3m electronic handling and protection division 6801 river place blvd. austin, tx 78726-9000 test & burn-in grid zip sockets pin grid arrays 7 ts-0358-1 2 shee t 1 of 4 date issued: november 1, 1999 physical insulation material: polyethersulfone (pes) flammability : ul 94 v -0 color : black (pes) marking : part number identifier and logo on all cam handle material : stainless steel contact material : beryllium copper plating : 30 m " (0.76 m m) gold mil-g-45204, t ype ii, grade c, over 50 m " (1.3 m m) nickel qq-n-290a, class 2 electrical cur r ent rating : 1 amp insulation resistance : > 1 10 12 w at 500 vdc w ithstanding v oltage : 1000 v rms at sea level environmental operating t emperatu r e rating : pes : - 5 5 c to + 15 0 c mechanical pes/bec u a. when used as a test socket at room temperature 2 4 c the socket will last 25,000 actuations. b. based on field experience, under normal burn-in conditions up to a maximum of 150 c for pes, the socket should last an average of four years. lever actuated zero insertion force mechanism rugged 3-plate construction for durability and electrical reliability available in 10 x 10 through 25 x 25 matrices ptfe coated stainless steel handle - durable and safe in high humidity environment optical locating holes for robotics loading/unloading repairable - contacts, handles, top-plate, and cam plate are replaceable available with flush handle option for use with test probes and ease of board stacking for technical, sales or ordering information call 800-328-041 1 or visit our website: http://www.3m.com/ehpd
3m electronic handling and protection division 6801 river place blvd. austin, tx 78726-9000 t est & burn-in grid zip sockets pin grid arrays a b .02 [ 0.5 ] g closed .50 [ 12.7 ] .26 ref [ 6.5 ] 4x #0-80 x 5/16 long phillips pan-hd (requires .070 [1.78] dia clearance hole) #0-80 5/16 phillips pan hd optic pickup 2x dia. .062 [ 1.58 ] .20 [ 5.1 ] .10 [ 2.5 ] d e c 90 .40 [ 10.3 ] .02 [ 0.5 ] .40 [ 10.2 ] .010 x .028 [ 0.25 ] [ 0.71 ] contact t ail .100 t yp [ 2.54 ] .13 [ 3.3 ] .21 [ 5.3 ] .3 [ 8.0 ] f open ts-0358-12 sheet 2 of 4 ordering information 2xxx-63xx-xxx-1902 number of contacts 6310 10x10 6311 11x11 6313 13x13 6315 15x15 6317 17x17 6319 19x19 6321 21x21 6325 25x25 0ua = molded pattern, standard handle 9ua = all holes open, standard handle 0ra = molded pattern, flush cam handle 9ra = all holes open, flush cam handle plating pes: 1902 with / 30 " au/ni on becu notes: 1 25 x 25 only . 1 present only on 15 x 15 and larger . c l open closed note: ten hole plugs can be ordered separately part #200-4660-14-1 900. (mm) (.00) ( .25) ( .13) t olerance .010 .005 .000 t olerance dimension .00 (.0) inch 1.00 [ 25.4 ] 2 for technical, sales or ordering information call 800-328-041 1 or visit our website: http://www.3m.com/ehpd 2
3m electronic handling and protection division 6801 river place blvd. austin, tx 78726-9000 t est & burn-in grid zip sockets pin grid arrays grid matr ix maximum contact dimensions dimension g cam handle matrix contact quantity a b c d e f standard **flush 10 x 10 100 1.70 [ 43.2 ] .90 [ 22.9 ] 1.15 [ 29.2 ] 1.50 [ 38.1 ] .90 [ 22.9 ] .80 [ 20.3 ] .80 [ 20.3 ] 1.00 [ 25.4 ] 1 1 x 1 1 121 1.80 [ 45.7 ] 1.00 [ 25.4 ] 1.25 [ 31.8 ] 1.60 [ 40.6 ] 1.00 [ 25.4 ] .80 [ 20.3 ] .80 [ 20.3 ] 1.00 [ 25.4 ] 13 x 13 169 2.00 [ 50.8 ] 1.20 [ 31.8 ] 1.45 [ 36.8 ] 1.80 [ 45.7 ] 1.00 [ 25.4 ] .80 [ 20.3 ] .80 [ 20.3 ] 1.00 [ 25.4 ] 15 x 15 225 2.20 [ 55.9 ] 1.40 [ 35.6 ] 1.65 [ 41.9 ] 2.00 [ 50.8 ] 1.20 [ 30.5 ] 1.30 [ 33.0 ] 1.40 [ 35.6 ] 1.50 [ 38.1 ] 17 x 17 289 2.40 [ 61.0 ] 1.60 [ 40.6 ] 1.85 [ 47.0 ] 2.20 [ 55.9 ] 1.20 [ 30.5 ] 1.30 [ 33.0 ] 1.40 [ 35.6 ] 1.50 [ 38.1 ] 19 x 19 361 2.60 [ 66.0 ] 1.80 [ 45.7 ] 2.05 [ 52.1 ] 2.40 [ 61.0 ] 1.40 [ 35.6 ] 1.70 [ 43.2 ] 1.80 [ 45.7 ] 1.90 [ 48.2 ] 21 x 21 441 2.80 [ 27.1 ] 2.00 [ 50.8 ] 2.25 [ 57.2 ] 2.60 [ 66.0 ] 1.40 [ 35.6 ] 1.70 [ 43.2 ] 1.80 [ 45.7 ] 1.90 [ 48.2 ] 25 x 25 625 3.70 [ 94.0 ] 2.40 [ 61.0 ] 2.65 [ 67.3 ] 3.50 [ 88.9 ] 2.00 [ 50.8 ] 2.58 [ 65.5 ] 2.78 [ 70.6 ] 2.78 [ 70.6 ] **for -0ra and -9ra flush cam handle option only ts-0358- 12 sheet 3 of 4 .12 [ 3.0 ] g .26 [ 6.5 ] .4 [ 10.0 ] #0-80 phillips pan-hd 4x #0-80 x 5/16 long phillips pan-hd 2 flush cam handle option fo r technical, sales or ordering information cal l 800-328-041 1 or visit our website : http://www.3m.com/ehpd
3m electronic handling and protection division 6801 river place blvd. austin, tx 78726-9000 t est & burn-in grid zip sockets pin grid arrays holes with contacts handle side front 10 x 10 1 1 x1 1 13 x 13 15 x 15 17 x 17 19 x19 21 x 21 25 x 25 to p mark indications: no holes, no contacts holes only , no contacts ts-0358-1 2 sheet 4 of 4 notes: 1. this is only a work sheet. do not proceed with any layout un til a part number is assigned by t extool. the pattern is subject to repositioning. 2. lead diameter = .022 [ 0.56 ] max, .014 [ 0.36 ] min. the s tandard socket has been designed to accept these lead diameters only . for all others please consult the factory . 3. use this sheet to indicate which positions you intend to us e. 4. remember: for best results, keep your patterns as symmetric al with the centerline as possible. 5. the contact point for all sizes is .085 [ 2.16 ] below th e top surface and we recommend a device lead length of .100 [ 2.54 ] below the solder stan do f fs. fo r technical, sales or ordering information cal l 800-328-041 1 or visit our website : http://www.3m.com/ehpd
|