If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
Power entry modules without line filter www.schurter.com/pg05 IEC Appliance Inlet C14 with Fuseholder 2-pole, Line Switch 1- or 2-pole KM Plug removal necessary for fuse replacement KM with shield C14 70 C Description -PanelMount: Snap-inversionfromfrontside -3Functions: ApplianceInletProtectionclassI,LineSwitch2-pole,Fuseholderfor fuse-links5x20mm1-or2-pole -Quickconnectterminals4.8x0.8mm -Alternative:versionwithlinefilterKMF -Alternative:versionforscrewmountingDD11 -Withcoveronrear-side -Ultra-compactdesign.Smalldimensionsinfrontofandbehindthepanel -Allsingleelementsarealreadywired -Foraddedsafety"Extra-Safe"fusedrawersareavailable FusedrawermeetsrequirementsofmedicalstandardIEC/EN60601-1 Thefusedrawercanonlybeopenedwiththeaidofatool Thefuseholderisaccessiblefromtheequipmentfront -Idealforapplicationwithhightransientloads -QualifiedforuseinequipmentaccordingIEC/EN60950 Characteristics Approvals Other versions on request -VDELicenseNumber:40021981 -ULLicenseNumber:E93617 -Fusedrawer1-pole,plussparefusecase -Fusedrawer2-pole,withshortingbar -Lineswitch1-pole -Otherrockermarking -ProtectionclassII,70C References Weblinks GeneralProductInformation Approvals,RoHS,CHINA-RoHS,MatingConnectors,e-Store, Distributor-Stock-Check,Accessories Technical Data RatingsIEC RatingsUL/CSA DielectricStrength 10A/250VAC;50Hz 10A/250VAC;60Hz >2.5kVACbetweenL-N >3kVACbetweenL/N-PE (1min/50Hz) -25Cto70C fromfrontsideIP40acc.toIEC60529 Suitableforapplianceswithprotection class1acc.toIEC61140 Quickconnectterminals4.8x0.8mm ,tin-plated Snap-in:1/1.5/2/2.5mm (allstepswithonevariant) Thermoplastic,black,UL94V-0 ApplianceInlet C14acc.toIEC/EN60320-1, UL498,CSAC22.2no.42(forcold conditions)pin-temperature70C,10A, ProtectionClass1 1or2pole,ShocksafecategoryPC2 acc.toIEC60127-6, forfuse-links5x20mm 5x20:2W(1pole)/1.4W(2-pole)per pole Choosefuse-linksfor2-poleversion insuchawaythatthetypicalpower acceptanceislessthan1.4Wforeach pole Admissiblepoweracceptanceathigherambienttemperatureseederating curves Rockerswitch2-pole,non-illuminated, acc.toIEC61058-1 Technicaldetails Fuseholder AllowableOperationTemp. DegreeofProtection ProtectionClass Terminal PanelThicknesss Material:Housing RatedPowerAcceptance@ Ta23C PowerAcceptance@Ta> 23C LineSwitch Connectors KM www.schurter.com/pg05 Dimensions KM without shield 50mm Power entry modules without line filter 30.35 25.7 .5 R1 0 46.8 50 L' N' 47 -0.05 +0.10 10.7 S 0.05 3.2 26.15 2.5 27.8 PE' m ax .R 30.5 KM with shield 30.4 25.7 R1 .5 0 47.5 50 L' 47.8 -0.05 +0.10 N' 10.7 S 0.05 10 26.2 2.5 28.5 PE' m ax .R 30.5 28.8 -0.05 Diagrams with shield 1) Line 2) Load Connectors 0. +0.10 3 0. 28 -0.05 3 +0.10 Power entry modules without line filter www.schurter.com/pg05 KM 2-pole Admissible power acceptance in Watt per pole 1.4 1.2 1.0 0.8 0.6 0.4 0.2 0.0 0 20 40 60 80 100 I = 1.0 In I = 0.7 In I = << In Derating Curves 1-pole Admissible power acceptance in Watt 2.0 1.5 I = 1.0 In 1.0 I = 0.7 In I = << In 0.5 0.0 0 20 40 60 80 100 Ambient air temperature Ta C Ambient air temperature Ta C Variants Fusedrawermustbeorderedseparately(seeaccessories). FingergripandExtraSafe.ThesamedrawerasusedbytypeKEA. Fuseholder 1-pole 2-pole 1-pole 2-pole Line Switch 2-pole 2-pole 2-pole 2-pole EMC-Shielding With EMC-shield and without line filter With EMC-shield and without line filter Order Number KM00.1205.11 KM00.1105.11 KM01.1205.11 KM01.1105.11 Packaging unit Required Accessory 50Pcs Description Fusedrawer 2 Fusedrawer with and without Voltage Selector Insert Fingergrip, 2-pole Extra-Safe, 2-pole Fingergrip, 1-pole Extra-Safe, 1-pole 4301.1401 4301.1403 4301.1405 4301.1407 ... Accessories Assorted Covers Rear Cover 0859.0076 Cord retaining kits Cord retaining strain relief Flat head, A 4700.0001 Connectors KM www.schurter.com/pg05 Mating Outlets/Connectors Category / Description Power entry modules without line filter Appliance Outlet Overview complete IEC Appliance Outlet F, Screw-on Mounting, Front Side, Solder or Quick-connect Terminal IEC Appliance Outlet F, Snap-in Mounting, Front Side, Solder or Quick-connect Terminal IEC Appliance Outlet F or H, Screw-on Mounting, Front Side, Solder, PCB or Quick-connect Terminal IEC Appliance Outlet F or H, Screw-on Mounting, Front Side, Solder or Quick-connect Terminal Appliance Outlet further types to KM Connector Overview complete IEC Connector C15, Rewireable, Straight IEC Connector C15A, Rewireable, Straight IEC Connector C15A, Rewireable, Straight IEC Connector C15A, Rewireable, Angled IEC Connector C13, Rewireable, Angled Connector further types to KM Power Cord Overview complete Power Cord with IEC Connector C13, Angled Power Cord with IEC Connector C13, Angled Power Cord with IEC Connector C13, Angled Power Cord with IEC Connector C13, Angled Power Cord with IEC Connector C13 Power Cord further types to KM 0311 3011 3012 3013 3020 ... 0101 0102 0102-G 0112 4012 ... 4787 4788 5091 5092 Thespecifications,descriptionsandillustrationsindicatedinthisdocumentarebasedon Connectors currentinformation.Allcontentissubjecttomodificationsandamendments. |
Price & Availability of KM01110511 |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |