  Datasheet File OCR Text:
  operational speci cations small sensor (flw12) flow transmitter (flv) series ultrasonic flowmeter < s (standard type)> features 1. compact and light-weight the adoption of the latest electronics and digital signal processing technologies has reduced the size and weight of the converter to almost half, in comparison with tradi- tional model. 2. full variety of sensors including explosion-proof type the owmeter can be used with various types of sensors applicable for wide range of pipe size (?3 to ?000mm) and uid temperature (-40 to +200?). explosion-proof type per cenelec std. can be also avail- able. 3. high accuracy the owmeter is designed for high accurary (better than ?.0% of rate) by dynamic correction of fully-developed ow pro le. reynolds number is calculated and a meter factor (k) is automatically applied for best accuracy at all ow velocities. further, the adoption of new sound veloc- ity measurement system permits measurements of uids of unknown sound velocity. moreover, affection from uid temperature and pressure is negligible (auto-temp./ press. compensation). 4. excellent resistance against aerated ow fuji's unique abm feature improves measurement reli- ability for different ow like slurries, sludge, raw sewage and bubble-contained ow (acceptable up to air bubble of 12% volume at 1m/s velocity). 5. quick response with the use of high-speed micro-processor suited for digital signal processing, the f ast response time is real- ized. 6. multi-lingual the following languages are supported for display: japanese (katakana), english, german and french 7. excellent performance and easy operation large lcd and function keys are allowing easy con gura- tion and trouble shooting. ?lcd with back light ?easy mounting of sensor ?trouble shooting specifications flv 3, flw 2, fld? system con guration: the system is composed of a sensor (model flw? or fld?) and a converter (model flv?) as for explosion-proof type, the converter should be located in safe area. application: liquid ow through which ultrasonic signal can be transmitted (water, sea water, oil and uid of unknown sound velocity) turbidity; 1 0000deg(mg/l) or less fluid temperature; -40 to +80? for small (flw12), middle (flw41) and large sen- sor (flw5) -40 to +60? for explosion- proof sensors (flw1, 4 & 5) -40 to +100? for small dia- meter sensor (fld22) -40 to +200? for high tem- perature sensor (fld32) type of ow; well-developed turbulent or laminar ow in a full- lled pipe this flowmeter is a clamp-on type ultrasonic flowmeter based on transit-time measuring method. thanks to mi cro- pro- cessor based electronics, the owmeter can be easily con- gured from the front keyboard to speci c applications. the owmeter is suitable for liquid ow measurements for pipe size 13mm to 6000mm diameter. the flowmeter is a compact and light-weight instrument inco- porating the latest electronics and high speed digital signal processing technologies (32bit mpu), realizing high perfor- mance and easy operation. EDSX6-71L dec. 20, 2007 data sheet date
2 flv 3, flw 2, fld? total value display function: display of forward or reverse total, are selectable, max: 9 digits unit; metric/inch system, selectable analog output signal: one 4 to 20ma dc current output max. load resistance 1k digital status output: 2 transistor outputs available open collector output; 30v dc, 0.1a configurable to provide following infor- mation selected. ?total pulse ?flow switch ?over ow ?range change-over ?flow direction ?range over ?memory alarm ?receiving signal abnormal metric system inch system m/s velocity ft/s l/s, l/min, l/h, ml/d, m 3 /s m 3 /min, m 3 /h, mm 3 /d, bbl/s, bbl/min, bbl/h, mbbl/d flow rate note : the " g al" means us g al. gal/s, gal/min, gal/h, mgal/d, ft 3 /s, ft 3 /min, ft 3 /h, mft 3 /d, bbl/s, bbl/min, bbl/h, mbbl/d metric system inch system total ml, l, m 3 , km 3 , mm 3 , mbbl, bbl, kbbl gal, kgal, ft 3 , kft 3 , mft 3 , mbbl, bbl, kbbl con guration: the owmeter is fully con gurable from front keyboard by menu-driven software zero adjustment: two methods are available set zero/manual zero adjustment for zero ow damping for analog output and indication: 0 to 100s, con gurable low ow cut-off: 0 to 5m/s, con gurable function/performance speci cations measuring accuracy: pipe size/13mm to under 50mm ?.03m/s for ow rate: under 2m/s ?.75% to ?.5% of rate for ow rate: 2m/s to 32m/s pipe size/50mm to under 300mm ?.02m/s for ow rate: under 2m/s ?.5% to ?.0% of rate for ow rate: 2m/s to 32m/s pipe size/300mm up to 6000mm ?.01m/s for ow rate: under 1m/s ?.5% to ?.0% of rate for ow rate: 1m/s to 32m/s (note) ref erence conditions are based on jemis-032. response time: 0.5s or less communication interface: rs232-c equivalent baud rate: 2400 to 9600bps distance: 15m max. following information can be sent. ?velocity ?flow rate ?total ?alarm output status indicator display: lcd with back light, 16 letters 2 lines display language: japanese (katakana), english, german or french, selectable flow rate display function: display of velocity and ow rate (with ow direction) are selectable, max: 8 digits unit; metric/inch system selectable measurable ow pipe: size; 13mm to 100mm dia. with small diameter sensor (fld22) 50mm to 400mm dia. with small sensor (flw12) and high temp. sensor (fld32) 200mm to 1200mm dia. with mid- dle sensor (flw41) 200mm to 6000mm dia. with large sensor (flw5) material; c arbon steel, ss, cast iron, pvc, frp, asbestos, copper, aluminum, etc. lining; tar epoxy, mortar, rubber, or others straight pipe length (min); 10 x d upstream and 5 x d down stream required (d: pipe diameter) refer to jemis-032 for details. jemis: j apan electric measuring instruments manufac- tures associ-ations stan- dard. velocity: 0 to ?2m/s (bidirectional ow) power supply: two models are availble 100 to 240v ac ?0% 50/60hz, or 20 to 30v dc power consumption: approx. 20va maximum cable length for sensor: 150m ambient temperature: converter; -10 to +60? sensor; -20 to +60? ambient humidity: 90%rh or less. hazardous condition: nemko 00atex0054x ex. ? 2g, eexm ? t6, t amb =60? per cenelec std. en50014 & en50028 for explosion-proof sensors flw1, 4 & 5 combined with the converter flv speci c to them. grounding: class d (less than 100 ohm) in case of need as for explosion-proof type, ground- ings of sensors and converter should be done.
3 physical speci cations sensor cable: radio frequency co-axial cable rg-58a/u dimensions and mass of sensors: enclosure protection: small, middle and large sensor/ip67 small diameter and high temp. sensor/ ip52 flow transmitter/ip65 mounting: sensor/clamped on pipe wall flow transmitter/wall or pipe mount acoustic coupler: silicone grease for high temperature sensor, silicon rubber for others material: sensor case guide rail kind small sensor plastic 304ss+plastic small diameter plastic aluminum+plastic high-temperature 304ss aluminum+304ss middle sensor plastic large sensor plastic dimensions(h w d) mass kind small sensor 500 80 40mm approx. 1.0kg small diameter 320 53 90mm approx. 0.6kg high-temperature 530 52 205mm approx. 1.6kg approx. 1.4kg middle sensor 72 40 60mm approx. 0.4kg large sensor 104 93 62mm dimensions of ow transmitter : h277 ?w244 ?d95mm mass of ow transmitter : approx, 4.5kg sensor: enclosure of converter : aluminum alloy the flv converter is standard-equipped with the follow ing out- put functions which can be programmed through key opera- tion. total pulse output: the measured flow rate is integrated, and upon reaching a predetermined unit rate a single pulse is output. in the case of a forward/reverse owmeter, the ow rate in each direction is independently integrated and transmitted. low ow rate cutoff: arbitrarily settable between 0 and 5m/s the integration pulse cycle is settable in a range of 5 pulses/second to 1 pulse /day. auto multirange output: when the flow rate largely varies bet- ween low and high flow rates, output can be done with large output width for the whole ow range by adding the auto multirange function. either two ranges are selectable, and the minimum range is settable within the measurable range. the measuring range signal is transmitted from the do terminal. forward/reverse ow rate output: description of output function output [ma] 12 up to 20% 20 q 3 q 2 basic range when the flow direction of the fluid changes, then the ow rate can be mea- sured in either direction by adding this function. when the flow of fluid reverses, mea- surement is done at an arbitrary range set differently from for the forward direction. the ow direction is discrimi- nated by means of the lcd display and do terminal signal. ultrasonic pulses are propagated in turn between upstream and downstream sides, and the time difference produced according to the ow is detected whereby the ow rate is measured. q r q f 0 output [ma] low flow rate cutoff setting 4 - q+q 20
4 flv 3, flw 2, fld? (1) single-path system (v method) (2) single-path system (z method) measuring principle configuration the transit-time technique uses a pair of sensors with each sensor sending and receiving ultrasonic signals through the uid. when the fluid is flowing, signal transit-time in the down stream direction is shorter than one in the upstrream direc- tion. as the difference between these transit-time is proportional to the velocity, the ow rate and direction can be measured properly by detecting such time difference. flow transmitter flv: ?flow transmitter ?manual sensor flw, fld: ?sensor unit ?signal cable ?mounting chain/ belt/ wire ?silicone rubber/ grease (100gr) signal cable fly: orignal cable (2 wires) scope of delivery the product conforms to the requirements of the electromagnetic compatibility directive 89/336/eec as detailed within the technical construction file number tn510423. the applicable standards used to demonstrate compliance are : en 55011 : 1991 conducted and radiated emissions en 50082-1 : 1992 radiated immunity, esd and fbt classa detecter selection guide optional accessuries name drawing no. 1 guide rail for high-temperature sensor tk4c6164c1 output signal contact signal flow transmitter flow velocity v downstream-side sensor sensor upstream-side sensor d t 1 t 2 cable flow transmitter dc 4 to 20ma contact signal up to 2 points detector cable flow transmitter dc 4 to 20ma detector contact signal up to 2 points 200 100 80 0 ?40 50 13 100 200 400 1200 6000 pipe size (mm) large sensor (flw5) high-temperature sensor (fld3) small diameter sensor (fld2) fluid temperature (c) small sensor (flw1) middle sensor (flw4)
5 code symbols 3y y s v l f- 10 2 1 345678 11 91213 description y y t e f 1 4 1 power supply (5th digit code) 100 to 240v ac 10%, 50/60hz 20 to 30v dc s enclosure (4th digit code) outdoor immersion-proof case transistor output (6th digit code) 2 points conduit connections (10th digit code) g1/2(female screw) with water-proof connection option (11th digit code) none tag name plate use for explosion-proof sensors use for explosion-proof sensors with tag name plate analog output (7th digit code) 1 system 2 0 synchronism (9th digit code) none standard type 2 fl w yy description 12345678 910 0 11 y a 120 410 510 500 y 2 12 type small sensor (?0 to ?00) middle sensor (?00 to ?200) large sensor (?00 to ?000) large sensor (?00 to ?000) mounting method standard z method option none tag name plate (note) signal cables are not provided with detector. signal cable fly should be ordered separately. v method (standard) v method or z method moulded type y fl w description 12345678 91011 special cable 10 m 20 30 40 50 60 70 80 90 100 110 120 130 140 150 other y a 12 41 51 50 y 2 b c d e f g h j k l m n p q r z mounting method standard z method option none tag name plate 1 2 use submergence-proof type explosion-proof type per en50028 type small sensor (?0 to ?00) middle sensor (?00 to ?200) large sensor (?00 to ?000) large sensor (?00 to ?000) v method (standard) v method or z method 0 12 (note) 1. high turbid uid or scales sticking on the internal wall of pipes may interrupt the ultrasonic propagations. previous check with a portable type ultrasonic owmeter is recommended. 2. in case of cast iron pipes or pipes with lining, the large sensor is recom- mended rather than the middle sensor. 3. if the pipe has poor inside surface conditions or highly attenuating uids, you may not be able to a reliable signal, therefore you should use the flw50 sensor. small diameter and high-temperature sensor 1 sy d l f- 2 1 345678 9 description y belt and coupler fixed type 2 3 2 2 0 0 s type small diameter sensor ( 13 to 100) high-temparature sensor (note) ( 50 to 400) special cable none (note) use the optional guide rail if a pipe that does not allow ultrasonic waves to pass through easily such as an old pipe, cast iron pipe, or a pipe with mortar lining is used, or when the ow of liquid high in turbidity is mea- sured. employ the z method for mounting. applicable diameter range: v method: ?0 to ?50 z method: ?50 to ?00 1 12345678 cable length (5, 6 and 7th digit) 5m 10 m 15 m 20 m 25 m 30 m 35 m 40 m 45 m 50 m 55 m 60 m 65 m 70 m 75 m 80 m 85 m 90 m 95 m 100 m 110 m 120 m 130 m 140 m 150 m 005 010 015 020 025 030 035 040 045 050 055 060 065 070 075 080 085 090 095 100 110 120 130 140 150 1 2 note: no need to order signal cable of fly when your ordering submergence-proof or explosion-proof type sensor. a pair of cables is provided as one unit. y l f description type of sensor (4th digit code) small, middle and large sensor (flw120/410/510) small dia. and high temp. sensor (fld 22/32)
6 flv ? 3, flw ? 2, fld?1 outline diagram (unit:mm) detector : flw120 (small sensor) flow transmitter : flv 60 80 40 sensor name plate chain & spring mounting device: ss chain & ss spring frame end ground terminal pipe (50a 300a) 500 mounting size (0 270) 72 39 40 40 40 40 3.2 95 14 230 220 312 2- 9 20 72 scale(inch) cursor 52.5 scale(mm) distance between two sensors 0~133 90 max 36 320 saddle bnc connector lock nut element holder detector : fld220 (small diameter sensor) mounting device: ss belt connection diagram to downstream-side sensor to upstream-side sensor ac power supply hf sh contact signal analog signal sh hf g g ln + 12345678910 123 dc power supply 123 + + + to converter g+
7 19 detector : flw 2 (small/middle explosion-proof sensor) wire rope wire rope detector ground terminal ground terminal detector mtg.spring mtg.spring 104 93 62 114 1 2 4 1 detector : flw5 2 (large explosion-proof sensor) 1 0 b type flw122 flw412 a 68 114 b 10 19 72 40 a 60 19 detector : fld320 (high-temperature sensor) detector : flw5 0 (large sensor) detector : flw410 (middle sensor) wire rope wire rope detector ground terminal detector mtg.spring mtg.spring 104 93 62 114 52 26 33 90max 33 205max 33 530 cursor element holder distance between two elements scale (inch) lock nut bnc connector scale (mm) saddle 0 330 0 1 mounting device: ss belt 19 72 40 114 60
installation instruction for exprosion-proof type sensors pipe fullfilled with liquid pipe fullfilled with liquid operating voltage:max. 200v to gnd flow transmitter model flv coax cable ( rg58a/u or equivallent ) ci 20nf li 50 h sensors model flw entity parameters ci 8nf li = 0 hf hazardous area safe area note : all groundings are in accordance with class d (less than 100 ohm) system certification: eex m ll t6 ambient temperature: -20 to +60? for all unit s liquid temperature: -40 to +60? gnd hf gnd hf sh gnd hf 250vac/250vdc sh gnd l n flow transmitter model flv coax cable ( rg58a/u or equivallent ) ci 20nf(total) li 50 h(total) sensors model flw entity parameters ci 8nf li = 0 hf hazardous area safe area note : any certified junction box conforming to the types of protection listed in en50014 can be used to relay the co-axial signal cables. gnd hf gnd hf sh gnd hf 250vac/250vdc sh gnd l n cenelec certified junction box information in this catalo g is sub j ect to chan g e without notice. printed in japa n sales div. iii, international sales group global business group gate city ohsaki, east tower, 11-2, osaki 1-chome, shinagawa-ku, tokyo 141-0032, japan http://www.fesys.co.jp/eng phone: 81-3-5435-7280, 7281 fax: 81-3-5435-7425 http://www.fic-net.jp/eng caution on safety *before using this product, be sure to read its instruction manual in advance. flv ? 3, flw ? 2, fld?1


▲Up To Search▲   

 
Price & Availability of EDSX6-71L

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X