(1/2) 003-01 / 20080818 / e9164_zug_13as.fm ? all specifications are subject to change without notice. emc filters for ac power line inlet-socket type zug-13as series features this inlet-socket type emc filter prevent microcomputer opera- tional errors by use of a common mode choke coil featuring an amorphous core with exceptional magnetic characteristics. sharply attenuates high voltage pulses entering from the power supply line. for example, the ZUG2203-13AS achieves over 20db of attenuation for a 600v, 400ns input pulse. lug type output terminals for soldering. compact and low-cost due to use of an insulating plastic case. it is a product conforming to rohs directive. applications personal computers, computer terminals, various types of office automation equipment, digital devices(ecrs, electronic calcula- tors, electronic scales, etc.), measurement equipment, medical equipment, etc. particularly appropriate for various types of elec- tronic devices that require miniaturization. safety standards shapes and dimensions typical dimensions for installation tighten the panel mounting m3 dia. bolt with the torque under 5.88x10 -1 n m. dimensions in mm case:plastic, input terminal:inlet-socket(en60320), output terminal: lug terminal electrical characteristics ? input pulse width:0.4 s conformity to rohs directive part no. standard and standard no. u.s.a. canada europe ul1283 csa c22.2 no.8 en60939 ZUG2203-13AS e62388 lr76849c p08208996 zug2206-13as e62388 lr76849c p08208996 ul csa nemko b e f ground terminal i g d a ?h cj from back side panel from front panel 31.2 40 23.2 ?3.6 r5.5 30 40 20 11 ?3.6 or m3 tap r1 part no. abcdef g?hi j ZUG2203-13AS, 2206-13as 50 40.2 22.5 40 35 5.2 30.5 3.3 20 8 part no. ZUG2203-13AS zug2206-13as rated voltage eac (v) 250 250 rated current (a) 3 6 test voltage eac (v)[between terminal and ground terminal] 1500 1500 i nsulation resistance (m ? )[dc.500v,1min/between terminal and ground terminal] 100min. 100min. leakage current (ma) [250v 60hz] 0.5max. 0.5max. dc resistance(m ? ) 150max. 100max. operating temperature range( c)[including self-temperature rise] ?25 to +85 ?25 to +85 with derating over(c) 55 55 temperature rise( c) 30max. 30max. attenuation frequency range (mhz)[+5 to +35 c] differential mode 30db 4 to 30 5 to 30 common mode 30db 3 to 30 5 to 30 pulse attenuation characteristics input pulse voltage (kv) ? differential mode 0.6[10db] 0.3[10db] common mode 0.6[20db] 0.4[10db] weight (g) 33 33 conformity to rohs directive: this means that, in conformity with eu directive 2002/95/ec, lead, cadmium, mercury, hexavalent chromium, and specific bromine-based flame retardants, pbb and pbde, have not been used, except for exempted applications.
(2/2) 003-01 / 20080818 / e9164_zug_13as.fm all specifications are subject to change without notice. typical electrical characteristics attenuation vs. frequency characteristics pulse attenuation characteristics ZUG2203-13AS ZUG2203-13AS zug2206-13as zug2206-13as circuit diagram 100 80 60 40 20 0 0.1 0.3 1 3 10 30 100 300 frequency ( mhz ) attenuation ( db ) differential mode common mode 0 500 1000 1500 2000 300 250 200 150 100 0 50 0 500 1000 1500 2000 300 250 200 150 100 0 50 in p ut volta g e ( v ) output voltage ( v ) pulse width: 0.1 s pulse width: 0.4 s differential mode common mode 100 80 60 40 20 0 0.1 0.3 1 3 10 30 100 300 frequency ( mhz ) attenuation ( db ) differential mode common mode 0 500 1000 1500 2000 300 250 200 150 100 0 50 input voltage ( v ) output voltage ( v ) pulse width: 0.1 s pulse width: 0.4 s differential mode common mode 1 2 4 3
|