![]() |
|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
Data Sheet March 27, 2008 QBW018A0B1-TZ DC-DC Converter Power Modules: 36-75Vdc Input; 12Vdc Output; 18A Output Current RoHS Compliant Features Compliant to RoHS EU Directive 2002/95/EC Compatible in a Pb-free or SnPb reflow environment High power density: 155 W/in3 Delivers up to 18A Output current High efficiency - 93% at 12V full load Low output ripple and noise Industry standard Quarter brick: 57.9 mm x 36.8 mm x 10.6 mm (2.28 in x 1.45 in x 0.42 in) 2:1 input voltage range Constant Switching frequency Positive Remote On/Off logic Output overcurrent/voltage protection Over temperature protection Wide operating temperature range (-40C to 85C) Meets the voltage insulation requirements for ETSI 300-132-2 and complies with and is Licensed for Basic Insulation rating per EN 60950-1. CE mark meets 73/23/EEC and 93/68/EEC directives UL* 60950-1Recognized, CSA C22.2 No. 60950-103 Certified, and VDE 0805:2001-12 (EN60950-1) Licensed ISO** 9001 and ISO 14001 certified manufacturing facilities Applications ATCA Front Board / Blade Distributed power architectures Servers and storage applications Optical and Access Network Equipment Enterprise Networks Options Negative Remote On/Off logic Base plate Option (-H) Auto restart after fault shutdown Case ground pin Description The QBW018A0B-TZ series of modules are similar to the QBW018A0B series (consult the QBW018A0B Series data sheet) with the following exceptions: The output can accommodate a maximum external capacitance of 10,000 F (1000uF minimum with 30mA pre-load) to provide power to VRMs requiring high capacitance. The module can withstand a 100V /1 ms input voltage transient. The Turn-on Delay and Rise times have been slowed down to accommodate the large external capacitance capability (see Fig 4). Enhanced EMI filtering. Active load sharing (Parallel Operation) option is not available. * UL is a registered trademark of Underwriters Laboratories, Inc. CSA is a registered trademark of Canadian Standards Association. VDE is a trademark of Verband Deutscher Elektrotechniker e.V. ** ISO is a registered trademark of the International Organization of Standards Document No: DS06-001 ver. 1.34 PDF name: QBW018A0B1-TZ_ds.pdf Data Sheet March 27, 2008 QBW018A0B1-TZ Series Power Modules; DC-DC converters 36-75Vdc Input; 12Vdc Output; 18A Output Current Absolute Maximum Ratings Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute stress ratings only, functional operation of the device is not implied at these or any other conditions in excess of those given in the operations sections of the data sheet. Exposure to absolute maximum ratings for extended periods can adversely affect the device reliability. Parameter Input Voltage* Continuous Transient (Pulse duration above 75Vdc = 1ms) Non-operating continuous Operating Ambient Temperature (see Thermal Considerations section) Storage Temperature I/O Isolation Voltage (100% factory Hi-Pot tested) All All Tstg -55 125 1500 C Vdc All VIN VIN, trans VIN TA -0.3 75 -0.3 -40 75 100 80 85 Vdc Vdc Vdc C Device Symbol Min Max Unit * Input over voltage protection will shut down the output voltage when the input voltage exceeds the maximum threshold or transient pulse duration levels. Electrical Specifications Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions. Parameter Operating Input Voltage Maximum Input Current (VIN=0V to 75V, IO=IO, max) Inrush Transient Input Reflected Ripple Current, peak-to-peak (5Hz to 20MHz, 12H source impedance; VIN=0V to 75V, IO= IOmax ; see Figure 9) Input Ripple Rejection (120Hz) All All All It 2 Device Symbol VIN IIN,max Min 36 Typ 48 Max 75 7 Unit Vdc Adc 20 50 1 As mAp-p dB 2 CAUTION: This power module is not internally fused. An input line fuse must always be used. This power module can be used in a wide variety of applications, ranging from simple standalone operation to being part of complex power architecture. To preserve maximum flexibility, internal fusing is not included; however, to achieve maximum safety and system protection, always use an input line fuse. The safety agencies require a fastacting fuse with a maximum rating of 15A (see Safety Considerations section). Based on the information provided in this data sheet on inrush energy and maximum dc input current, the same type of fuse with a lower rating can be used. Refer to the fuse manufacturer's data sheet for further information. LINEAGE POWER 2 Data Sheet March 27, 2008 QBW018A0B1-TZ Series Power Modules; DC-DC converters 36-75Vdc Input; 12Vdc Output; 18A Output Current Electrical Specifications (continued) Parameter Output Voltage Set-point (VIN=VIN,nom, IO=IO, max, TA=25C) Output Voltage (Over all operating input voltage, resistive load, and temperature conditions until end of life) Output Regulation Line (VIN=VIN, min to VIN, max) Load (IO=IO, min to IO, max) Temperature (TA= -40C to 85C) Output Ripple and Noise on nominal output (VIN=VIN, nom IO= IO, min to IO, max) RMS (5Hz to 20MHz bandwidth) Peak-to-Peak (5Hz to 20MHz bandwidth) External Capacitance (see Note 1 below) Output Current (see Note 1 below) Output Current Limit Inception Efficiency VIN=VIN, nom, TA=25C IO=IO, max, VO= VO, set Switching Frequency Dynamic Load Response (Io/t=0.1A/s, VIN=VIN, nom, TA=25C; Tested with a 10 F aluminium and a 1.0 F tantalum capacitor across the load) Load Change from Io= 50% to 75% of Io,max: Peak Deviation Settling Time (Vo<10% peak deviation) Load Change from Io= 75% to 50% of Io,max: Peak Deviation Settling Time (Vo<10% peak deviation) B Vpk ts 4 % VO, set s B Vpk ts 4 % VO, set s fsw 300 kHz B 93.0 % All All All All B CO, ext Io IO, lim 1000* 0.030* 20 25 70 10,000 18 mVrms mVpk-pk F Adc Adc All All All VO 11.4 12.6 Vdc Device B Symbol VO, set Min Typ 12 Max Unit Vdc 0.2 3 150 % VO, set % VO, set mV * Note 1 : For proper startup under very light load conditions, either of the following combinations of minimum output load and output capacitance must be satisfied: * * For Co, ext (min) = 10uF, Io(min) >/= 0.5A For Io(min) = 30mA, Co, ext >/= 1000 F Isolation Specifications Parameter Isolation Capacitance Isolation Resistance Symbol Ciso Riso Min 10 Typ 2000 Max Unit pF M LINEAGE POWER 3 Data Sheet March 27, 2008 QBW018A0B1-TZ Series Power Modules; DC-DC converters 36-75Vdc Input; 12Vdc Output; 18A Output Current General Specifications Parameter Calculated MTBF (VIN=48V, IO=80% of IO, max, TA=25C, airflow=1m/s(200LFM)) Weight Device B Min Typ 3088170 44 (1.55) Max Unit Hours g (oz.) Feature Specifications Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions. See Feature Descriptions for additional information. Parameter Remote On/Off Signal Interface (VIN=VIN, min to VIN, max , Signal referenced to VINterminal) Negative Logic: Device code suffix "1" Logic Low = module On, Logic High = module Off Positive Logic: No device code suffix required Logic Low = module Off, Logic High = module On On/Off Thresholds: Remote On/Off Current - Logic Low Logic Low Voltage Logic High Voltage - (Typ = Open Collector) Logic High maximum allowable leakage current (Von/off = 2.0V) Maximum voltage allowed on On/Off pin Turn-On Delay and Rise Times (IO=IO, max) Tdelay = Time until VO=10% of VO, set from either application of VIN with Remote On/Off set to On or operation of Remote On/Off from Off to On with VIN applied for at least 1 second T rise = time for VO to rise from 10% of VO, set to 90% of VO, set. Output Overvoltage Protection Over temperature Protection (See Feature Descriptions) Input Undervoltage Lockout Turn-on Threshold Turn-off Threshold VuVLO 32 35 34 36 V V All All All Tref All Tdelay enable With Vin Device Symbol Min Typ Max Unit All All All All All Ion/off Von/off Von/off Ion/off Von/off 5 0.0 2.0 10 15 0.8 5.0 6.0 14.0 A V V A V 13 30 15 45 125 15 ms ms ms V 0 Tdelay enable With On/Off Trise C LINEAGE POWER 4 Data Sheet March 27, 2008 QBW018A0B1-TZ Series Power Modules; DC-DC converters 36-75Vdc Input; 12Vdc Output; 18A Output Current Characteristic Curves The following figures provide typical characteristics for the QBW018A0B-TZ (12V, 18A) at 25C. The figures are identical for either positive or negative Remote On/Off logic. 6 OUTPUT VOLTAGE Io=0A 45 50 55 60 65 70 75 7 INPUT CURRENT, Ii (A) 5 4 3 2 Io=9A 1 0 30 35 40 Io=18A INPUT VOLTAGE, VO (V) On/Off VOLTAGE VON/OFF(V) (2V/div) VO (V) (5V/div) TIME, t (10 ms/div) Figure 1. Typical Input Characteristic at Room Temperature. 95 Figure 4. Typical Start-Up Using Remote On/Off, negative logic version shown. OUTPUT VOLTAGE OUTPUT CURRENT 20 90 Vin=36V Vin=48V Vin=75V EFFICIENCY (%) 85 80 70 0 5 10 15 IO (A) (5A/div) 75 VO (V) (500mV/div) OUTPUT CURRENT, Io (A) TIME, t (200 s/div) Figure 2. Typical Converter Efficiency Vs. Output current at Room Temperature. Figure 5. Typical Transient Response to Step change in Load from 25% to 50% to 25% of Full Load at Room Temperature and 48 Vdc Input. OUTPUT CURRENT OUTPUT VOLTAGE VO (V) (500mV/div) IO (A) (5A/div) OUTPUT VOLTAGE, VO (V) (50mV/div) TIME, t (2s/div) TIME, t (200 s/div) Figure 3. Typical Output Ripple and Noise at Room temperature and IO= IO, max. Figure 6. Typical Transient Response to Step Change in Load from 50% to 75% to 50% of Full Load at Room Temperature and 48 Vdc Input. LINEAGE POWER 5 Data Sheet March 27, 2008 QBW018A0B1-TZ Series Power Modules; DC-DC converters 36-75Vdc Input; 12Vdc Output; 18A Output Current Characteristic Curves (continued) 12.3 OUTPUT VOLTAGE, VO (V) 12.2 Io=0A 12.1 12 Io=9A Io=18A 11.9 35 40 45 50 55 60 65 70 75 INPUT VOLTAGE, Vin (V) Figure 7. Typical Output voltage regulation vs. Input voltage at Room Temperature. 12.3 Vin=48V OUTPUT VOLTAGE, VO (V) 12.2 12.1 12 Vin=75V 11.9 Vin=36V 11.8 0 5 10 15 20 OUTPUT CURRENT, IO (A) Figure 8. Typical Output voltage regulation Vs. Output current at Room Temperature. LINEAGE POWER 6 Data Sheet March 27, 2008 QBW018A0B1-TZ Series Power Modules; DC-DC converters 36-75Vdc Input; 12Vdc Output; 18A Output Current Test Configurations Design Considerations Input Source Impedance The power module should be connected to a low ac-impedance source. A highly inductive source impedance can affect the stability of the power module. For the test configuration in Figure 9, a 100F electrolytic capacitor (ESR<0.7 at 100kHz), mounted close to the power module helps ensure the stability of the unit. Consult the factory for further application guidelines. Note: Measure input reflected-ripple current with a simulated source inductance (LTEST) of 12 H. Capacitor CS offsets possible battery impedance. Measure current as shown above. Safety Considerations For safety-agency approval of the system in which the power module is used, the power module must be installed in compliance with the spacing and separation requirements of the end-use safety agency standard, i.e., UL 60950-1-3, CSA C22.2 No. 6095000, and VDE 0805:2001-12 (IEC60950-1). If the input source is non-SELV (ELV or a hazardous voltage greater than 60 Vdc and less than or equal to 75Vdc), for the module's output to be considered as meeting the requirements for safety extra-low voltage (SELV), all of the following must be true: The input source is to be provided with reinforced insulation from any other hazardous voltages, including the ac mains. One VIN pin and one VOUT pin are to be grounded, or both the input and output pins are to be kept floating. Figure 9. Input Reflected Ripple Current Test Setup. Note: Use a 1.0 F ceramic capacitor and a 10 F aluminum or tantalum capacitor. Scope measurement should be made using a BNC socket. Position the load between 51 mm and 76 mm (2 in. and 3 in.) from the module. The input pins of the module are not operator accessible. Another SELV reliability test is conducted on the whole system (combination of supply source and subject module), as required by the safety agencies, to verify that under a single fault, hazardous voltages do not appear at the module's output. Note: Do not ground either of the input pins of the module without grounding one of the output pins. This may allow a non-SELV voltage to appear between the output pins and ground. The power module has extra-low voltage (ELV) outputs when all inputs are ELV. The input to these units is to be provided with a maximum 15A fast-acting (or time-delay) fuse in the ungrounded lead. Figure 10. Output Ripple and Noise Test Setup. CONT ACT AND DISTRIBUTION LOSSES VI(+) II SUPPL Y VI(-) CONT ACT RESIST ANCE VO2 VO1 IO LOAD Note: All measurements are taken at the module terminals. When socketing, place Kelvin connections at module terminals to avoid measurement errors due to socket contact resistance. Figure 11. Output Voltage and Efficiency Test Setup. LINEAGE POWER 7 Data Sheet March 27, 2008 QBW018A0B1-TZ Series Power Modules; DC-DC converters 36-75Vdc Input; 12Vdc Output; 18A Output Current Output Over Voltage clamp The output overvoltage clamp consists of a control circuit, independent of the primary regulation loop, that monitors the voltage on the output terminals and clamps the voltage when it exceeds the overvoltage set point. The control loop of the clamp has a higher voltage set point than the primary loop. This provides a redundant voltage control that reduces the risk of output overvoltage. The module can be restarted by cycling the dc input power for at least one second or by toggling the remote on/off signal for at least one second. Feature Description Overcurrent Protection To provide protection in a fault output overload condition, the module is equipped with internal current-limiting circuitry and can endure current limit for few mili-seconds. If overcurrent persists beyond a few milliseconds, the module will shut down and remain latched off. The overcurrent latch is reset by either cycling the input power or by toggling the on/off pin for one second. If the output overload condition still exists when the module restarts, it will shut down again. This operation will continue indefinitely until the overcurrent condition is corrected. An auto-restart option is also available. An autorestart feature continually attempts to restore the operation until fault condition is cleared. Over Temperature Protection These modules feature an overtemperature protection circuit to safeguard against thermal damage. The circuit shuts down and latches off the module when the maximum device reference temperature is exceeded. The module can be restarted by cycling the dc input power for at least one second or by toggling the remote on/off signal for at least one second. Remote On/Off Two remote on/off options are available. Positive logic remote on/off turns the module on during a logic-high voltage on the ON/OFF pin, and off during a logic low. Negative logic remote on/off turns the module off during a logic high and on during a logic low. Negative logic, device code suffix "1," is the factory-preferred configuration. The on/off circuit is powered from an internal bias supply. To turn the power module on and off, the user must supply a switch to control the voltage between the on/off terminal and the Vi (-) terminal (Von/off). The switch can be an open collector or equivalent (see Figure 12). A logic low is Von/off = 0.0V to 0.8V. The typical Ion/off during a logic low is 10 A. The switch should maintain a logiclow voltage while sinking 10A. During a logic high, the maximum Von/off generated by the power module is 5.0V. The maximum allowable leakage current of the switch at Von/off = 2.0V is 6.0A. If using an external voltage source, the maximum voltage V on/off on the pin is 14.0V with respect to the Vi (-) terminal. If not using the remote on/off feature, perform one of the following to turn the unit on: For negative logic, short ON/OFF pin to VI(-). For positive logic: leave ON/OFF pin open. Ion/off + Von/off - VO(+) LOAD VI(+) VI(-) VO(-) ON/OFF Input Under/Over Voltage Lockout At input voltages above or below the input under/over voltage lockout limits, module operation is disabled. The module will begin to operate when the input voltage level changes to within the under and overvoltage lockout limits. Figure 12. Remote On/Off Implementation. LINEAGE POWER 8 Data Sheet March 27, 2008 QBW018A0B1-TZ Series Power Modules; DC-DC converters 36-75Vdc Input; 12Vdc Output; 18A Output Current Thermal Considerations The power modules operate in a variety of thermal environments; however, sufficient cooling should be provided to help ensure reliable operation. Considerations include ambient temperature, airflow, module power dissipation, and the need for increased reliability. A reduction in the operating temperature of the module will result in an increase in reliability. The thermal data presented here is based on physical measurements taken in a wind tunnel. Heat-dissipating components are mounted on the top side of the module. Heat is removed by conduction, convection and radiation to the surrounding environment. Proper cooling can be verified by measuring the thermal reference temperatures (TH1 and TH2). Peak temperatures (TH) occurs at the positions indicated in Figure 13. For reliable operation these temperatures should not exceed the listed temperature threshold. TH2 TH1 (14-16) show the maximum output current that can be delivered by each module in the respective orientation without exceeding the maximum TH temperatures versus local ambient temperature (TA) for air flows of 1 m/s (200 ft./min.), 2m/s (400 ft./min.) and 3m/s (600 ft./min.). The use of Figures 14 - 15 are shown in the following example: OUTPUT CURRENT, IO (A) 20 15 10 3m/s (600LFM) 2m/s (400LFM) 5 1m/s (200LFM) 0 0 20 40 60 80 100 33.9 (1.33) 23.6 (.93) LOCAL AMBIENT TEMPERATURE, TA (C) Figure 14. Output Current Derating for the QBW018A0B-TZ in the Transverse Orientation with no baseplate; Airflow Direction From Vin(-) to Vin(+); Vin = 48V. 20 OUTPUT CURRENT, IO (A) 15 15.7 (.62) 38.3 (1.51) 10 3m/s (600LFM) 2m/s (400LFM) 5 1m/s (200LFM) Figure 13. Locations of the thermal reference temperature measurement points TH1 and TH2. The output power of the module should not exceed the rated power for the module as listed in the Ordering Information table. Although the maximum TH temperatures of the power modules are 110 C - 115 C, you can limit this temperature to a lower value for extremely high reliability. Please refer to the Application Note "Thermal Characterization Process For Open-Frame BoardMounted Power Modules" for a detailed discussion of thermal aspects including maximum device temperatures. 0 0 20 40 60 80 100 LOCAL AMBIENT TEMPERATURE, TA (C) Figure 15. Output Current Derating for the QBW018A0B-TZ in the Transverse Orientation with baseplate; Airflow Direction From Vin(-) to Vin(+); Vin = 48V. Heat Transfer via Convection Increased airflow over the module enhances the heat transfer via convection. The thermal derating figures LINEAGE POWER 9 Data Sheet March 27, 2008 QBW018A0B1-TZ Series Power Modules; DC-DC converters 36-75Vdc Input; 12Vdc Output; 18A Output Current OUTPUT CURRENT, IO (A) 20 Layout Considerations The QBW018 power module series are low profile in order to be used in fine pitch system card architectures. As such, component clearance between the bottom of the power module and the mounting board is limited. Avoid placing copper areas on the outer layer directly underneath the power module. Also avoid placing via interconnects underneath the power module. 80 100 15 3m/s (600LFM) 2m/s (400LFM) 10 5 1m/s (200LFM) 0 0 20 40 60 For additional layout guide-lines, refer to the PIM200X and FLT007A0 Input Filter Module data sheets. LOCAL AMBIENT TEMPERATURE, TA (C) Figure 16. Output Current Derating for QBW018A0B-TZ in the Transverse Orientation with baseplate and 0.25-inch high heatsink; Airflow Direction From Vin(-) to Vout(+); Vin = 48V OUTPUT CURRENT, IO (A) 20 Post solder Cleaning and Drying Considerations Post solder cleaning is usually the final circuit-board assembly process prior to electrical board testing. The result of inadequate cleaning and drying can affect both the reliability of a power module and the testability of the finished circuit-board assembly. For guidance on appropriate soldering, cleaning and drying procedures, refer to Lineage Power Board Mounted Power Modules: Soldering and Cleaning Application Note. 15 3m/s (600LFM) 10 2m/s (400LFM) 1m/s (200LFM) Through-Hole Lead-Free Soldering Information The RoHS-compliant through-hole products use the SAC (Sn/Ag/Cu) Pb-free solder and RoHS-compliant components. They are designed to be processed through single or dual wave soldering machines. The pins have an RoHS-compliant finish that is compatible with both Pb and Pb-free wave soldering processes. A maximum preheat rate of 3C/s is suggested. The wave preheat process should be such that the temperature of the power module board is kept below 210C. For Pb solder, the recommended pot temperature is 260C, while the Pb-free solder pot is 270C max. Not all RoHS-compliant through-hole products can be processed with paste-through-hole Pb or Pb-free reflow process. If additional information is needed, please consult with your Lineage Power representative for more details. 5 0 0 20 40 60 80 100 LOCAL AMBIENT TEMPERATURE, TA (C) Figure 17. Output Current Derating for QBW018A0BTZ in the Transverse Orientation with baseplate and 0.5-inch high heatsink; Airflow Direction From Vin(-) to Vout(+); Vin = 48V LINEAGE POWER 10 Data Sheet March 27, 2008 QBW018A0B1-TZ Series Power Modules; DC-DC converters 36-75Vdc Input; 12Vdc Output; 18A Output Current Mechanical Outline for QBW018A0B-TZ Through-Hole Module Dimensions are in millimeters and [inches]. Tolerances: x.x mm 0.5 mm [x.xx in. 0.02 in.] (Unless otherwise indicated) x.xx mm 0.25 mm [x.xxx in 0.010 in.] TOP VIEW SIDE VIEW BOTTOM VIEW - Optional pin/pin length shown in Table 2 Device Options. *Top side label includes Lineage Power name, product designation, and data code. LINEAGE POWER 11 Data Sheet March 27, 2008 QBW018A0B1-TZ Series Power Modules; DC-DC converters 36-75Vdc Input; 12Vdc Output; 18A Output Current Mechanical Outline for QBW-HTZ (Baseplate Version) Through Hole Module Dimensions are in millimeters and [inches]. Tolerances: x.x mm 0.5 mm [x.xx in. 0.02 in.] (Unless otherwise indicated) x.xx mm 0.25 mm [x.xxx in 0.010 in.] TOP VIEW SIDE VIEW BOTTOM VIEW - Optional pin/pin length shown in Table 2 Device Options. *Bottom side label includes Lineage Power name, product designation, and data code. LINEAGE POWER 12 Data Sheet March 27, 2008 QBW018A0B1-TZ Series Power Modules; DC-DC converters 36-75Vdc Input; 12Vdc Output; 18A Output Current Recommended Pad Layout for Through Hole Module Dimensions are in millimeters and (inches). Tolerances: x.x mm 0.5 mm (x.xx in. 0.02 in.) [Unless otherwise indicated] x.xx mm 0.25 mm (x.xxx in 0.010 in.) Option Feature, Pin is not present unless this option is specified. LINEAGE POWER 13 Data Sheet March 27, 2008 QBW018A0B1-TZ Series Power Modules; DC-DC converters 36-75Vdc Input; 12Vdc Output; 18A Output Current Ordering Information Please contact your Lineage Power Sales Representative for pricing, availability and optional features. Table 1. Device Code Input Voltage 48V (36-75Vdc) Output Voltage 12V Output Current 18A Efficiency 93% Connector Type Through hole Product codes QBW018A0B61-HTZ Comcodes CC109101854 Table 2. Device Options Option Negative remote on/off logic Auto-restart Pin Length: 3.68 mm 0.25mm (0.145 in. 0.010 in.) Case ground pin (offered with baseplate option only) Pin Length: 2.79 mm 0.25mm (0.110 in. 0.010 in.) Base Plate option Suffix 1 4 6 7 8 -H Note: Legacy device codes may contain a -B option suffix to indicate 100% factory Hi-Pot tested to the isolation voltage specified in the Absolute Maximum Ratings table. The 100% Hi-Pot test is now applied to all device codes, with or without the -B option suffix. Existing comcodes for devices with the -B suffix are still valid; however, no new comcodes for devices containing the -B suffix will be created. Asia-Pacific Headquarters Tel: +65 6416 4283 Europe, Middle-East and Africa Headquarters Tel: +49 89 6089 286 India Headquarters Tel: +91 80 28411633 World Wide Headquarters Lineage Power Corporation 3000 Skyline Drive, Mesquite, TX 75149, USA +1-800-526-7819 (Outside U.S.A.: +1-972-284-2626) www.lineagepower.com e-mail: techsupport1@lineagepower.com Lineage Power reserves the right to make changes to the product(s) or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. (c) 2008 Lineage Power Corporation, (Mesquite, Texas) All International Rights Reserved. Document No: DS06-001 ver. 1.34 PDF name: QBW018A0B1-TZ_ds.pdf |
Price & Availability of QBW018A0B61-HTZ
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |