  tektronix measurement solutions combo sel gdv.2for pdf 4/1/98 3:38 pm page 1
applications ? installation and maintenance of industrial and communications equipment ? preventive maintenance programs ? manufacturing process troubleshooting ? design verification and debug wstrm C optional pc interface package ? wavestar ? for meters software ? optically-isolated pc interface cable provides communication between tx dmm and pc rs-232 port 2 new tx-dmm ? true rms digital multimeters accessories refer to pages 12 and 13 for the new atl25 adjustable test lead set and other meter accessories. all tektronix meters have a 3 year warranty. save time and money without sacrificing quality, safety, or ruggedness the tx-dmm family can save you valuable time in the field. its extra large display with backlight can be viewed from across the room. making measurements is quick and easy with an innovative single input, single knob location interface. dual display shows more information in fewer steps make ac and dc measurements without changing the meter function. the tx-dmm family provides the features and performance you need in an affordable package. tx-dmm technology provides high accuracy, high resolution, and a wide measurement range as well as fast rms settling time. each meter comes in a re-usable clamshell case and includes a traceable calibration certificate. the tx3 adds a built-in digital thermometer and k-type thermocouple probe. made in usa combo sel gdv.2for pdf 4/1/98 3:38 pm page 2
specifications tx1 tx3 true rms yes yes backlit display yes yes display counts (selectable) 50,000 and 5,000 50,000 and 5,000 ac,dc, and (ac+dc) volts and amps; yes yes resistance, continuity, diode test, capacitance, frequency, duty cycle basic dc volts accuracy 0.07% + 1ct 0.05% + 1ct min/max/avg/max-min recording yes yes with time stamp 1 ms peak hold yes yes computer calibrated with "cal date" readout *yes *yes dual readout yes yes simultaneous ac and dc readout *yes *yes 50 range with automatic lead calibration *yes *yes non-volatile memory locations *10 *30 temperature measurement (k-type) C *probe standard dbm and db readings C yes 4C20 ma process loop with % readout C *yes setup menu with custom defaults yes yes safety certifications ce, ul, csa ce, ul, csa safety voltage rating *1000 v - catiii *1000 v - catiii traceable calibration certificate standard *yes *yes *feature unique to tx digital multimeters. safe, easy access allows fast battery replacement without breaking the calibration seal. rugged boot with versa-stand ? provides a versatile hook-stand for convenient, hands-free operation anywhere. 3 data logging use a tx-dmm meter with the optional wstrm pc interface package for data logging of temperature (tx3 only), voltage, or current variations on critical circuit components. store it error-free data collection is crucial to preventive maintenance programs. use the tx-dmm mem function to store up to 30 measurements in the field. download it use wstrm to automatically download measurements to your pc. document it track and document measurements using wavestar for meters software and other windows ? applications. combo sel gdv.2for pdf 4/1/98 3:39 pm page 3
4 digital multimeters accessories see pages 12 C 13 all tektronix meters have a 3 year warranty. specifications dmm912 dmm914 dmm916 true rms yes yes yes backlit display C C yes display counts (selectable) 40,000 and 4,000 40,000 and 4,000 40,000 and 4,000 ac,dc, and (ac+dc) volts and amps; resistance, yes yes yes continuity, diode test, capacitance, frequency duty cycle yes yes basic dc volts accuracy (4000 ct mode) 0.2% + 1ct 0.1% + 1ct 0.06% + 1ct temperature measurement (k-type) C yes yes probes sold separately min/max/avg/max-min recording with time stamp no time stamp yes yes 1ms peak hold C C yes average responding ac readout *yes *yes *yes dual readout yes yes dbm and db readings yes center/zoom analog bar graph *yes *yes hi/lo limits *yes *yes delta % readout *yes *yes setup menu with custom defaults yes yes yes safety certifications ce, ul, csa ce, ul, csa ce, ul, csa dual safety voltage ratings 600 v C catiii 600 v C catiii 600 v C catiii 1000 v C catii 1000 v C catii 1000 v C catii *feature unique to dmm900 specifications dmm249 dmm254 dmm150 dmm157 display counts 3200 4000 3200 3200 true rms yes yes basic dc volts accuracy 0.3% + 2 cts 0.1% + 2 cts 0.7% + 2 cts 0.5% + 2 cts ac voltage ranges 3 C 750 v 400 mv C 750 v 3 C 600 v 3 C 600 v dc voltage ranges 300 mv C 1000 v 400 mv C 1000 v 300 mv C 600 v 300 mv C 600 v dc current ranges 300 a C 20 a 4 ma C 10 a 300 a C 10 a ac current ranges 300 a C 20 a 4 ma C 10 a 300 a* 300 a C 10 a resistance ranges 300 C 30 m 400 C 40 m 300 C 30 m 200 C 20 m capacitance ranges 4 nf C 40 f 3 C 3000 f frequency ranges 100 hz C 1 mhz analog bargraph display yes yes yes yes diode test yes yes yes yes continuity check yes yes yes yes safety iec, ul, csa iec, ul, csa iec, ul, csa iec, ul, csa * with optional cmm150 clamp probe combo sel gdv.2for pdf 4/1/98 3:39 pm page 4
5 clamp meters, digital thermometers dcm320 features: ? true rms ac measurements ? autoranging applications: ? troubleshoot plant electrical systems ? verify building power systems ? install electrical equipment dcm910 features: ? 1000 a rating for industrial measurements ? hall effect transducer provides accurate dc readings applications: ? maintain industrial equipment ? troubleshoot adjustable speed drives ? install motor drives specifications dtm900 dtm920 thermocouples k j or k channels 1 2 accuracy (single input) (0.2% + 1c) (0.1% + 0.7c) accuracy (t1-t2) (0.3% + 2.2c) resolution 0.1/1c 0.1/1c temperature range -50 to +1300c -200 to +1370c measurement hold yes yes record max/min yes/no yes/yes differential (t1-t2) yes autoranging yes stopwatch yes dimensions (lxwxd) 170 x 74 x 39 mm 170 x 74 x 39 mm weight 431 g* 431 g* * includes 131 g holster dtm900 features: ? intuitive layout provides easy access to all functions ? maximum feature captures extreme measurements applications: ? food process monitoring ? verify heating in electronic components dtm920 features: ? dual-channel and differential temperature measurements ? stopwatch easily tracks temperature measurements over time ? intuitive layout provides easy access to all functions applications: ? monitoring process control equipment ? troubleshooting hvac-r systems specifications dcm320 dcm910 display counts 4000 4000 ac voltage ranges 400 C 600 v frequency 40 C 500 hz accuracy 1.20% + 5 cts ac current ranges 400 C 600 a 40 C 1000 a frequency 50/60 hz 40 C 400 hz accuracy 1.90% + 5 cts 1.90% + 8 cts dc current ranges 400 C 1000 a accuracy 1.90% + 10 cts resistance ranges 4 C 40 k accuracy 2.0% + 9 cts frequency ranges 4 C 10 khz accuracy 0.50% + 3 cts autoranging yes yes true rms yes yes crest factor up to 2.5 up to 3 continuity beeper yes (<100 ) hold display peak hold jaw size (diameter) 40 mm 51 mm safety iec, ul, csa iec, ul, csa transducer transformer hall effect accessories see pages 12 C 13 all tektronix meters have a 3 year warranty. combo sel gdv.2for pdf 4/1/98 3:39 pm page 5
the tekscope ? ths700 series combines a digital real-time oscilloscope with a true rms digital multimeter in a rugged handheld package. scope and meter modes operate simultaneously or independently on the same or separate signals. features include: high resolution backlit display, cursors, voltage and resistance measurements, and storage of waveforms, data, and instrument setups. take floating measurements, not risks using proprietary isolatedchannel ? architecture, you can safely acquire both channels even when they are referenced to different or dynamically changing potentials. both oscilloscope channels and dmm are independently isolated. catch glitches pulse trigger and a fast sample rate reveal glitches that go undetected with lower sample rates. see what really happens a fast update rate and digital real-time acquisition keep pace with changes, delivering digital precision with an analog look. specifications ths710a ths720a ths730a bandwidth 60 mhz 100 mhz 200 mhz sample rate 250 ms/s 500 ms/s 1 gs/s per channel channels 2 2 2 digitizers 2 2 2 record length 2500 points 2500 points 2500 points glitch capture 8 ns 8 ns 8 ns isolated channels yes yes yes ce marked yes yes yes standard 10x probes (2) p6117 p6117 p6117 triggering external, video, and pulse width meter resolution 4000 counts, 3-3/4 digits maximum float voltage 600 v rms each channel dc volts yes yes yes true rms ac volts yes yes yes resistance yes yes yes diode test yes yes yes continuity check yes yes yes 6 handheld digital oscilloscopes accessories ? ths7hca hard carrying case ? ths7bat battery ? ths7chg battery charger ? wstr31/wstr31u wavestar ? electronic lab notebook software additional accessories see page 12 compatible probes see pages 12 C 15 combo sel gdv.2for pdf 4/1/98 3:40 pm page 6
the tekscope ths720p with isolatedchannel ? architecture and built-in dmm is ideal for electric/power electronics applications. the ths720p has all of the ths720a features, plus power and harmonic measurement capabilities to test and verify operation of motors, transformers, power supplies, and the effects of harmonics. the ths720p has specialized triggering for pwm ac motors. measure harmonic content the ths720p bar graph displays harmonic content of each of the harmonic frequencies including the fundamental (fundamental frequency from 30 C 450 hz) up to the 31st. power measurements made easy simply press math to display the statistics of the same signal shown above, including power factor and other power measurements. specifications ths720p bandwidth 100 mhz sample rate 500 ms/s per channel number of channels 2 digitizers 2 record length 2500 points glitch capture 8 ns isolated channels yes ce marked yes harmonics yes power measurement yes and statistics standard probes (2) p5102 high voltage triggering external, video, pulse width, motor safe power measurements 7 combo sel gdv.2for pdf 4/1/98 3:40 pm page 7
multilingual menus and help display text in english, french, german, italian, japanese, korean, portuguese, simplified chinese, spanish, and traditional chinese. interface modules plug-in modules for printing, communications, and control. includes wavestar ? lite software. ? tds2hm centronics ? tds2cm centronics, gpib, rs-232-c ? tds2mm fft/measurements, centronics, gpib, rs-232-c the tds 200 digital real-time ? oscilloscopes will change the way you think about low-cost oscilloscopes. compare performance, portability, and value: autotriggering, zoom, automatic measurements, save and recall of waveforms and setups, math functions, and crisp liquid crystal display. specifications tds 210 tds 220 bandwidth 60 mhz 100 mhz channels 2 2 max sample rate 1 gs/s 1 gs/s per channel sweep speeds 5 ns/div C 5 s/div 5 ns/div C 5 s/div vertical accuracy 3% 3% vertical resolution 8 bits 8 bits record length 2.5k points/channel 2.5k points/channel vertical sensitivity 10 mv/div C 5 v/div at full bandwidth, 2 mv/div C 5 mv/div at 20 mhz features automatic measurements, 2 reference waveforms, peak detect, autoset, multi-language user interface, 5 setup memories, two p6112 probes, certificate of calibration digital real-time oscilloscopes 8 the huntron tracker ? tr210 works with oscilloscopes like the tds 200 to simplify the troubleshooting of populated circuit boards in a power off condition, including cmos and mos circuits. the built-in pulse generator makes it possible to evaluate gate-fired devices such as scrs, triacs, and opto-couplers. specifications huntron tracker tr210 test frequencies 50 C 60 hz, 200 hz, 2 khz functions range selection, high range lockout compare-a-trace 0.5 C 10 hz pulse level 0 C 5 v dc mode +dc or -dc pulse mode +pulse, -pulse, or both power requirement 100 vac, 115 vac, 230 vac; 47 C 63 hz accessories ? ac220 soft carrying case ? rm200 rackmount kit compatible probes see pages 13 C 15 combo sel gdv.2for pdf 4/1/98 3:41 pm page 8
optional wavestar ? for oscilloscopes software windows ? 95/nt application allows you to capture, analyze, document, and control oscilloscope waveforms and measurements. wavestar is compatible with all tds and ths series oscilloscopes with gpib or rs-232 interfaces. ? wstro wavestar for oscilloscopes, windows 95/nt version ? wstrou upgrade from wstr31 to wstro ? wstr31 windows 3.1 version accessories ? soft-sided carrying case (016-1158-01) ? hard transit case (016-0792-01) ? deluxe transit case with retractable wheels and handle (016-1157-00) ? accessory pouch (016-1159-00) ? front cover (200-3232-01) ? rackmount kit (016-1166-00) compatible probes see pages 13 C 15 fft analyze signal harmonics; evaluate distortion and symmetry. acquisition modes video and edge triggering with 4 acquisition modes: sample, envelope, average, and peak detect. the tds 300 digital real-time oscilloscopes offer a wide range of circuit design and test utilities, including fft analysis. store waveforms and setups in a wide range of formats and transfer files to your pc using the floppy disk drive or the optional communications interface. specifications tds 340a tds 360 tds 380 bandwidth 100 mhz 200 mhz 400 mhz sample rate 500 ms/s 1 gs/s 2 gs/s per channel sweep speeds 5 ns/div C 5 s/div 2.5 ns/div C 5 s/div 1 ns/div C 5 s/div record length 1k points/channel 1k points/channel 1k points/channel standard probes (2) p6109b p6111b p6114b features tv line & field trigger, roll mode, autoset, peak detect, 21 automatic measurements, fft, disk drive, certificate of calibration option 14 rs-232, gpib, vga monitor output, centronics-type parallel printer port 9 combo sel gdv.2for pdf 4/1/98 3:41 pm page 9
10 power supplies specifications ps2520g ps2521g output type triple triple voltage range 0 C 6 v (one) 0 C 6 v (one) 0 C 36 v (two) 0 C 20 v (two) maximum current 3 a (6 v)/1.5 a (36 v) 5 a (6 v)/2.5 a (20 v) gpib programmable yes yes front panel yes yes programmable over voltage protection yes yes over current protection yes yes serial, parallel yes yes independent modes cps250 ps280 output type triple triple one fixed output/ 5 v 5 v maximum current 2 a 3 a two variable output/ 0 C 20 v 0 C 30 v maximum current 0.5 a 2 a variable current limiting yes yes overload indicator yes serial, parallel yes independent modes expect safe, reliable performance every time you turn on a tektronix power supply. proven design and top quality components set these instruments apart from the competition. choose from manual or programmable models to meet your design, test, or lab requirements. combo sel gdv.2for pdf 4/1/98 3:41 pm page 10
11 function generators, frequency counter, digital multimeter function generator specifications cfg253 cfg280 frequency range 0.03 hz C 3 mhz 0.01 hz C 11 mhz output sine, square, sine, square, triangle, ttl pulse triangle, ttl pulse internal or external sweep yes yes built-in 100 mhz counter yes vfc (fm) input yes am input yes, ext. sinewave sync out yes yes counter specifications cmc251 frequency range ch a 1 hz C 100 mhz frequency range ch b 80 mhz C 1.3 ghz stability 1 ppm sensitivity (rms) 5 C 35 mv period yes pulse width yes totalize yes dmm specifications cdm250 ac/dc volts ranges 200 mv C 500 v dc volts accuracy 0.5% of rdg + 2% of full scale ac/dc current ranges 200 a C 10 a resistance ranges 200 C 20 m display 3-1/2 digit led overrange indication yes sony/tektronix programmable arbitrary function generators output a wide variety of waveforms for design and manufacturing test. specifications afg310 afg320 independent channels 1 2 frequency range 10 mhz C 16 mhz arbitrary waveform sample rate 16 ms/s vertical resolution 12 bits waveform memory 4 x 16k output level (50 ) 50 mv p-p C 10 v p-p output modes continuous, triggered, burst output waveforms sine, square, triangle, ramp, pulse, dc, noise waveform editing software yes linear/log sweep yes am/fm/fsk modulation yes gpib programmable yes combo sel gdv.2for pdf 4/1/98 3:42 pm page 11
12 accessories handheld instrument accessories description dmm100/200 dmm900 tx-dmm dtm900 dcm320 ths700 atldx1 deluxe lead set ? ? ? ? ? atl01 standard dmm test leads ? ? ? ? ? atl21 shielded banana plug leads ? ? ? ? ? atl22 test lead tips ? ? ? ? ? atl23 sharp ic test lead tips ? ? ? ? ? atl25 adjustable test lead set ? ? ? ? ? acl21 alligator clips ? ? ? ? ? acl22 hook-tip clips ? ? ? ? ? acl23 wire clamp clips ? ? ? ? ? acl24 jaw clips ? ? ? ? ? ac11 soft case ? ? ac12 large soft case ? ? ? ac13 long soft case ????? atk01 thermocouple adapter ? ? atp01 temperature probe ? ? ? a605 ac current probe, 500 a ? ? ? a621 ac current probe, 2,000 a ? ? ? a622 ac current probe, 100 a ? ? ? cmm150 ac current clamp probe, 300 a dmm150 only atldx1 atl21 atl22 acl21 acl22 acl23 acl24 cmm150 new ! atl25 combo sel gdv.2for pdf 4/1/98 3:42 pm page 12
probe/scope compatibility probe description tds 200 tds 300 ths700 voltage passive 1x p6101b p6101b p6101b voltage passive 10x p6112 p6109b p6117 p6111b p6114b voltage passive 1x/10x p6119b* p6129b* high voltage passive 10x p5102 high voltage passive 100x p5100 p5100 high voltage passive 1000x p6015a p6015a voltage passive smd p6561a p6562a specialty logic p6408 p6408 differential high voltage p5200 p5200 differential (v) ada400a ada400a voltage active probe p6243s p6243s current measurement ac p6021 p6021 a605 (dmm) a621 a621 a621 (scope) current measurement ac/dc am503s am503s a622 (scope) a622 a622 * not ce listed current probes specifications a605 a621 a622 cmm150 frequency range 48 hz to 1 khz 5 hz to 50 khz dc to 100 khz maximum input current 500 a peak 2000 a peak 100 a peak 300 a ac rms output 1 mv/a 1 mv/a 10 mv/a 1 mv/0.1 a 10 mv/a 100 mv/a 100 mv/a maximum conductor 30 mm 54 mm 11.8 mm 29 mm diameter (1.18 inch) (2.13 inch) (0.46 inch) (1.14 inch) connector type shielded banana bnc bnc (bnc to shielded (bnc to shielded banana adapter) banana adapter) instrument compatibility dmm dmm, ths700 dmm, ths700 dmm150 current probe systems am503s am503s am503s specifications with a6302 probe with a6303 probe with a6304xl probe bandwidth 50 mhz* 15 mhz 2 mhz maximum continuous 20 a 100 a 500 a peak pulse 50 a 500 a 700 a cable length 2 m 2 m 8 m * 100 mhz with optional a6312 probe 13 ac13 ac11 atp01 atk01 a621 a622 a605 ac12 combo sel gdv.2for pdf 4/1/98 3:43 pm page 13
14 accessories passive voltage probes specifications p6101b p6103b p6109b p6111b p6112 p6114b bandwidth (mhz) 15 60 100 200 100 400 attenuation 1x 10x 10x 10x 10x 10x compensation range n/a 15 C 35 pf 15 C 35 pf 15 C 35 pf 15 C 35 pf 15 C 35 pf readout yes yes yes scope compatibility all all tds 300/tds 400a tds 360 tds 200 tds 380 * not ce listed active probes specifications p6201 p6202a p6205 p6243* attenuation 1x/10x/100x 10x/100x 10x 10x bandwidth at -3 db 900 mhz 500 mhz 750 mhz 1 ghz dc offset range 5.6/56/200 v 55/200 v n/a n/a system input 100 k /1 m /1 m 10 m 1 m 1 m resistance typical input c 3/1.5/1.5 pf 2/2 pf 2 pf < 1 pf maximum voltage 100/200 v 200/200 v 40 v 40 v probe power supply 1101a 1101a 1103 1103 for 2205, tas, and tds 300 scopes * p6243s includes two p6243 probes and one 1103 tekprobe ? power supply. probe power supplies probe power supplies provide external power to probes when the oscilloscope does not. specifications 1103 1101a probes ada400a, P5205, p6204, p6201, p6202a p6205, p6217, p6243, p6245 probe inputs 2 2 bnc outputs 2 tekprobe ? interface yes voltage offset switches 2 potentiometers 2 overload protection yes yes scope compatibility tds 200, tds 300, 2205, tas 200 1103 p6243 p5102 p6015a p6112 combo sel gdv.2for pdf 4/1/98 3:43 pm page 14
15 passive high voltage probes specifications p5100 p5102 p6015a attenuation 100x 10x 1000x bandwidth 250 mhz 100 mhz 75 mhz loading 10 m /2.75 pf 5 m /11.2 pf 100 m /3 pf dc maximum 2.5 kv 1.0 kv 20 kv length 10 ft ( 3m) 2m ( 6.6 ft) 10 ft ( 3m) comp. range 7 C 30 pf 24 C 28 pf 7 C 49 pf readout yes no option 1r active differential probes specifications p5200 P5205 ada400a attenuation 50x/500x 50x/500x n/a gain n/a n/a 0.1x, 1x, 10x, 100x bandwidth 25 mhz 100 mhz 1 mhz bandwidth filters n/a n/a 100 hz, 3 khz, 100 khz maximum input 1300 v (dc + peak ac) 1300 v (dc + peak ac) 80 v @ 0.1x, differential 10 v @ 1x, 1 v @ 10x, voltage (v dm ) 100 mv @ 100x maximum input voltage 1000 v 1000 v 40 v @ 0.1x, to ground (v cm ) (dc + peak ac) (dc + peak ac) 40 v @ 1x, 10 v @ 10x, 10 v @ 100x input r (each input) 4 m 4 m 1 m , selectable ? mode input c (each input) 7 pf 7 pf 55 pf cmrr 80 db (10,000:1) 50 db (1,000:1) > 100 db (100,000:1) (common mode @ 60 hz; @ 1 mhz @ 10 khz; rejection ratio) 50 db (1,000:1) > 90 db (30,000:1) @ 100 khz @ 100 khz cable length 1.8 m (6 ft) 1.8 m (6 ft) 2 m (6.6 ft) operating power ac power adapter tekprobe tekprobe included power interface power interface p6117 p6119b* p6129b* p6561a yt5100* yt5060* 200 10/100 10/100 200 100 60 10x 1x/10x 1x/10x 10x 1x/10x 1x/10x 15 C 35 pf 15 C 35 pf 15 C 35 pf 15 C 35 pf 20 C 45 pf 20 C 45 pf yesyes ths700 tds 300/tas 200 all tds 300/tas 400 all all p6117 P5205 p5200 combo sel gdv.2for pdf 4/1/98 3:44 pm page 15
contents digital multimeters . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 digital thermometers . . . . . . . . . . . . . . . . . . . . . . . . . 5 handheld digital oscilloscopes . . . . . . . . . . . . . . . . . 6 bench oscilloscopes . . . . . . . . . . . . . . . . . . . . . . . . . . 8 bench instruments . . . . . . . . . . . . . . . . . . . . . . . . . . 10 accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 5/98 wci 3mw-10858-3 copyright ? 1998, tektronix, inc. all rights reserved. tektronix products are covered by u.s. and foreign patents, issued and pending. information in this publication supersedes that in all previously published material. specification and price change privileges reserved. tektronix, tek, tekprobe, and tekscope are registered trademarks and tx-dmm, versa-stand, digital real-time, wavestar, and isolatedchannel are trademarks of tektronix, inc. all other tradenames referenced are the service marks, trademarks, or registered trademarks of their respective companies. for further information, contact tektronix: from other areas, contact: tektronix, inc. export sales p.o. box 500, m/s 50-255 beaverton, oregon 97077-0001 usa 1 (503) 627-6877 visit our world wide web site: http://www.tek.com asean countries (65) 356-3900 australia & new zealand 61 (2) 888-7066 austria, eastern europe, & middle east +43 2236 8092 0 belgium +32 (2) 715.89.70 brazil and south america 55 (11) 3741-8360 canada 1 (800) 661-5625 denmark +45 (44) 850 700 finland +358 (9) 4783 400 france & north africa +33 1 69 86 81 81 germany +49 (221) 94 77 400 hong kong (852) 2585-6688 india (91) 80-2275577 italy +39 (2) 25086 501 japan (sony/tektronix corporation) 81 (3) 3448-3111 mexico, central america, & caribbean 52 (5) 666-6333 the netherlands +31 23 56 95555 norway +47 22 07 07 00 peoples republic of china 86 (10) 6235 1230 republic of korea 82 (2) 528-5299 south africa (2711) 651-5222 spain & portugal +34 (1) 372 6000 sweden +46 (8) 629 6503 switzerland +41 (41) 729 36 40 taiwan 886 (2) 722-9622 united kingdom & eire +44 (0) 1628 403400 usa 1 (800) 426-2200 combo sel gdv.2for pdf 4/1/98 3:37 pm page 16