Part Number Hot Search : 
HE7054 FX826DW BE681T BSD223P CC721 DS9097U BTS611L 20UG5051
Product Description
Full Text Search
 

To Download EDSX6-140D Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  this flowmeter is a clamp-on type ultrasonic flow meter based on transit-time measuring method. making full use of the latest electronics and digital signal processing technologies, we realized a compact and light- weight design, and improved the accuracy and easiness to use while keeping with anti-bubble performance. the communication function (modbus: option) is also applicable. features 1. compact a nd l ight-weight thanks to the adoption of the latest electronics the flow transmitter size and mass are 1/3 of our traditional instrument. 2. full v ariety o f s ensors the flowmeter can be used with various types of sensors applicable for wide range of pipe size (?13 to ?6000mm) and fluid temperature (-40 to +200c). 3. high a ccuracy the flowmeter is designed for high accurary (better than 1.0% of rate) by dynamic correction of fully-developed flow profile. reynolds number is calculated and a meter factor (k) is automatically applied for best accuracy at all flow velocities. further, the adoption of new sound velocity measurement system permits measurements of fluids of unknown sound velocity. moreover, affection from fluid temperature and pressure is negligible (auto- temp./press. compensation). 4. excellent r esistance a gainst a erated f low fuji's unique abm feature improves measurement reli- ability for different flow like slurries, sludge, raw sewage and bubble-contained flow (acceptable up to air bubble of 12% volume at 1m/s velocity). 5. quick r esponse with the use of high-speed micro-processor suited for digital signal processing, the fast response time is realized. 6. multi-lingual the following languages are supported for display: japanese (katakana), english, german french, and spanish. 7. excellent p erformance a nd e asy o peration lcd and function keys are allowing easy configuration and trouble shooting. ? lcd with back light ? easy mounting of sensor ? trouble shooting ? easy operation with keypad on the front surface of the flow transmitter (fsvs) specifications operational s pecifications system c onfiguration: s ingle-path system of a flow transmit- ter (model fsv) and a detector (model fls/fsg/fsd) applicable f luid: homogenous liquid where the ultra- sonic signal can be transmitted b ubble quantity: 0 to 12vol% (for pipe size 50a, water, velocity 1m/s) f luid turbidity: 10000mg/l max. t ype of flow: fully-developed turbulent or laminar flow in a full-filled pipe flow v elocity r ange: 0 to 0.3 ... 32m/s data sheet fsv, fls/fsg/fsd EDSX6-140D apr. 1 , 2 011 date series ultrasonic flowmeter < > detector (fsd32) flow transmitter (fsvs) detector (flse12) (flse22) detector (fsg) detector (fsd22)
power s upply: 100 to 240v ac +10%/-15%, 50/60hz; or 20 to 30v dc signal c able ( between d etector a nd c onverter): c oaxial cable (5m standard, 300m (60m for popular detector (fls)) max.) h eat resistance: 80c installation e nvironment: n on-explosive area without direct sun- light, corrosive gas and heat radiation. ambient t emperature: f low transmitter: -20 to +55c d etector: -20 to +60c -20 to +80c (for flse ? 2 ? 2-a only) ambient h umidity: 9 5%rh max. grounding: class d (100 ?) arrester: p rovided as standard at output and power supply applicable p iping a nd f luid t emperature: detector flse12 fsd22 9th digit in code symbol y... -20 to +100c a... 0 to +120c (note 4) heat shock resistance 150c, 30min -40 to 100c v method v method plastic (pvc, etc.) (note 1) ?25 to ?100 mm pipe size (inner diameter) applicable pipe material mounting method fluid temper- ature range (note 3) popular type common type metal pipe (ss, steel pipe, copper pipe, aluminum pipe, etc.) (note 2) ?50 to ?100 mm flse22 plastic (pvc, etc.) (note 1) metal pipe (ss, steel pipe, copper pipe, aluminum pipe, etc.) (note 2) ?50 to ?225 mm plastic (pvc, etc.) (note 1) metal pipe (ss, steel pipe, copper pipe, aluminum pipe, etc.) (note 2) ?13 to ?100 mm fsgs3 ?50 to ?300 mm fsgs41 -40 to 80c v or z method ?200 to ?1200 mm fsgs5 ?200 to ?6000 mm fsd32 -40 to 200c ?50 to ?400 mm note 1: if the pipe material is pp or pvdf, select fsgs31, fsgs41 or fs gs5. note that the wall thickness is 15mm or less for pp, and 9mm or less for pvdf. note 2: for cast iron pipe, lining pipe, old steel pipe or others through which the ultrasonic signal could not be transmitted easily, select fsgs31,fsgs41 or fsgs50. lining material: tar epoxy, mortar, rubber, etc. * in case the lining is not glued to a pipe, the measurement ma y be impossible. straight pipe length: typically 10d for upstream and 5d for dowstream. (d: pipe inner diameter) refer to conditions on straight pipe for details (japan electric measuring instruments manufacturers' association standard jemis-032). note 3: if silicone-free grease is used as acoustic coupler, the fluid temperature range is 0 to 60c regardless of the detector. note 4: when the 9th digit in the code symbol is a, the applicable piping diameter is up to 150mm. performance s pecifications rated a ccuracy: detector flse12 2 to 32m/s plastic ?25 to ?50 mm pipe size (diameter) applicable pipe material flow velocity 2.0% of rate accuracy popular type common type 0 to 2m/s 0.04m/s metal pipe metal pipe 2 to 32m/s ?50 to ?100 mm 1.0% of rate 0 to 2m/s 0.02m/s 0 to 2m/s 2 to 32m/s ?50 to ?100 mm 2.0% of rate 0 to 2m/s 0.04m/s flse22 2 to 32m/s plastic ?50 to ?225 mm 1.0% of rate 0.02m/s 2 to 32m/s ?50 to ?225 mm 2.0% of rate 0 to 2m/s 0.04m/s 0 to 2m/s fsd22 2 to 32m/s ?13 to ?50 mm 1.5% to 2.5% of rate 0.03 to 0.05m/s 2 to 32m/s ?50 to ?100 mm 1.5% of rate 0 to 2m/s 0.03m/s 0 to 2m/s fsgs32 fsd32 fsgs51 2 to 32m/s plastic, metal pipe ?50 to below ?300 1.0% of rate 0.02m/s 0.75 to 32m/s ?300 to ?6000 mm 1.0% of rate 0 to 0.75m/s 0.0075m/s 0 to 2m/s fsgs31 fsgs41 fsgs50 2 to 32m/s ?50 to below ?300 1.5% of rate 0.03m/s 0.75 to 32m/s ?300 to ?6000 mm 1.5% of rate 0 to 0.75m/s 0.0113m/s response t ime: 0.5s (standard mode) 0.2s as selected (quick response mode) power c onsumption: 1 5va max. (ac power supply) 6 w max. (dc power supply) functional s pecifications analog s ignal: 4 to 20ma dc (1 point) l oad resistance: 1 k? max. digital o utput: f orward total, reverse total, alarm, acting range, flow switch, total switch assignable arbitrarily (1) mechanical relay contact (isolated, socket provided, arrester incorpo- rated) ? output: 1 point ? normal: open/close selectable ? contact capacity: 240v ac, 30v dc, 1a ? output frequency: 1p/s max. (pulse width: 50, 100, 200ms) (2) transistor contact (isolated, open col- lector, arrester incorporated) ? outputs: 2 points ? normal: on/off selectable ? contact capacity: 30v dc, 0.1a ? output frequency: 1000p/s max. (pulse width: 5, 10, 50, 100, 200ms) digital i nput: 1 point (no-voltage contact) (option)/ s et zero, preset total assignable serial c ommunication ( option): r s-232c equivalent or rs-485, isolated, arrester incorporated c onnectable quantity: 1 unit (rs-232c)/up to 31 units (rs-485: modbus) b aud rate: 9600, 19200, 38400bps p arity: none/odd/even selectable s top bits: 1 or 2 bits selectable 2 fsv, fls/fsg/fsd
c able length: 15m max. (rs-232c)/1km max. (rs-485) d ata: flow velocity, flow rate, forward total, reverse total, status, etc. display d evice: 2-color led (normal: green, extraordi- nary: red) l cd with 2 lines of 16 characters and back light indication l anguage: japanese (katakana)/english/french/ german/spanish (changeable) flow v elocity/flow r ate i ndication: i nstantaneous flow velocity, instantaneous flow rate indication (minus indication for reverse flow) n umerals: 8 digits (decimal point is counted as 1 digit) u nit: metric/inch system selectable metric system inch system velocity m/s ft/s flow rate l/s, l/min, l/h, l/d, k l / d , m l / d , m 3 / s , m 3 /min, m 3 /d, km 3 /d, mm 3 /d, bbl/s, bbl/ min, bbl/h, bbl/d, kbbl/d, mbbl/d gal/s, gal/min, gal/h, gal/d, kgal/d, mgal/ d, ft 3 /s, ft 3 /min, ft 3 /d, kft 3 /d, mft 3 /d, bbl/s, bbl/min, bbl/h, bbl/d, kbbl/d, mbbl/d note: the gal means usgal. total i ndication: forward or reverse total value indica- tion (negative indication for reverse direction) n umerals: 8 digits (decimal point is counted as 1 digit) u nit: metric/inch system selectable metric system inch system total ml, l, m 3 , km 3 , mm 3 , mbbl, bbl, kbbl gal, kgal, ft 3 , kft 3 , mft 3 , mbbl, bbl, kbbl, acre-ft configuration: fully configurable from the 4-key pad (esc, , , ent) zero a djustment: set zero/clear available external z ero a djustment: set zero available upon digital input setting damping: 0 to 100s (every 0.1s) for analog output and flow velocity/flow rate indication low f low r ate c utoff: 0 to 5m/s in terms of flow velocity alarm: digital output available for hardware fault or process fault burnout: analog output: hold/overscale/under- scale/zero selectable f low rate total: hold/count selectable b urnout timer: 0 to 100s (every 1s) bi-directional r ange: forward and reverse ranges configu- rable independently. h ysteresis: 0 to 10% of working range w orking range applicable to digital output auto-2 r ange: 2 forward ranges configurable indepen- dently h ysteresis: 0 to 10% of working range w orking range applicable to digital output flow s witch: lower limit, upper limit configurable independently d igital output available for status at actuated point total s witch: forward total switching point configu- rable d igital output available when actuated external t otal p reset: preset total settable upon contact input setting physical s pecifications type o f e nclosure: f low transmitter: f svs: ip66 f svh: ip67 (with l arge lcd) d etector: f ls (popular type): i p65 (when waterproot bnc con- nector is provided) f sg (common type): i p67 (silicone compound is filled on the terminal part when wiring) f sg (submersible type): i p68 (submersible in water for 5 days) f sd (small diameter and high tempera- ture type): ip52 mounting m ethod: flow transmitter: mounted on wall or by 2b pipe detector: clamped on pipe surface acoustic c oupler: s ilicone rubber, silicone grease or silicone- free grease note: the acoustic coupler is a medium that eliminates a gap between detector and pipe type of acoustic coupler: type 0 to +60c silicone rubber (ke-348w) silicone grease (g40m) silicone-free grease (high z) -30 to +250c grease for high temperature (ks62m) -30 to +150c -40 to +150c fluid temperature teflon piping in case of teflon piping, use grease. procure silicone grease (g40m), if necessary, as an optional accessory. material: flow transmitter: aluminum alloy d etector: detector sensor housing sensor cover sus304 guide rail pbt flse1 sus304 pbt flse2 aluminum alloy + plastic pbt fsd22 sus304 C pbt fsgs41 fsgs5 sus304 sus304 + plastic pbt fsgs3 C C C C sus304 + aluminum alloy sus304 fsd32 3
measuring principle with ultrasonic pulses propagated diagonally between the upstream and downstream sensors, flow rate is measured by detecting the time difference obtained by the flow of fluid. detector flow velocity t 1 t 2 flow transmitter output signal detector detector cable cable dc 4 to 20ma digital signal (up to 2 point) dc 4 to 20ma digital signal (up to 2 point) upstream sensor downstream sensor ultra sonic oscillator plastic wedge pipe lining flow transmitter flow transmitter d mounting of detector configuration diagram (1) s ingle-path s ystem ( v m ethod) (2) s ingle p ath s ystem ( z m ethod) signal c able: f ly3 (applicable detector: fls) ? s tructure: heat-resisting high-frequency coaxial cable (3d2v) ? s heath: flame-resisting pvc ? o uter diameter: ?5mm ? t ermination: m3 amp terminal (flow transmitter side) and bnc connector (sensor side) f ly8, fly9 (applicable detector: fsg, fsd) ? s tructure: high frequency coaxial cable (double shield) ? s heath: black flame-resisting pvc ? o uter diameter: ?7.3mm ? t ermination: m3 amp terminal (flow transmitter side) and m4 amp terminal (fly8).note, however, that the detecter side of fsd22 and fsd32 is provided with bnc connector (fly9). ? m ass: approx. 90g/m dimensions: flow transmitter fsvs (ip66): h170w142d70mm flow transmitter fsvh (ip67): h277w244d95mm d etector: h50w228d34mm (flse1) h50w348d34mm (flse2) h90w320d53mm (fsd22) h46w410d50mm (fsgs3) h46w54d37mm (fsgs41) h67w78d84mm (fsgs5) h 205w530d52mm (fsd32) mass: flow transmitter (indoor type): 1 .5kg flow transmitter (outdoor type): 4 .5kg d etector: 0 .3kg (flse1) 0 .4kg (flse2) 0 .6kg (fsd22) 0 .6kg (fsgs3) 0 .3kg (fsgs4) 1 .2kg (fsgs5) 1 .6kg (fsd32) p c l oader s oftware provided as standard ?compatible model is pc/at compatible instrument. ?operation is undefined for pc98 series (nec). ?main functions: software for main unit parameter set- ting/change on pc ?os: windows 2000/xp ?memory requirement: 125mb min. ?disk unit: cd-rom drive compatible with windows 2000/xp ?hard disk capacity: minimum vacant capacity of 52mb or more note: o ptional communication board (specified at the 5 th digit of code symbols) and loader cable (model zzp * tk4j1236) are additionally necessary for rs232c serial communication. note: u sb-rs232c converter f or pc that does not support rs-232c serial interface, a converter is necessary for connecting the pc and main unit. u sb-rs232c converter should be combined with the above loader cable. < recommendation> u sb-cvrs9 (manufactured by sanwa supply) 4 fsv, fls/fsg/fsd
detector selection guide note: the ultrasonic signal cannot be transmitted easily when the classification of piping material is px or the turbidity is high. in such a case, a preliminary check by a portable ultrasonic f lowmeter is recommended. fsgs41 z v v fsgs51 note) fsgs50 fsd22 v fsd32 z v z v v v fsgs32 note) fsgs31 flse12 2-y -40 to 80 -40 to 100 -40 to 200 -20 to 100 0 to 120 13 25 50 100 200 300 400 1000 3000 6000 px : pp, pvdf p : plastic (pvc, etc.) m : msetallic piping (steel pipe, copper pipe, aluminum, etc.) classification of piping materials 250 type fluid temperature [c] mounting method p p, m px, p, m px, p, m px, p, m px, p, m px, p, m px, p, m px, p, m px, p, m m 25 100 100 100 13 50 50 50 50 150 400 250 200 1200 200 200 3000 6000 200 600 225 p, m 50 150 300 -20 to 100 0 to 120 flse12 2-a flse22 2-y flse22 2-a inner diameter of piping ? (mm) code symbol 1 y f s v y description 1 2 3 4 5 6 7 8 9 10 11 12 13 14 (destination) (4th digit) standard (english) (communication) (5th digit) none rs232c+di rs485+di (use) (6th digit) single measuring path (power supply) (7th digit) ac100 to 240v 50/60hz dc20 to 30v (case structure) (9th digit) ip66 ip67 (wire connection port) (10th digit) weatherproof gland provided [g1/2 and g3/8 (internal threads)] union (for pilica) with gland [g1/2 female screw] (when "h" is specified 9th digit) (combination with explosion-proof detector) (11th digit) none (parameter setting) (12th digit) none setting provided setting provided + tag tag (mounting method) (13th digit) pipe mount (if the 9th digit is s) wall mount pipe mount (if the 9th digit is h) (area) (14th digit) america europe, middle east, africa asia e y a s h 1 4 y y a b y y a b c a b c n e a 1 %ftdsjqujpo 1 2 3 4 5 6 7 8 small diameter sensor (?13 to ?100) v method high-temperature sensor * 1 (?50 to ?400) v or z method 2 2 0 s 1 3 2 0 f s d f s d y *1: note: as standard acoustic coupler, silicone rubber (ke-348w) is provided for small diameter sensor, or grease for high temperature (ks62m) for high-temperature sensor. for turbid fluid or old pipe, cast iron pipe, mortar lining pipe or others through which the ultrasonic signal could not be transmitted easily, use an optional guide rail (tk4c6164c1), and carry out mounting by z method. applicable diameter range v method: ?50 to ?250 z method: ?150 to ?400 5
code symbol description type (5th and 6th digits) small sensor 2mhz (?50 to ?300) small sensor 1mhz (?50 to ?300)* 2 middle sensor 1mhz (?200 to ?1200) large sensor 1mhz (?200 to ?6000) large sensor 0.5khz (?200 to ?6000)* 2 acoustic coupler (10th digit) none * 5 silicon rubber (ke348) silicone-free grease (high-z) (note 2) silicone grease (g40m) (note 2) additional specification (11th digit) none tag plate wire rope for mounting (12th digit) specify it in the case of fsgs41 or fsgs5. none nominal diameter: up to ?500mm nominal diameter: up to ?1000mm nominal diameter: up to ?1500mm nominal diameter: up to ?3000mm nominal diameter: up to ?6000mm 1 f s g s yy 1 1 2 3 4 5 6 7 8 9 10 11 12 13 y a b c 3 2 3 1 4 1 5 1 5 0 y a y a b c d e v method v or z method can be specified only for fsgs5 *2: *3: *5: for aging pipes, cast iron pipes or mortar-lined pipes that interrupts the propagation of ultrasonic signals, select fsgs31 or fsgs50. procure type fly for the signal cable. silicone rubber (ke-348w) is provided as a standard accessory to fill the wiring mold. (it can also be used as an acoustic coupler.) if an additional acoustic coupler is required, select one among a, b and c. description 1 f s g s a 1 1 2 3 4 5 6 7 8 9 10 11 12 13 a c b c d e f g h j k l m n p q r z 3 2 3 1 4 1 5 1 5 0 y a y a b c d e dedicated signal cable (9th digit) 10m 20m 30m 40m 50m 60m 70m 80m 90m 100m 110m 120m 130m 140m 150m specified length (contact us if length is more than 150m. max. length is 300m.) type (5th and 6th digits) small sensor 2mhz (?50 to ?300) small sensor 1mhz (?50 to ?300)* 2 middle sensor 1mhz (?200 to ?1200) large sensor 1mhz (?200 to ?6000) large sensor 0.5khz (?200 to ?6000)* 2 acoustic coupler (10th digit) silicon rubber (ke348) silicone grease (g40m) (note 2) additional specification (11th digit) none tag plate wire rope for mounting (12th digit) specify it in the case of fsgs41 or fsgs5. none nominal diameter: up to ?500mm nominal diameter: up to ?1000mm nominal diameter: up to ?1500mm nominal diameter: up to ?3000mm nominal diameter: up to ?6000mm v method v or z method can be specified only for fsgs5 *2: for aging pipes, cast iron pipes or mortar-lined pipes that interrupts the propagation of ultrasonic signals, select fsgs31 or fsgs50. 3 f l s e description 1 2 3 4 5 6 7 8 9 10 type (4th, 5th and 6th digits) small diameter sensor, 2mnz (?25 to ?100mm) small sensor, 2mhz (?50 to ?225mm) (note 1) acoustic coupler (7th digit) (note 2) none silicone rubber silicone-free grease 1 2 2 2 y a b y a optional specification (10th digit) none tag y b fluid temperature range (9th digit) -20 to +100c 0 to +120c v method note 2: normally select silicone rubber as acoustic coupler. silicone rubber in tube (100g) is furnished. if you place an order for several units, 1 tube may suffice for every 5 units. select silicone-free grease for semiconductor manufacturing equipment or the like that is vulnerable to silicone. the silicone-free grease is water-soluble and, therefore, cannot be used in environment exposed to water or on piping subjected to a condensation. since the grease does not set, a periodic maintenance (cleaning, refilling every about 6 months at normal temperature) is necessary. note 1: when the 9th digit in the code symbol is a, the applicable piping diameter is up to 150mm. 6 fsv, fls/fsg/fsd
code symbol ? f or d etector f ls f 1 description l y 1 2 3 4 5 6 7 8 f 1 description l y 1 2 3 4 5 6 7 8 type of sensor (4th digit code) (for fls) cable length (5, 6 and 7th digit) 5 m 10 m 15 m 20 m 25 m 30 m 40 m 50 m 60 m others (contact us) 0 0 5 0 1 0 0 1 5 0 2 0 0 2 5 0 3 0 0 4 0 0 5 0 0 6 0 z z z 3 type of sensor (4th digit) small and large sensor (for fsg) small dia and hight temp sensor (for fsd) cable length (5,6 and 7th digit) 5 m 10 m 15 m 20 m 25 m 30 m 35 m 40 m 45 m 50 m 55 m 60 m 65 m 70 m 75 m 80 m 85 m 90 m 95 m 100 m 110 m 120 m 130 m 140 m 150 m others (contact us) 0 0 5 0 1 0 0 1 5 0 2 0 0 2 5 0 3 0 0 3 5 0 4 0 0 4 5 0 5 0 0 5 5 0 6 0 0 6 5 0 7 0 0 7 5 0 8 0 0 8 5 0 9 0 0 9 5 1 0 0 1 1 0 1 2 0 1 3 0 1 4 0 1 5 0 z z z 8 9 note: must be procured unless the sensor is a submersible type. ? f or d etector f sg a nd f sd conditions o n s traight p ipe l 10d detector in case that flow control valve exists on upstream side. in case that flow control valve exists on downstream side. 1.5d 0.5d or more 10d or more 10d or more d check valve p stop valve 10d or more 90 bend tee diffuser reducer various valve pump (note) the source : jemis-032 classification upstream side downstream side ( d : inside diameter of pipe) l 50d l 30d l 10d l 30d l 50d l 10d l 50d l 5d l 10d l 5d 7
outline diagram (unit:mm) flow transmitter : fsvs (ip66) flow transmitter : fsvh (ip67) pipe size (mm) 25 to 100 50 to 225 l 228 348 spacing 21 to 120 21 to 240 0.3 0.4 mass. approx (kg) sensor bnc connector frame lock clip h 31 30 type flse12 flse22 spacing (adjustable every 3mm) ss tag (option) l h (50) 34 28 detecter (type : flse 2) (popular type) mtg. hole mtg. plate ss tag (option) earth terminal (m4) for sensor cable (pf3/8) for power supply & output cable (pg13.5) cable gland mtg. pipe u bolt (m8) (option) ultrasonic flow meter ent esc delta-c time 2.5 2.5 75 142 701 1 10 170 200 (233) 153 10 9 39 40 40 40 40 5.7 95 14 230 220 312 277 2- ? 9 20 25 72 mtg. pipe bracket (option) u bolt (m8) (option) for power supply & output cable (pf1/2) for sensor cable (pf1/2) earth terminal (m4) 8 fsv, fls/fsg/fsd
outline diagram (unit:mm) detector fsd22 (small diameter sensor) connector saddle lock nut element holder cursor mm inch scale (inch) scale (mm) distance between two sensors 0 to 133 320 36 52.5 90 max. detector fsgs5 (large sensor) detector fsgs3 (small sensor) detector fsd32 (high-temperature sensor) sensor 841 781 114 671 ?19 mounting spring wire rope name plate sensor wire rope mounting spring name plate 781 l(cable length (m) : specified by order) ?19 841 114 671 sensor chain frame name plate spacing : 0 to 270 view from p p mounting spring frame guide 410 2 400 5 5 47 501 33 461 (10) sensor chain frame name plate spacing : 0 to 270 view from p p mounting spring frame guide 410 2 400 5 5 47 501 33 461 (10) l (cable length (m) : specified by order) (common type) (submersible type) (common type) (submersible type) cursor name plate 205max. 26 44 1 530 2 90max. 33 0.5 element holder lock nut saddle connector scale(inch) scale(mm) distance between two sensors 0 to 330 s
outline diagram (unit:mm) signal cable : fly3 (for fls) signal cable : fly8 (for fsg) signal cable : fly9 (for fsd) loader cable : zzp*tk4j1236 ?15 ?5 41 l (cable length (m) : specified by order) bnc connector 5.5 ?3.2 l : by specification when ordered. to detector to flow transmitter 5.5 8 l (cable length (m) : specified by order) l : by specification when ordered. to detector to flow transmitter 3-?4.3 3-?3.2 ?11 ?7.3 30 5.5 l (cable length (m) : specified by order) bnc connector l : by specification when ordered. to detector to flow transmitter ?11 ?7.3 ?14.5 30 3-? 3.2 5.5 to personal computer to flow transmitter rs-232c terminal cap (red) terminal cap (yellow) terminal cap (black) red txd yellow rxd black com connector 3-? 3.2 34 46 67 3.20.2 (m) ?6.9 detector fsgs41 (middle sensor) sensor mounting spring wire rope name plate 541 114 371 461 ?19 sensor mounting spring wire rope name plate 541 114 l (cable length (m) : specified by order) 371 461 ?19 (common type) (submersible type) 10 fsv, fls/fsg/fsd
connection diagram name drawing no. 1 2 3 4 5 6 7 8 9 zzp*tk4c6164c1 zzp*tk4j1236c1 zzp*45231n5 zzp*45735n2 zzp*tk7m0981p1 zzp*tk7g7983c1 zzp*tk7n3827p8 zzp*tk7j1005p1 zzp*tk745007p1 zzp*tk464686c1 zzp*tk464686c2 zzp*tk464686c3 zzp*tk464686c6 zzp*tk464686c13 guide rail for high-temperature sensor pc loader cable silicon grease (g40m) silicone rubber (ke 348w) silicone-free grease (high z) high-temperature grease (ks62m) fuse for ac power fuse for dc power wire rope for mounting the sensor spring wire rope nomal diameter: up to ?500mm nomal diameter: up to ?1000mm nomal diameter: up to ?1500mm nomal diameter: up to ?3000mm nomal diameter: up to ?6000mm g + to flow transmitter 432 n 1 l 43 ? 21 + dc20 to 30v 4 txdr1 321 shild rs-485 txdr2 4 txd 321 di1 gnd rxd rs-232c 4 5 321 + ? ? + do1 tr out do2 tr out do3 relay + ? 6 7 + ? 8 9 i out gnd 10 hf1 11 hf2 gnd 1312 di1 max. dc30v, 0.1a max. ac240v/ dc30v, 1a status input (di) ac power supply dc power supply option status input (di) to upstream-side sensor to downstream-side sensor sh * 1 earth terminal (m4) sh * 1 ac100 to 240v 50/60hz *1) only for double shield coaxial cable (type fly8, 9) scope of delivery ?flow transmitter (provided with u-bolt and nuts for pipe mount) ?detector (provided with mounting fixture and acoustic coupler) *the acoustic coupler is option for popular type detec- tors. ?signal cable ?cd-rom (contains instruction manual, loader software) items designated ordering 1. d etector code symbols 2. f low transmitter code symbols 3. s ignal cable code symbols 4. f or large sensor: mounting pipe size 5. t ag no. as necessary 6. i f parameter setting is specified, send back the attached parameter specification table duly filled. optional accessories 11
fsv, fls/fsg/fsd printed in japan caution on safety *before using this product, be sure to read its instruction manual in advance. international sales div sales group gate city ohsaki, east tower, 11-2, osaki 1-chome, shinagawa-ku, tokyo 141-0032, japan http://www.fujielectric.com phone: 81-3-5435-7280, 7281 fax: 81-3-5435-7425 http://www.fjielectric.com/products/instruments/ information in this catalog is subject to change without notice. setting item initial value setting value setting item initial value setting value id no 0000 total mode stop language english system unit metric flow unit m 3 /h total unit m 3 outer diameter 60.00mm pipe material pvc pipe wall thickness 4.00mm lining material without lining lining thickness ? kind of fluid water viscosity 1.003810 - 6 m 2 /s sensor mount v metod sensor type fls_12 transmission voltage 80vpp damping 5.0sec cut off 0.150m 3 /h 1st line flow velocity (m/s) 1st line decimal point position ****.*** 2nd line flow rate ( m 3 /h ) 2nd line decimal point position ****.*** range type single range full scale 1 15.000m 3 /h full scale 2 0.000m 3 /h range hys. 10.00% burnout (current) hold burnout timer 10sec output low limit - 20% output high limit 120% rate limit 0.000m 3 /h rate limit timer 0sec total rate 0m 3 total preset 0m 3 pulse width 50.0msec burnout (total) hold burnout timer 10sec do1 output type (note 1) not used do1 output actuation on when actuated do2 output type not used do2 output actuation on when actuated do3 output type not used do3 output actuation on when actuated di1 input type not used di1 input actuation on when actuated operation mode standard communication mode rs-232c baud rate 9600bps parity odd stop bit 1 bit station no. 1 note1: when total pulse output has been selected for do1, do2 or do3 s pecify total pulse value and total pulse width so that conditions 1 and 2 shown below are satisfies. * in the case of 2 ranges, perform calculations using either fl ow span-1 or flow span-2, whichever is greater. condition 1 : 1000 [in the case of do1 and do2] 1 [in the case of do3] flow span-1*[m 3 /s] total pulse value*[m 3 ] condition 2 : flow span-1*[m 3 /s] total pulse value*[m 3 ] 1000 2 total pulse width [ms] measuring conditions output conditions display analog output communication output conditions total output


▲Up To Search▲   

 
Price & Availability of EDSX6-140D

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X