XR16M581 1.62V TO 3.63V UART WITH 16-BYTE FIFO AND VLIO INTERFACE AUGUST 2009 REV. 1.0.1 GENERAL DESCRIPTION The XR16M5811 (M581) is an enhanced Universal Asynchronous Receiver and Transmitter (UART) with a VLIO bus interface and has 16 bytes of transmit and receive FIFOs, programmable transmit and receive FIFO trigger levels, automatic hardware and software flow control, and data rates of up to 20 Mbps at 3.3V, 16 Mbps at 2.5V and 10 Mbps at 1.8V with 4X data sampling rate. The Auto RS-485 Half-Duplex Direction control feature simplifies both the hardware and software for half-duplex RS-485 applications. In addition, the Multidrop mode with Auto Address detection increases the performance by simplifying the software routines. The Independent TX/RX Baud Rate Generator feature allows the transmitter and receiver to operate at different baud rates. Power consumption of the M581 can be minmized by enabling the sleep mode and PowerSave mode. The M581 has a 16550 compatible register set that provide users with operating status and control, receiver error indications, and modem serial interface controls. An internal loopback capability allows onboard diagnostics. The M581 is available in 24-pin QFN, 32-pin QFN and 25-pin BGA packages. NOTE: 1 Covered by U.S. Patent #5,649,122. FEATURES * VLIO bus interface * Pin-to-pin compatible with SC16C850V and SC16C850SV in 32-QFN package * 20 Mbps maximum data rate * Programmable TX/RX FIFO Trigger Levels * TX/RX FIFO Level Counters * Independent TX/RX Baud Rate Generator * Fractional Baud Rate Generator * Auto RTS/CTS Hardware Flow Control * Auto XON/XOFF Software Flow Control * Auto RS-485 Half-Duplex Direction Control * Multidrop mode w/ Auto Address Detect * Sleep Mode with Automatic Wake-up * PowerSave mode * Infrared (IrDA 1.0 and 1.1) mode * 1.62V to 3.63V supply operation * Crystal oscillator or external clock input APPLICATIONS * Personal Digital Assistants (PDA) * Cellular Phones/Data Devices * Battery-Operated Devices * Global Positioning System (GPS) * Bluetooth FIGURE 1. XR16M581 BLOCK DIAGRAM VCC (1.62 to 3.63 V) TX BRG UART G ND 16 Byte TX FIFO TX & IR ENDEC RX 16 Byte RX FIFO TX, RX, RTS#, CTS#, DTR#, DSR#, RI#, CD# Pw rSave LLA# AD7:AD0 IOR# IOW # CS# INT RESET# VLIO Bus Interface Regs RX BRG Crystal Osc/Buffer XTAL1 XTAL2 Exar Corporation 48720 Kato Road, Fremont CA, 94538 * (510) 668-7000 * FAX (510) 668-7017 * www.exar.com XR16M581 1.62V TO 3.63V UART WITH 16-BYTE FIFO AND VLIO INTERFACE FIGURE 2. PIN OUT ASSIGNMENT REV. 1.0.1 RESET# CTS# RESET# DTR# RTS# INT CTS# RTS# LLA# INT NC 18 17 16 15 14 13 VCC 19 12 AD0 20 11 AD1 21 AD2 22 AD3 23 AD4 24 1 AD5 2 AD6 3 AD7 4 RX 5 TX 24-pin QFN 10 9 8 7 6 CS# 24 23 22 21 20 19 18 17 IOR# GND IOW# XTAL2 XTAL1 PWRSAVE LLA# NC NC 16 15 14 13 12 11 10 9 CS NC NC IOR# GND IOW# XTAL2 XTAL1 PWRSAVE DSR# CD# RI# VCC AD0 AD1 AD2 AD3 25 26 27 28 29 30 31 32 AD4 32-pin QFN 12345678 NC AD5 AD6 AD7 RX TX A1 Corner 12 A B C D E Transparent Top View CTS# VCC AD0 AD3 AD4 RESET# AD5 AD7 AD1 AD2 RTS# DTR# RX CS# AD6 LLA# INT DSR# PWRSAVE TX IOR# GND XTAL2 XTAL1 IOW# 34 5 ORDERING INFORMATION PART NUMBER XR16M581IL24 XR16M581IL32 XR16M581IB25 PACKAGE 24-Pin QFN 32-Pin QFN 25-Pin BGA OPERATING TEMPERATURE RANGE -40C to +85C -40C to +85C -40C to +85C DEVICE STATUS Active Active Active 2 XR16M581 REV. 1.0.1 1.62V TO 3.63V UART WITH 16-BYTE FIFO AND VLIO INTERFACE PIN DESCRIPTIONS Pin Description NAME 24-QFN PIN# 32-QFN PIN# 25-BGA PIN# TYPE DESCRIPTION DATA BUS INTERFACE AD0 AD1 AD2 AD3 AD4 AD5 AD6 AD7 IOR# 20 21 22 23 24 1 2 3 12 29 30 31 32 1 3 4 5 14 C1 D2 E2 D1 E1 B2 E3 C2 A5 I/O Multiplexed Address/Data lines [7:0]. The register address is latched on the rising edge of the LLA#. After the LLA# signal goes high, the UART enters the data phase where the data is placed on these lines. I Read strobe (active low). The falling edge instigates an internal read cycle and retrieves the data byte from an internal register pointed by the latched address. The UART places the data byte on the data bus to allow the host processor to read it on the rising edge. Write strobe (active low). The falling edge instigates the internal write cycle and the rising edge transfers the data byte on the data bus to an internal register pointed by the latched address. Chip select (active low). The falling edge starts the access to the UART. A read or write is determined by the IOR# and IOW# signals. Latch Lower Address (active low). The register address is latched on the rising edge of the LLA# signal. After the LLA# goes high, the device enters the data phase where the data is placed on the AD[7:0] lines. Interrupt output (active high). The output state is defined by the user through the software setting of MCR[3]. INT is set to the active mode when MCR[3] is set to a logic 1. INT is set to the three state mode when MCR[3] is set to a logic 0. See MCR[3]. IOW# 10 12 E5 I CS# 6 8 D3 I LLA# 14 19 A4 I INT 15 20 B4 O MODEM OR SERIAL I/O INTERFACE TX 5 7 E4 O UART Transmit Data or infrared encoder data. Standard transmit and receive interface is enabled when MCR[6] = 0. In this mode, the TX signal will be a logic 1 during reset or idle (no data). Infrared IrDA transmit and receive interface is enabled when MCR[6] = 1. In the Infrared mode, the inactive state (no data) for the Infrared encoder/decoder interface is a logic 0. If it is not used, leave it unconnected. UART Receive Data or infrared receive data. Normal receive data input must idle at logic 1 condition. The infrared receiver idles at logic 0. This input should be connected to VCC when not used. UART Request-to-Send (active low) or general purpose output. This output must be asserted prior to using auto RTS flow control, see EFR[6], MCR[1] and IER[6]. This pin can also be used as the Auto RS-485 Half-duplex Direction control output, see FCTR[3] and EMSR[3]. RX 4 6 C3 I RTS# 16 21 A3 O 3 XR16M581 1.62V TO 3.63V UART WITH 16-BYTE FIFO AND VLIO INTERFACE Pin Description NAME CTS# 24-QFN PIN# 18 32-QFN PIN# 24 25-BGA PIN# A1 TYPE I DESCRIPTION UART Clear-to-Send (active low) or general purpose input. It can be used for auto CTS flow control, see EFR[7], MSR[4] and IER[7]. This input should be connected to VCC when not used. UART Data-Terminal-Ready (active low) or general purpose output. UART Data-Set-Ready (active low) or general purpose input. This input should be connected to VCC when not used. UART Carrier-Detect (active low) or general purpose input. This input should be connected to VCC when not used. UART Ring-Indicator (active low) or general purpose input. This input should be connected to VCC when not used. REV. 1.0.1 DTR# DSR# CD# RI# - 22 25 26 27 B3 C4 - O I I I ANCILLARY SIGNALS XTAL1 XTAL2 PwrSave 8 9 7 10 11 9 D5 C5 D4 I O I Crystal or external clock input. Crystal or buffered clock output. Power-Save (active high). This feature isolates the M581's data bus interface from the host preventing other bus activities that cause higher power drain during sleep mode. See Sleep Mode with Auto Wake-up and Power-Save Feature section for details. This pin does not have an internal pull-down resistor. This input should be connected to GND when not used. Device reset (active low). A 40 ns minimum LOW pulse on this pin will reset the internal registers and all outputs of the UART. The UART transmitter output will be held HIGH, the receiver input will be ignored and outputs are reset during reset period (see UART Reset Conditions). 1.62V to 3.63V power supply. Power supply common, ground. The center pad on the backside of the QFN package is metallic and should be connected to GND on the PCB. The thermal pad size on the PCB should be the approximate size of this center pad and should be solder mask defined. The solder mask opening should be at least 0.0025" inwards from the edge of the PCB thermal pad. No Connects. RESET# 17 23 A2 O VCC GND GND 19 11 Center Pad 28 13 Center Pad B1 B5 - Pwr Pwr Pwr NC 13 2, 15-18 - - Pin type: I=Input, O=Output, I/O= Input/output, OD=Output Open Drain. 4 XR16M581 REV. 1.0.1 1.62V TO 3.63V UART WITH 16-BYTE FIFO AND VLIO INTERFACE 1.0 PRODUCT DESCRIPTION The XR16M581 (M581) is a high performance single-channel UART with a VLIO bus interface. It has its set of device configuration registers. The configuration registers set is 16550 UART compatible for control, status and data transfer. Additionally, the M581 channel has 16 bytes of transmit and receive FIFOs, Automatic RTS/ CTS Hardware Flow Control, Automatic Xon/Xoff and Special Character Software Flow Control, infrared encoder and decoder (IrDA ver 1.0 and 1.1), programmable fractional baud rate generator with a prescaler of divide by 1 or 4, and data rate up to 20 Mbps. The XR16M581 can operate from 1.62 to 3.63 volts. The M581 is fabricated with an advanced CMOS process. Data Rate The M581 is capable of operation up to 20 Mbps at 3.3V with 4X internal sampling clock rate. The device can operate at 3.3V with a 24 MHz crystal on pins XTAL1 and XTAL2, or external clock source of 80 MHz on XTAL1 pin. With a typical crystal of 14.7456 MHz and through a software option, the user can set the prescaler bit and sampling rate for data rates of up to 3.68 Mbps. Enhanced Features The rich feature set of the M581 is available through the internal registers. Automatic hardware/software flow control, programmable transmit and receive FIFO trigger levels, selectable baud rates, infrared encoder/ decoder, modem interface controls, and a sleep mode are all standard features. MCR bit-5 provides a facility for turning off (Xon) software flow control with any incoming (RX) character. The M581 includes new features such as 9-bit (Multidrop) mode, auto RS-485 half-duplex direction control, different baud rate for TX and RX, fast IR mode and fractional baud rate generator. 5 XR16M581 1.62V TO 3.63V UART WITH 16-BYTE FIFO AND VLIO INTERFACE 2.0 FUNCTIONAL DESCRIPTIONS 2.1 CPU Interface The CPU interface is a VLIO bus interface. The VLIO bus interface is an 8-bit multiplexed address/data bus interface. Each bus cycle is asynchronous using CS#, LLA# and IOR# or IOW# inputs. A typical data bus interconnection for the VLIO bus interface is shown in Figure 3. FIGURE 3. XR16M581 TYPICAL VLIO DATA BUS INTERCONNECTIONS REV. 1.0.1 AD0 AD1 AD2 AD3 AD4 AD5 AD6 AD7 AD0 AD1 AD2 AD3 AD4 AD5 AD6 AD7 VCC VCC TX RX DTR# RTS# CTS# Serial Transceivers of RS-232 RS-485 RS-422 Or Infrared UART_IOR# UART_IOW# UART_CS# UART_INT POWERSAVE UART_RESET# IOR# IOW# CS# INT PWRSAVE RESET# DSR# CD# RI# GND 6 XR16M581 REV. 1.0.1 1.62V TO 3.63V UART WITH 16-BYTE FIFO AND VLIO INTERFACE 2.2 Serial Interface The M581 is typically used with RS-232, RS-485 and IR transceivers. The following figure shows typical connections from the UART to the different transceivers. For more information on RS-232 and RS-485/422 transceivers, go to www.exar.com or send an e-mail to uarttechsupport@exar.com. FIGURE 4. XR16M581 TYPICAL SERIAL INTERFACE CONNECTIONS VCC VCC R S -2 3 2 T r a n s c e iv e r T 1 IN R1OUT T 2 IN T 3 IN R2O UT R 3O U T R 4O U T R 5O UT GND TX RX DTR# UART RTS# CTS# DSR# CD# R I# GND R S - 2 3 2 F u ll -M o d e m S e r ia l In te r fa c e VCC VCC TX RX RTS# NC NC VCC VCC DI RO RS-485 Transceiver Full-duplex TX+ TX- UART DTR# CTS# DSR# CD# RI # RX+ DE RXRE# GND RS-485 Full-Duplex Serial Interface 7 XR16M581 1.62V TO 3.63V UART WITH 16-BYTE FIFO AND VLIO INTERFACE FIGURE 5. XR16M581 TYPICAL SERIAL INTERFACE CONNECTIONS REV. 1.0.1 VCC VCC TX RX RTS# VCC DI RO DE NC RE# RS-485 Transceiver Half-duplex Y Z UART DTR# CTS# DSR# CD# RI # A B GND RS-485 Half-Duplex Serial Interface VCC VC C IR Transceiver TXD RXD TX RX DTR# NC NC VCC UART RTS# CTS# DSR# CD# R I# GND In frared C o nn ectio n 8 XR16M581 REV. 1.0.1 1.62V TO 3.63V UART WITH 16-BYTE FIFO AND VLIO INTERFACE 2.3 Device Reset The RESET# input resets the internal registers and the serial interface outputs to their default state (see Table 16). An active low pulse of longer than 40 ns duration will be required to activate the reset function in the device. Following a power-on reset or an external reset, the M581 is software compatible with previous generation of UARTs. 2.4 Internal Registers The M581 has a set of 16550 compatible registers for controlling, monitoring and data loading and unloading. These registers function as data holding registers (THR/RHR), interrupt status and control registers (ISR/IER), a FIFO control register (FCR), receive line status and control registers (LSR/LCR), modem status and control registers (MSR/MCR), programmable data rate (clock) divisor registers (DLL/DLM/DLD), and a user accessible scratchpad register (SPR). Beyond the general 16C550 features and capabilities, the M581 offers enhanced feature registers (EFR, Xon1/ Xoff 1, Xon2/Xoff 2, DLD, FCTR, EMSR, FC and TRIG) that provide automatic RTS and CTS hardware flow control, automatic Xon/Xoff software flow control, 9-bit (Multidrop) mode, auto RS-485 half duplex control, different baud rate for TX and RX and fractional baud rate generator. All the register functions are discussed in full detail later in "Section 3.0, UART INTERNAL REGISTERS" on page 23. 2.5 INT Ouput The interrupt outputs change according to the operating mode and enhanced features setup. Table 1 and 2 summarize the operating behavior for the transmitter and receiver. Also see Figure 19 through 22. TABLE 1: INT PIN OPERATION FOR TRANSMITTER FCR BIT-0 = 0 (FIFO DISABLED) INT Pin LOW = One byte in THR HIGH = THR empty FCR BIT-0 = 1 (FIFO ENABLED) LOW = FIFO above trigger level HIGH = FIFO below trigger level or FIFO empty TABLE 2: INT PIN OPERATION FOR RECEIVER FCR BIT-0 = 0 (FIFO DISABLED) INT Pin HIGH = One byte in RHR LOW = RHR empty FCR BIT-0 = 1 (FIFO ENABLED) LOW = FIFO below trigger level HIGH = FIFO above trigger level or RX Data Timeout 9 XR16M581 1.62V TO 3.63V UART WITH 16-BYTE FIFO AND VLIO INTERFACE 2.6 Crystal Oscillator or External Clock Input REV. 1.0.1 The M581 includes an on-chip oscillator to produce a clock for the baud rate generators in the device when a crystal is connected between XTAL1 and XTAL2 as show below. The CPU data bus does not require this clock for bus operation. The crystal oscillator provides a system clock to the Baud Rate Generators (BRGs) in the UART. XTAL1 is the input to the oscillator or external clock buffer input with XTAL2 pin being the output. For programming details, see "Section 2.7, Programmable Baud Rate Generator with Fractional Divisor" on page 11. FIGURE 6. TYPICAL CRYSTAL CONNECTIONS XTAL1 XTAL2 R1 0-120 (Optional) 1.8432 MHz to 24 MHz R2 500K - 1M Y1 C1 22-47pF C2 22-47pF The on-chip oscillator is designed to use an industry standard microprocessor crystal (parallel resonant, fundamental frequency with 10-22 pF capacitance load, ESR of 20-120 ohms and 100ppm frequency tolerance) connected externally between the XTAL1 and XTAL2 pins. Typical oscillator connections are shown in Figure 6. Alternatively, an external clock can be connected to the XTAL1 pin to clock the internal baud rate generator for standard or custom rates. The BGA package has XTAL1 only, the external clock is required. For further reading on oscillator circuit, see application note DAN108 on EXAR's web site. 10 XR16M581 REV. 1.0.1 1.62V TO 3.63V UART WITH 16-BYTE FIFO AND VLIO INTERFACE 2.7 Programmable Baud Rate Generator with Fractional Divisor The M581 has independent Baud Rate Generators (BRGs) with prescalers for the transmitter and receiver. The prescalers are controlled by a software bit in the MCR register. The MCR register bit-7 sets the prescalers to divide the input crystal or external clock by 1 or 4. The output of the prescaler clocks to the BRG. The BRG further divides this clock by a programmable divisor between 1 and (216 - 0.0625) in increments of 0.0625 (1/ 16) to obtain a 16X or 8X or 4X sampling clock of the serial data rate. The sampling clock is used by the transmitter for data bit shifting and receiver for data sampling. For transmitter and receiver, the M581 provides respective BRG divisors. The BRG divisor (DLL, DLM, and DLD registers) defaults to the value of '1' (DLL = 0x01, DLM = 0x00 and DLD = 0x00) upon reset. Therefore, the BRG must be programmed during initialization to the operating data rate. The DLL and DLM registers provide the integer part of the divisor and the DLD registers provides the fractional part of the divisor. The four lower bits of the DLD are used to select a value from 0 (for setting 0000) to 0.9375 or 15/16 (for setting 1111). Programming the Baud Rate Generator Registers DLL, DLM and DLD provides the capability for selecting the operating data rate. Table 3 shows the standard data rates available with a 24MHz crystal or external clock at 16X clock rate. If the pre-scaler is used (MCR bit-7 = 1), the output data rate will be 4 times less than that shown in Table 3. At 8X sampling rate, these data rates would double. And at 4X sampling rate, they would quadruple. Also, when using 8X sampling mode, please note that the bit-time will have a jitter (+/- 1/16) whenever the DLD is non-zero and is an odd number. When using a non-standard data rate crystal or external clock, the divisor value can be calculated with the following equation(s): Required Divisor (decimal)=(XTAL1 clock frequency / prescaler) /(serial data rate x 16), with 16X mode, DLD[5:4]='00' Required Divisor (decimal)= (XTAL1 clock frequency / prescaler / (serial data rate x 8), with 8X mode, DLD[5:4] = '01' Required Divisor (decimal)= (XTAL1 clock frequency / prescaler / (serial data rate x 4), with 4X mode, DLD[5:4] = '10' The closest divisor that is obtainable in the M581 can be calculated using the following formula: ROUND( (Required Divisor - TRUNC(Required Divisor) )*16)/16 + TRUNC(Required Divisor), where DLM = TRUNC(Required Divisor) >> 8 DLL = TRUNC(Required Divisor) & 0xFF DLD = ROUND( (Required Divisor-TRUNC(Required Divisor) )*16) In the formulas above, please note that: TRUNC (N) = Integer Part of N. For example, TRUNC (5.6) = 5. ROUND (N) = N rounded towards the closest integer. For example, ROUND (7.3) = 7 and ROUND (9.9) = 10. A >> B indicates right shifting the value 'A' by 'B' number of bits. For example, 0x78A3 >> 8 = 0x0078. 2.7.1 Independent TX/RX BRG The XR16M581 has two independent sets of TX and RX baud rate generator. See Figure 7. TX and RX can work in different baud rate by setting DLD, DLL and DLM register. For example, TX can transmit data to the remote UART at 9600 bps while RX receives data from remote UART at 921.6 Kbps. For the baud rate setting, please See "Section 4.13, Baud Rate Generator Registers (DLL, DLM and DLD) - Read/Write" on page 37. 11 XR16M581 1.62V TO 3.63V UART WITH 16-BYTE FIFO AND VLIO INTERFACE FIGURE 7. BAUD RATE GENERATOR REV. 1.0.1 DLD[7]=0 Prescaler Divide by 1 XTAL1 XTAL2 Crystal Osc / Buffer Prescaler Divide by 4 MCR Bit -7= 0 (default) DLL DLM DLD[5:0] 16X or 8X or 4X Sampling Rate Clock to Transmitter 0 MCR Bit -7=1 DLD[7]=1 DLL DLM DLD[5:0] 1 DLD[6] 16X or 8X or 4X Sampling Rate Clock to Receiver TABLE 3: TYPICAL DATA RATES WITH A 24 MHZ CRYSTAL OR EXTERNAL CLOCK AT 16X SAMPLING Required Output Data Rate 400 2400 4800 9600 10000 19200 25000 28800 38400 50000 57600 75000 100000 115200 153600 200000 225000 230400 250000 300000 400000 460800 500000 750000 921600 1000000 DIVISOR FOR 16x Clock (Decimal) 3750 625 312.5 156.25 150 78.125 60 52.0833 39.0625 30 26.0417 20 15 13.0208 9.7656 7.5 6.6667 6.5104 6 5 3.75 3.2552 3 2 1.6276 1.5 DIVISOR OBTAINABLE IN M581 3750 625 312 8/16 156 4/16 150 78 2/16 60 52 1/16 39 1/16 30 26 1/16 20 15 13 9 12/16 7 8/16 6 11/16 6 8/16 6 5 3 12/16 3 4/16 3 2 1 10/16 1 8/16 DLM PROGRAM VALUE (HEX) E 2 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 DLL PROGRAM VALUE (HEX) A6 71 38 9C 96 4E 3C 34 27 1E 1A 14 F D 9 7 6 6 6 5 3 3 3 2 1 1 DLD PROGRAM VALUE (HEX) 0 0 8 4 0 2 0 1 1 0 1 0 0 0 C 8 B 8 0 0 C 4 0 0 A 8 DATA ERROR RATE (%) 0 0 0 0 0 0 0 0.04 0 0 0.08 0 0 0.16 0.16 0 0.31 0.16 0 0 0 0.16 0 0 0.16 0 12 XR16M581 REV. 1.0.1 1.62V TO 3.63V UART WITH 16-BYTE FIFO AND VLIO INTERFACE 2.8 Transmitter The transmitter section comprises of an 8-bit Transmit Shift Register (TSR) and 16 bytes of FIFO which includes a byte-wide Transmit Holding Register (THR). TSR shifts out every data bit with the 16X/8X/4X internal clock. A bit time is 16/8/4 clock periods. The transmitter sends the start-bit followed by the number of data bits, inserts the proper parity-bit if enabled, and adds the stop-bit(s). The status of the FIFO and TSR are reported in the Line Status Register (LSR bit-5 and bit-6). 2.8.1 Transmit Holding Register (THR) - Write Only The transmit holding register is an 8-bit register providing a data interface to the host processor. The host writes transmit data byte to the THR to be converted into a serial data stream including start-bit, data bits, parity-bit and stop-bit(s). The least-significant-bit (Bit-0) becomes first data bit to go out. The THR is the input register to the transmit FIFO of 16 bytes when FIFO operation is enabled by FCR bit-0. Every time a write operation is made to the THR, the FIFO data pointer is automatically bumped to the next sequential data location. 2.8.2 Transmitter Operation in non-FIFO Mode The host loads transmit data to THR one character at a time. The THR empty flag (LSR bit-5) is set when the data byte is transferred to TSR. THR flag can generate a transmit empty interrupt (ISR bit-1) when it is enabled by IER bit-1. The TSR flag (LSR bit-6) is set when TSR becomes completely empty. FIGURE 8. TRANSMITTER OPERATION IN NON-FIFO MODE Data Byte Transmit Holding Register (THR) THR Interrupt (ISR bit-1) Enabled by IER bit-1 16X or 8X or 4X Clock ( DLD[5:4] ) Transmit Shift Register (TSR) M S B L S B TXNOFIFO1 13 XR16M581 1.62V TO 3.63V UART WITH 16-BYTE FIFO AND VLIO INTERFACE 2.8.3 Transmitter Operation in FIFO Mode REV. 1.0.1 The host may fill the transmit FIFO with up to 16 bytes of transmit data. The THR empty flag (LSR bit-5) is set whenever the FIFO is empty. The THR empty flag can generate a transmit empty interrupt (ISR bit-1) when the FIFO becomes empty. The transmit empty interrupt is enabled by IER bit-1. The TSR flag (LSR bit-6) is set when TSR/FIFO becomes empty. FIGURE 9. TRANSMITTER OPERATION IN FIFO AND FLOW CONTROL MODE Transmit Data Byte Transmit FIFO THR Interrupt (ISR bit-1) falls below the programmed Trigger Level and then when becomes empty. FIFO is Enabled by FCR bit-0=1 Auto CTS Flow Control (CTS# pin) Flow Control Characters (Xoff1/2 and Xon1/2 Reg.) Auto Software Flow Control 16X or 8X or 4X Clock (DLD[5:4]) Transmit Data Shift Register (TSR) TXFIFO1 2.9 Receiver The receiver section contains an 8-bit Receive Shift Register (RSR) and 16 bytes of FIFO which includes a byte-wide Receive Holding Register (RHR). The RSR uses the 16X/8X/4X clock (DLD[5:4]) for timing. It verifies and validates every bit on the incoming character in the middle of each data bit. On the falling edge of a start or false start bit, an internal receiver counter starts counting at the 16X/8X/4X clock rate. After 8 clocks (or 4 if 8X or 2 if 4X) the start bit period should be at the center of the start bit. At this time the start bit is sampled and if it is still a logic 0 it is validated. Evaluating the start bit in this manner prevents the receiver from assembling a false character. The rest of the data bits and stop bits are sampled and validated in this same manner to prevent false framing. If there were any error(s), they are reported in the LSR register bits 2-4. Upon unloading the receive data byte from RHR, the receive FIFO pointer is bumped and the error tags are immediately updated to reflect the status of the data byte in RHR register. RHR can generate a receive data ready interrupt upon receiving a character or delay until it reaches the FIFO trigger level. Furthermore, data delivery to the host is guaranteed by a receive data ready time-out interrupt when data is not received for 4 word lengths as defined by LCR[1:0] plus 12 bits time. This is equivalent to 3.7-4.6 character times. The RHR interrupt is enabled by IER bit-0. See Figure 10 and Figure 11 below. 2.9.1 Receive Holding Register (RHR) - Read-Only The Receive Holding Register is an 8-bit register that holds a receive data byte from the Receive Shift Register. It provides the receive data interface to the host processor. The RHR register is part of the receive FIFO of 16 bytes by 11-bits wide, the 3 extra bits are for the 3 error tags to be reported in LSR register. When the FIFO is enabled by FCR bit-0, the RHR contains the first data character received by the FIFO. After the RHR is read, the next character byte is loaded into the RHR and the errors associated with the current data byte are immediately updated in the LSR bits 2-4. 14 XR16M581 REV. 1.0.1 1.62V TO 3.63V UART WITH 16-BYTE FIFO AND VLIO INTERFACE FIGURE 10. RECEIVER OPERATION IN NON-FIFO MODE 16X or 8X or 4X Clock ( DLD[5:4] ) Receive Data Shift Register (RSR) Data Bit Validation Receive Data Characters Receive Data Byte and Errors Error Tags in LSR bits 4:2 Receive Data Holding Register (RHR) RHR Interrupt (ISR bit-2) RXFIFO1 FIGURE 11. RECEIVER OPERATION IN FIFO AND AUTO RTS FLOW CONTROL MODE 16X or 8X or 4X C lock ( D LD [5:4] ) R eceive D ata Shift R egister (R SR ) D ata Bit V alidation R eceive D ata C haracters 16 bytes by 11-bit w ide FIFO E xam ple : - R X FIFO trigger level selected at 8 bytes (See N ote Below ) D ata falls to 4 Error Tags (16-sets) R eceive D ata FIFO R TS# re-asserts w hen data falls below the flow control trigger level to restart rem ote transm itter. Enable by EFR bit-6=1, M C R bit-1. R H R Interrupt (IS R bit-2) program m ed for desired FIFO trigger level. FIFO is Enabled by FC R bit-0=1 R TS# de-asserts w hen data fills above the flow control trigger level to suspend rem ote transm itter. Enable by EFR bit-6=1, M C R bit-1. FIFO Trigger=8 D ata fills to 14 Error Tags in LSR bits 4:2 R eceive D ata Byte and Errors R eceive D ata R XFIFO 1 15 XR16M581 1.62V TO 3.63V UART WITH 16-BYTE FIFO AND VLIO INTERFACE 2.10 Auto RTS (Hardware) Flow Control REV. 1.0.1 Automatic RTS hardware flow control is used to prevent data overrun to the local receiver FIFO. The RTS# output is used to request remote unit to suspend/resume data transmission. The auto RTS flow control features is enabled to fit specific application requirement (see Figure 12): * Enable auto RTS flow control using EFR bit-6. * The auto RTS function must be started by asserting RTS# output pin (MCR bit-1 to logic 1 after it is enabled). If using the Auto RTS interrupt: * Enable RTS interrupt through IER bit-6 (after setting EFR bit-4). The UART issues an interrupt when the RTS# pin makes a transition from low to high: ISR bit-5 will be set to logic 1. 2.11 Auto RTS Hysteresis With the Auto RTS function enabled, an interrupt is generated when the receive FIFO reaches the selected RX trigger level. The RTS# pin will not be forced HIGH (RTS off) until the receive FIFO reaches one trigger level above the selected trigger level in the trigger table (Table 9). The RTS# pin will return LOW after the RX FIFO is unloaded to one level below the selected trigger level. Under the above described conditions, the M581 will continue to accept data until the receive FIFO gets full. The Auto RTS function is initiated when the RTS# output pin is asserted LOW (RTS On). TABLE 4: AUTO RTS (HARDWARE) FLOW CONTROL RX TRIGGER LEVEL 1 4 8 14 INT PIN ACTIVATION 1 4 8 14 RTS# DE-ASSERTED (HIGH) (CHARACTERS IN RX FIFO) 4 8 14 14 RTS# ASSERTED (LOW) (CHARACTERS IN RX FIFO) 0 1 4 8 2.12 Auto CTS Flow Control Automatic CTS flow control is used to prevent data overrun to the remote receiver FIFO. The CTS# input is monitored to suspend/restart the local transmitter. The auto CTS flow control feature is selected to fit specific application requirement (see Figure 12): * Enable auto CTS flow control using EFR bit-7. If needed, the CTS interrupt can be enabled through IER bit-7 (after setting EFR bit-4). The UART issues an interrupt when the CTS# pin is de-asserted (HIGH): ISR bit-5 will be set to 1, and UART will suspend 16 XR16M581 REV. 1.0.1 1.62V TO 3.63V UART WITH 16-BYTE FIFO AND VLIO INTERFACE transmission as soon as the stop bit of the character in process is shifted out. Transmission is resumed after the CTS# input is re-asserted (LOW), indicating more data may be sent. FIGURE 12. AUTO RTS AND CTS FLOW CONTROL OPERATION Local UART UARTA Receiver FIFO Trigger Reached Auto RTS Trigger Level Transmitter Auto CTS Monitor RXA TXB Remote UART UARTB Transmitter Auto CTS Monitor Receiver FIFO Trigger Reached Auto RTS Trigger Level RTSA# TXA CTSB# RXB CTSA# Assert RTS# to Begin Transmission 1 ON 2 7 ON 3 8 OFF RTSB# RTSA# CTSB# TXB OFF 10 11 ON ON Data Starts 4 RXA FIFO INTA (RXA FIFO Interrupt) Receive RX FIFO Data Trigger Level 5 6 Suspend Restart 9 RTS High Threshold RTS Low Threshold 12 RX FIFO Trigger Level RTSCTS1 The local UART (UARTA) starts data transfer by asserting RTSA# (1). RTSA# is normally connected to CTSB# (2) of remote UART (UARTB). CTSB# allows its transmitter to send data (3). TXB data arrives and fills UARTA receive FIFO (4). When RXA data fills up to its receive FIFO trigger level, UARTA activates its RXA data ready interrupt (5) and continues to receive and put data into its FIFO. If interrupt service latency is long and data is not being unloaded, UARTA monitors its receive data fill level to match the upper threshold of RTS delay and de-assert RTSA# (6). CTSB# follows (7) and request UARTB transmitter to suspend data transfer. UARTB stops or finishes sending the data bits in its transmit shift register (8). When receive FIFO data in UARTA is unloaded to match the lower threshold of RTS delay (9), UARTA re-asserts RTSA# (10), CTSB# recognizes the change (11) and restarts its transmitter and data flow again until next receive FIFO trigger (12). This same event applies to the reverse direction when UARTA sends data to UARTB with RTSB# and CTSA# controlling the data flow. 17 XR16M581 1.62V TO 3.63V UART WITH 16-BYTE FIFO AND VLIO INTERFACE 2.13 Auto Xon/Xoff (Software) Flow Control REV. 1.0.1 When software flow control is enabled (See Table 15), the M581 compares one or two sequential receive data characters with the programmed Xon or Xoff-1,2 character value(s). If receive character(s) (RX) match the programmed values, the M581 will halt transmission (TX) as soon as the current character has completed transmission. When a match occurs, the Xoff (if enabled via IER bit-5) flag will be set and the interrupt output pin will be activated. Following a suspension due to a match of the Xoff character, the M581 will monitor the receive data stream for a match to the Xon-1,2 character. If a match is found, the M581 will resume operation and clear the flags (ISR bit-4). Reset initially sets the contents of the Xon/Xoff 8-bit flow control registers to a logic 0. Following reset the user can write any Xon/Xoff value desired for software flow control. Different conditions can be set to detect Xon/ Xoff characters (See Table 15) and suspend/resume transmissions. When double 8-bit Xon/Xoff characters are selected, the M581 compares two consecutive receive characters with two software flow control 8-bit values (Xon1, Xon2, Xoff1, Xoff2) and controls TX transmissions accordingly. Under the above described flow control mechanisms, flow control characters are not placed (stacked) in the user accessible RX data buffer or FIFO. In the event that the receive buffer is overfilling and flow control needs to be executed, the M581 automatically sends an Xoff message (when enabled) via the serial TX output to the remote modem. The M581 sends the Xoff-1,2 characters two-character-times (= time taken to send two characters at the programmed baud rate) after the receive FIFO crosses the programmed trigger level. To clear this condition, the M581 will transmit the programmed Xon-1,2 characters as soon as receive FIFO is less than one trigger level below the programmed trigger level. Table 5 below explains this. TABLE 5: AUTO XON/XOFF (SOFTWARE) FLOW CONTROL RX TRIGGER LEVEL 1 4 8 14 INT PIN ACTIVATION 1 4 8 14 XOFF CHARACTER(S) SENT (CHARACTERS IN RX FIFO) 1* 4* 8* 14* XON CHARACTER(S) SENT (CHARACTERS IN RX FIFO) 0 1 4 8 * After the trigger level is reached, an xoff character is sent after a short span of time (= time required to send 2 characters); for example, after 2.083ms has elapsed for 9600 baud and 10-bit word length setting. 2.14 Special Character Detect A special character detect feature is provided to detect an 8-bit character when bit-5 is set in the Enhanced Feature Register (EFR). When this character (Xoff2) is detected, it will be placed in the FIFO along with normal incoming RX data. The M581 compares each incoming receive character with Xoff-2 data. If a match exists, the received data will be transferred to the RX FIFO and ISR bit-4 will be set to indicate detection of special character. Although the Internal Register Table shows Xon, Xoff Registers with eight bits of character information, the actual number of bits is dependent on the programmed word length. Line Control Register (LCR) bits 0-1 defines the number of character bits, i.e., either 5 bits, 6 bits, 7 bits, or 8 bits. The word length selected by LCR bits 0-1 also determines the number of bits that will be used for the special character comparison. Bit-0 in the Xon, Xoff Registers corresponds with the LSB bit for the receive character. 2.15 Normal Multidrop Mode Normal multidrop mode is enabled when MSR[6] = 1 (requires EFR[4] = 1) and EFR[5] = 0 (Special Character Detect disabled). The receiver is set to Force Parity 0 (LCR[5:3] = '111') in order to detect address bytes. With the receiver initially disabled, it ignores all the data bytes (parity bit = 0) until an address byte is received (parity bit = 1). This address byte will cause the UART to set the parity error. The UART will generate an LSR 18 XR16M581 REV. 1.0.1 1.62V TO 3.63V UART WITH 16-BYTE FIFO AND VLIO INTERFACE interrupt and place the address byte in the RX FIFO. The software then examines the byte and enables the receiver if the address matches its slave address, otherwise, it does not enable the receiver. If the receiver has been enabled, the receiver will receive the subsequent data. If an address byte is received, it will generate an LSR interrupt. The software again examines the byte and if the address matches its slave address, it does not have to do anything. If the address does not match its slave address, then the receiver should be disabled. 2.15.1 Auto Address Detection Auto address detection mode is enabled when MSR[6] = 1 (requires EFR[4] = 1) and EFR bit-5 = 1. The desired slave address will need to be written into the XOFF2 register. The receiver will try to detect an address byte that matches the porgrammed character in the XOFF2 register. If the received byte is a data byte or an address byte that does not match the programmed character in the XOFF2 register, the receiver will discard these data. Upon receiving an address byte that matches the XOFF2 character, the receiver will be automatically enabled if not already enabled, and the address character is pushed into the RX FIFO along with the parity bit (in place of the parity error bit). The receiver also generates an LSR interrupt. The receiver will then receive the subsequent data. If another address byte is received and this address does not match the programmed XOFF2 character, then the receiver will automatically be disabled and the address byte is ignored. If the address byte matches XOFF2, the receiver will put this byte in the RX FIFO along with the parity bit in the parity error bit. 2.16 Infrared Mode The M581 UART includes the infrared encoder and decoder compatible to the IrDA (Infrared Data Association) version 1.0 and 1.1. The IrDA 1.0 standard that stipulates the infrared encoder sends out a 3/16 of a bit wide HIGH-pulse for each "0" bit in the transmit data stream with a data rate up to 115.2 Kbps. For the IrDA 1.1 standard, the infrared encoder sends out a 1/4 of a bit time wide HIGH-pulse for each "0" bit in the transmit data stream with a data rate up to 1.152 Mbps. This signal encoding reduces the on-time of the infrared LED, hence reduces the power consumption. See Figure 13 below. The infrared encoder and decoder are enabled by setting MCR register bit-6 to a `1'. With this bit enabled, the infrared encoder and decoder is compatible to the IrDA 1.0 standard. For the infrared encoder and decoder to be compatible to the IrDA 1.1 standard, MSR bit-7 will also need to be set to a '1' when EFR bit-4 is set to '1'. Likewise, the RX input assumes an idle level of logic zero from a reset and power up, see Figure 13. Typically, the wireless infrared decoder receives the input pulse from the infrared sensing diode on the RX pin. Each time it senses a light pulse, it returns a logic 1 to the data bit stream. 19 XR16M581 1.62V TO 3.63V UART WITH 16-BYTE FIFO AND VLIO INTERFACE FIGURE 13. INFRARED TRANSMIT DATA ENCODING AND RECEIVE DATA DECODING REV. 1.0.1 Character Start Data Bits 1 0 1 0 0 1 1 0 Stop 1 1/2 Bit Time 3/16 or 1/4 Bit Time IrEncoder-1 TX Data 0 Transmit IR Pulse (TX Pin) Bit Time Receive IR Pulse (RX pin) Bit Time 1/16 Clock Delay RX Data 0 Start 1 0 1 0 0 1 1 0 1 Stop IRdecoder-1 Data Bits Character 2.17 Sleep Mode with Auto Wake-Up and Power-Save feature The M581 supports low voltage system designs, hence, a sleep mode with auto wake-up and power-save feature is included to reduce its power consumption when the chip is not actively used. 2.17.1 Sleep mode All of these conditions must be satisfied for the M581 to enter sleep mode: no interrupts pending (ISR bit-0 = 1) sleep mode is enabled (IER bit-4 = 1) modem inputs are not toggling (MSR bits 0-3 = 0) RX input pin is idling HIGH in normal mode or LOW in infrared mode divisor is non-zero TX and RX FIFOs are empty The M581 stops its crystal oscillator to conserve power in the sleep mode. User can check the XTAL2 pin for no clock output as an indication that the device has entered the sleep mode. The M581 resumes normal operation by any of the following: a receive data start bit transition (HIGH to LOW) a data byte is loaded to the transmitter, THR or FIFO a change of logic state on any of the modem or general purpose serial inputs: CTS#, DSR#, CD#, RI# If the M581 is awakened by any one of the above conditions, it will return to the sleep mode automatically after all interrupting conditions have been serviced and cleared. If the M581 is awakened by the modem inputs, a read to the MSR is required to reset the modem inputs. In any case, the sleep mode will not be entered while 20 XR16M581 REV. 1.0.1 1.62V TO 3.63V UART WITH 16-BYTE FIFO AND VLIO INTERFACE an interrupt is pending from any channel. The M581 will stay in the sleep mode of operation until it is disabled by setting IER bit-4 to a logic 0. A word of caution: owing to the starting up delay of the crystal oscillator after waking up from sleep mode, the first few receive characters may be lost. Also, make sure the RX pin is idling HIGH or "marking" condition during sleep mode. This may not occur when the external interface transceivers (RS-232, RS-485 or another type) are also put to sleep mode and cannot maintain the "marking" condition. To avoid this, the system design engineer can use a 47k ohm pull-up resistor on each of the RX input. 2.17.2 Power-Save Feature If the address lines, data bus lines, IOW#, IOR#, CS# and modem input lines remain steady when the M581 is in sleep mode, the maximum current will be in the microamp range as specified in the DC Electrical Characteristics on page 42. If the input lines are floating or are toggling while the M581 is in sleep mode, the current can be up to 100 times more. If not using the Power-Save feature, an external buffer would be required to keep the address and data bus lines from toggling or floating to achieve the low current. But if the PowerSave feature is enabled (PwrSave pin connected to VCC), this will eliminate the need for an external buffer by internally isolating the address, data and control signals (see Figure 1 on page 1) from other bus activities that could cause wasteful power drain. The M581 enters Power-Save mode when this pin is connected to VCC and the M581 is in sleep mode (see Sleep Mode section above). Since Power-Save mode isolates the address, data and control signals, the device will wake-up only by: a receive data start bit transition (HIGH to LOW) at the RX input or a change of logic state on the modem or general purpose serial input CTS#, DSR#, CD#, RI# The M581 will return to the Power-Save mode automatically after a read to the MSR (to reset the modem input CTS#) and all interrupting conditions have been serviced and cleared. The M581 will stay in the Power-Save mode of operation until it is disabled by setting IER bit-4 to a logic 0 and/or the Power-Save pin is connected to GND. 2.17.3 Wake-up Interrupt The M581 has the wake up interrupt. By setting the FCR bit-3, wake up interrupt is enabled or disabled. The default status of wake up interrupt is disabled. Please See "Section 4.5, FIFO Control Register (FCR) Write-Only" on page 29. 21 XR16M581 1.62V TO 3.63V UART WITH 16-BYTE FIFO AND VLIO INTERFACE 2.18 Internal Loopback REV. 1.0.1 The M581 UART provides an internal loopback capability for system diagnostic purposes. The internal loopback mode is enabled by setting MCR register bit-4 to logic 1. All regular UART functions operate normally. Figure 14 shows how the modem port signals are re-configured. Transmit data from the transmit shift register output is internally routed to the receive shift register input allowing the system to receive the same data that it was sending. The TX pin is held HIGH or mark condition while RTS# and DTR# are de-asserted, and CTS#, DSR# CD# and RI# inputs are ignored. Caution: the RX input must be held HIGH during loopback test else upon exiting the loopback test the UART may detect and report a false "break" signal. FIGURE 14. INTERNAL LOOPBACK VCC T ra n s m it S h ift R e g is te r (T H R /F IF O ) M C R b it-4 = 1 Internal Data Bus Lines and Control Signals R e c e iv e S h ift R e g is te r (R H R /F IF O ) VCC RTS# Modem / General Purpose Control Logic RTS# TX RX CTS# VCC DTR# DSR# O P1# R I# O P2# CD# CTS# DTR# DSR# R I# CD# 22 XR16M581 REV. 1.0.1 1.62V TO 3.63V UART WITH 16-BYTE FIFO AND VLIO INTERFACE 3.0 UART INTERNAL REGISTERS The complete register set for the M581 is shown in Table 6 and Table 7. TABLE 6: UART INTERNAL REGISTERS A2 A1 A0 ADDRESSES REGISTER READ/WRITE COMMENTS 16C550 COMPATIBLE REGISTERS 0 0 0 0 0 0 0 0 00 01 00 01 10 00 01 10 DREV - Device Revision DVID - Device Identification Register DLL - Divisor LSB Register DLM - Divisor MSB Register DLD - Divisor Fractional Register RHR - Receive Holding Register THR - Transmit Holding Register IER - Interrupt Enable Register ISR - Interrupt Status Register FCR - FIFO Control Register LCR - Line Control Register MCR - Modem Control Register LSR - Line Status Register MSR - Modem Status Register MSR - Modem Status Register SPR - Scratch Pad Register EMSR - Enhanced Mode Select Register FC - RX/TX FIFO Level Counter Register ENHANCED REGISTERS 0 0 0 0 1 1 1 1 00 00 01 10 00 01 10 11 FC - RX/TX FIFO Level Counter Register TRIG - RX/TX FIFO Trigger Level Register FCTR - Feature Control Register EFR - Enhanced Function Reg Xon-1 - Xon Character 1 Xon-2 - Xon Character 2 Xoff-1 - Xoff Character 1 Xoff-2 - Xoff Character 2 Read-only Write-only Read/Write Read/Write Read/Write Read/Write Read/Write Read/Write LCR = 0xBF Read-only Read-only Read/Write Read/Write Read/Write Read-only Write-only Read/Write Read-only Write-only Read/Write Read/Write Read-only Read-only Write-only Read/Write Write-only Read-only LCR 0xBF, FCTR[6] = 1 LCR 0xBF EFR[4] = 1 LCR 0xBF, FCTR[6] = 0 LCR 0xBF LCR[7] = 0 if EFR[4] = 1 or LCR 0xBF if EFR[4] = 0 LCR[7] = 1, LCR 0xBF, DLL = 0x00, DLM = 0x00 LCR[7] = 1, LCR 0xBF See DLD[7:6] LCR[7] = 1, LCR 0xBF, EFR[4] = 1 LCR[7] = 0 0 1 1 1 1 1 1 1 11 00 01 10 10 11 11 11 23 XR16M581 1.62V TO 3.63V UART WITH 16-BYTE FIFO AND VLIO INTERFACE REV. 1.0.1 TABLE 7: INTERNAL REGISTERS DESCRIPTION. SHADED BITS ARE ENABLED WHEN EFR BIT-4=1 ADDRESS A2-A0 REG NAME READ/ WRITE BIT-7 BIT-6 BIT-5 BIT-4 BIT-3 BIT-2 BIT-1 BIT-0 COMMENT 16C550 Compatible Registers 000 000 001 RHR THR IER RD WR RD/WR Bit-7 Bit-7 0/ CTS# Int. Enable 010 ISR RD Bit-6 Bit-6 0/ RTS# Int. Enable Bit-5 Bit-5 0/ Xoff Int. Enable 0/ Bit-4 Bit-4 0/ Sleep Mode Enable 0/ Bit-3 Bit-3 Bit-2 Bit-2 Bit-1 Bit-1 Bit-0 Bit-0 Modem RX Line TX RX LCR[7] = 0 Stat. Int. Stat. Empty Data Enable Int. Int Int. Enable Enable Enable INT Source Bit-3 010 FCR WR INT INT INT Source Source Source LCR[7] = 0 RTS Xoff Bit-2 Bit-1 Bit-0 if EFR[4]=1 CTS Interrupt or Interrupt LCR0xBF RX FIFO RX FIFO TX FIFO TX FIFO Wake up TX RX FIFOs if EFR[4]=0 Trigger Trigger Trigger Trigger Int Enable FIFO FIFO Enable Reset Reset Divisor Enable Set TX Break Set Parity Even Parity Parity Enable Stop Bits Word Word Length Length Bit-1 Bit-0 RTS# DTR# Output Output Control Control FIFOs FIFOs Enabled Enabled 011 LCR RD/WR 100 MCR RD/WR 0/ BRG Prescaler 0/ 0/ IR Mode XonAny ENable THR & TSR Empty THR Empty Internal Lopback Enable INT Output Enable (OP2#) OP1# 101 LSR RD RX FIFO Global Error RX Break RX Framing Error RX Parity Error RX Overrun Error Delta DSR# 0 RX Data Ready LCR0xBF Delta CTS# 0 110 MSR RD WR CD# Input Fast IR RI# Input Enable 9-bit mode Bit-6 DSR# Input Disable RX CTS# Input Disable TX Delta CD# 0 Delta RI# 0 111 111 SPR EMSR RD/WR WR Bit-7 Bit-5 0 Bit-4 0 Bit-3 Invert RTS in RS485 mode Bit-3 Bit-2 Send TX immediate Bit-2 Bit-1 Bit-0 LCR0xBF FCTR[6]=0 Xoff LSR interrupt interrupt mode mode select select Bit-7 Bit-6 FIFO FIFO count count control control LCR0xBF bit-1 bit-0 FCTR[6]=1 Bit-1 Bit-0 111 FC RD Bit-5 Bit-4 24 XR16M581 REV. 1.0.1 1.62V TO 3.63V UART WITH 16-BYTE FIFO AND VLIO INTERFACE TABLE 7: INTERNAL REGISTERS DESCRIPTION. SHADED BITS ARE ENABLED WHEN EFR BIT-4=1 ADDRESS A2-A0 REG NAME READ/ WRITE BIT-7 BIT-6 BIT-5 BIT-4 BIT-3 BIT-2 BIT-1 BIT-0 COMMENT Baud Rate Generator Divisor 000 001 DREV DVID RD RD Bit-7 0 Bit-6 0 Bit-5 0 Bit-4 0 Bit-3 0 Bit-2 0 Bit-1 0 Bit-0 1 LCR[7] = 1 LCR0xBF DLL= 0x00 DLM= 0x00 LCR[7] = 1 LCR0xBF DLD[7:6] LCR[7] = 1 LCR0xBF EFR[4] = 1 000 001 010 DLL DLM DLD RD/WR RD/WR RD/WR Bit-7 Bit-7 BRG select Bit-6 Bit-6 Bit-5 Bit-5 Bit-4 Bit-4 Bit-3 Bit-3 Bit-3 Bit-2 Bit-2 Bit-2 Bit-1 Bit-1 Bit-1 Bit-0 Bit-0 Bit-0 Enable 4X Mode 8X Mode Independent BRG Enhanced Registers 000 000 001 FC TRIG RD WR Bit-7 Bit-7 RX/TX select Auto CTS# Enable Bit-6 Bit-6 Swap SCR Auto RTS# Enable Bit-5 Bit-5 0 Bit-4 Bit-4 0 Bit-3 Bit-3 RS485 interrupt mode Software Flow Cntl Bit-3 Bit-3 Bit-3 Bit-3 Bit-3 Bit-2 Bit-2 invert RX IR Software Flow Cntl Bit-2 Bit-2 Bit-2 Bit-2 Bit-2 Bit-1 Bit-1 0 Bit-0 Bit-0 0 FCTR RD/WR 010 EFR RD/WR Special Char Select Enable IER [7:4], ISR [5:4], FCR[5:3], MCR[7:5], DLD Bit-4 Bit-4 Bit-4 Bit-4 Software Flow Cntl Bit-1 Bit-1 Bit-1 Bit-1 Bit-1 Software Flow Cntl Bit-0 Bit-0 Bit-0 Bit-0 Bit-0 LCR=0XBF 100 101 110 111 XON1 RD/WR XON2 RD/WR XOFF1 RD/WR XOFF2 RD/WR Bit-7 Bit-7 Bit-7 Bit-7 Bit-6 Bit-6 Bit-6 Bit-6 Bit-5 Bit-5 Bit-5 Bit-5 4.0 INTERNAL REGISTER DESCRIPTIONS 4.1 4.2 Receive Holding Register (RHR) - Read- Only Transmit Holding Register (THR) - Write-Only SEE"RECEIVER" ON PAGE 14. SEE"TRANSMITTER" ON PAGE 13. 25 XR16M581 1.62V TO 3.63V UART WITH 16-BYTE FIFO AND VLIO INTERFACE 4.3 Interrupt Enable Register (IER) - Read/Write REV. 1.0.1 The Interrupt Enable Register (IER) masks the interrupts from receive data ready, transmit empty, line status and modem status registers. These interrupts are reported in the Interrupt Status Register (ISR). 4.3.1 IER versus Receive FIFO Interrupt Mode Operation When the receive FIFO (FCR BIT-0 = 1) and receive interrupts (IER BIT-0 = 1) are enabled, the RHR interrupts (see ISR bits 2 and 3) status will reflect the following: A. The receive data available interrupts are issued to the host when the FIFO has reached the programmed trigger level. It will be cleared when the FIFO drops below the programmed trigger level. B. FIFO level will be reflected in the ISR register when the FIFO trigger level is reached. Both the ISR register status bit and the interrupt will be cleared when the FIFO drops below the trigger level. C. The receive data ready bit (LSR BIT-0) is set as soon as a character is transferred from the shift register to the receive FIFO. It is reset when the FIFO is empty. 4.3.2 IER versus Receive/Transmit FIFO Polled Mode Operation When FCR BIT-0 equals a logic 1 for FIFO enable; resetting IER bits 0-3 enables the XR16M581 in the FIFO polled mode of operation. Since the receiver and transmitter have separate bits in the LSR either or both can be used in the polled mode by selecting respective transmit or receive control bit(s). A. LSR BIT-0 indicates there is data in RHR or RX FIFO. B. LSR BIT-1 indicates an overrun error has occurred and that data in the FIFO may not be valid. C. LSR BIT 2-4 provides the type of receive data errors encountered for the data byte in RHR, if any. D. LSR BIT-5 indicates THR is empty. E. LSR BIT-6 indicates when both the transmit FIFO and TSR are empty. F. LSR BIT-7 indicates a data error in at least one character in the RX FIFO. IER[0]: RHR Interrupt Enable The receive data ready interrupt will be issued when RHR has a data character in the non-FIFO mode or when the receive FIFO has reached the programmed trigger level in the FIFO mode. Logic 0 = Disable the receive data ready interrupt (default). Logic 1 = Enable the receiver data ready interrupt. IER[1]: THR Interrupt Enable This bit enables the Transmit Ready interrupt which is issued whenever the THR becomes empty in the nonFIFO mode or when data in the FIFO falls below the programmed trigger level in the FIFO mode. If the THR is empty when this bit is enabled, an interrupt will be generated. Logic 0 = Disable Transmit Ready interrupt (default). Logic 1 = Enable Transmit Ready interrupt. IER[2]: Receive Line Status Interrupt Enable If any of the LSR register bits 1, 2, 3 or 4 is a logic 1, it will generate an interrupt to inform the host controller about the error status of the current data byte in FIFO. LSR bit-1 generates an interrupt immediately when an overrun occurs. LSR bits 2-4 generate an interrupt when the character in the RHR has an error. However, when EMSR bit-6 changes to 1 (default is 0), LSR bit 2-4 generate an interrupt when the character is received in the RX FIFO. Please refer to "Section 4.12, Enhanced Mode Select Register (EMSR) - Write-only" on page 36. * Logic 0 = Disable the receiver line status interrupt (default). * Logic 1 = Enable the receiver line status interrupt. 26 XR16M581 REV. 1.0.1 1.62V TO 3.63V UART WITH 16-BYTE FIFO AND VLIO INTERFACE IER[3]: Modem Status Interrupt Enable * Logic 0 = Disable the modem status register interrupt (default). * Logic 1 = Enable the modem status register interrupt. IER[4]: Sleep Mode Enable (requires EFR[4] = 1) * Logic 0 = Disable Sleep Mode (default). * Logic 1 = Enable Sleep Mode. See Sleep Mode section for further details. IER[5]: Xoff Interrupt Enable (requires EFR[4]=1) * Logic 0 = Disable the software flow control, receive Xoff interrupt. (default) * Logic 1 = Enable the software flow control, receive Xoff interrupt. See Software Flow Control section for details. IER[6]: RTS# Output Interrupt Enable (requires EFR[4]=1) * Logic 0 = Disable the RTS# interrupt (default). * Logic 1 = Enable the RTS# interrupt. The UART issues an interrupt when the RTS# pin makes a transition from LOW to HIGH (if enabled by EFR bit-6). IER[7]: CTS# Input Interrupt Enable (requires EFR[4]=1) * Logic 0 = Disable the CTS# interrupt (default). * Logic 1 = Enable the CTS# interrupt. The UART issues an interrupt when CTS# pin makes a transition from LOW to HIGH (if enabled by EFR bit-7). 4.4 Interrupt Status Register (ISR) - Read-Only The UART provides multiple levels of prioritized interrupts to minimize external software interaction. The Interrupt Status Register (ISR) provides the user with six interrupt status bits. Performing a read cycle on the ISR will give the user the current highest pending interrupt level to be serviced, others are queued up to be serviced next. No other interrupts are acknowledged until the pending interrupt is serviced. The Interrupt Source Table, Table 8, shows the data values (bit 0-5) for the interrupt priority levels and the interrupt sources associated with each of these interrupt levels. 4.4.1 Interrupt Generation: * LSR is by any of the LSR bits 1, 2, 3 and 4. * RXRDY is by RX trigger level. * RXRDY Time-out is by a 4-char plus 12 bits delay timer. * TXRDY is by TX trigger level or TX FIFO empty. * MSR is by any of the MSR bits 0, 1, 2 and 3. * Receive Xon/Xoff/Special character is by detection of a Xon, Xoff or Special character. * CTS# is when the remote transmitter toggles the input pin (from LOW to HIGH) during auto CTS flow control. * RTS# is when its receiver toggles the output pin (from LOW to HIGH) during auto RTS flow control. * Wakeup interrupt is generated when the M581 wakes up from the sleep mode. 27 XR16M581 1.62V TO 3.63V UART WITH 16-BYTE FIFO AND VLIO INTERFACE 4.4.2 Interrupt Clearing: REV. 1.0.1 * LSR interrupt is cleared by a read to the LSR register. * RXRDY interrupt is cleared by reading data until FIFO falls below the trigger level. * RXRDY Time-out interrupt is cleared by reading RHR. * TXRDY interrupt is cleared by a read to the ISR register or writing to THR. * MSR interrupt is cleared by a read to the MSR register. * Xon or Xoff interrupt is cleared by a read to the ISR register. See EMSR[7]. * Special character interrupt is cleared by a read to ISR register or after next character is received. See EMSR[7]. * RTS# and CTS# flow control interrupts are cleared by a read to the MSR register. * Wakeup interrupt is cleared by a read to ISR register. ] TABLE 8: INTERRUPT SOURCE AND PRIORITY LEVEL PRIORITY LEVEL 1 2 3 4 5 6 7 BIT-5 0 0 0 0 0 0 1 0 ISR REGISTER STATUS BITS BIT-4 0 0 0 0 0 1 0 0 BIT-3 0 1 0 0 0 0 0 0 BIT-2 1 1 1 0 0 0 0 0 BIT-1 1 0 0 1 0 0 0 0 BIT-0 0 0 0 0 0 0 0 1 LSR (Receiver Line Status Register) RXRDY (Receive Data Time-out) RXRDY (Received Data Ready) TXRDY (Transmit Ready) MSR (Modem Status Register) RXRDY (Received Xon, Xoff or Special character) CTS#, RTS# change of state None (default) or Wakeup interrupt SOURCE OF INTERRUPT ISR[0]: Interrupt Status * Logic 0 = An interrupt is pending and the ISR contents may be used as a pointer to the appropriate interrupt service routine. * Logic 1 = No interrupt pending (default condition). ISR[3:1]: Interrupt Status These bits indicate the source for a pending interrupt at interrupt priority levels (See Interrupt Source Table 8). ISR[4]: Interrupt Status (requires EFR bit-4 = 1) This bit is enabled when EFR bit-4 is set to a logic 1. ISR bit-4 indicates that the receiver detected a data match of the Xoff, Xon or special character(s). ISR[5]: Interrupt Status (requires EFR bit-4 = 1) ISR bit-5 indicates that CTS# or RTS# has changed state from LOW to HIGH. ISR[7:6]: FIFO Enable Status These bits are set to a logic 0 when the FIFOs are disabled. They are set to a logic 1 when the FIFOs are enabled. 28 XR16M581 REV. 1.0.1 1.62V TO 3.63V UART WITH 16-BYTE FIFO AND VLIO INTERFACE 4.5 FIFO Control Register (FCR) - Write-Only This register is used to enable the FIFOs, clear the FIFOs, set the transmit/receive FIFO trigger levels, and enable the wake up interrupt. They are defined as follows: FCR[0]: TX and RX FIFO Enable * Logic 0 = Disable the transmit and receive FIFO (default). * Logic 1 = Enable the transmit and receive FIFOs. This bit must be set to logic 1 when other FCR bits are written or they will not be programmed. FCR[1]: RX FIFO Reset This bit is only active when FCR bit-0 is a `1'. * Logic 0 = No receive FIFO reset (default) * Logic 1 = Reset the receive FIFO pointers and FIFO level counter logic (the receive shift register is not cleared or altered). This bit will return to a logic 0 after resetting the FIFO. FCR[2]: TX FIFO Reset This bit is only active when FCR bit-0 is a `1'. * Logic 0 = No transmit FIFO reset (default). * Logic 1 = Reset the transmit FIFO pointers and FIFO level counter logic (the transmit shift register is not cleared or altered). This bit will return to a logic 0 after resetting the FIFO. FCR[3]: Enable wake up interrupt (requires EFR bit-4 = 1) * Logic 0 = Disable the wake up interrupt (default). * Logic 1 = Enable the wake up interrupt. Please refer to "Section 2.17.3, Wake-up Interrupt" on page 21. FCR[5:4]: Transmit FIFO Trigger Select (requires EFR bit-4 = 1) These 2 bits set the trigger level for the transmit FIFO. The UART will issue a transmit interrupt when the number of characters in the FIFO falls below the selected trigger level, or when it gets empty in case that the FIFO did not get filled over the trigger level on last re-load. Table 9 below shows the selections. Note that the receiver and the transmitter cannot use different trigger tables. Whichever selection is made last applies to both the RX and TX side. FCR[7:6]: Receive FIFO Trigger Select These 2 bits are used to set the trigger level for the receive FIFO. The UART will issue a receive interrupt when the number of the characters in the FIFO crosses the trigger level. Table 9 shows the complete selections. Note that the receiver and the transmitter cannot use different trigger tables. Whichever selection is made last applies to both the RX and TX side. 29 XR16M581 1.62V TO 3.63V UART WITH 16-BYTE FIFO AND VLIO INTERFACE TABLE 9: TRANSMIT AND RECEIVE FIFO TRIGGER TABLE AND LEVEL SELECTION FCR BIT-7 FCR BIT-6 FCR BIT-5 0 0 1 1 0 0 1 1 0 1 0 1 FCR BIT-4 0 1 0 1 1 4 8 14 RECEIVE TRIGGER LEVEL TRANSMIT TRIGGER LEVEL 1 4 8 14 COMPATIBILITY 16L580 REV. 1.0.1 4.6 Line Control Register (LCR) - Read/Write The Line Control Register is used to specify the asynchronous data communication format. The word or character length, the number of stop bits, and the parity are selected by writing the appropriate bits in this register. LCR[1:0]: TX and RX Word Length Select These two bits specify the word length to be transmitted or received. BIT-1 0 0 1 1 BIT-0 0 1 0 1 WORD LENGTH 5 (default) 6 7 8 LCR[2]: TX and RX Stop-bit Length Select The length of stop bit is specified by this bit in conjunction with the programmed word length. BIT-2 0 1 1 WORD LENGTH STOP BIT LENGTH (BIT TIME(S)) 1 (default) 1-1/2 2 5,6,7,8 5 6,7,8 LCR[3]: TX and RX Parity Select Parity or no parity can be selected via this bit. The parity bit is a simple way used in communications for data integrity check. See Table 10 for parity selection summary below. * Logic 0 = No parity. * Logic 1 = A parity bit is generated during the transmission while the receiver checks for parity error of the data character received. 30 XR16M581 REV. 1.0.1 1.62V TO 3.63V UART WITH 16-BYTE FIFO AND VLIO INTERFACE LCR[4]: TX and RX Parity Select If the parity bit is enabled with LCR bit-3 set to a logic 1, LCR BIT-4 selects the even or odd parity format. * Logic 0 = ODD Parity is generated by forcing an odd number of logic 1's in the transmitted character. The receiver must be programmed to check the same format (default). * Logic 1 = EVEN Parity is generated by forcing an even number of logic 1's in the transmitted character. The receiver must be programmed to check the same format. LCR[5]: TX and RX Parity Select If the parity bit is enabled, LCR BIT-5 selects the forced parity format. * LCR BIT-5 = logic 0, parity is not forced (default). * LCR BIT-5 = logic 1 and LCR BIT-4 = logic 0, parity bit is forced to a logical 1 for the transmit and receive data. * LCR BIT-5 = logic 1 and LCR BIT-4 = logic 1, parity bit is forced to a logical 0 for the transmit and receive data. TABLE 10: PARITY SELECTION LCR BIT-5 LCR BIT-4 LCR BIT-3 X 0 0 1 1 X 0 1 0 1 0 1 1 1 1 PARITY SELECTION No parity Odd parity Even parity Force parity to mark, HIGH Forced parity to space, LOW LCR[6]: Transmit Break Enable When enabled, the Break control bit causes a break condition to be transmitted (the TX output is forced to a "space', logic 0, state). This condition remains, until disabled by setting LCR bit-6 to a logic 0. * Logic 0 = No TX break condition. (default) * Logic 1 = Forces the transmitter output (TX) to a "space", logic 0, for alerting the remote receiver of a line break condition. LCR[7]: Baud Rate Divisors Enable Baud rate generator divisor (DLL/DLM/DLD) enable. * Logic 0 = Data registers are selected. (default) * Logic 1 = Divisor latch registers are selected. 31 XR16M581 1.62V TO 3.63V UART WITH 16-BYTE FIFO AND VLIO INTERFACE 4.7 Modem Control Register (MCR) or General Purpose Outputs Control - Read/Write REV. 1.0.1 The MCR register is used for controlling the serial/modem interface signals or general purpose inputs/outputs. MCR[0]: DTR# Output The DTR# pin is a modem control output. If the modem interface is not used, this output may be used as a general purpose output. * Logic 0 = Force DTR# output HIGH (default). * Logic 1 = Force DTR# output LOW. MCR[1]: RTS# Output The RTS# pin is a modem control output and may be used for automatic hardware flow control by enabled by EFR bit-6. If the modem interface is not used, this output may be used as a general purpose output. * Logic 0 = Force RTS# output HIGH (default). * Logic 1 = Force RTS# output LOW. It is required to start Auto RTS Flow Control. MCR[2]: Reserved OP1# is not available as an output pin on the M581. But it is available for use during Internal Loopback Mode. In the Loopback Mode, this bit is used to write the state of the modem RI# interface signal. MCR[3]: INT Output Enable Enable or disable INT outputs to become active or in three-state. This bit is also used to control the OP2# signal during internal loopback mode. * Logic 0 = INT output disabled (three state). During internal loopback mode, OP2# is HIGH. * Logic 1 = INT output enabled (active). During internal loopback mode, OP2# is LOW. TABLE 11: INT OUTPUT MODES MCR BIT-3 0 1 INT OUTPUT Three-State Active 32 XR16M581 REV. 1.0.1 1.62V TO 3.63V UART WITH 16-BYTE FIFO AND VLIO INTERFACE MCR[4]: Internal Loopback Enable * Logic 0 = Disable loopback mode (default). * Logic 1 = Enable local loopback mode, see loopback section and Figure 14. MCR[5]: Xon-Any Enable (requires EFR bit-4 = 1) * Logic 0 = Disable Xon-Any function (for 16C550 compatibility, default). * Logic 1 = Enable Xon-Any function. In this mode, any RX character received will resume transmit operation. The RX character will be loaded into the RX FIFO , unless the RX character is an Xon or Xoff character and the M581 is programmed to use the Xon/Xoff flow control. MCR[6]: Infrared Encoder/Decoder Enable (requires EFR bit-4 = 1) * Logic 0 = Enable the standard modem receive and transmit input/output interface. (Default) * Logic 1 = Enable infrared IrDA receive and transmit inputs/outputs. The TX/RX output/input are routed to the infrared encoder/decoder. The data input and output levels conform to the IrDA infrared interface requirement. The RX FIFO may need to be flushed upon enable. While in this mode, the infrared TX output will be LOW during idle data conditions. MCR[7]: Clock Prescaler Select (requires EFR bit-4 = 1) * Logic 0 = Divide by one. The input clock from the crystal or external clock is fed directly to the Programmable Baud Rate Generator without further modification, i.e., divide by one (default). * Logic 1 = Divide by four. The prescaler divides the input clock from the crystal or external clock by four and feeds it to the Programmable Baud Rate Generator, hence, data rates become one forth. 4.8 Line Status Register (LSR) - Read Only This register provides the status of data transfers between the UART and the host. If IER bit-2 is enabled, LSR bit 1 will generate an interrupt immediately and LSR bits 2-4 will generate an interrupt when a character with an error is in the RHR. LSR[0]: Receive Data Ready Indicator * Logic 0 = No data in receive holding register or FIFO (default). * Logic 1 = Data has been received and is saved in the receive holding register or FIFO. LSR[1]: Receiver Overrun Flag * Logic 0 = No overrun error (default). * Logic 1 = Overrun error. A data overrun error condition occurred in the receive shift register. This happens when additional data arrives while the FIFO is full. In this case the previous data in the receive shift register is overwritten. Note that under this condition the data byte in the receive shift register is not transferred into the FIFO, therefore the data in the FIFO is not corrupted by the error. LSR[2]: Receive Data Parity Error Tag * Logic 0 = No parity error (default). * Logic 1 = Parity error. The receive character in RHR does not have correct parity information and is suspect. This error is associated with the character available for reading in RHR. LSR[3]: Receive Data Framing Error Tag * Logic 0 = No framing error (default). * Logic 1 = Framing error. The receive character did not have a valid stop bit(s). This error is associated with the character available for reading in RHR. 33 XR16M581 1.62V TO 3.63V UART WITH 16-BYTE FIFO AND VLIO INTERFACE LSR[4]: Receive Break Tag REV. 1.0.1 * Logic 0 = No break condition (default). * Logic 1 = The receiver received a break signal (RX was LOW for at least one character frame time). In the FIFO mode, only one break character is loaded into the FIFO. The break indication remains until the RX input returns to the idle condition, "mark" or HIGH. LSR[5]: Transmit Holding Register Empty Flag This bit is the Transmit Holding Register Empty indicator. The THR bit is set to a logic 1 when the last data byte is transferred from the transmit holding register to the transmit shift register. The bit is reset to logic 0 concurrently with the data loading to the transmit holding register by the host. In the FIFO mode this bit is set when the transmit FIFO is empty, it is cleared when the transmit FIFO contains at least 1 byte. LSR[6]: THR and TSR Empty Flag This bit is set to a logic 1 whenever the transmitter goes idle. It is set to logic 0 whenever either the THR or TSR contains a data character. In the FIFO mode this bit is set to a logic 1 whenever the transmit FIFO and transmit shift register are both empty. LSR[7]: Receive FIFO Data Error Flag * Logic 0 = No FIFO error (default). * Logic 1 = A global indicator for the sum of all error bits in the RX FIFO. At least one parity error, framing error or break indication is in the FIFO data. This bit clears when there is no more error(s) in any of the bytes in the RX FIFO. 4.9 Modem Status Register (MSR) - Read Only This register provides the current state of the modem interface input signals. Lower four bits of this register are used to indicate the changed information. These bits are set to a logic 1 whenever a signal from the modem changes state. These bits may be used for general purpose inputs when they are not used with modem signals. Reading the higher four bits shows the status of the modem signals. MSR[0]: Delta CTS# Input Flag * Logic 0 = No change on CTS# input (default). * Logic 1 = The CTS# input has changed state since the last time it was monitored. A modem status interrupt will be generated if MSR interrupt is enabled (IER bit-3). MSR[1]: Delta DSR# Input Flag * Logic 0 = No change on DSR# input (default). * Logic 1 = The DSR# input has changed state since the last time it was monitored. A modem status interrupt will be generated if MSR interrupt is enabled (IER bit-3). MSR[2]: Delta RI# Input Flag * Logic 0 = No change on RI# input (default). * Logic 1 = The RI# input has changed from LOW to HIGH, ending of the ringing signal. A modem status interrupt will be generated if MSR interrupt is enabled (IER bit-3). MSR[3]: Delta CD# Input Flag * Logic 0 = No change on CD# input (default). * Logic 1 = Indicates that the CD# input has changed state since the last time it was monitored. A modem status interrupt will be generated if MSR interrupt is enabled (IER bit-3). 34 XR16M581 REV. 1.0.1 1.62V TO 3.63V UART WITH 16-BYTE FIFO AND VLIO INTERFACE MSR[4]: CTS Input Status CTS# pin may function as automatic hardware flow control signal input if it is enabled and selected by Auto CTS (EFR bit-7). Auto CTS Flow Control allows starting and stopping of local data transmissions based on the modem CTS# signal. A HIGH on the CTS# pin will stop UART transmitter as soon as the current character has finished transmission, and a LOW will resume data transmission. Normally MSR bit-4 bit is the complement of the CTS# input. However in the loopback mode, this bit is equivalent to the RTS# bit in the MCR register. The CTS# input may be used as a general purpose input when the modem interface is not used. MSR[5]: DSR Input Status Normally this bit is the complement of the DSR# input. In the loopback mode, this bit is equivalent to the DTR# bit in the MCR register. The DSR# input may be used as a general purpose input when the modem interface is not used. MSR[6]: RI Input Status Normally this bit is the complement of the RI# input. In the loopback mode this bit is equivalent to bit-2 in the MCR register. The RI# input may be used as a general purpose input when the modem interface is not used. MSR[7]: CD Input Status Normally this bit is the complement of the CD# input. In the loopback mode this bit is equivalent to bit-3 in the MCR register. The CD# input may be used as a general purpose input when the modem interface is not used. 4.10 Modem Status Register (MSR) - Write Only This register provides the advanced features of XR16M581. Lower four bits of this register are reserved. Writing to the higher four bits enables additional functions. MSR[3:0]: Reserved MSR[4]: Enable/Disable Transmitter (Requires EFR[4] = 1) * Logic 0 = Enable Transmitter (default). * Logic 1 = Disable Transmitter. MSR[5]: Enable/Disable Receiver (Requires EFR[4] = 1) * Logic 0 = Enable Receiver (default). * Logic 1 = Disable Receiver. MSR[6]: Enable/Disable 9-bit mode (Requires EFR[4] = 1) For the 9-bit mode information, See "Section 2.15, Normal Multidrop Mode" on page 18. * Logic 0 = Normal 8-bit mode (default). * Logic 1 = Enable 9-bit or Multidrop mode. MSR[7]: Enable/Disable fast IR mode (Requires EFR[4] = 1) The M581 supports the new fast IR transmission with data rate up to 1.152 Mbps. * Logic 0 = IrDA version 1.0, 3/16 pulse ratio, data rate up to 115.2 Kbps (default). * Logic 1 = IrDA version 1.1, 1/4 pulse ratio, data rate up to 1.152 Mbps. For more IR mode information, please See "Section 2.16, Infrared Mode" on page 19. 4.11 Scratch Pad Register (SPR) - Read/Write This is a 8-bit general purpose register for the user to store temporary data. The content of this register is preserved during sleep mode but becomes 0xFF (default) after a reset or a power off-on cycle. 35 XR16M581 1.62V TO 3.63V UART WITH 16-BYTE FIFO AND VLIO INTERFACE 4.12 Enhanced Mode Select Register (EMSR) - Write-only This register replaces SPR (during a Write) and is accessible only when FCTR[6] = 1. EMSR[1:0]: Receive/Transmit FIFO Level Count When Scratchpad Swap (FCTR[6]) is asserted, EMSR bits 1-0 controls what mode the FIFO Level Counter is operating in. TABLE 12: SCRATCHPAD SWAP SELECTION FCTR[6] EMSR[1] 0 1 1 1 X X 0 1 EMSR[0] Scratchpad is X 0 1 1 Scratchpad RX FIFO Level Counter Mode TX FIFO Level Counter Mode Alternate RX/TX FIFO Counter Mode REV. 1.0.1 During Alternate RX/TX FIFO Level Counter Mode, the first value read after EMSR bits 1-0 have been asserted will always be the RX FIFO Level Counter. The second value read will correspond with the TX FIFO Level Counter. The next value will be the RX FIFO Level Counter again, then the TX FIFO Level Counter and so on and so forth. EMSR[2]: Send TX Immediately * Logic 0 = Do not send TX immediately (default). * Logic 1 = Send TX immediately. When FIFO is enabled and this bit is set, the next data will be written to the TX shift register. Thus, the data will be sent out immediately instead of queuing in the FIFO. Every time, only 1 byte will be send out. Once this byte has been sent out, the EMSR[2] will go back to 0 automatically. If more than 1 byte will be sent out, EMSR[2] needs to be set to 1 for each byte. EMSR[3]: Invert RTS in RS485 mode * Logic 0 = RTS# output is a logic 0 during TX and a logic 1 during RX (default). * Logic 1 = RTS# output is a logic 1 during TX and a logic 0 during RX. EMSR[5:4]: Reserved EMSR[6]: LSR Interrupt Mode * Logic 0 = LSR Interrupt Delayed (default). LSR bits 2, 3, and 4 will generate an interrupt when the character with the error is in the RHR. * Logic 1 = LSR Interrupt Immediate. LSR bits 2, 3, and 4 will generate an interrupt as soon as the character is received into the FIFO. EMSR[7]: Xoff/Special character Interrupt Mode Select This bit selects how the Xoff and Special character interrupt is cleared. The XON interrupt can only be cleared by reading the ISR register. * Logic 0 = Xoff interrupt is cleared by either reading ISR register or when an XON character is received. Special character interrupt is cleared by either reading ISR register or when next character is received. (default). * Logic 1 = Xoff/Special character interrupt can only be cleared by reading the ISR register. 36 XR16M581 REV. 1.0.1 1.62V TO 3.63V UART WITH 16-BYTE FIFO AND VLIO INTERFACE 4.13 Baud Rate Generator Registers (DLL, DLM and DLD) - Read/Write These registers make-up the value of the baud rate divisor. The M581 has different DLL, DLM and DLD for transmitter and receiver. It provides more convenience for the transmitter and receiver to transmit data with different rate. The M581 uses DLD[7:6] to select TX or RX. Then it provides DLD[5:0] to select the sampling frequency and fractional baud rate divisor. The concatenation of the contents of DLM and DLL gives the 16-bit divisor value. The value is added to DLD[3:0]/16 to achieve the fractional baud rate divisor. DLD must be enabled via EFR bit-4 before it can be accessed. See Table 13 below and See "Section 2.7, Programmable Baud Rate Generator with Fractional Divisor" on page 11. DLD[5:4]: Sampling Rate Select These bits select the data sampling rate. By default, the data sampling rate is 16X. The maximum data rate will double if the 8X mode is selected and will quadruple if the 4X mode is selected. See Table 13 below. TABLE 13: SAMPLING RATE SELECT DLD[5] 0 0 1 DLD[4] 0 1 X SAMPLING RATE 16X 8X 4X DLD[6]: Independent BRG enable * Logic 0 = The Transmitter and Receiver uses the same Baud Rate Generator. (default). * Logic 1 = The Transmitter and Receiver uses different Baud Rate Generators. Use DLD[7] for selecting which baud rate generator to configure. DLD[7]: BRG select When DLD[6] = 1, this bit selects whether the values written to DLL, DLM and DLD[5:0] will be for the Transmit Baud Rate Generator or the Receive Baud Rate Generator. When DLD[6] = 0 (same Baud Rate Generator used for both TX and RX), this bit must be a logic 0 to properly write to the appropriate DLL, DLM and DLD[5:0]. . TABLE 14: BRG SELECT DLD[7] 0 0 1 1 DLD[6] 0 1 1 0 BRG Transmitter and Receiver uses same BRG. Writing to DLL, DLM and DLD[5:0] configures the BRG for both the TX and RX. Transmitter and Receiver uses different BRGs. Writing to DLL, DLM and DLD[5:0] configures the BRG for TX. Transmitter and Receiver uses different BRGs. Writing to DLL, DLM and DLD[5:0] configures the BRG for RX. Transmitter and Receiver uses same BRG. Writing to DLL, DLM and DLD[5:0] has no effect on BRG used by the TX and RX. 37 XR16M581 1.62V TO 3.63V UART WITH 16-BYTE FIFO AND VLIO INTERFACE 4.14 Trigger Level Register (TRG) - Write-Only User Programmable Transmit/Receive Trigger Level Register. TRG[7:0]: Trigger Level Register These bits are used to program desired trigger levels when trigger Table-D is selected. FCTR bit-7 selects between programming the RX Trigger Level (a logic 0) and the TX Trigger Level (a logic 1). 4.15 RX/TX FIFO Level Count Register (FC) - Read-Only This register replaces SPR (during a read) and is accessible when FCTR[6] = 1. This register is also accessible when LCR = 0xBF. It is suggested to read the FIFO Level Count Register at the Scratchpad Register location when FCTR bit-6 = 1. See Table 12. FC[7:0]: RX/TX FIFO Level Count Receive/Transmit FIFO Level Count. Number of characters in Receiver FIFO (FCTR[7] = 0) or Transmitter FIFO (FCTR[7] = 1) can be read via this register. Reading this register is not recommended when transmitting or receiving data. 4.16 Feature Control Register (FCTR) - Read/Write FCTR[1:0]: Reserved FCTR[2]: IrDa RX Inversion REV. 1.0.1 * Logic 0 = Select RX input as encoded IrDa data (Idle state will be LOW). * Logic 1 = Select RX input as inverted encoded IrDa data (Idle state will be HIGH). FCTR[3]: Auto RS-485 Direction Control * Logic 0 = Standard ST16C550 mode. Transmitter generates an interrupt when transmit holding register becomes empty and transmit shift register is shifting data out. * Logic 1 = Enable Auto RS485 Direction Control function. The direction control signal, RTS# pin, changes its output logic state from LOW to HIGH one bit time after the last stop bit of the last character is shifted out. Also, the Transmit interrupt generation is delayed until the transmitter shift register becomes empty. The RTS# output pin will automatically return to a LOW when a data byte is loaded into the TX FIFO. However, RTS# behavior can be inverted by setting EMSR[3] = 1. FCTR[5:4]: Reserved FCTR[6]: Scratchpad Swap * Logic 0 = Scratch Pad register is selected as general read and write register. ST16C550 compatible mode. * Logic 1 = FIFO Count register (Read-Only), Enhanced Mode Select Register (Write-Only). Number of characters in transmit or receive FIFO can be read via scratch pad register when this bit is set. Enhanced Mode Select Register is selected when it is written into. FCTR[7]: Programmable Trigger Register Select * Logic 0 = Registers TRG and FC selected for RX. * Logic 1 = Registers TRG and FC selected for TX. 38 XR16M581 REV. 1.0.1 1.62V TO 3.63V UART WITH 16-BYTE FIFO AND VLIO INTERFACE 4.17 Enhanced Feature Register (EFR) - Read/Write Enhanced features are enabled or disabled using this register. Bit 0-3 provide single or dual consecutive character software flow control selection (see Table 15). When the Xon1 and Xon2 and Xoff1 and Xoff2 modes are selected, the double 8-bit words are concatenated into two sequential characters. Caution: note that whenever changing the TX or RX flow control bits, always reset all bits back to logic 0 (disable) before programming a new setting. EFR[3:0]: Software Flow Control Select Single character and dual sequential characters software flow control is supported. Combinations of software flow control can be selected by programming these bits. TABLE 15: SOFTWARE FLOW CONTROL FUNCTIONS EFR BIT-3 CONT-3 0 0 1 0 1 X X X 1 0 1 0 EFR BIT-2 CONT-2 0 0 0 1 1 X X X 0 1 1 0 EFR BIT-1 CONT-1 0 X X X X 0 1 0 1 1 1 1 EFR BIT-0 CONT-0 0 X X X X 0 0 1 1 1 1 1 TRANSMIT AND RECEIVE SOFTWARE FLOW CONTROL No TX and RX flow control (default and reset) No transmit flow control Transmit Xon1, Xoff1 Transmit Xon2, Xoff2 Transmit Xon1 and Xon2, Xoff1 and Xoff2 No receive flow control Receiver compares Xon1, Xoff1 Receiver compares Xon2, Xoff2 Transmit Xon1, Xoff1 Receiver compares Xon1 or Xon2, Xoff1 or Xoff2 Transmit Xon2, Xoff2 Receiver compares Xon1 or Xon2, Xoff1 or Xoff2 Transmit Xon1 and Xon2, Xoff1 and Xoff2, Receiver compares Xon1 and Xon2, Xoff1 and Xoff2 No transmit flow control, Receiver compares Xon1 and Xon2, Xoff1 and Xoff2 EFR[4]: Enhanced Function Bits Enable Enhanced function control bit. This bit enables IER bits 4-7, ISR bits 4-5, FCR bits 3-5, MCR bits 5-7, and DLD to be modified. After modifying any enhanced bits, EFR bit-4 can be set to a logic 0 to latch the new values. This feature prevents legacy software from altering or overwriting the enhanced functions once set. Normally, it is recommended to leave it enabled, logic 1. * Logic 0 = modification disable/latch enhanced features. IER bits 4-7, ISR bits 4-5, FCR bits 3-5, MCR bits 57, and DLD are saved to retain the user settings. After a reset, the IER bits 4-7, ISR bits 4-5, FCR bits 3-5, and MCR bits 5-7, and DLD are set to a logic 0 to be compatible with ST16C550 mode (default). * Logic 1 = Enables the EFR[3:0] register bits to be modified by the user. 39 XR16M581 1.62V TO 3.63V UART WITH 16-BYTE FIFO AND VLIO INTERFACE EFR[5]: Special Character Detect Enable REV. 1.0.1 * Logic 0 = Special Character Detect Disabled (default). * Logic 1 = Special Character Detect Enabled. The UART compares each incoming receive character with data in Xoff-2 register. If a match exists, the receive data will be transferred to FIFO and ISR bit-4 will be set to indicate detection of the special character. Bit-0 corresponds with the LSB bit of the receive character. If flow control is set for comparing Xon1, Xoff1 (EFR [1:0]= `10') then flow control and special character work normally. However, if flow control is set for comparing Xon2, Xoff2 (EFR[1:0]= `01') then flow control works normally, but Xoff2 will not go to the FIFO, and will generate an Xoff interrupt and a special character interrupt, if enabled via IER bit-5. EFR[6]: Auto RTS Flow Control Enable RTS# output may be used for hardware flow control by setting EFR bit-6 to logic 1. When Auto RTS is selected, an interrupt will be generated when the receive FIFO is filled to the programmed trigger level and RTS de-asserts HIGH at the next upper trigger level/hysteresis level. RTS# will return LOW when FIFO data falls below the next lower trigger level/hysteresis level. The RTS# output must be asserted (LOW) before the auto RTS can take effect. RTS# pin will function as a general purpose output when hardware flow control is disabled. * Logic 0 = Automatic RTS flow control is disabled (default). * Logic 1 = Enable Automatic RTS flow control. EFR[7]: Auto CTS Flow Control Enable Automatic CTS Flow Control. * Logic 0 = Automatic CTS flow control is disabled (default). * Logic 1 = Enable Automatic CTS flow control. Data transmission stops when CTS# input de-asserts to logic 1. Data transmission resumes when CTS# returns to a logic 0. 4.18 Software Flow Control Registers (XOFF1, XOFF2, XON1, XON2) - Read/Write These registers are used as the programmable software flow control characters xoff1, xoff2, xon1, and xon2. For more details, see Table 5. The xoff2 is also used as auto address detect register when the auto 9-bit mode enabled. See "Section 2.15.1, Auto Address Detection" on page 19. 40 XR16M581 REV. 1.0.1 1.62V TO 3.63V UART WITH 16-BYTE FIFO AND VLIO INTERFACE TABLE 16: UART RESET CONDITIONS REGISTERS RESET STATE DLM, DLL DLM = 0x00 and DLL = 0x01. Only resets to these val(Both TX and RX) ues during a power up. They do not reset when the Reset Pin is asserted. DLD RHR THR IER FCR ISR LCR MCR LSR MSR SPR EMSR FC TRG FCTR EFR XON1 XON2 XOFF1 XOFF2 I/O SIGNALS TX RTS# DTR# INT HIGH HIGH HIGH Three-State Condition Bits 7-0 = 0x00 Bits 7-0 = 0xXX Bits 7-0 = 0xXX Bits 7-0 = 0x00 Bits 7-0 = 0x00 Bits 7-0 = 0x01 Bits 7-0 = 0x00 Bits 7-0 = 0x00 Bits 7-0 = 0x60 Bits 7-0 =0xX0 (Read-only) Bits 7-4 = 0000 (Write-only) Bits 7-0 = 0xFF Bits 7-0 = 0x00 Bits 7-0 = 0x00 Bits 7-0 = 0x00 Bits 7-0 = 0x00 Bits 7-0 = 0x00 Bits 7-0 = 0x00 Bits 7-0 = 0x00 Bits 7-0 = 0x00 Bits 7-0 = 0x00 RESET STATE 41 XR16M581 1.62V TO 3.63V UART WITH 16-BYTE FIFO AND VLIO INTERFACE REV. 1.0.1 ABSOLUTE MAXIMUM RATINGS Power Supply Range Voltage at Any Pin Operating Temperature Storage Temperature Package Dissipation 3.6 Volts GND-0.3 V to 3.6 V -40o to +85oC -65o to +150oC 500 mW TYPICAL PACKAGE THERMAL RESISTANCE DATA (MARGIN OF ERROR: 15%) Thermal Resistance (24-QFN) Thermal Resistance (32-QFN) Thermal Resistance (25-BGA) theta-ja = 38oC/W, theta-jc = 26oC/W theta-ja = 33oC/W, theta-jc = 22oC/W theta-ja = 166oC/W, theta-jc = 98.2oC/W ELECTRICAL CHARACTERISTICS DC ELECTRICAL CHARACTERISTICS UNLESS OTHERWISE NOTED: TA = -40O TO +85OC, VCC IS 1.62 TO 3.63V SYMBOL VILCK VIHCK VIL VIH VOL PARAMETER Clock Input Low Level Clock Input High Level Input Low Voltage Input High Voltage Output Low Voltage 0.4 0.4 VOH Output High Voltage 1.8 1.4 IIL IIH CIN ICC ISLEEP/ IPWRSV Test 1: The following inputs remain steady at VCC or GND state to minimize Sleep current: AD0-AD7, IOR#, IOW#, CS# and LLA#. Also, RX input must idle at HIGH while asleep. Input Low Leakage Current Input High Leakage Current Input Pin Capacitance Power Supply Current Sleep / Power Save Current 15 15 5 1.5 3 15 15 5 2 8 15 15 5 2.5 15 uA uA pF mA uA Ext Clk = 5MHz See Test 1 2.0 LIMITS 1.8V MIN MAX -0.3 1.4 -0.3 1.4 0.3 VCC 0.2 VCC LIMITS 2.5V MIN MAX -0.3 2.0 -0.3 1.8 0.4 VCC 0.5 VCC LIMITS 3.3V MIN MAX -0.3 2.4 -0.3 2.0 0.6 VCC 0.7 VCC 0.4 UNITS V V V V V V V V V IOL = 6 mA IOL = 4 mA IOL = 1.5 mA IOH = -4 mA IOH = -2 mA IOH = -200 uA CONDITIONS 42 XR16M581 REV. 1.0.1 1.62V TO 3.63V UART WITH 16-BYTE FIFO AND VLIO INTERFACE For Power-Save, the UART internally isolates all of these inputs (except the modem inputs and Reset pins) therefore eliminating any unnecessary external buffers to keep the inputs steady. SEE"POWER-SAVE FEATURE" ON PAGE 21. To achieve minimum power drain, the voltage at any of the inputs of the M581 should NOT be lower than its VCC supply. AC ELECTRICAL CHARACTERISTICS TA = -40O TO +85OC, VCC IS 1.62 TO 3.6V, 25 PF LOAD WHERE APPLICABLE SYMBOL XTAL1 ECLK TECLK TAS TAH TCSL TLLA TRD TLLAR TLLAW TDY TRDV TDD TWR TDS TDH TWDO TMOD TRSI TSSI TRRI TSI TINT TWRI TSSR PARAMETER UART Crystal Frequency External Clock Frequency External Clock Time Period Address Setup Time Address Hold Time Delay from CS# to LLA#/IOR#/IOW# LLA# Strobe Width IOR# Strobe Width Delay from LLA# to IOR# Delay from LLA# to IOW# Read/Write Cycle Delay Data Access Time Data Disable Time IOW# Strobe Width Data Setup Time Data Hold Time Delay From IOW# To Output Delay To Set Interrupt From MODEM Input Delay To Reset Interrupt From IOR# Delay From Stop To Set Interrupt Delay From IOR# To Reset Interrupt Delay From Start To Interrupt Delay From Initial INT Reset To Transmit Start Delay From IOW# To Reset Interrupt Delay From Stop To Set RXRDY# 8 10 10 3 50 50 50 1 45 45 24 45 1 8 12 10 3 0 10 40 2 2 40 40 20 10 8 2 50 50 50 1 45 45 24 45 1 8 LIMITS 1.8V 10% MIN MAX 24 40 7 8 2 0 10 25 2 2 25 20 10 10 6 2 50 50 50 1 45 45 24 45 1 LIMITS 2.5V 10% MIN MAX 24 64 6 6 2 0 10 20 2 2 20 15 10 LIMITS 3.3V 10% MIN MAX 24 80 UNIT MHz MHz ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns Bclk ns ns Bclk ns Bclk 43 XR16M581 1.62V TO 3.63V UART WITH 16-BYTE FIFO AND VLIO INTERFACE AC ELECTRICAL CHARACTERISTICS TA = -40O TO +85OC, VCC IS 1.62 TO 3.6V, 25 PF LOAD WHERE APPLICABLE SYMBOL TRR TWT TSRT TRST Bclk PARAMETER Delay From IOR# To Reset RXRDY# Delay From IOW# To Set TXRDY# Delay From Center of Start To Reset TXRDY# Reset Pulse Width Baud Clock 40 LIMITS 1.8V 10% MAX MIN 45 45 8 40 16X or 8X or 4X of data rate LIMITS 2.5V 10% MAX MIN 45 45 8 40 LIMITS 3.3V 10% MAX MIN 45 45 8 UNIT ns ns Bclk ns Hz REV. 1.0.1 FIGURE 15. CLOCK TIMING CLK EXTERNAL CLOCK OSC CLK FIGURE 16. MODEM INPUT/OUTPUT TIMING IO W # IO W A c t iv e TW RTS# DTR# C h a n g e o f s ta te DO C h a n g e o f s ta te CD# CTS# DSR# TMOD IN T C h a n g e o f s ta te C h a n g e o f s ta te TMOD A c t iv e T RSI A c t iv e A c t iv e IO R # A c t iv e A c t iv e A c t iv e TMOD R I# C h a n g e o f s ta te 44 XR16M581 REV. 1.0.1 1.62V TO 3.63V UART WITH 16-BYTE FIFO AND VLIO INTERFACE FIGURE 17. DATA BUS READ TIMING AD7AD0 Upper Address T AS Lower Address Data TDD T AH CS# TCSL LLA# TLLA TCSL TRDV TLLAR TRD IOR# TDY FIGURE 18. DATA BUS WRITE TIMING AD7AD0 Upper Address TAS Lower Address Data TDH TAH CS# TCSL LLA# TLLA TDS TCSL TLLAW TWR IOW# TDY 45 XR16M581 1.62V TO 3.63V UART WITH 16-BYTE FIFO AND VLIO INTERFACE FIGURE 19. RECEIVE READY & INTERRUPT TIMING [NON-FIFO MODE] RX Start Bit Stop Bit TSSR 1 Byte in RHR TSSR Active Data Ready TRR REV. 1.0.1 D0:D7 D0:D7 TSSR 1 Byte in RHR TSSR Active Data Ready TRR D0:D7 TSSR 1 Byte in RHR TSSR Active Data Ready TRR INT RXRDY# IOR# (Reading data out of RHR) RXNFM FIGURE 20. TRANSMIT READY & INTERRUPT TIMING [NON-FIFO MODE] TX Start Bit Stop Bit (Unloading) IER[1] enabled D0:D7 D0:D7 D0:D7 ISR is read ISR is read ISR is read INT* TWRI TSRT TWRI TSRT TWRI TSRT TXRDY# TWT TWT TWT IOW# (Loading data into THR) *INT is cleared when the ISR is read or when data is loaded into the THR. TXNonFIFO 46 XR16M581 REV. 1.0.1 1.62V TO 3.63V UART WITH 16-BYTE FIFO AND VLIO INTERFACE FIGURE 21. RECEIVE READY & INTERRUPT TIMING [FIFO MODE] Start Bit RX S D0:D7 Stop Bit S D0:D7 T D0:D7 TSSI S D0:D7 T S D0:D7 T S D0:D7 T S D0:D7 T RX FIFO drops below RX Trigger Level INT TSSR RXRDY# First Byte is Received in RX FIFO IOR# (Reading data out of RX FIFO) RX FIFO fills up to RX Trigger Level or RX Data Timeout FIFO Empties TRRI TRR RXINTDMA# FIGURE 22. TRANSMIT READY & INTERRUPT TIMING [FIFO MODE] Start Bit Stop Bit TX FIFO Empty Last Data Byte Transmitted S D0:D7 T S D0:D7 T TSI T S D0:D7 T S D0:D7 T ISR is read TSRT S D0:D7 T TX (Unloading) IER[1] enabled S D0:D7 T ISR is read INT* TX FIFO fills up to trigger level TX FIFO drops below trigger level TX FIFO Empty TWRI TXRDY# Data in TX FIFO TWT IOW# (Loading data into FIFO) *INT is cleared when the ISR is read or when TX FIFO fills up to the trigger level. TXDMA# 47 XR16M581 1.62V TO 3.63V UART WITH 16-BYTE FIFO AND VLIO INTERFACE REV. 1.0.1 PACKAGE DIMENSIONS (24 PIN QFN - 4 X 4 X 0.9 mm) Note: the actual center pad is metallic and the size (D2) is device-dependent with a typical tolerance of 0.3mm Note: The control dimension is in millimeter. INCHES SYMBOL A A1 A3 D D2 b e L k MIN 0.031 0.000 0.006 0.154 0.098 0.007 MAX 0.039 0.002 0.010 0.161 0.110 0.012 MILLIMETERS MIN 0.80 0.00 0.15 3.90 2.50 0.18 0.50 BSC 0.35 0.20 0.45 MAX 1.00 0.05 0.25 4.10 2.80 0.30 0.0197 BSC 0.014 0.008 0.018 - 48 XR16M581 REV. 1.0.1 1.62V TO 3.63V UART WITH 16-BYTE FIFO AND VLIO INTERFACE PACKAGE DIMENSIONS (32 PIN QFN - 5 X 5 X 0.9 mm) Note: the actual center pad is metallic and the size (D2) is device-dependent with a typical tolerance of 0.3mm Note: The control dimension is in millimeter. INCHES SYMBOL A A1 A3 D D2 b e L k MIN 0.031 0.000 0.006 0.193 0.138 0.007 MAX 0.039 0.002 0.010 0.201 0.150 0.012 MILLIMETERS MIN 0.80 0.00 0.15 4.90 3.50 0.18 0.50 BSC 0.35 0.20 0.45 MAX 1.00 0.05 0.25 5.10 3.80 0.30 0.0197 BSC 0.012 0.008 0.020 - 49 XR16M581 1.62V TO 3.63V UART WITH 16-BYTE FIFO AND VLIO INTERFACE REV. 1.0.1 PACKAGE DIMENSIONS (25 PIN BGA - 3 X 3 X 0.8 mm) 5 4 3 2 1 A B A1 corner D D1 C D E D1 D (A1 corner feature is mfger option) Seating Plane A A1 A2 b e Note: The control dimension is the millimeter column INCHES SYMBOL A A1 A2 D D1 b e MIN 0.028 0.005 0.022 0.114 MAX 0.031 0.007 0.024 0.122 MILLIMETERS MIN 0.70 0.13 0.57 2.90 2.00 BSC 0.20 0.50 BSC 0.30 MAX 0.80 0.19 0.61 3.10 0.079 BSC 0.008 0.012 0.020 BSC 50 XR16M581 REV. 1.0.1 1.62V TO 3.63V UART WITH 16-BYTE FIFO AND VLIO INTERFACE REVISION HISTORY DATE February 2009 August 2009 REVISION Rev 1.0.0 Rev 1.0.1 Final Datasheet. Updated AC electrical characteristics TLLAR and TLLAW from 10ns to 2ns. DESCRIPTION NOTICE EXAR Corporation reserves the right to make changes to the products contained in this publication in order to improve design, performance or reliability. EXAR Corporation assumes no responsibility for the use of any circuits described herein, conveys no license under any patent or other right, and makes no representation that the circuits are free of patent infringement. Charts and schedules contained here in are only for illustration purposes and may vary depending upon a user's specific application. While the information in this publication has been carefully checked; no responsibility, however, is assumed for inaccuracies. EXAR Corporation does not recommend the use of any of its products in life support applications where the failure or malfunction of the product can reasonably be expected to cause failure of the life support system or to significantly affect its safety or effectiveness. Products are not authorized for use in such applications unless EXAR Corporation receives, in writing, assurances to its satisfaction that: (a) the risk of injury or damage has been minimized; (b) the user assumes all such risks; (c) potential liability of EXAR Corporation is adequately protected under the circumstances. Copyright 2009 EXAR Corporation Datasheet August 2009. Send your UART technical inquiry with technical details to hotline: uarttechsupport@exar.com. Reproduction, in part or whole, without the prior written consent of EXAR Corporation is prohibited. 51 |
Price & Availability of XR16M581 |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |