Part Number Hot Search : 
LT1117CM HEF4093B BAR66 UF2001G MBR352W AA2090 004CD 2N2369
Product Description
Full Text Search
 

To Download 2116 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  ...with improved timer ovens chillers sterilisers trace heating heat sealing 2132 2116 models pid temperature controllers eurotherm ontrols universal input covers a wide range of temperature and process inputs self tuning easy commissioning in-built timer sets heating/cooling times setpoint rate limit provides ramp-dwell heat treatment profile tactile buttons friendly to use wide-range 85-264v ac, can be installed world-wide or 20-29vac/dc supply plug-in from front rapid replacement - reducing downtime ip65 and nema 4x can be used in wet and dusty atmospheres panel sealing three year warranty low ownership cost ideal for: features: model 2132 1/32 din (48 x 24mm) model 2116 1/16 din (48 x 48mm) available in compact 1/32 and 1/16 din panel sizes, the 2132 and 2116 temperature controllers are designed for accurate, trouble free control of ovens, chillers, sterilisers and other simple heating and cooling processes. two outputs are configurable for heating, cooling and alarms. eurotherms advanced control techniques give stable straight-line temperature control. self tuning is included to optimise the control performance without the need for specialist knowledge or training. heater failure can be detected when the controller is used with a eurotherm te10s solid state relay (requires pdsio mode 1). three internal alarm setpoints are provided, configurable as latching or non-latching. alarms can be blocked on start-up to prevent unnecessary operator alerts. calibration accuracy is maintained with a self-correcting input circuit. user calibration allows offsets to be applied to compensate for sensor and other system errors. improved timer an improved timer can apply heating (and cooling) for a pre-set period, or delay heating to come on after a set time. the latter is useful for over-night batch processing. pid temperature controllers
part no. ha026158 issue 2 2132 op1 op2 electrical connections 2132 2116 specifications supply voltage: 85-264vac, 48-62hz, or 20-29vac/dc, 5watts max operating ambients: 0-55?, 5-95%rh non-condensing output ratings: logic: 9vdc, 12ma (non-isolated) (can also be used as alarm acknowledge, keylock and timer start/stop input) relay: 2a, 264v ac resistive calibration accuracy: 1? or 0.25% of reading whichever is greater cold junction compensation: >15 to 1 rejection of ambient temperature change input filtering: off to 999.9 seconds 2116 op1 op2 48 mm (1.89in) 48 mm (1.89in) 103 mm (4.01in) panel cut-out - 0.0 + 0.6 45 x 45 mm panel cut-out - 0.0 + 0.3 22.2 x 45 mm 103 mm (4.01in) 48 mm (1.89in) 24 mm (0.95in) dimensions 2132 2116 line neutral 85-264vac outpt 2 (relay) t/c pt100 1a 1b + ma input sensor inputs or - v- v+ ab aa n l 2.49 external relay module output 1 (logic) solid state relay 1a 1b 24 24 20-29vac/dc low voltage supply timer range: 0-9999 minutes setpoint rate limit adjustment: 0-999.9 least significant display unit per minute. adjustable hysteresis alarm configuration: high, low, deviation band, deviation high and low emc standards: meets generic emissions standard en50081-2 and immunity standard en50082-2 for industrial environments safety standard: meets en61010, installation category ii. pollution degree 2 atmospheres: not suitable for use above 2000m or in explosive or corrosive atmospheres line neutral output 2 (relay) l n ab v+ v- t/c pt100 output 1 (logic) aa 1a 1b + - ma input sensor inputs external relay module 2.49 solid state relay or 1a 1b 85-264vac 24 24 20-29vac/dc low voltage supply - 0.0 + 0.6 1.77 x 1.77in - 0.00 + 0.02 0.88 x 1.77in - 0.0 + 0.01 - 0.0 + 0.02 ?copyright eurotherm controls limited 1997 all rights strictly reserved. no part of this document may be stored in a retrieval system, or any form or by any means without prior written permission from eurotherm controls limited. every effort has been taken to ensure the accuracy of this specification. however in order to maintain our technological lead we are continuously imp roving our products which could, without notice, result in amendments or omissions to this specification. we cannot accept responsibility for damage, injury, loss or expenses resulting therefrom. eurotherm controls limited http://www.eurotherm.co.uk uk sales office eurotherm controls limited. faraday close, durrington, worthing, west sussex bn13 3pl telephone sales: (01903) 695888; technical: (01903) 695777; service: (01903) 695444 fax (01903) 695666 sales and support in over 30 countries worldwide enquiries/orders to: eurotherm controls limited export dept., faraday close, durrington, worthing. west sussex bn13 3pl. telephone (01903) 268500, fax (01903) 265982 vh 85-264vac vl 20-29v dc or ac manual xxx no manual eng english fra french ger german ned dutch spa spanish swe swedish ita italian output 1 (logic) function cc pid controller nf on/off controller tc pid controller + timer tn on/off contr?+ timer sensor input setpoint min/max units c ? f ? k kelvin x linear input ordering code external relay module xx not fitted r7 fitted (operated by the logic output) input adaptor xx not fitted v1 0-10vdc a1 0-20ma or 4-20ma 0.1% current sense resistor (2.49 ) supply voltage model number function supply voltage manual output 1 (logic) output 2 (relay) sensor input note 2 setpoint min. note 2 setpoint max. units ext. relay module input adaptor xx no function logic output lh heating lc cooling m1 pds heater break detect (note 1) fh high alarm 1 fl low alarm 1 db dev. band alarm 1 dl dev. low larm 1 dh dev. high alarm 1 nw new alarm logic input ac alarm ack/reset kl keylock tm timer off/on thermocouples min ? max j type j -210 to 1200 k type k -200 to 1372 t type t -200 to 400 l type l -200 to 900 n type n -200 to 1300 r type r -50 to 1768 s type s -50 to 1768 b type b 0 to 1820 p platinell ii 0 to 1369 resistance thermometer z pt100 -200 to 850 custom downloaded inputs c type c - w5%re/w26%re 0 to 2319 (default custom sensor) d type d - w3%re/w25%re 0 to 2399 e e thermocouple -200 to 999 1 ni/ni18%mo 0 to 1399 2 pt20%rh/pt40%rh 0 to 1870 3 w/w26%re (englehard) 0 to 2000 4 w/w26%re (hoskins) 0 to 2010 5 w5%re/w26%re (englehard) 10 to 2300 6 w5%re/w26%re (bucose) 0 to 2000 7 pt10%rh/pt40%rh 200 to 1800 8 exegen k80 i.r. pyrometer -45 to 650 process inputs (linear) m -9.99 to +80mv -1999 to 9999 y 0 to 20ma (note 3) -1999 to 9999 a 4 to 20ma (note 3) -1999 to 9999 v 0 to 10vdc (input adapter required) -1999 to 9999 note 2. setpoint min and max: include the decimal position required in the display value; up to one for temperature input, up to two for process inputs. note 3. an external 1% current sense resistor is supplied as standard. if greater accuracy is required specify ?1 in the input adaptor field. 2132 48 x 24mm unit 2116 48 x 48mm unit model number output 2 (relay) xx no function rh heating rc cooling fh high alarm 2 fl low alarm 2 al high alarm 2 & low alarm 3 db dev. band alarm 2 dl dev. low larm 2 dh dev. high alarm 2 nw new alarm note 1. pds heater break detect will transmit the power demand to a te10s solid state relay and read beck a heater break alarm.


▲Up To Search▲   

 
Price & Availability of 2116

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X