60W Triple Output Medical Type Features : 4"x2" miniature size Universal AC input / Full range Low leakage current<200uA R P T- 6 0 series Protections: Short circuit / Overload / Over voltage Cooling by free air convection UL60601-1/IEC60601-1/EN60601-1 medical safety approved UL60950-1/IEC60950-1/EN60950-1 ITE safety approved Fixed switch frequency at 100KHz 3 years warranty EN60601-1 IEC60601-1 SPECIFICATION MODEL OUTPUT NUMBER DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER OUTPUT PEAK LOAD(10sec.) RPT-60A CH1 5V 4A 0.5 ~ 4.4A 46.5W Note.4 51.15W RPT-60B CH2 12V 2A 0.1 ~ 2.2A CH3 -5V 0.5A 0.1 ~ 0.55A CH1 5V 4A 0.5 ~ 4.4A 50W 55W 80mVp-p 6.0% 1.0% 2.0% 80mVp-p +9,-8% 1.0% +5,-7% 80mVp-p +3,-2% 0.5% 1.5% 80mVp-p 6.0% 1.0% 2.0% 100mVp-p +6,-10% 2.0% 5.0% CH2 12V 2A 0.1 ~ 2.2A CH3 -12V 0.5A 0.1 ~ 0.55A RPT-60C CH1 5V 4A 0.5 ~ 4.4A 50W 55W 80mVp-p +3,-2% 0.5% 1.5% 100mVp-p 6.0% 2.0% 3.0% 150mVp-p 8.0% 2.0% 4.0% CH2 15V 1.5A 0.1 ~ 1.65A CH3 -15V 0.5A 0.1 ~ 0.55A RIPPLE & NOISE (max.) Note.2 80mVp-p VOLTAGE TOLERANCE Note.3 +3,-2% LINE REGULATION LOAD REGULATION SETUP, RISE TIME HOLD UP TIME (Typ.) VOLTAGE RANGE FREQUENCY RANGE EFFICIENCY (Typ.) AC CURRENT (Typ.) INRUSH CURRENT (Typ.) LEAKAGE CURRENT OVERLOAD 0.5% 1.5% 70ms/230VAC 90 ~ 264VAC 47 ~ 63Hz 77% 1.1A/115VAC 200ms, 15ms/230VAC 200ms, 15ms/115VAC at full load 15ms/115VAC at full load 127 ~ 370VDC 78% 0.7A/230VAC 30A/115VAC 79% INPUT COLD START 60A/230VAC For earth <200uA/264VAC, For patient <100uA/264VAC 115 ~ 150% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed CH1: 5.75 ~ 6.75V Protection type : Shut down o/p voltage, re-power on to recover -20 ~ +65 (Refer to output load derating curve) 20 ~ 90% RH non-condensing -40 ~ +85 , 10 ~ 95% RH 0.03%/ (0 ~ 45 ) 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes UL60950-1, TUV EN60950-1, UL60601-1, TUV EN60601-1, IEC60601-1 approved I/P-O/P:4KVAC I/P-FG:1.5KVAC O/P-FG:1.5KVAC PROTECTION OVER VOLTAGE WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS WITHSTAND VOLTAGE SAFETY & ISOLATION RESISTANCE EMC (Note 5) I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC EMI CONDUCTION & RADIATION Compliance to EN55011(CISPR11),EN55022 (CISPR22) Class B HARMONIC CURRENT Compliance to EN61000-3-2,-3 Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, EN60601-1-2, EN61204-3, medical level, criteria A EMS IMMUNITY MTBF 677.8Khrs min. MIL-HDBK-217F (25 ) DIMENSION PACKING 101.6*50.8*29mm (L*W*H) 0.15Kg; 96pcs/15.4Kg/0.89CUFT OTHERS NOTE 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. 33% Duty cycle maximum within every 30 seconds. Average output power should not exceed the rated power. 5. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. 6. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time. File Name:RPT-60-SPEC 2008-03-25 60W Triple Output Medical Type Features : 4"x2" miniature size Universal AC input / Full range Low leakage current<200uA R P T- 6 0 series Protections: Short circuit / Overload / Over voltage Cooling by free air convection UL60601-1/IEC60601-1/EN60601-1 medical safety approved UL60950-1/IEC60950-1/EN60950-1 ITE safety approved Fixed switch frequency at 100KHz 3 years warranty EN60601-1 IEC60601-1 SPECIFICATION MODEL OUTPUT NUMBER DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER OUTPUT PEAK LOAD(10sec.) RPT-60D CH1 5V 3.5A 0.5 ~ 3.85A 47.5W Note.4 52.25W RPT-6003 CH2 24V 1A 0.1 ~ 1.1A CH3 12V 0.5A 0.1 ~ 0.55A CH1 3.3V 5A 0.5 ~ 5.5A 39.9W 43.9W 150mVp-p 6.0% 2.0% 3.0% 15ms/115VAC at full load 127 ~ 370VDC 75% 0.7A/230VAC 30A/115VAC 80mVp-p 8.0% 2.0% 4.0% 80mVp-p +3,-2% 0.5% 1.5% 80mVp-p 8.0% 1.0% 2.0% 80mVp-p +6,-10% 2.0% +5.5,-5% CH2 5V 3A 0.3 ~ 3.3A CH3 12V 0.7A 0.1 ~ 0.77A RIPPLE & NOISE (max.) Note.2 80mVp-p VOLTAGE TOLERANCE Note.3 +3,-2% LINE REGULATION LOAD REGULATION SETUP, RISE TIME HOLD UP TIME (Typ.) VOLTAGE RANGE FREQUENCY RANGE EFFICIENCY (Typ.) AC CURRENT (Typ.) INRUSH CURRENT (Typ.) LEAKAGE CURRENT OVERLOAD 0.5% 1.5% 200ms, 15ms/230VAC 70ms/230VAC 90 ~ 264VAC 47 ~ 63Hz 79% 1.1A/115VAC COLD START 60A/230VAC 200ms, 15ms/115VAC at full load INPUT For earth <200uA/264VAC, For patient <100uA/264VAC 115 ~ 150% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed CH1: 5.75 ~ 6.75V Protection type : Shut down o/p voltage, re-power on to recover -20 ~ +65 (Refer to output load derating curve) 20 ~ 90% RH non-condensing -40 ~ +85 , 10 ~ 95% RH 0.03%/ (0 ~ 45 ) 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes UL60950-1, TUV EN60950-1, UL60601-1, TUV EN60601-1, IEC60601-1 approved I/P-O/P:4KVAC I/P-FG:1.5KVAC O/P-FG:1.5KVAC CH1: 3.8 ~ 4.45V PROTECTION OVER VOLTAGE WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS WITHSTAND VOLTAGE SAFETY & ISOLATION RESISTANCE EMC (Note 5) I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC EMI CONDUCTION & RADIATION Compliance to EN55011(CISPR11),EN55022 (CISPR22) Class B HARMONIC CURRENT Compliance to EN61000-3-2,-3 Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, EN60601-1-2, EN61204-3, medical level, criteria A EMS IMMUNITY MTBF 677.8Khrs min. MIL-HDBK-217F (25 ) DIMENSION PACKING 101.6*50.8*29mm (L*W*H) 0.15Kg; 96pcs/15.4Kg/0.89CUFT OTHERS NOTE 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. 33% Duty cycle maximum within every 30 seconds. Average output power should not exceed the rated power. 5. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. 6. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time. File Name:RPT-60-SPEC 2008-03-25 60W Triple Output Medical Type Mechanical Specification 101.6 95.25 R P T- 6 0 series Unit:mm 3.175 3.175 44.45 50.8 CN1 3 2 1 1 2 3 4 5 6 CN2 43.3 3 max. 29 AC Input Connector (CN1) : JST B3P-VH or equivalent Pin No. 1 2 3 Assignment AC/N No Pin AC/L Mating Housing JST VHR or equivalent Terminal JST SVH-21T-P1.1 or equivalent DC Output Connector (CN2) : JST B6P-VH or equivalent Pin No. 1,2 3,4 5 6 Assignment V1 COM V2 V3 Mating Housing JST VHR or equivalent Terminal JST SVH-21T-P1.1 or equivalent Block Diagram RECTIFIERS & FILTER RECTIFIERS & FILTER I/P EMI FILTER RECTIFIERS & FILTER V3 fosc : 100KHz +V2 POWER SWITCHING RECTIFIERS & FILTER +V1 COM FG O.L.P. CONTROL DETECTION CIRCUIT O.V.P. Derating Curve Output Derating VS Input Voltage Ta=25 100 100 90 80 80 60 70 LOAD (%) LOAD (%) 0 10 20 30 40 50 60 65 70 (HORIZONTAL) 40 60 50 40 20 -20 90 95 100 115 120 140 160 180 200 220 240 264 AMBIENT TEMPERATURE ( ) INPUT VOLTAGE (VAC) 60Hz File Name:RPT-60-SPEC 2008-03-25 |
Price & Availability of RPT-60A
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |