 80 60 50 70 20 -20 -15 10 30 40 -10 0 5 10 15 20 25 90 -25 -5 11 bin name min. max. k 310 400 l 400 520 m 520 680 n 680 880 p 880 1150 q 1150 1500 r 1500 1900 s 1900 2500 t 2500 3200 u 3200 4200 v 4200 5500 w 5500 7200 x 7200 9300 y 9300 12000 z 12000 16000 1 16000 21000 2 21000 27000 intensity bin limits (mcd at 20 ma) bin name min. max. 1 584.5 587.0 2 587.0 589.5 4 589.5 592.0 6 592.0 594.5 amber color bin limits (nm at 20 ma) tolerance for each bin limit is 0.5 nm. note: d hn-co mwaehmp-oem-mp oaphplmy-tae cpopphthco han-at-leayvc pd-xeayvc p oo&-na -am-oiohpoapm-hn-opp-ahn co mwaehmpd figure 7. representative spatial radiation pattern for 23 viewing angle lamps. figure 8. representative spatial radiation pattern for 30 viewing angle lamps. figure 6. representative spatial radiation pattern for 15 viewing angle lamps. relative intensity e % 100 0 e angular displacement e degrees 80 60 50 70 20 10 30 40 90 -20 -15 -10 0 5 10 15 20 25 -25 -5 relative intensity e % 100 0 e angular displacement e degrees 80 60 50 70 20 10 30 40 90 -20 -15 -10 0 5 10 15 20 25 -25 -5 relative intensity e % 1.00 0 e angular displacement e degrees 0.80 0.60 0.50 0.70 0.20 0.10 0.30 0.40 0.90 -20 -15 -10 0 5 10 15 20 25 -25 -5 tolerance for each bin limit is 15%. www.agilent.com/semiconductors for product information and a complete list of distributors, please go to our web site. for technical assistance call: americas/canada: +1 (800) 235-0312 or (916) 788-6763 europe: +49 (0) 6441 92460 china: 10800 650 0017 hong kong: (+65) 6756 2394 india, australia, new zealand: (+65) 6755 1939 japan: (+81 3) 3335-8152(domestic/interna- tional), or 0120-61-1280(domestic only) korea: (+65) 6755 1989 singapore, malaysia, vietnam, thailand, philippines, indonesia: (+65) 6755 2044 taiwan: (+65) 6755 1843 data subject to change. copyright ?2005 agilent technologies, inc. obsoletes 5989-0659en april 27, 2005 5989-2916en |
Price & Availability of HLMP-EG15-PS000 |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |