If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
? s14062 LSI40909G-S pci to fibre channel host adapter for sun solaris users guide february 2001 version 1.0
ii electromagnetic compatibility notices this device complies with part 15 of the fcc rules. operation is subject to the following two conditions: 1. this device may not cause harmful interference, and 2. this device must accept any interference received, including interference that may cause undesired operation. this equipment has been tested and found to comply with the limits for a class b digital device, pursuant to part 15 of the fcc rules. these limits are designed to provide reasonable protection against harmful interference in a residential installation. this equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. however, there is no guarantee that interference will not occur in a particular installation. if this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: reorient or relocate the receiving antenna. increase the separation between the equipment and the receiver. connect the equipment into an outlet on a circuit different from that to which the receiver is connected. consult the dealer or an experienced radio/tv technician for help. shielded cables for scsi connection external to the cabinet are used in the compliance testing of this product. lsi logic is not responsible for any radio or television interference caused by unauthorized modi?cation of this equipment or the substitution or attachment of connecting cables and equipment other than those speci?ed by lsi logic. the correction of interferences caused by such unauthorized modi?cation, substitution, or attachment will be the responsibility of the user. the lsi logic LSI40909G-S is tested to comply with fcc standards for home or of?ce use. this class b digital apparatus meets all requirements of the canadian interference-causing equipment regulations. cet appareil numrique de la classe b respecte toutes les exigences du rglement sur le matriel brouilleur du canada. this is a class b product based on the standard of the voluntary control council for interference from information technology equipment (vcci). if this is used near a radio or television receiver in a domestic environment, it may cause radio interference. install and use the equipment according to the instruction manual. lsi logic corporation north american headquarters milpitas, ca 408.433.8000 iii this document contains proprietary information of lsi logic corporation. the information contained herein is not to be used by or disclosed to third parties without the express written permission of an of?cer of lsi logic corporation. lsi logic products are not intended for use in life-support appliances, devices, or systems. use of any lsi logic product in such applications without written consent of the appropriate lsi logic of?cer is prohibited. document db14-000180-00, first edition (february 2001). this document describes the lsi logic LSI40909G-S pci to fibre channel host adapter for sun solaris and will remain the of?cial reference source for all revisions/releases of this product until rescinded by an update. to receive product literature, visit us at http://www.lsilogic.com. lsi logic corporation reserves the right to make changes to any products herein at any time without notice. lsi logic does not assume any responsibility or liability arising out of the application or use of any product described herein, except as expressly agreed to in writing by lsi logic; nor does the purchase or use of a product from lsi logic convey a license under any patent rights, copyrights, trademark rights, or any other of the intellectual property rights of lsi logic or third parties. copyright ? 2001 by lsi logic corporation. all rights reserved. trademark acknowledgment the lsi logic logo design, metastor, and fusion-mpt are registered trademarks or trademarks of lsi logic corporation. sun and solaris are trademarks or registered trademarks of sun microsystems, inc. all other brand and product names may be trademarks of their respective companies. db iv preface v preface this book is the primary reference and users guide for the lsi logic LSI40909G-S pci to fibre channel host adapter for sun solaris board. it contains a complete functional description for the LSI40909G-S as well as complete physical and electrical speci?cations. audience this document assumes that you have some familiarity with fibre channel protocol and related support devices and will bene?t persons installing and using the LSI40909G-S. organization this document has the following chapters and appendix: chapter 1, LSI40909G-S description , de?nes the interfaces and characteristics of the LSI40909G-S. chapter 2, installing the LSI40909G-S , provides both quick and detailed installation instructions. chapter 3, software installation , describes the installation procedures for the fusion-mpt and fibre channel drivers. chapter 4, LSI40909G-S technical characteristics , describes the physical and operational environments of the LSI40909G-S. appendix a, glossary of terms and abbreviations , provides de?nitions of various terminology that is referenced throughout this users guide. vi preface related publications lsifc909 fibre channel i/o processor technical manual, order number s14029.a revision record revision date remarks 1.0 02/01 first printing. contents vii contents chapter 1 LSI40909G-S description 1.1 general description 1-1 1.2 features 1-1 1.2.1 pci interface 1-1 1.2.2 fc interface 1-2 1.2.3 board characteristics 1-2 1.2.4 fc link activity/link fault led 1-3 chapter 2 installing the LSI40909G-S 2.1 quick installation procedure 2-1 2.2 detailed installation procedure 2-2 2.2.1 before you start 2-2 2.2.2 inserting the host adapter 2-2 chapter 3 software installation 3.1 installing the sun sparc solaris fusion-mpt? drivers 3-1 3.1.1 features 3-2 3.1.2 system requirements 3-2 3.1.3 verifying correct installation 3-2 3.1.4 identifying the fc disks 3-4 3.1.5 persistent device naming 3-5 3.1.6 itmpt device driver 3-7 3.2 installing the itmpt sun sparc solaris fc driver 3-7 3.2.1 existing system installation 3-7 3.2.2 network installation procedure 3-12 3.3 troubleshooting 3-15 viii contents chapter 4 LSI40909G-S technical characteristics 4.1 physical environment 4-1 4.1.1 physical characteristics 4-1 4.1.2 electrical characteristics 4-2 4.1.3 thermal, atmospheric characteristics 4-2 4.1.4 electromagnetic compliance 4-3 4.1.5 safety characteristics 4-3 4.2 operational environment 4-3 4.2.1 the pci interface 4-3 4.2.2 the fc interface 4-4 4.2.3 the fc link activity/link fault led 4-4 4.3 ieee unique address 4-4 appendix a glossary of terms and abbreviations customer feedback figures 2.1 hardware connections for the LSI40909G-S 2-4 2.2 inserting the host adapter 2-5 3.1 system devices listing 3-3 3.2 fc disk devices listing 3-4 3.3 persistent device mapping 3-6 3.4 clearing an entry 3-7 3.5 pkgadd procedure 3-9 3.6 completing floppy disk installation 3-10 3.7 completing floppy disk installation (continued) 3-10 3.8 /kernel/drv/ssd.conf 3-11 4.1 LSI40909G-S components 4-2 tables 3.1 resource requirements 3-2 3.2 error messages 3-15 LSI40909G-S pci to fibre channel host adapter for sun solaris 1-1 3.75 pc 10.25 pc 11.25 pc 38.25 pc 4.333 pc 12 pc 12.938 pc 13.851 pc 48.583 pc 52.5 pc 34.5 pc 34.732 pc chapter 1 LSI40909G-S description this chapter describes the LSI40909G-S pci to fibre channel (fc) host adapter board and includes these topics: section 1.1, general description, page 1-1 section 1.2, features, page 1-1 1.1 general description the lsi logic LSI40909G-S provides an fc interface to sun solaris pci computer systems. this board is referred to as the LSI40909G-S throughout this guide. the LSI40909G-S uses the lsifc909 fc i/o processor chip. 1.2 features this section provides an overview of the pci interface , the fc interface , and board characteristics for the LSI40909G-S. 1.2.1 pci interface pci interfaces i/o components to the processor and memory subsystems in equipment ranging from pcs to servers. the pci interface operates as a 64-bit dma bus master capable of 64-bit addressing. the lsifc909 contains the pci functionality for the LSI40909G-S. 3.75 pc 10.25 pc 11.25 pc 38.25 pc 4.333 pc 48.583 pc 52.5 pc 34.5 pc 44.25 pc 1-2 LSI40909G-S description the pci interface includes these features: full 64-bit dma bus master lsifc909 functionality: C zero wait-state bus master data bursts up to 1 kbyte C complies with pci local bus speci?cation, revision 2.2 C 3.3 v interface (5.0 v tolerant) serial eeprom con?guration storage card edge keyed as a universal add-in card 1.2.2 fc interface the lsifc909 contains the fc functionality for the LSI40909G-S. the lsifc909 generates signal timing and link protocol in compliance with fc standards. the fc interface includes these features: 1 gigabit giga-bit interface converter (gbic) connection lsifc909 functionality: C class 3, arbitrated loop (al) C 2 kbyte frame payloads C multiframe buffering 1 gigabit/s serial link link fault led 1.2.3 board characteristics the LSI40909G-S board characteristics are: pci board dimensions: 168 x 98 mm (6.625 x 3.875 inches) pci universal 64-bit card edge connector fc link activity led in chapter 4, LSI40909G-S technical characteristics, figure 4.1 illustrates the mechanical drawing for this host adapter board. 3.75 pc 10.25 pc 11.25 pc 38.25 pc 4.333 pc 48.583 pc 52.5 pc 34.5 pc 44.25 pc features 1-3 1.2.4 fc link activity/link fault led the LSI40909G-S provides a dual-purpose led visible through the bracket which indicates activity on the fc link when the led is green. this led turns yellow when there has been a fault on the fc link. 3.75 pc 10.25 pc 11.25 pc 38.25 pc 4.333 pc 48.583 pc 52.5 pc 34.5 pc 44.25 pc 1-4 LSI40909G-S description LSI40909G-S pci to fibre channel host adapter for sun solaris 2-1 3.75 pc 10.25 pc 11.25 pc 38.25 pc 4.333 pc 12 pc 12.938 pc 13.851 pc 48.583 pc 52.5 pc 34.5 pc 34.732 pc chapter 2 installing the LSI40909G-S this chapter provides instructions on how to install the LSI40909G-S and includes these topics: section 2.1, quick installation procedure, page 2-1 section 2.2, detailed installation procedure, page 2-2 2.1 quick installation procedure this section provides an overview of the installation procedure. if you are an experienced computer user with prior host adapter installation and fc setup experience, this section may suf?ciently describe the procedure for you. if you prefer a more detailed guidance for installing the LSI40909G-S, proceed to section 2.2, detailed installation procedure. for safe and proper installation, check the users manual supplied with your computer and perform the following steps. step 1. ground yourself before removing this host adapter board. step 2. remove the LSI40909G-S from the packing and check that it is not damaged. figure 2.1 illustrates an example of this host adapter board. also refer to figure 4.1 on page 4-2 to see a more detailed drawing of this board. step 3. open your pc cabinet and select an appropriate open pci slot. step 4. insert the host adapter board. step 5. make any con?guration changes. step 6. close your pc cabinet cover. step 7. connect the fc cable to the LSI40909G-S. 3.75 pc 10.25 pc 11.25 pc 38.25 pc 4.333 pc 48.583 pc 52.5 pc 34.5 pc 44.25 pc 2-2 installing the LSI40909G-S 2.2 detailed installation procedure this section provides step-by-step instructions for installing the LSI40909G-S. if you are experienced in these tasks, you may prefer to use section 2.1, quick installation procedure. 2.2.1 before you start before starting, look through the following task list to get an overall idea of the steps you will be performing. if you are not con?dent you can perform the tasks as described here, lsi logic recommends getting assistance. each fc host adapter that you install can act as host for up to 126 arbitrated loop fc devices, not including the adapter itself. follow the detailed instructions in the next section to successfully install the host adapter board. 2.2.2 inserting the host adapter for safe and proper installation, use the users manual supplied with your computer. perform the following steps to install the LSI40909G-S. step 1. ground yourself before removing this host adapter board. step 2. remove the LSI40909G-S from the packing and check that it is not damaged. figure 2.1 illustrates an example of this host adapter board. also refer to figure 4.1 on page 4-2 to see a more detailed drawing of this board. step 3. switch off the computer and unplug power cords for all components in your system. step 4. remove the cover from your computer per the instructions in the users manual for your system to access the pci slots. caution: ground yourself by touching a metal surface before removing the cabinet top. static charges on your body can damage electronic components. handle plug-in boards by 3.75 pc 10.25 pc 11.25 pc 38.25 pc 4.333 pc 48.583 pc 52.5 pc 34.5 pc 44.25 pc detailed installation procedure 2-3 the edge; do not touch board components or gold connector contacts. the use of a static ground strap is recommended. step 5. locate the slots for pci plug-in board installation. refer to the computers users manual to con?rm the location of the pci slots. the LSI40909G-S requires a 32-bit or 64-bit pci slot that allows bus master operation. if a 32-bit pci slot is used, the portion of the j1 connector opposite the bracket remains uninserted. see figure 2.2 . note : for the LSI40909G-S to function as a 64-bit device, it must be inserted in a 64-bit pci slot. if the LSI40909G-S is inserted in a 32-bit pci slot, it will function as a 32-bit device. step 6. remove the blank bracket panel on the back of the computer aligned with the pci slot you intend to use. save the bracket screw. 3.75 pc 10.25 pc 11.25 pc 38.25 pc 4.333 pc 48.583 pc 52.5 pc 34.5 pc 44.25 pc 2-4 installing the LSI40909G-S figure 2.1 hardware connections for the LSI40909G-S step 7. carefully insert edge connector j1 (see figure 2.1 ) of the host adapter into the pci slot. make sure the edge connector is properly aligned before pressing the board into place as shown in figure 2.2 . the bracket around connector j2 should ?t where you removed the blank panel. gbic connector j2 fibre channel link activity/ link fault led LSI40909G-S pci bus edge connector j1 3.75 pc 10.25 pc 11.25 pc 38.25 pc 4.333 pc 48.583 pc 52.5 pc 34.5 pc 44.25 pc detailed installation procedure 2-5 figure 2.2 inserting the host adapter step 8. secure the board with the bracket screw (see figure 2.2 ) before making the external fc link connection. step 9. connect the fc cable to the LSI40909G-S. 32-bit pci slots 64-bit pci slots bracket screw 3.75 pc 10.25 pc 11.25 pc 38.25 pc 4.333 pc 48.583 pc 52.5 pc 34.5 pc 44.25 pc 2-6 installing the LSI40909G-S LSI40909G-S pci to fibre channel host adapter for sun solaris 3-1 chapter 3 software installation this chapter describes the features and use of the lsi logic/intraserver device drivers for the solaris operating system 2.6, 2.7, and 2.8. this chapter includes these topics: section 3.1, installing the sun sparc solaris fusion-mpt? drivers, page 3-1 section 3.2, installing the itmpt sun sparc solaris fc driver, page 3-7 section 3.3, troubleshooting, page 3-15 for the most up-to-date information on drivers, please visit: http://www.intraserver.com/support/drivers.html 3.1 installing the sun sparc solaris fusion-mpt? drivers the lsi logic LSI40909G-S offers the highest possible performance on sun solaris systems. the lsi logic fusion-mpt fc driver (itmpt) is optimized for low cpu overhead and high i/o throughput, making use of the lsi logic fusion-mpt architecture. the lsi logic fc adapters have built-in fcode, designed to operate in the sun openboot environment, allowing fc devices to be available to the openboot ( ok ) prompt. the lsi logic driver, itmpt, allows the solaris operating system to interface with fc devices connected to the LSI40909G-S. this driver takes advantage of new hardware features in the LSI40909G-S to minimize cpu utilization, including interrupt coalescing, which can result in less than one interrupt per i/o. 3-2 software installation 3.1.1 features the following features of the LSI40909G-S minimize cpu utilization: uses state of the art fusion-mpt interface, providing support for fc, scsi, and raid devices with a single binary image. provides highly ef?cient, low cpu usage architecture. multiport functionality minimizes slot usage. 66 mhz/64-bit pci interface provides maximum i/o bandwidth. supports multiple host adapters. supports scatter/gather. supports multiprocessor environments. 3.1.2 system requirements your sparc solaris system must have the available resources as listed in table 3.1 in order to install the LSI40909G-S. after installing the module in an appropriate pci slot and making all the necessary internal and external connections to the module, power on the host system. 3.1.3 verifying correct installation use this procedure to verify installation of your lsi logic/intraserver fc adapter before booting your system: step 1. power on the system. table 3.1 resource requirements resource requirement host bus slot sun solaris system with available pci slot operating system solaris 2.6 release or later network boot server sparc or intel solaris boot server 1 1. only required if you will be using the lsi logic module to support your system disk. firmware openboot prom version 3.0 or greater installing the sun sparc solaris fusion-mpt? drivers 3-3 step 2. when the banner is displayed, press the stop-a keys to interrupt the boot process and stop at the ok prompt. step 3. use the show-devs command to list the system devices. you should see an output similar to the following example, as shown in figure 3.1 : figure 3.1 system devices listing note: /pci@1f,0/pci@1/pci@2/intraserver,fc@4 identi?es the ?rst fc interface on an lsi logic/intraserver 7000 series adapter. the above is an example. the output of show-devs may vary depending on your system and con?guration. use the corresponding entries on your system, not those given here. if these devices are not listed, check that the adapter is correctly installed, and reseat the adapter if necessary. ok show-devs /sunw,ultrasparc-iii@0,0 /pci@1f,0 /virtual-memory /memory@0,10000000 /aliases /options /openprom /chosen /packages /pci@1f,0/pci@1 /pci@1f,0/pci@1,1 /pci@1f,0/pci@1/pci@2 /pci@1f,0/pci@1/intraserver,ultra2-scsi@1 /pci@1f,0/pci@1/pci@2/intraserver,fc@4 /pci@1f,0/pci@1/pci@2/intraserver,fc@4/disk /pci@1f,0/pci@1/pci@2/intraserver,fc@4/tape /pci@1f,0/pci@1/intraserver,ultra2-scsi@1/tape /pci@1f,0/pci@1/intraserver,ultra2-scsi@1/disk /openprom/client-services 3-4 software installation 3.1.4 identifying the fc disks the probe-scsi-all command is used to identify the fc disk devices on your lsi logic/intraserver adapter, as shown in figure 3.2 . figure 3.2 fc disk devices listing ok probe-scsi-all /pci@1f,0/pci@1/intraserver,ultra2-scsi@1 target 0 unit 0 disk ibm dnes-309170w sa30 /pci@1f,0/pci@1/pci@2/intraserver,fc@7 mpt firmware version 1.00 target 0 unit 0 disk seagate st39173fc 6615 wwn 220000203710d063 id 111d2 target 1 unit 0 disk seagate st39173fc 6258 wwn 220000203710c09b id 111d6 target 2 unit 0 disk seagate st39173fc 6258 wwn 220000203710b066 id 111d5 target 3 unit 0 disk seagate st39173fc 6258 wwn 220000203710b063 id 111d3 target 4 unit 0 disk seagate st39173fc 6258 wwn 220000203710b04f id 111d4 target 5 unit 0 disk seagate st39173fc 6615 wwn 2200002037104f73 id 111d9 target 6 unit 0 disk seagate st39173fc 6615 wwn 2200002037102d0f id 111d1 installing the sun sparc solaris fusion-mpt? drivers 3-5 if the fc disks on your lsi logic/intraserver adapter are not identi?ed by your system, check the following: 1. are all the fc cables correctly connected to the disk enclosure? 2. is the disk enclosure powered up? 3. if the external disk enclosure required a loopback connector, is the loopback connector correctly installed? 3.1.5 persistent device naming under certain con?gurations, such as when the fc disk is the boot device of a system, it may be preferable to lock a target disk to a unit number. lsi logic/intraserver fcode allows the system administrator to write a nonvolatile map of ids to the fc controller. the following is an example of how to map devices in the persistent device table. select the controller you want to modify, as shown in figure 3.3 : 3-6 software installation figure 3.3 persistent device mapping ok show-disks a) /pci@1f,0/pci@1/intraserver,fc@2/disk b) /pci@1f,0/pci@1/intraserver,ultra2-scsi@1/disk c) /pci@1f,0/pci@1,1/ide@3/cdrom d) /pci@1f,0/pci@1,1/ide@3/disk e) /pci@1f,0/pci@1,1/ebus@1/fdthree@14,3203f0 q) no selection enter selection, q to quit: a /pci@1f,0/pci@1/intraserver,fc@2/disk has been selected. type ^y (control-y) to insert it in the command line. e.g. ok nvalias mydev ^y for creating devalias mydev for /pci@1f,0/pci@1/intraserver,fc@2/disk ok select/pci@1f,0/pci@1/intraserver,fc@2 ok show-children mpt firmware version 1.00 target 0 unit 0 disk seagate st39173fc 6615 wwn 200000203710c4e8 portid a3 ok set-persistent (note: issue command with no parameters to print this help) usage is installing the itmpt sun sparc solaris fc driver 3-7 to clear an entry in the persistent device map, use the clear-persistent command, as shown in figure 3.4 : figure 3.4 clearing an entry entry 1 has been deleted from the table, and the table is now empty. 3.1.6 itmpt device driver the lsi logic/intraserver itmpt driver is designed to sun microsystems scsa speci?cations for device drivers. this driver allows connection of fc devices to lsi logic/intraserver adapter cards on pci-based machines. the following sections describe the procedures to install the driver on solaris. 3.2 installing the itmpt sun sparc solaris fc driver the lsi logic LSI40909G-S uses the itmpt fc driver for solaris. this driver is included with your adapter kit. note: if you plan to use an lsi logic/intraserver fc adapter for your system disk ,you must use the installation procedure as described in section 3.2.2, network installation proce- dure, in order to load the device driver during installation. 3.2.1 existing system installation these instructions provide details to install the lsi logic/intraserver itmpt driver to an existing solaris operating system installation. note: you must be logged on as root to perform the installation. ok 1 clear-persistent entry 1 has been cleared ok show-persistent ok 3-8 software installation 3.2.1.1 floppy disk install if you received the drivers on a ?oppy diskette, follow these steps: step 1. place the diskette in the ?oppy drive and execute the volcheck command to ensure the system sees the ?oppy. step 2. change the directory to the root of the ?oppy (e.g. " cd /floppy/floppy0 "). step 3. execute the pkgadd procedure to add the itmpt driver to the operating system. example: pkgadd ( space ) -d ( space ). you will see the display on the screen as shown in figure 3.5 through figure 3.7 . installing the itmpt sun sparc solaris fc driver 3-9 figure 3.5 pkgadd procedure the following packages are available: 1 timpt lsi logic/intraserver fusionmpt(tm) fibrechannel/scsi drivers (sparc) itmpt kit version 1.1 select package(s) you wish to process (or 'all' to process all packages). (default: all) [?,??,q]: 1 processing package instance 3-10 software installation figure 3.6 completing floppy disk installation see figure 3.8 for additional information. figure 3.7 completing floppy disk installation (continued) to support nonzero luns, which is default for most raid controllers such as the lsi logic metastor ? ,you must edit the ?le /kernel/drv/ssd.conf as shown in figure 3.8 : this package contains scripts which will be executed with superuser permission during the process of installing this package. do you want to continue with the installation of installing the itmpt sun sparc solaris fc driver 3-11 figure 3.8 /kernel/drv/ssd.conf step 4. the itmpt device driver is now installed. reboot the machine to recon?gure the system and to recognize the new devices. 3.2.1.2 distribution file install if you received the drivers in an itmpt_install.tar.z ?le, follow these steps: step 1. uncompress and untar the itmpt_install.tar.z ?le by typing the following commands in order to create a directory named install: uncompress itmpt_install.tar.z tar -xvf itmpt_install.tar cd install step 2. execute the pkgadd process as described in the previous section to add the itmpt driver to the operating system: note: if you change the disk drive con?guration of your machine, it may be necessary to issue the command: touch ( space ) /reconfigure and then reboot the system in order for the system to detect and correctly install your new disks. example: with just the default entry for each target in /kernel/drv/ssd.conf, only devices at lun 0 will be probed. name="ssd" parent="itmpt" target=0; to add nonzero lun support, replace the above entry with an entry for each lun to probe, such as: name="ssd" parent="itmpt" target=0 lun=0; name="ssd" parent="itmpt" target=0 lun=1; name="ssd" parent="itmpt" target=0 lun=2; name="ssd" parent="itmpt" target=0 lun=3; this should be done for any targets that need to probe for multiple luns. 3-12 software installation 3.2.2 network installation procedure if you are using your lsi logic/intraserver adapter to support your sparc solaris system disk, you must install the solaris operating system using a network install. this section describes a complete installation of solaris to a client system using lsi logic/intraserver fc adapters for the system disk. the method described in this section allows you to install the lsi logic/intraserver itmpt driver onto a network boot kit, making it available during the sparc installation process. if you are simply installing an lsi logic/intraserver adapter as an additional storage adapter in an existing system, use the driver installation procedure described in section 3.2.1.2, distribution file install. 3.2.2.1 setting up a boot/install server refer to the preparing to install solaris software over the network, section of the solaris advanced installation guide, available at http://docs .sun.com . the basic steps to set up a boot and install server are as follows: step 1. insert your solaris distribution cd in your boot/install servers cd-rom drive. step 2. change your directory to the tools area on your distribution cd: cd /cdrom/cdrom0/solaris_2.7/tools step 3. use the setup_install_server script to copy the boot and installation ?les to your boot/install server: ./setup_install_server /export/home/install 3.2.2.2 installing the itmpt driver on the boot/install server after you have set up your network boot and install server, follow these steps run the install.sh script with the C n parameter to copy the driver kit to the boot servers boot ?les: step 1. place the diskette in the ?oppy drive and execute the volcheck command to ensure the system sees the ?oppy. step 2. change the directory to the root of the ?oppy: installing the itmpt sun sparc solaris fc driver 3-13 cd /floppy/floppy0 step 3. execute the install.sh shell script to add the itmpt driver to the boot installation area: ./install.sh Cn /export/home/install/solaris_2.7 notes: for solaris 2.8 boot ?les, the directory would be /export/home/install/solaris_2.8. the message major number maximum based on server, not client can safely be ignored. running the install.sh script this way copies and installs the lsi logic/intraserver drivers into the tools/boot/ area of the boot ?les and allows lsi logic/intraserver adapters to be booted for installation using the bootserver. 3.2.2.3 adding clients to your boot/install server for each machine that boots into the boot/install server, follow these steps to add a client entry on the boot/install server: step 1. change the directory to the boot/install kit: cd /export/home/install/solaris_2.7/tools step 2. use the add_install_client script to add the client machine ./add_install_client -i ipaddr -e ethernetid client_name platform_group where: example: ./add_install_client -i 192.168.103.124 Ce 00:08:26:02:25:34 sunsys sun4u ipaddr is the tcp/ip address of the client ethernetid is the ethernet hardware (mac) address of the client client_name is the clients system name platform_group is the clients vendor de?ned hardware group 3-14 software installation note: you can obtain the platform_group from a machine of the same type as the target client using the uname Cm command . 3.2.2.4 booting the client using the itmpt fc driver now you can begin the installation of the solaris operating system to the client target machine using the boot and install server. on the client machine, boot the network install kit you created in the preceding steps as follows: ok boot net -v note: it is important to choose "manual reboot" rather than "auto reboot" during the installation of solaris on the target machine. if you choose "auto reboot", you will not have the opportunity to complete the installation of the lsi logic/intraserver fc drivers and your system will fail to boot. after the installation has completed and the system is waiting to be manually rebooted, proceed to a console window and run the following script: /sbin/itmptinst this copies and installs the drivers from the boot server to the newly created solaris installation. after this script has been run, the lsi logic/intraserver device driver installation is complete and the system can be rebooted. troubleshooting 3-15 notes: the message major number maximum based on server, not client can safely be ignored. your sun machine will prompt you to allow power saving automatic shutdown. you must answer no to this question if you are using the lsi logic/intraserver adapter to support your boot disk. if you change the disk drive con?guration of your machine, it may be necessary to issue the command: touch /reconfigure and then reboot the system in order for the system to detect and correctly install your new disks. 3.3 troubleshooting table 3.2 lists some potential error messages that may be preceded by a warning message displayed by the operating system. in the message descriptions below the itmpt 3-16 software installation itmpt troubleshooting 3-17 itmpt 3-18 software installation LSI40909G-S pci to fibre channel host adapter for sun solaris 4-1 chapter 4 LSI40909G-S technical characteristics this chapter provides speci?c details about the physical environment associated with the LSI40909G-S. this chapter includes these topics: section 4.1, physical environment, page 4-1 section 4.2, operational environment, page 4-3 section 4.3, ieee unique address, page 4-4 4.1 physical environment this section provides information about the physical, electrical, thermal, and safety characteristics of the LSI40909G-S. additionally, these boards are compliant with electromagnetic standards set by the fcc. 4.1.1 physical characteristics the LSI40909G-S is a pci short card; the dimensions are 168 x 98 mm (6.625 x 3.875 inches). j1 is the pci edge connector. the external fc connection is made through a 1 gigabit/s gbic optical module. the component height on the top and bottom of the board conforms to the pci local bus speci?cation, revision 2.2. figure 4.1 illustrates the components on the LSI40909G-S. 4-2 LSI40909G-S technical characteristics figure 4.1 LSI40909G-S components 4.1.2 electrical characteristics under normal conditions, the LSI40909G-S maximum power requirement is:+5vdc, 5%, 1.0 a, and over the operating range 0 cto55 c. under abnormal conditions + 5 v current may be higher. the pci prsnt1/ and prsnt2/ pins are set to indicate a 7.5 w maximum con?guration. 4.1.3 thermal, atmospheric characteristics the thermal, atmospheric characteristics of the LSI40909G-S are: temperature range: 0 cto55 c (dry bulb) relative humidity range: 5% to 90% noncondensing maximum dew point temperature: 32 c j1_t c 2000 lsi logic all rights reserved u5 u6 u8 u9 u1 vr2 u7 cr3 u10 j1 product name assembly numbers/rev 0001234567 123456 gbic lsifc909 sram sram sram sram flash operational environment 4-3 the following parameters de?ne the storage and transit environment for the LSI40909G-S: storage temperature: - 45 cto+85 c (dry bulb) relative humidity range: 5% to 95% noncondensing 4.1.4 electromagnetic compliance these boards minimize electromagnetic emissions, susceptibility, and the effects of electromagnetic discharge. the boards comply with class b and carry markings for ce, vcci, canada, c-tick, and fcc. 4.1.5 safety characteristics the bare boards meet or exceed the requirements of ul ?ammability rating 94 v0. the bare boards are also marked with the suppliers name or trademark, type, and ul ?ammability rating. because these boards are installed in a pci bus slot, all voltages are below the selv 42.4 v limit. 4.2 operational environment use the LSI40909G-S in pci computer systems with an isa/eisa bracket type. the lsi logic supplied fc bios and ?rmware operate the boards. an on-board ?ash memory device and a serial eeprom are provided to allow bios code and open boot code support through pci. 4.2.1 the pci interface the pci interface operates as a 64-bit dma bus master. edge connector j1 makes the pci connection, which provides connections on both the front and back of the board. the signal de?nitions and pin numbers conform to the pci local bus speci?cation, revision 2.2. see that speci?cation for more details regarding the signal assignments. the on-board regulators provide power to the boards 3.3 v devices. note: the pci + 3.3 v pins are tied together and decoupled with high frequency bypass capacitors to ground. no current from these + 3.3 v pins is used on the board. the board derives power from the + 5 v pins, directly and through a 4-4 LSI40909G-S technical characteristics 3.3 v voltage regulator. the pci + 3 v/ + 5 v pins are used to differentiate between a 5 v or a 3.3 v pci signaling environment. 4.2.2 the fc interface the LSI40909G-S fibre channel interface provides an optical connection to the fc link. the gbic board uses an sca connector and rail set which accepts a gbic module. 4.2.3 the fc link activity/link fault led the LSI40909G-S provides a dual-purpose led visible through the bracket which indicates activity on the fc link when the led is green. this led turns yellow when there has been a fault on the fc link. 4.3 ieee unique address each LSI40909G-S is provided with a unique ieee address. the last six hexadecimal characters of this address appear on a label on the board. this address is stored in the serial eeprom on the board, and is also used for the worldwide name. LSI40909G-S pci to fibre channel host adapter for sun solaris a-1 3.75 pc 10.25 pc 11.25 pc 38.25 pc 4.333 pc 12 pc 12.938 pc 13.851 pc 48.583 pc 52.5 pc 34.5 pc 34.732 pc appendix a glossary of terms and abbreviations 8b/10b a data encoding scheme developed by ibm, translating byte wide data to an encoded 10-bit format. ansi american national standards institute. the coordinating organization for voluntary standards in the united states. arbitrated loop topology (fc-al) a fc topology that provides a low cost solution to attach multiple ports in a loop without hubs and switches. ber bit error rate. bit a binary digit. the smallest unit of information a computer uses. the value of a bit (0 or 1) represents a two-way choice, such as on or off, true or false, and so on. broadcast sending a transmission to all n_ports on a fabric. bus a collection of unbroken signal lines across which information is transmitted from one part of a computer system to another. connections to the bus are made using taps on the lines. bus mastering a high-performance way to transfer data. the host adapter controls the transfer of data directly to and from system memory without bothering the computers microprocessor. this is the fastest way for multitasking operating systems to transfer data. byte a unit of information consisting of eight bits. channel a point-to-point link, the main task of which is to transport data from one point to another. 3.75 pc 10.25 pc 11.25 pc 38.25 pc 4.333 pc 48.583 pc 52.5 pc 34.5 pc 44.25 pc a-2 glossary of terms and abbreviations con?guration refers to the way a computer is setup; the combined hardware components (computer, monitor, keyboard, and peripheral devices) that make up a computer system; or the software settings that allow the hardware components to communicate with each other. cpu central processing unit. the brain of the computer that performs the actual computations. the term microprocessor unit (mpu) is also used. crosspoint- switched topology (fc-xs) highest performance fc fabric, providing a choice of multiple path routings between pairs of f_ports. dma direct memory access. a method of moving data from a storage device directly to ram, without using the cpus resources. dma bus master a feature that allows a peripheral to control the ?ow of data to and from system memory by blocks, as opposed to pio (programmed i/o) where the processor is in control and the ?ow is by byte. device driver a program that allows a microprocessor (through the operating system) to direct the operation of a peripheral device. eeprom electronically erasable programmable read only memory. a memory chip typically used to store con?guration information. eisa extended industry standard architecture. an extension of the 16-bit isa bus standard. it allows devices to perform 32-bit data transfers. exchange a term that refers to one of the fc building blocks, composed of one or more nonconcurrent sequences for a single operation. fabric fc de?ned interconnection methodology that handles routing in fc networks. fc-ep the future fc enhanced physical standard, which will build on and is compatible with fc-ph. fc-ph fc physical standard, consisting of the three lower levels; fc-0, fc-1, and fc-2. fc-0 lowest level of the fc physical standard, covering the physical characteristics of the interface and media. 3.75 pc 10.25 pc 11.25 pc 38.25 pc 4.333 pc 48.583 pc 52.5 pc 34.5 pc 44.25 pc glossary of terms and abbreviations a-3 fc-1 middle level of the fc-ph standard, de?ning the 8b/10b encoding/decoding and transmission protocol. fc-2 highest level of fc-ph, de?ning the rules for signaling protocol and describing transfer of the frame, sequence, and exchanges. fc-3 the hierarchical level in the fc standard that provides common services, such as striping de?nition. fc-4 the hierarchical level in the fc standard that speci?es the mapping of upper layer protocols (ulps) to levels below. fcc federal communications commission. fcp fibre channel protocol. fddi fiber distributed data interface. ansi option for a metropolitan area network (man); a network based on the use of optical ?ber cable to transmit data at 100 mbits/s. fibre channel service protocol (fsp) the common fc-4 level protocol for all services, transparent to the fabric type or topology. file a named collection of information stored on a disk. firmware software that is permanently stored in rom. therefore, it can be accessed during boot time. f_port fabric port, the access point of the fabric for physically connecting the users n_port. fl_port an f_port that contains arbitrated loop functions. frame a linear set of transmitted bits that de?ne a basic transport element. hard disk a disk made of metal and permanently sealed into a drive cartridge. a hard disk can store very large amounts of information. hal hardware abstraction layer. hippi high performance parallel interface. an 800 mbits/s interface to supercomputer networks (formerly known as high speed channel) developed by ansi. 3.75 pc 10.25 pc 11.25 pc 38.25 pc 4.333 pc 48.583 pc 52.5 pc 34.5 pc 44.25 pc a-4 glossary of terms and abbreviations host the computer system in which a scsi host adapter is installed. it uses the scsi host adapter to transfer information to and from devices attached to the scsi bus. host adapter a circuit board or integrated circuit that provides a scsi bus connection to the computer system. ip internet protocol. ipi intelligent peripheral interface. isa industry standard architecture. a type of computer bus used in most pcs. it allows devices to send and receive data up to 16 bits at a time. kbyte kilobyte. a measure of computer storage equal to 1024 bytes. lct logical con?guration table. llc logical link control. local bus a way to connect peripherals directly to computer memory. it bypasses the slower isa and eisa buses. pci is a local bus standard. l_port an fc port which supports the arbitrated loop topology. link_control_ facility a termination card that handles the logical and physical control of the fc link for each mode of use. login server entity within the fc fabric that receives and responds to login requests. lun logical unit number. an identi?er, zero to seven, for a logical unit. mbyte megabyte. a measure of computer storage equal to 1024 kilobytes. mfa message frame address. multicast refers to delivering a single transmission to multiple destination n_ports. nic network interface card. n_port node port, an fc de?ned hardware entity at the node end of a link. nl_port an n_port that contains arbitrated loop functions. 3.75 pc 10.25 pc 11.25 pc 38.25 pc 4.333 pc 48.583 pc 52.5 pc 34.5 pc 44.25 pc glossary of terms and abbreviations a-5 operating system a program that organizes the internal activities of the computer and its peripheral devices. an operating system performs basic tasks such as moving data to and from devices, and managing information in memory. it also provides the user interface. operation a term, de?ned in fc-2, that refers to one of the fc building blocks composed of one or more, possibly concurrent, exchanges. ordered set an fc term referring to four 10-bit characters (a combination of data and special characters) that provide low level link functions, such as frame demarcation and signaling between two ends of a link. it provides for initialization of the link after power-on and for some basic recovery actions. originator an fc term referring to the initiating device. parity checking a way to verify the accuracy of data transmitted over the scsi bus. one bit in the transfer is used to make the sum of all the 1 bits either odd or even (for odd or even parity). if the sum is not correct, an error message appears. pci peripheral component interconnect. a local bus speci?cation that allows connection of peripherals directly to computer memory. it bypasses the slower isa and eisa buses. pdb packet descriptor block. pio programmed input/output. a way the cpu can transfer data to and from memory using the computers i/o ports. pio is usually faster than dma, but requires cpu time. port the hardware entity within a node that performs data communications over the fc link. port address also port number. the address through which commands are sent to a host adapter board. this address is assigned by the pci bus. port number see port address. ram random access memory. the computers primary working memory in which program instructions and data are stored and are accessible to the cpu. information can be written to and read from ram. the contents of ram are lost when the computer is turned off. 3.75 pc 10.25 pc 11.25 pc 38.25 pc 4.333 pc 48.583 pc 52.5 pc 34.5 pc 44.25 pc a-6 glossary of terms and abbreviations responder an fc term referring to the answering device. risc core lsifc909 chips contain a risc (reduced instruction set computer) processor, programmed through microcode scripts. rom read only memory. memory from which information can be read but not changed. the contents of rom are not erased when the computer is turned off. san storage area network. scam scsi con?gured automatically. a method to automatically allocate scsi ids using software when scam compliant scsi devices are attached. scatter/gather a device driver feature that lets the host adapter modify a transfer data pointer so that a single host adapter transfer can access many segments of memory. this minimizes interrupts and transfer overhead. scb scsi command block. scsi small computer system interface. a speci?cation for a high-performance peripheral bus and command set. the original standard is referred to as scsi-1. scsi-2 the current scsi speci?cation which adds features to the original scsi-1 standard. scsi id a way to uniquely identify each scsi device on the scsi bus. each scsi bus has eight available scsi ids numbered 0 through 7 (or 0 through 15 for wide scsi). the host adapter usually gets id 7 giving it priority to control the bus. sequence a term referring to one of the fc building blocks, composed of one or more related frames for a single operation. sgl scatter gather list. snap subnetwork access protocol. synchronous data transfer one of the ways data is transferred over the scsi bus. transfers are clocked with ?xed frequency pulses. this is faster than asynchronous data transfer. synchronous data transfers are negotiated between the scsi host adapter and each scsi device. 3.75 pc 10.25 pc 11.25 pc 38.25 pc 4.333 pc 48.583 pc 52.5 pc 34.5 pc 44.25 pc glossary of terms and abbreviations a-7 system bios controls the low level post (power-on self-test), and basic operation of the cpu and computer system. tid target id. topology the logical and/or physical arrangement of stations on a network. ulp upper layer protocol. vcci voluntary control council for interference. virtual memory space on a hard disk that can be used as if it were ram. vpd vendor product data. word a two byte (or 16 bit) unit of information. x3t9 a technical committee of the accredited standards committee x3, titled x3t9 i/o interfaces. it is tasked with developing standards for moving data in and out of central computers. 3.75 pc 10.25 pc 11.25 pc 38.25 pc 4.333 pc 48.583 pc 52.5 pc 34.5 pc 44.25 pc a-8 glossary of terms and abbreviations LSI40909G-S pci to fibre channel host adapter for sun solaris customer feedback we would appreciate your feedback on this document. please copy the following page, add your comments, and fax it to us at the number shown. if appropriate, please also fax copies of any marked-up pages from this document. impor tant: please include your name, phone number, fax number, and company address so that we may contact you directly for clari?cation or additional information. thank you for your help in improving the quality of our documents. customer feedback readers comments fax your comments to: lsi logic corporation technical publications m/s e-198 fax: 408.433.4333 please tell us how you rate this document: LSI40909G-S pci to fibre channel host adapter for sun solaris users guide. place a check mark in the appropriate blank for each category. what could we do to improve this document? if you found errors in this document, please specify the error and page number. if appropriate, please fax a marked-up copy of the page(s). please complete the information below so that we may contact you directly for clari?cation or additional information. excellent good average fair poor completeness of information ____ ____ ____ ____ ____ clarity of information ____ ____ ____ ____ ____ ease of ?nding information ____ ____ ____ ____ ____ technical content ____ ____ ____ ____ ____ usefulness of examples and illustrations ____ ____ ____ ____ ____ overall manual ____ ____ ____ ____ ____ name date telephone title company name street city, state, zip department mail stop fax u.s. distributors by state a. e. avnet electronics http://www.hh.avnet.com b. m. bell microproducts, inc. (for habs) http://www.bellmicro.com i. e. insight electronics http://www.insight-electronics.com w. e. wyle electronics http://www.wyle.com alabama daphne i. e. tel: 334.626.6190 huntsville a. e. tel: 256.837.8700 b. m. tel: 256.705.3559 i. e. tel: 256.830.1222 w. e. tel: 800.964.9953 alaska a. e. tel: 800.332.8638 arizona phoenix a. e. tel: 480.736.7000 b. m. tel: 602.267.9551 w. e. tel: 800.528.4040 tempe i. e. tel: 480.829.1800 tucson a. e. tel: 520.742.0515 arkansas w. e. tel: 972.235.9953 california agoura hills b. m. tel: 818.865.0266 granite bay b. m. tel: 916.523.7047 irvine a. e. tel: 949.789.4100 b. m. tel: 949.470.2900 i. e. tel: 949.727.3291 w. e. tel: 800.626.9953 los angeles a. e. tel: 818.594.0404 w. e. tel: 800.288.9953 sacramento a. e. tel: 916.632.4500 w. e. tel: 800.627.9953 san diego a. e. tel: 858.385.7500 b. m. tel: 858.597.3010 i. e. tel: 800.677.6011 w. e. tel: 800.829.9953 san jose a. e. tel: 408.435.3500 b. m. tel: 408.436.0881 i. e. tel: 408.952.7000 santa clara w. e. tel: 800.866.9953 woodland hills a. e. tel: 818.594.0404 westlake village i. e. tel: 818.707.2101 colorado denver a. e. tel: 303.790.1662 b. m. tel: 303.846.3065 w. e. tel: 800.933.9953 englewood i. e. tel: 303.649.1800 idaho springs b. m. tel: 303.567.0703 connecticut cheshire a. e. tel: 203.271.5700 i. e. tel: 203.272.5843 wallingford w. e. tel: 800.605.9953 delaware north/south a. e. tel: 800.526.4812 tel: 800.638.5988 b. m. tel: 302.328.8968 w. e. tel: 856.439.9110 florida altamonte springs b. m. tel: 407.682.1199 i. e. tel: 407.834.6310 boca raton i. e. tel: 561.997.2540 bonita springs b. m. tel: 941.498.6011 clearwater i. e. tel: 727.524.8850 fort lauderdale a. e. tel: 954.484.5482 w. e. tel: 800.568.9953 miami b. m. tel: 305.477.6406 orlando a. e. tel: 407.657.3300 w. e. tel: 407.740.7450 tampa w. e. tel: 800.395.9953 st. petersburg a. e. tel: 727.507.5000 georgia atlanta a. e. tel: 770.623.4400 b. m. tel: 770.980.4922 w. e. tel: 800.876.9953 duluth i. e. tel: 678.584.0812 hawaii a. e. tel: 800.851.2282 idaho a. e. tel: 801.365.3800 w. e. tel: 801.974.9953 illinois north/south a. e. tel: 847.797.7300 tel: 314.291.5350 chicago b. m. tel: 847.413.8530 w. e. tel: 800.853.9953 schaumburg i. e. tel: 847.885.9700 indiana fort wayne i. e. tel: 219.436.4250 w. e. tel: 888.358.9953 indianapolis a. e. tel: 317.575.3500 iowa w. e. tel: 612.853.2280 cedar rapids a. e. tel: 319.393.0033 kansas w. e. tel: 303.457.9953 kansas city a. e. tel: 913.663.7900 lenexa i. e. tel: 913.492.0408 kentucky w. e. tel: 937.436.9953 central/northern/ western a. e. tel: 800.984.9503 tel: 800.767.0329 tel: 800.829.0146 louisiana w. e. tel: 713.854.9953 north/south a. e. tel: 800.231.0253 tel: 800.231.5775 maine a. e. tel: 800.272.9255 w. e. tel: 781.271.9953 maryland baltimore a. e. tel: 410.720.3400 w. e. tel: 800.863.9953 columbia b. m. tel: 800.673.7461 i. e. tel: 410.381.3131 massachusetts boston a. e. tel: 978.532.9808 w. e. tel: 800.444.9953 burlington i. e. tel: 781.270.9400 marlborough b. m. tel: 800.673.7459 woburn b. m. tel: 800.552.4305 michigan brighton i. e. tel: 810.229.7710 detroit a. e. tel: 734.416.5800 w. e. tel: 888.318.9953 clarkston b. m. tel: 877.922.9363 minnesota champlin b. m. tel: 800.557.2566 eden prairie b. m. tel: 800.255.1469 minneapolis a. e. tel: 612.346.3000 w. e. tel: 800.860.9953 st. louis park i. e. tel: 612.525.9999 mississippi a. e. tel: 800.633.2918 w. e. tel: 256.830.1119 missouri w. e. tel: 630.620.0969 st. louis a. e. tel: 314.291.5350 i. e. tel: 314.872.2182 u.s. distributors by state (continued) montana a. e. tel: 800.526.1741 w. e. tel: 801.974.9953 nebraska a. e. tel: 800.332.4375 w. e. tel: 303.457.9953 nevada las vegas a. e. tel: 800.528.8471 w. e. tel: 702.765.7117 new hampshire a. e. tel: 800.272.9255 w. e. tel: 781.271.9953 new jersey north/south a. e. tel: 201.515.1641 tel: 609.222.6400 mt. laurel i. e. tel: 856.222.9566 pine brook b. m. tel: 973.244.9668 w. e. tel: 800.862.9953 parsippany i. e. tel: 973.299.4425 wayne w. e. tel: 973.237.9010 new mexico w. e. tel: 480.804.7000 albuquerque a. e. tel: 505.293.5119 new york hauppauge i. e. tel: 516.761.0960 long island a. e. tel: 516.434.7400 w. e. tel: 800.861.9953 rochester a. e. tel: 716.475.9130 i. e. tel: 716.242.7790 w. e. tel: 800.319.9953 smithtown b. m. tel: 800.543.2008 syracuse a. e. tel: 315.449.4927 north carolina raleigh a. e. tel: 919.859.9159 i. e. tel: 919.873.9922 w. e. tel: 800.560.9953 north dakota a. e. tel: 800.829.0116 w. e. tel: 612.853.2280 ohio cleveland a. e. tel: 216.498.1100 w. e. tel: 800.763.9953 dayton a. e. tel: 614.888.3313 i. e. tel: 937.253.7501 w. e. tel: 800.575.9953 strongsville b. m. tel: 440.238.0404 valley view i. e. tel: 216.520.4333 oklahoma w. e. tel: 972.235.9953 tulsa a. e. tel: 918.459.6000 i. e. tel: 918.665.4664 oregon beaverton b. m. tel: 503.524.1075 i. e. tel: 503.644.3300 portland a. e. tel: 503.526.6200 w. e. tel: 800.879.9953 pennsylvania mercer i. e. tel: 412.662.2707 philadelphia a. e. tel: 800.526.4812 b. m. tel: 877.351.2355 w. e. tel: 800.871.9953 pittsburgh a. e. tel: 412.281.4150 w. e. tel: 440.248.9996 rhode island a. e. 800.272.9255 w. e. tel: 781.271.9953 south carolina a. e. tel: 919.872.0712 w. e. tel: 919.469.1502 south dakota a. e. tel: 800.829.0116 w. e. tel: 612.853.2280 tennessee w. e. tel: 256.830.1119 east/west a. e. tel: 800.241.8182 tel: 800.633.2918 texas arlington b. m. tel: 817.417.5993 austin a. e. tel: 512.219.3700 b. m. tel: 512.258.0725 i. e. tel: 512.719.3090 w. e. tel: 800.365.9953 dallas a. e. tel: 214.553.4300 b. m. tel: 972.783.4191 w. e. tel: 800.955.9953 el paso a. e. tel: 800.526.9238 houston a. e. tel: 713.781.6100 b. m. tel: 713.917.0663 w. e. tel: 800.888.9953 richardson i. e. tel: 972.783.0800 rio grande valley a. e. tel: 210.412.2047 stafford i. e. tel: 281.277.8200 utah centerville b. m. tel: 801.295.3900 murray i. e. tel: 801.288.9001 salt lake city a. e. tel: 801.365.3800 w. e. tel: 800.477.9953 vermont a. e. tel: 800.272.9255 w. e. tel: 716.334.5970 virginia a. e. tel: 800.638.5988 w. e. tel: 301.604.8488 haymarket b. m. tel: 703.754.3399 spring?eld b. m. tel: 703.644.9045 washington kirkland i. e. tel: 425.820.8100 maple valley b. m. tel: 206.223.0080 seattle a. e. tel: 425.882.7000 w. e. tel: 800.248.9953 west virginia a. e. tel: 800.638.5988 wisconsin milwaukee a. e. tel: 414.513.1500 w. e. tel: 800.867.9953 wauwatosa i. e. tel: 414.258.5338 wyoming a. e. tel: 800.332.9326 w. e. tel: 801.974.9953 direct sales representatives by state (components and boards) e. a. earle associates e. l. electrodyne - ut grp group 2000 i. s. in?nity sales, inc. ion ion associates, inc. r. a. rathsburg associ- ates, inc. sgy synergy associates, inc. arizona tempe e. a. tel: 480.921.3305 california calabasas i. s. tel: 818.880.6480 irvine i. s. tel: 714.833.0300 san diego e. a. tel: 619.278.5441 illinois elmhurst r. a. tel: 630.516.8400 indiana cicero r. a. tel: 317.984.8608 ligonier r. a. tel: 219.894.3184 plain?eld r. a. tel: 317.838.0360 massachusetts burlington sgy tel: 781.238.0870 michigan byron center r. a. tel: 616.554.1460 good rich r. a. tel: 810.636.6060 novi r. a. tel: 810.615.4000 north carolina cary grp tel: 919.481.1530 ohio columbus r. a. tel: 614.457.2242 dayton r. a. tel: 513.291.4001 independence r. a. tel: 216.447.8825 pennsylvania somerset r. a. tel: 814.445.6976 texas austin ion tel: 512.794.9006 arlington ion tel: 817.695.8000 houston ion tel: 281.376.2000 utah salt lake city e. l. tel: 801.264.8050 wisconsin muskego r. a. tel: 414.679.8250 saukville r. a. tel: 414.268.1152 sales of?ces and design resource centers lsi logic corporation corporate headquarters 1551 mccarthy blvd milpitas ca 95035 tel: 408.433.8000 fax: 408.433.8989 north america california irvine 18301 von karman ave suite 900 irvine, ca 92612 tel: 949.809.4600 fax: 949.809.4444 pleasanton design center 5050 hopyard road, 3rd floor suite 300 pleasanton, ca 94588 tel: 925.730.8800 fax: 925.730.8700 san diego 7585 ronson road suite 100 san diego, ca 92111 tel: 858.467.6981 fax: 858.496.0548 silicon valley 1551 mccarthy blvd sales of?ce m/s c-500 milpitas, ca 95035 tel: 408.433.8000 fax: 408.954.3353 design center m/s c-410 tel: 408.433.8000 fax: 408.433.7695 wireless design center 11452 el camino real suite 210 san diego, ca 92130 tel: 858.350.5560 fax: 858.350.0171 colorado boulder 4940 pearl east circle suite 201 boulder, co 80301 tel: 303.447.3800 fax: 303.541.0641 colorado springs 4420 arrowswest drive colorado springs, co 80907 tel: 719.533.7000 fax: 719.533.7020 fort collins 2001 dan?eld court fort collins, co 80525 tel: 970.223.5100 fax: 970.206.5549 florida boca raton 2255 glades road suite 324a boca raton, fl 33431 tel: 561.989.3236 fax: 561.989.3237 georgia alpharetta 2475 north winds parkway suite 200 alpharetta, ga 30004 tel: 770.753.6146 fax: 770.753.6147 illinois oakbrook terrace two mid american plaza suite 800 oakbrook terrace, il 60181 tel: 630.954.2234 fax: 630.954.2235 kentucky bowling green 1262 chestnut street bowling green, ky 42101 tel: 270.793.0010 fax: 270.793.0040 maryland bethesda 6903 rockledge drive suite 230 bethesda, md 20817 tel: 301.897.5800 fax: 301.897.8389 massachusetts waltham 200 west street waltham, ma 02451 tel: 781.890.0180 fax: 781.890.6158 burlington - mint technology 77 south bedford street burlington, ma 01803 tel: 781.685.3800 fax: 781.685.3801 minnesota minneapolis 8300 norman center drive suite 730 minneapolis, mn 55437 tel: 612.921.8300 fax: 612.921.8399 new jersey red bank 125 half mile road suite 200 red bank, nj 07701 tel: 732.933.2656 fax: 732.933.2643 cherry hill - mint technology 215 longstone drive cherry hill, nj 08003 tel: 856.489.5530 fax: 856.489.5531 new york fairport 550 willowbrook of?ce park fairport, ny 14450 tel: 716.218.0020 fax: 716.218.9010 north carolina raleigh phase ii 4601 six forks road suite 528 raleigh, nc 27609 tel: 919.785.4520 fax: 919.783.8909 oregon beaverton 15455 nw greenbrier parkway suite 235 beaverton, or 97006 tel: 503.645.0589 fax: 503.645.6612 texas austin 9020 capital of tx highway north building 1 suite 150 austin, tx 78759 tel: 512.388.7294 fax: 512.388.4171 plano 500 north central expressway suite 440 plano, tx 75074 tel: 972.244.5000 fax: 972.244.5001 houston 20405 state highway 249 suite 450 houston, tx 77070 tel: 281.379.7800 fax: 281.379.7818 canada ontario ottawa 260 hearst way suite 400 kanata, on k2l 3h1 tel: 613.592.1263 fax: 613.592.3253 international france paris lsi logic s.a. immeuble europa 53 bis avenue de l'europe b.p. 139 78148 velizy-villacoublay cedex, paris tel: 33.1.34.63.13.13 fax: 33.1.34.63.13.19 germany munich lsi logic gmbh orleansstrasse 4 81669 munich tel: 49.89.4.58.33.0 fax: 49.89.4.58.33.108 stuttgart mittlerer pfad 4 d-70499 stuttgart tel: 49.711.13.96.90 fax: 49.711.86.61.428 italy milan lsi logic s.p.a. centro direzionale colleoni palazzo orione ingresso 1 20041 agrate brianza, milano tel: 39.039.687371 fax: 39.039.6057867 japan tokyo lsi logic k.k. rivage-shinagawa bldg. 14f 4-1-8 kounan minato-ku, tokyo 108-0075 tel: 81.3.5463.7821 fax: 81.3.5463.7820 osaka crystal tower 14f 1-2-27 shiromi chuo-ku, osaka 540-6014 tel: 81.6.947.5281 fax: 81.6.947.5287 sales of?ces and design resource centers (continued) korea seoul lsi logic corporation of korea ltd 10th fl., haesung 1 bldg. 942, daechi-dong, kangnam-ku, seoul, 135-283 tel: 82.2.528.3400 fax: 82.2.528.2250 the netherlands eindhoven lsi logic europe ltd world trade center eindhoven building rijder bogert 26 5612 lz eindhoven tel: 31.40.265.3580 fax: 31.40.296.2109 singapore singapore lsi logic pte ltd 7 temasek boulevard #28-02 suntec tower one singapore 038987 tel: 65.334.9061 fax: 65.334.4749 sweden stockholm lsi logic ab finlandsgatan 14 164 74 kista tel: 46.8.444.15.00 fax: 46.8.750.66.47 taiwan taipei lsi logic asia, inc. taiwan branch 10/f 156 min sheng e. road section 3 taipei, taiwan r.o.c. tel: 886.2.2718.7828 fax: 886.2.2718.8869 united kingdom bracknell lsi logic europe ltd greenwood house london road bracknell, berkshire rg12 2ub tel: 44.1344.426544 fax: 44.1344.481039 sales of?ces with design resource centers international distributors australia new south wales reptechnic pty ltd 3/36 bydown street neutral bay, nsw 2089 tel: 612.9953.9844 fax: 612.9953.9683 belgium acal nv/sa lozenberg 4 1932 zaventem tel: 32.2.7205983 fax: 32.2.7251014 china beijing lsi logic international services inc. beijing representative of?ce room 708 canway building 66 nan li shi lu xicheng district beijing 100045, china tel: 86.10.6804.2534 to 38 fax: 86.10.6804.2521 france rungis cedex azzurri technology france 22 rue saarinen sillic 274 94578 rungis cedex tel: 33.1.41806310 fax: 33.1.41730340 germany haar ebv elektronik hans-pinsel str. 4 d-85540 haar tel: 49.89.4600980 fax: 49.89.46009840 munich avnet emg gmbh stahlgruberring 12 81829 munich tel: 49.89.45110102 fax: 49.89.42.27.75 wuennenberg-haaren peacock ag graf-zepplin-str 14 d-33181 wuennenberg-haaren tel: 49.2957.79.1692 fax: 49.2957.79.9341 hong kong hong kong avt industrial ltd unit 608 tower 1 cheung sha wan plaza 833 cheung sha wan road kowloon, hong kong tel: 852.2428.0008 fax: 852.2401.2105 serial system (hk) ltd 2301 nanyang plaza 57 hung to road, kwun tong kowloon, hong kong tel: 852.2995.7538 fax: 852.2950.0386 india bangalore spike technologies india private ltd 951, vijayalakshmi complex, 2nd floor, 24th main, j p nagar ii phase, bangalore, india 560078 tel: 91.80.664.5530 fax: 91.80.664.9748 israel tel aviv eastronics ltd 11 rozanis street p.o. box 39300 tel aviv 61392 tel: 972.3.6458777 fax: 972.3.6458666 japan tokyo daito electron sogo kojimachi no.3 bldg 1-6 kojimachi chiyoda-ku, tokyo 102-8730 tel: 81.3.3264.0326 fax: 81.3.3261.3984 global electronics corporation nichibei time24 bldg. 35 tansu-cho shinjuku-ku, tokyo 162-0833 tel: 81.3.3260.1411 fax: 81.3.3260.7100 technical center tel: 81.471.43.8200 marubeni solutions 1-26-20 higashi shibuya-ku, tokyo 150-0001 tel: 81.3.5778.8662 fax: 81.3.5778.8669 shinki electronics myuru daikanyama 3f 3-7-3 ebisu minami shibuya-ku, tokyo 150-0022 tel: 81.3.3760.3110 fax: 81.3.3760.3101 yokohama-city innotech 2-15-10 shin yokohama kohoku-ku yokohama-city, 222-8580 tel: 81.45.474.9037 fax: 81.45.474.9065 macnica corporation hakusan high-tech park 1-22-2 hadusan, midori-ku, yokohama-city, 226-8505 tel: 81.45.939.6140 fax: 81.45.939.6141 the netherlands eindhoven acal nederland b.v. beatrix de rijkweg 8 5657 eg eindhoven tel: 31.40.2.502602 fax: 31.40.2.510255 switzerland brugg lsi logic sulzer ag mattenstrasse 6a ch 2555 brugg tel: 41.32.3743232 fax: 41.32.3743233 taiwan taipei avnet-mercuries corporation, ltd 14f, no. 145, sec. 2, chien kuo n. road taipei, taiwan, r.o.c. tel: 886.2.2516.7303 fax: 886.2.2505.7391 lumax international corporation, ltd 7th fl., 52, sec. 3 nan-kang road taipei, taiwan, r.o.c. tel: 886.2.2788.3656 fax: 886.2.2788.3568 prospect technology corporation, ltd 4fl., no. 34, chu luen street taipei, taiwan, r.o.c. tel: 886.2.2721.9533 fax: 886.2.2773.3756 wintech microeletronics co., ltd 7f., no. 34, sec. 3, pateh road taipei, taiwan, r.o.c. tel: 886.2.2579.5858 fax: 886.2.2570.3123 united kingdom maidenhead azzurri technology ltd 16 grove park business estate waltham road white waltham maidenhead, berkshire sl6 3lw tel: 44.1628.826826 fax: 44.1628.829730 milton keynes ingram micro (uk) ltd garamonde drive wymbush milton keynes buckinghamshire mk8 8df tel: 44.1908.260422 swindon ebv elektronik 12 interface business park bincknoll lane wootton bassett, swindon, wiltshire sn4 8sy tel: 44.1793.849933 fax: 44.1793.859555 sales of?ces with design resource centers |
Price & Availability of LSI40909G-S
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |