TX-SAW/433 s-Z Instruction Manual TX-SAW / 433 s-Z Transmitter SAW Transmitter module with external antenna, for utilisations with ON-OFF modulation of a RF carrier with digital data. Pin-out Lot (Week/Year) Code www..com 1 15 Connections Pin 1-4-13 Pin 2 Pin 3 Pin 11 Pin 15 Ground Input Mod. Input Mod. RF output +V GND Connections. To be externally connected to a single ground plate. (see fig. 3) TTL 0/5V type data input with a minimum 5K resistance. Connection utilized only if the supply to pin 15 is +12V 10% (see fig. 2) TTL 0/5V type data input with a minimum 5K resistance. Connection utilized only if the supply to pin 15 is +5V 10% (see fig. 2) RF output with a characteristic impedence of 50 Connection to the positive pole of the +5V 10% supply Max voltage values allowed Description Voltage supply (Vs) to pin 15 Max 13,5 Unity V Remarks Technical features [ETS 300 200] Description Working frequency centre Voltage supply (Vs) Absorbed current RF output power (E.R.P.) Output impedance pin 11 RF spurious emissions Modulation frequency Input high logic level Input low logic level Working temperature Working temperature [ETS 300 200] Dimensions Min 433.82 4.5 Typical 433.92 5 4 50 -50 4.5 0 -20 -20 4 5 5.5 0.2 +80 +55 38.1 x 13.2 x 3 mm Max 434.02 5.5 +10 Unity MHz V mA dBm dBm kHz V V C C Remarks See notes 1 and 2 See note 1 See note 1 See fig. 5 See fig. 5 See Pin-out Note1: Values have been obtained by applying the test system shown in Fig. 1 and maximum 5,5 V power supply. Note2: The minimum and maximum showed values are determined by the device's construction tolerance. To define the working frequency of the device, add to these values the deviation caused by the thermal variations (see fig. 3). Note3: To keep the parameters within the limits established by the rules in force, (see para. "Reference Rules"), it is recommended to supply the circuit with not more than 5,5V and to comply with all the recommendations specified in para "Device usage". Messrs AUREL declines all responsibilities in case the a.m. recommendations are disregarded. Technical features are subject to change without notice. AUREL S.p.A does not feel responsible for any damage caused by the device's misuse. AUREL S.p.A. Via Foro dei Tigli, 4 - 47015 Modigliana (FC) - ITALY Tel.: +390546941124 - Fax: +390546941660 http://www.aurel.it - email: aurel@aurel.it Rev. A, 19-09-2001 Pag 1 of 5 TX-SAW/433 s-Z The declared technical features have been obtained by applying the following testing system: Instruction Manual Fig. 1 +5V DC Power Supplier Square wave generator : 4 KHz frequency Out Level 0/ 5V / Pin 3 Spectrum analyzer RF 50 Input TX-SAW/433 s-Z www..com Pin 11 50 U coaxial cable connection Device usage In order to obtain the performances described in the technical specifications and to comply with the operating conditions, which characterize the Certification, the transmitter has to be mounted on a printed circuit, and keep into consideration what follows: 5V dc supply 1. The transmitter must be supplied by a very low voltage source, safely protected against short circuits. 2. Maximum voltage variations allowed: 0,5 V. 3. De-coupling, next to the transmitter, by means of a minimum 100.000 pF ceramic capacitor. Ground 1. It must surround at the best the welding area of the transmitter. The circuit must be double layer, with throughout vias to the ground planes, approximately each 15 mm. 2. It must be properly dimensioned, especially in the antenna connection area, in case a radiating whip antenna is fitted in it (an area of approximately 50 mm radius is suggested). Technical features are subject to change without notice. AUREL S.p.A does not feel responsible for any damage caused by the device's misuse. AUREL S.p.A. Via Foro dei Tigli, 4 - 47015 Modigliana (FC) - ITALY Tel.: +390546941124 - Fax: +390546941660 http://www.aurel.it - email: aurel@aurel.it Rev. A, 19-09-2001 Pag 2 di 5 TX-SAW/433 s-Z Fig. 2 Instruction Manual www..com 50 Ohm line 1. It must be the shortest as possible. 2. 1,8 mm wide for 1 mm thick FR4 printed circuits and 2,9 mm wide for 1,6 mm thick FR4 printed circuits. It must be kept 2 mm away from the ground circuit on the same side. 3. On the opposite side a ground circuit area must be present. Antenna connection 1. It may be utilized as the direct connection point for the radiating whip antenna. 2. It can bear the connection of the central wire of a 50 coaxial cable. Be sure that the braid is welded to the ground in a close point. Antenna 1. A whip antenna, 16,5 mm long and approximately 1 mm dia, brass or copper wire made, must be connected to the RF output of the transmitter (pin 11), (see fig. 2). 2. The antenna body must be keep straight as much as possible and it must be free from other circuits or metal parts (5 cm minimum suggested distance.) 3. It can be utilized either vertically or horizontally, provided that a good ground plane surrounds the connection point between antenna and transmitter output. N.B: As an alternative to the a.m. antenna it is possible to fit the whip model manufactured by AUREL (see related Data Sheet and Application Notes). By fitting whips too different from the described ones, the EEC Certification is not assured. Other components 1. Keep the transmitter separate from all other components of the circuit (more than 5 mm). Technical features are subject to change without notice. AUREL S.p.A does not feel responsible for any damage caused by the device's misuse. AUREL S.p.A. Via Foro dei Tigli, 4 - 47015 Modigliana (FC) - ITALY Tel.: +390546941124 - Fax: +390546941660 http://www.aurel.it - email: aurel@aurel.it Rev. A, 19-09-2001 Pag 3 di 5 Instruction Manual 2. Keep particularly far away and shielded all microprocessors and their clock circuits. 3. Do not fit components around the 50 Ohm line. Keep them at least at 5 mm distance. 4. If the Antenna Connection is directly used for a radiating whip connection, keep at least 5 cm radius free area. In case a 50 impedance coaxial cable is connected, then 5 mm radius will suffice. TX-SAW/433 s-Z Reference Rules The TX-SAW/433 s-Z transmitter complies with the EU Rules ETS 300-220, with a 5,5V max. supply. The equipment has been tested according to rule EN 60950 and it can be utilized inside a special insulated housing that assures its compliance with the above mentioned rule. The transmitter must be supplied by a www..com voltage source, safely protected against short circuits. very low The use of the transmitter module is foreseen inside housings that assure the overcoming of the rules EN 61000 not directly applicable to the module itself. In particular, it is left at the User's care, the insulation of the external antenna connection, and of the antenna itself, since the RF output of the transmitter is not built to directly bear the electrostatic charges foreseen by the EN 61000-4-2 rules. CEPT 70-03 Recommendation In order to comply with such rule, the device must be used only for a 10% of an hourly duty-cycle, (that means 6 minutes of utilisation over 60). The device utilisation inside the italian territory is governed by the Codice Postale and Telecomunicazioni rules in force (art. no. 334 and subsequents). BTX-SAW/433 s-Z module was previously BZT approved by mean of Test Report obtained c/o the laboratory: SENTON GmbH - Aussere Fruhlingstrasse 45 D - 94315 STRAUBIN Technical features are subject to change without notice. AUREL S.p.A does not feel responsible for any damage caused by the device's misuse. AUREL S.p.A. Via Foro dei Tigli, 4 - 47015 Modigliana (FC) - ITALY Tel.: +390546941124 - Fax: +390546941660 http://www.aurel.it - email: aurel@aurel.it Rev. A, 19-09-2001 Pag 4 di 5 TX-SAW/433 s-Z Reference curves Instruction Manual Fig.3 Temperature - Frequency delta 100 80 60 40 20 0 -20 -40 -60 -80 -100 -20 -10 0 10 Delta F [KHz] www..com F0=433.92 100KHz 20 30 40 50 60 70 80 Temperature [C] The curve has been obtained by the testing system shown in Fig.1. 5V Power supply Fig.4 Temperature - Output power delta Output power delta [dB] 2 1 0 -1 -2 -20 -10 0 10 20 30 40 50 60 70 80 Temperature [C] The curve has been obtained by the testing system shown in Fig.1 5V supply, RF output 433,92MHz, 100 kHz, output power 8dBm 2dB Technical features are subject to change without notice. AUREL S.p.A does not feel responsible for any damage caused by the device's misuse. AUREL S.p.A. Via Foro dei Tigli, 4 - 47015 Modigliana (FC) - ITALY Tel.: +390546941124 - Fax: +390546941660 http://www.aurel.it - email: aurel@aurel.it Rev. A, 19-09-2001 Pag 5 di 5 |
Price & Availability of TX-SAWE433 |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |