ausgabedatum26.03.2001 subject to reasonable modifications due to technical advances. copyright pepperl+fuchs, printed in germany pepperl+fuchs group ? tel.: germany (06 21) 7 76-0 usa (330) 4 25 35 55 singapore 7 79 90 91 internet http://www.pepperl- fuchs.com 1 technische daten technical data features electrical connection dimensions general specifications sensing range 100 ... 2000 mm standard target plate 100 mm x 100 mm unusable area 100 mm transducer frequency approx. 175 khz response delay minimum (em; none): 50 ms (2 measuring cycles) factory setting (em, mxn, 5, 2): 150 ms (6 measuring cycles) dynamic (em, dyn): 75 ms (3 measuring cycles) standard conformity en 60947-5-2 indicating/operating means led green continuous: object in the measuring window flashing: object outside the measuring window led red error (e. g. interference level too high) electrical specifications rated operational voltage u e 10 ... 30 v dc without current output function 15 ... 30 v dc with current output function ripple 10 % ss power consumption p 0 2 w (all relays pulled-in, current output 20 ma) no-load power consumption 0.7 w output output type 2 relay outputs, 1 analogue output 4 ... 20 ma contact loading 60 v dc / 1 a (max. 24 w dc), ohmic lifetime electrical: 3 x 10 5 operating cycles at ohm. load (1 a / 24 v dc) mechanical: 10 7 operating cycles range hysteresis h 0 ... 15 % parameterisable repeat accuracy 0.1 % resolution 0.5 mm load impedance current output: 500 ohm deviation of the characteristic curve < 0.2 % of final value temperature influence 2 %, internal temperature compensation interface interface type rs 232, 9600 bit/s, no parity, 8 data bits, 1 stop bit ambient conditions ambient temperature -25 ... +70 c (248 ... 343 k) storage temperature -40 ... +85 c mechanical specifications protection degree ip65 according to en 60529 connection type 8-pin round connector, lumberg type rsf 8 material housing pbt mass 290 g current output 2 relays serial interfaces temperature compensation watchdog reverse polarity protection parameterisable standard symbol/connection: u +u b -u b rxd txd 1 2 4 6 7 3 5 led window bore holes for thread m4 (the delivery includes 4 pcs.) transducer 5 mm countersunk 117 100 5.5 5.5 41 52 22 134 100 30 m4 13 uc2000-f43-2kir2-v17 uc2000-f43-2kir2-v17 single head system
2 subject to reasonable modifications due to technical advances. copyright pepperl+fuchs, printed in germany pepperl+fuchs group tel.: germany (06 21) 7 76-0 usa (330) 4 25 35 55 singapore 7 79 90 91 internet http://www.pepperl-fuchs.com hinweise note ausgabedatum26.03.2001 model number characteristic curves/ additional information uc2000-f43-2kir2-v17 1.5 1.8 2.1 2.4 2.7 3.0 3.3 0.0 0.3 0.6 0.9 1.2 characteristic response curves distance [m] angle [degrees] curve 1: flat plate 100 mm x 100 mm curve 2: round bar, ? 25 mm 1 20 10 -0 -10 -20 90 80 70 60 50 40 30 2 thanks to its extensive command set, the sensor can be configured to suit the ap- plication via the rs 232 interface. rs 232 command set (overview) command meaning parameter access vs0 v elocity of s ound at 0 c velocity of sound at 0 centigrade vs0 in [cm/s] {10000 ... 60000) read and set vs v elocity of s ound velocity of sound vs in [cm/s] read to t emperature o ffset to in [0.1k] read and set tem tem perature tem in [0.1k] read and adapt to to ref ref erence measurement ref distance in [mm] {100 ... 4000} adaptation of vs0 sd1 s witching d istance 1 switching point, relay 1 sd1 in [mm] {100 ... 4000} read and set sd2 s witching d istance 2 switching point, relay 2 sd1 in [mm] {100 ... 4000} read and set sh1 s witching h ysteresis 1 hysteresis, relay 1 in [%] {0 ... 15} read and set sh2 s witching h ysteresis 2 hysteresis, relay 2 in [%] {0 ... 15} read and set nde n ear d istance of e valua- tion near measuring window limit in [mm] {100 ... 4000} read and set fde f ar d istance of e valuation far measuring window limit in [mm]{100 ... 4000} read and set br b lind r ange unusable area in [mm] {100 ... 4000} read and set cbt c onstant b urst t ime burst length in [s] {0,1, 2, 3} read and set cct c onstant c ycle t ime time in [ms] {0 ... 1000} read and set fto f ilter t ime o ut number of measurements without echo to be filtered {0 ... 255} read and set em e valuation m ethod evaluation method { 0 = none; pt1[,f,p,c]; mxn[,m,n]; dyn[,p] } read and set con con servative filter counter threshold as number {0 ... 255} read and set om o utput m ode om coded [normally-open no = 0, nor- mally-closed nc = 1] read and set fsf f ail s afe f unction failure function type e.g. fsf,11,35 {0,1,2}, [fault current in 0.1 ma] read and set md m aster d evice function as master {0 = none},ad,rd,rt,ss,adb,rdb,rtb } read and set ma m ain a pplication determines whether the green led orients itself according to nde, fde or sd1 and sd2 read and set nef n o e cho f ailure sensor behavior when no echo is present {0,1} read and set ad a bsolute d istance distance in [mm] read rd r elative d istance relative distance as number {0 ... 4095} read rt r un t ime echo run time in machine cycles [1 machine cycle = 1.085 s] read ss1 s witching s tate 1 ss1 binary [0: inactive, 1 active] (independ- ent of om) read ss2 s witching s tate 2 ss2 binary [0: inactive, 1 active] (independ- ent of om) read adb a bsolute d istance b inary distance in [mm] not as ascii read rdb r elative d istance b inary relative distance as number {0 ... 4095} not as ascii read rtb r un t ime b inary echo run time in machine cycles [1 machine cycle = 1.085 s] not as ascii read er e cho r eceived echo detected: no, yes [0/1] read ver ver sion version str ing: xxxx read id id entification id string: p&f uc2000-f43-2kir2-v17... read dat dat e date string: e.g. date: e.g. 04/12/99 time: 11:14:35 read st st atus status as hexadecimal string read rst r e s e t performs a reset command def def ault settings restores defaults command suc s tore u ser c onfiguration stores all settings command ruc r ecall u ser c onfiguration restores stored settings command basic setting om: relay 1: no relay 2: no sd1/sd2: switch point relay 1 = 100 mm switch point relay 2 = 2000 mm nde/fde: analogue output: 4 ma ? 100 mm 20 ma ? 2000 mm fsf: error ? relay 1 and 2: latest state ? analogue output: i out = 3,9 ma nef: no echo ? error message ma,s: switching mode
|