![]() |
|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
Data Sheet October 6, 2005 Document: DS06-005 ver. 0.4 PDF Name: JHW250S30R2_ds.pdf JHW250S30R2 Power Modules; dc-dc Converter 36-75 Vdc Input; 30.2Vdc Output; 250W Features High efficiency - 92% at 30.2V full load Industry standard pin-out Improved Thermal Performance: Full output power with case temperature (Tc) of 85C High power density: 91 W/in3 Low output ripple and noise Industry standard Half brick: 57.9 mm x 61.0 mm x 12.7 mm (2.28 in x 2.4 in x 0.5 in) Single tightly regulated output Remote sense 2:1 input voltage range Constant switching frequency Negative Remote On/Off logic Output over current/voltage protection Overtemperature protection Output voltage adjustment Wide operating temperature range (-40C to 85C) ISO** 9001 certified manufacturing facilities RoHS Compliant Applications Distributed power architectures Wireless Networks RF Amplifier Options Positive Remote On/Off logic Auto restart after fault shutdown UL60950-1 Recognized, CSA C22.2 No. 60950-103 Certified, and EN 60950-1 (VDE 0805): 200112 Licensed (Pending) CE mark meets 73/23/EEC and 93/68/EEC directives (JHW series only) (Pending) Description The JHW250-series dc-dc converters are a new generation of DC/DC power modules designed for maximum efficiency and power density. The JHW series provide up to 250W output power in an industry standard Half-brick, which makes it an ideal choice for high voltage and high power applications. The converter incorporates synchronous rectification technology and innovative packaging techniques to achieve ultra high efficiency typically 92% at 30.2V with full load. The 5-sided encapsulated case package allows for excellent thermal performance in strict thermal environment. Threaded or nonthreaded-through holes are provided to allow easy mounting to a cold wall or addition of a heatsink for high-temperature applications. The JHW250 series power modules are isolated dc-dc converters that operate over a wide input voltage range of 36 to 75 Vdc and provide single precisely regulated output. The output is fully isolated from the input, allowing versatile polarity configurations and grounding connections. Built-in filtering for both input and output minimizes the need for external filtering. * UL is a registered trademark of Underwriters Laboratories, Inc. CSA is a registered trademark of Canadian Standards Association. VDE is a trademark of Verband Deutscher Elektrotechniker e.V. This product is intended for integration into end-user equipment. All the required procedures for CE marking of end-user equipment should be followed. (The CE mark is placed on selected products.) ** ISO is a registered trademark of the International Organization of Standards JHW250S30R2 Power Module; dc-dc Converter 36 - 75 Vdc Input; 30.2Vdc Output; 250W Data Sheet October 6, 2005 Absolute Maximum Ratings Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute stress ratings only, functional operation of the device is not implied at these or any other conditions in excess of those given in the operations sections of the data sheet. Exposure to absolute maximum ratings for extended periods can adversely affect the device reliability. Parameter Input Voltage Continuous Transient (100ms) Operating Ambient Temperature (Case) (See Thermal Considerations section) Storage Temperature I/O Isolation Voltage JHW JHW All All All VIN VIN, trans Tc Tstg -0.3 -0.3 -40 -55 80 100 100 125 1500 Vdc Vdc C C Vdc Device Symbol Min Max Unit Electrical Specifications Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions. Parameter Operating Input Voltage Maximum Input Current (VIN=0V to 36V, IO=IO, max)/(VIN=0V to 75V, IO=IO, max) Inrush Transient Input Reflected Ripple Current, peak-to-peak (5Hz to 20MHz, 12H source impedance; VIN=0V to 75V, IO= IOmax ; see Figure 13) Input Ripple Rejection (120Hz) Device JHW JHW All All Symbol VIN IIN,max It 2 Min 36 Typ 48 Max 75 9.0 2 Unit Vdc Adc As mAp-p 2 7 15 All 60 dB Fusing Considerations CAUTION: This power module is not internally fused. An input line fuse must always be used. This power module can be used in a wide variety of applications, ranging from simple standalone operation to an integrated part of a sophisticated power architecture. To preserve maximum flexibility, internal fusing is not included, however, to achieve maximum safety and system protection, always use an input line fuse. The safety agencies require a fast-acting fuse with a maximum rating of 15A for JHW250 series (see Safety Considerations section). Based on the information provided in this data sheet on inrush energy and maximum dc input current, the same type of fuse with a lower rating can be used. Refer to the fuse manufacturer's data sheet for further information. 2 Tyco Electronics Power Systems. Data Sheet October 6, 2005 JHW250S30R2 Power Module; dc-dc Converter 36 - 75 Vdc Input; 30.2Vdc Output; 250W Electrical Specifications (continued) Parameter Output Voltage Set-point (VIN=VIN,nom, IO=IO, max, Tc =25C) Device All Symbol VO, set Min 29.89 Typ 30.20 Max 30.50 Unit Vdc Output Voltage (Over all operating input voltage, resistive load, and temperature conditions until end of life) Output Regulation Line (VIN=VIN, min to VIN, max) Load (IO=IO, min to IO, max) Temperature (Tc = -40C to +100C) Output Ripple and Noise on nominal output (VIN=VIN, nom and IO=IO, min to IO, max, CO=CO,min) RMS (5Hz to 20MHz bandwidth) Peak-to-Peak (5Hz to 20MHz bandwidth) External Capacitance (type electrolytic) Output Current All VO 29.40 31.00 Vdc All All All 0.02 0.05 100 0.1 0.2 320 %Vo %Vo mV All All All All CO, max Io 1000 0 27 45 40 150 3600 8.3 mVrms mVpk-pk F Adc Output Current Limit Inception Hiccup current limit (VO < 30% of VO,set ) Average Output Short-Circuit Current (Vo 250mV and Hiccup mode) Efficiency VIN=VIN, nom, Tc=25C IO=IO, max , VO= VO,set Switching Frequency Dynamic Load Response (Io/t=5A/10s; Vin=Vin,nom; Tc=25C; Tested with a 2100F aluminum and a 1.0 F tantalum capacitor across the load.) Load Change from Io= 1A to 8.3A: Peak Deviation Settling Time (Vo<10% peak deviation) Load Change from Io= 8.3A to 1A: Peak Deviation Settling Time (Vo<10% peak deviation) All All All IO, lim IO, hic IO, s/c 10.0 12.8 10 Adc Adc % IO, max All 92.0 % All fsw 350 kHz All All All All Vpk ts Vpk ts __ __ 400 1000 400 1000 __ __ mV s mV s Tyco Electronics Power Systems 3 JHW250S30R2 Power Module; dc-dc Converter 36 - 75 Vdc Input; 30.2Vdc Output; 250W Data Sheet October 6, 2005 Isolation Specifications Parameter Isolation Capacitance Isolation Resistance Symbol Ciso Riso Min 10 Typ 440 Max Unit pF M General Specifications Parameter Calculated MTBF (VIN, nom , IO=80% of IO, max, Tc =40C) Weight Device All Min Typ Max Unit Hours tbd 112 (3.95) g (oz.) 4 Tyco Electronics Power Systems. Data Sheet October 6, 2005 JHW250S30R2 Power Module; dc-dc Converter 36 - 75 Vdc Input; 30.2Vdc Output; 250W Feature Specifications Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions. See Feature Descriptions for additional information. Parameter Remote On/Off Signal Interface (VIN=VIN, min to VIN, max ; open collector or equivalent, Signal referenced to VIN- terminal) Negative Logic: device code suffix "1" Logic Low = module On, Logic High = module Off Positive Logic: No device code suffix required Logic Low = module Off, Logic High = module On Logic Low Specification Remote On/Off Current - Logic Low On/Off Voltage: Logic Low Logic High - (Typ = Open Collector) Max allowable On/Off pin voltage (driven) Logic High maximum allowable leakage current Turn-On Delay and Rise Times (IO=IO, max) Tdelay = Time until VO = 10% of VO,set from either application of Vin with Remote On/Off set to On or operation of Remote On/Off from Off to On with Vin already applied for at least one second. Trise = time for VO to rise from 10% of VO,set to 90% of VO,set. All All All All Von/off Von/off Von/off Ion/off 0.0 __ 0.8 5 12 10 V V V A All Ion/off 50 A Device Symbol Min Typ Max Unit All Tdelay 3 ms All Trise 20 ms Output Voltage Adjustment (See Feature Descriptions) Output Voltage Set-point Adjustment Range (trim) All Vtrim 24 31 V Output Voltage Remote-sense Range (See Feature Descriptions) Output Overvoltage Protection - Latching Overtemperature Protection - Latching (See Feature Descriptions) Input Undervoltage Lockout Turn-on Threshold Turn-off Threshold Hysteresis All Vsense __ __ 1.0 V All All VO, limit Tref VIN, UVLO 33 34.8 110 38 V C All All All 34.5 32.5 --- 35 33.0 2.0 35.5 33.5 --- V V V Tyco Electronics Power Systems 5 JHW250S30R2 Power Module; dc-dc Converter 36 - 75 Vdc Input; 30.2Vdc Output; 250W Data Sheet October 6, 2005 Characteristic Curves The following figures provide typical characteristics for the JHW250S30R21-18T (30.2V, 8.3A) at 25C. The figures show negative Remote On/Off logic version. VON/OFF(V) (2V/div) VO (V) (10V/div) 9 INPUT CURRENT, IIN (A) 8 7 6 5 4 3 2 1 0 25 35 45 55 65 75 Io = 8.3A Io = 4.2A Io = 0A INPUT VOLTAGE, VO (V) OUTPUT VOLTAGE, On/Off VOLTAGE TIME, t (10 ms/div) Figure 1. Typical Input Characteristic at Room Temperature 94 90 Figure 4. Typical Start-Up Using Remote On/Off, negative logic, Co,ext = 14x150F OUTPUT VOLTAGE, INPUT VOLTAGE EFFICIENCY, (%) 86 82 78 74 70 0 1 2 3 4 Vin = 36V Vin = 48V Vin = 75V 5 6 7 8 9 OUTPUT CURRENT, IO (A) VO (V) (10V/div) VIN(V) (20V/div) TIME, t (10 ms/div) Figure 2. Typical Converter Efficiency Vs. Output current at Room Temperature Figure 5. Typical Start-Up With Application of Vin, Co,ext = 14x150F, Remote On/Off = On. OUTPUT CURRENT, OUTPUT VOLTAGE 75 Vin OUTPUT VOLTAGE, VO (V) (50mV/div) 48 Vin 36 Vin IO (A) (5A/div) VO (V) (500mV/div) TIME, t (1s/div) TIME, t (1 ms/div) Figure 3. Typical Output Ripple and Noise at Room Temperature, Io = Io,max, Co,ext = Co,min = 1000F Figure 6. Typical Transient Response to a Load Change from 1A to 8.3A at 5A/10s, Room Temperature, Co ext = 14x150F 6 Tyco Electronics Power Systems Data Sheet October 6, 2005 JHW250S30R2 Power Module; dc-dc Converter 36 - 75 Vdc Input; 30.2Vdc Output; 250W Test Configurations Design Considerations Input Source Impedance The power module should be connected to a low ac-impedance source. Highly inductive source impedance can affect the stability of the power module. For the test configuration in Figure 13, a 200F electrolytic capacitor (ESR<0.7 at 100kHz), mounted close to the power module helps ensure the stability of the unit. Consult the factory for further application guidelines. Output Capacitance Note: Measure input reflected-ripple current with a simulated source inductance (LTEST) of 12 H. Capacitor CS offsets possible battery impedance. Measure current as shown above. Figure 13. Input Reflected Ripple Current Test Setup Output capacitance and load impedance interact with the power module's output voltage regulation control system and may produce an 'unstable' output condition for the required values of capacitance and E.S.R. Minimum and maximum values of output capacitance and of the capacitor's associated E.S.R. may be dictated, depending on the module's control system. This series power module requires minimum of 1000F output capacitance placed near output pins to ensure stable operation in full range of load/line conditions. The process of determining the acceptable values of capacitance and E.S.R. is complex and is loaddependant. Tyco provides Web-based tools to assist the power module end-user in appraising and adjusting the effect of various load conditions and output capacitances on specific power modules for various load conditions. Note: Use a 1.0 F ceramic capacitor and a 1000F aluminum or tantalum capacitor. Scope measurement should be made using a BNC socket. Position the load between 51 mm and 76 mm (2 in. and 3 in.) from the module. Safety Considerations All Versions - For safety-agency approval of the system in which the power module is used, the power module must be installed in compliance with the spacing and separation requirements of the end-use safety agency standard, i.e., UL60950, CSA C22.2 No. 60950-00, and EN 60950 (VDE 0805):2001-12. "W" Versions only - For end products connected to -48V dc, or -60Vdc nominal DC MAINS (i.e. central office dc battery plant), no further fault testing is required. *Note: 60V dc nominal battery plants are not available in the U.S. or Canada. Figure 14. Output Ripple and Noise Test Setup Note: All measurements are taken at the module terminals. When socketing, place Kelvin connections at module terminals to avoid measurement errors due to socket contact resistance. All Versions - For all input voltages, other than DC MAINS, where the input voltage is less than 60V dc, if the input meets all of the requirements for SELV, then: The output may be considered SELV. Output voltages will remain within SELV limits even with internally-generated non-SELV voltages. Single component failure and fault tests were performed in the power converters. Figure 15. Output Voltage and Efficiency Test Setup Tyco Electronics Power Systems 7 JHW250S30R2 Power Module; dc-dc Converter 36 - 75 Vdc Input; 30.2Vdc Output; 250W Data Sheet October 6, 2005 Remote On/Off One pole of the input and one pole of the output are to be grounded, or both circuits are to be kept floating, to maintain the output voltage to ground voltage within ELV or SELV limits. "W" Versions only - For all input sources, other than DC MAINS, where the input voltage is between 60 and 75V dc (Classified as TNV-2 in Europe), the following must be meet, if the converter's output is to be evaluated for SELV: The input source is to be provided with reinforced insulation from any hazardous voltage, including the ac mains. One Vi pin and one Vo pin are to be reliably earthed, or both the input and output pins are to be kept floating. Another SELV reliability test is conducted on the whole system, as required by the safety agencies, on the combination of supply source and the subject module to verify that under a single fault, hazardous voltages do not appear at the module's output. All Versions - The power module has ELV (extra-low voltage) outputs when all inputs are ELV. All flammable materials used in the manufacturing of these modules are rated 94V-0. The input to these units is to be provided with a maximum 15A, (JHW250 series) fast-acting fuse in the unearthed lead. Two remote on/off options are available. Positive logic remote on/off turns the module on during a logic-high voltage on the ON/OFF pin, and off during a logic low. Negative logic remote on/off turns the module off during a logic high and on during a logic low. Negative logic, device code suffix "1," is the factory-preferred configuration. To turn the power module on and off, the user must supply a switch to control the voltage between the on/off terminal (Von/off) and the VI (-) terminal. The switch can be an open collector or equivalent (see Figure 16). A logic low is Von/off = 0 V to 0.8 V. The maximum Ion/off during a logic low is 50 A. The switch should maintain a logic-low voltage while sinking this 50 A. During logic high, the maximum Von/off generated by the power module is 5 V. The maximum allowable leakage current of the switch at Von/off = 5V is 10 A. If not using the remote on/off feature, perform one of the following to turn the unit on: For negative logic, short ON/OFF pin to VIN(-). For positive logic: leave ON/OFF pin open. Figure 16. Remote On/Off Implementation Remote sense Remote sense minimizes the effects of distribution losses by regulating the voltage at the remote-sense connections. The voltage between the remote-sense pins and the output terminals must not exceed the output voltage sense range given in the Feature Specifications table i.e.: [Vo(+) - Vo(-)] - [SENSE(+) - SENSE(-)] X% of Vo,nom. If not using the remote-sense feature to regulate the output at the point of load, then connect SENSE(+) to Vo(+) and SENSE(-) to Vo(-) at the module. Although the output voltage can be increased by both the remote sense and by the trim, the maximum increase for the output voltage is not the sum of both. The maximum increase is the larger of either the remote sense or the trim. The amount of power delivered by the module is defined as the voltage at the output terminals multiplied by the output current. When using remote sense and trim: the output voltage of the module can be increased, which at the same output current would increase the power output of the module. Care should be Feature Descriptions Overcurrent Protection - Auto-Restart To provide protection in a fault output overload condition, the module is equipped with internal current-limiting circuitry. As the load current is increased beyond its limit, the module will start to fold back its output voltage hence limiting output power. In the event of a severe overload where the output voltage is pulled lower than approximately 21V the module will enter hiccup mode to further reduce the power dissipation of the module. The module can survive a continuous short circuit. Once the overload has been removed the module will auto-restart and normal operation will resume. 8 Tyco Electronics Power Systems Data Sheet October 6, 2005 JHW250S30R2 Power Module; dc-dc Converter 36 - 75 Vdc Input; 30.2Vdc Output; 250W taken to ensure that the maximum output power of the module remains at or below the maximum rated power. Where, VO = Desired output voltage set point (V). The voltage between the Vo(+) and Vo(-) terminals must not exceed the minimum output overvoltage shut-down value indicated in the Feature Specifications table. This limit includes any increase in voltage due to remotesense compensation and output voltage set-point adjustment (trim). See Figure 17. Although the output voltage can be increased by both the remote sense and by the trim, the maximum increase for the output voltage is not the sum of both. The maximum increase is the larger of either the remote sense or the trim. The amount of power delivered by the module is defined as the voltage at the output terminals multiplied by the output current. When using remote sense and trim, the output voltage of the module can be increased, which at the same output current would increase the power output of the module. Care should be taken to ensure that the maximum output power of the module remains at or below the maximum rated power. Figure 17. Effective Circuit Configuration for SingleModule Remote-Sense Operation Output Voltage Output Voltage Set-Point Adjustment (Trim) Trimming allows the user to increase or decrease the output voltage set point of a module. This is accomplished by connecting an external resistor between the TRIM pin and either the SENSE(+) or SENSE(-) pins. The trim resistor should be positioned close to the module. If not using the trim feature, leave the TRIM pin open. With an external resistor between the TRIM and SENSE(-) pins (Radj-down), the output voltage set point (Vo,adj) decreases (see Figure 18). The following equation determines the required external-resistor value to obtain a desired output voltage. Trim down for output voltages: 30.2V Radj - down = 10 x [(2 x Vo) - 30.2] K (30.2 - Vo) Figure 18. Circuit Configuration to Decrease Output Voltage Where, VO = Desired output voltage set point (V). With an external resistor connected between the TRIM and SENSE(+) pins (Radj-up), the output voltage set point (Vo,adj) increases (see Figure 19). The following equation determines the required externalresistor value to obtain a desired output voltage. Trim up for output voltages: 30.2V Vo Radj - up = 9.5944 x (0.04056 x Vo ) - 1.225 - 10 K Figure 19. Circuit Configuration to Increase Output Voltage Tyco Electronics Power Systems 9 JHW250S30R2 Power Module; dc-dc Converter 36 - 75 Vdc Input; 30.2Vdc Output; 250W Data Sheet October 6, 2005 Trim Examples: To trim down the output of a nominal 30.2V module (JHW250S30R2) to 28.0V Radj - down = 10 x [(2 x 28) - 30.2] K (30.2 - 28) Radj-down = 117.27 K To trim up the output of a nominal 30.2V module (JHW250S30R2) to 31.0V 31.0 Radj - up = 9.5944x (0.04056x 31.0) - 1.225 - 10 K Rtadj-up = 9181 K Output Overvoltage Protection - Latching The output overvoltage protection consists of circuitry that monitors the voltage on the output terminals. If the voltage on the output terminals exceeds the over voltage protection threshold, then the module will shutdown and latch off. The latch is reset by either cycling the input power for one second or by toggling the on/off signal for one second. The protection mechanism is such that the unit can continue in this condition until the fault is cleared. Overtemperature Protection - Latching These modules feature an overtemperature protection circuit to safeguard against thermal damage. The circuit shuts down and latches off the module when the maximum baseplate reference temperature is exceeded. The latch is reset by either cycling the input power for one second or by toggling the on/off signal for one second. The protection mechanism is such that the unit can continue in this condition until the fault is cleared. Input Undervoltage Lockout At input voltages below the input undervoltage lockout limit, the module operation is disabled. The module will begin to operate at an input voltage above the undervoltage lockout turn-on threshold. 10 Tyco Electronics Power Systems Data Sheet October 6, 2005 JHW250S30R2 Power Module; dc-dc Converter 36 - 75 Vdc Input; 30.2Vdc Output; 250W Feature Descriptions (continued) OUTPUT POWER (W) 300 250 200 150 100 50 0 20 30 40 50 60 70 80 90 100 110 Thermal Considerations The power modules operate in a variety of thermal environments; however, sufficient cooling should be provided to help ensure reliable operation of the unit. Heat-dissipating components inside the unit are thermally coupled to the metal case. Heat is removed by conduction, convection, and radiation to the surrounding environment. Proper cooling can be verified by measuring the case temperature. Peak temperature (TC) occurs at the position indicated in Figure 20. Considerations include ambient temperature, airflow, module power dissipation, and the need for increased reliability. A reduction in the operating temperature of the module will result in an increase in reliability. The thermal data presented here is based on physical measurements taken in a wind tunnel. For reliable operation please refer to the power derating guidelines shown in figure 21. Under no circumstances should the absolute maximum temperature at this point exceed the 100C threshold. MEASURE CASE TEMPERATURE HERE (Tc) CASE TEMPERATURE, TC (C) Figure 21. Output Power Derating for JHW250S30R2 (Vo = 30.2V) vs Case Temperature Layout Considerations The JHW250 power module series are encapsulated aluminum case packaged style, as such; component clearance between the bottom of the power module and the mounting (Host) board is limited. Avoid placing copper areas on the outer layer directly underneath the power module. Also avoid placing via interconnects underneath the power module. For additional layout guide-lines, refer to FLTR100V20 data sheet. VI(+) ON/OFF VO(+) + SEN TRIM Post Solder Cleaning and Drying Considerations Post solder cleaning is usually the final circuit-board assembly process prior to electrical board testing. The result of inadequate cleaning and drying can affect both the reliability of a power module and the testability of the finished circuit-board assembly. For guidance on appropriate soldering, cleaning and drying procedures, refer to Tyco Electronics Board Mounted Power Modules: Soldering and Cleaning Application Note (AP01-056EPS). 30.5 (1.20) CASE VI(-) - SEN VO(-) 29.0 (1.14) Figure 20. Metal Case (Tc ) Temperature Measurement Location (top view) Although the maximum Tc temperature of the power modules is 100C, you can limit this temperature to a lower value for extremely high reliability. Tyco Electronics Power Systems 11 JHW250S30R2 Power Module; dc-dc Converter 36 - 75 Vdc Input; 30.2Vdc Output; 250W Data Sheet October 6, 2005 Mechanical Outline for Through-hole Module Dimensions are in millimeters and (inches). Tolerances: x.x mm 0.5 mm ( x.xx in. 0.02 in.) [unless otherwise indicated] x.xx mm 0.25 mm ( x.xxx in 0.010 in.) 57.9 (2.28) TOP VIEW 61.0 (2.40) SIDE LABEL* SIDE VIEW 12.70 (0.500) 0.51 (0.020) 5.08 (0.20) MIN 1.02 (0.040) DIA SOLDER-PLATED BRASS, 7 PLACES 7.1 (0.28) 2.06 (0.081) DIA SOLDER-PLATED BRASS, 2 PLACES ( - OUTPUT AND + OUTPUT) 12.7 (0.50) STANDOFF, 4 PLACES MOUNTING INSERTS M3 x 0.5 THROUGH, 4 PLACES 7.3 (0.29) BOTTOM VIEW 5.1 (0.20) VI(-) VO(-) - SEN TRIM ON/OFF VI(+) +SEN VO(+) 10.16 (0.400) 50.8 (2.00) 25.40 (1.000) CASE 10.16 (0.400) 17.78 (0.700) 25.40 (1.000) 35.56 (1.400) 35.56 (1.400) 48.26 (1.900) 4.7 (0.19) 48.3 (1.90) *Side label includes Tyco name, product designation, and data code. Option Feature, Pin is not present unless one these options specified 12 Tyco Electronics Power Systems Data Sheet October 6, 2005 JHW250S30R2 Power Module; dc-dc Converter 36 - 75 Vdc Input; 30.2Vdc Output; 250W Recommended Pad Layout for Through-Hole Modules Dimensions are in millimeters and (inches). Tolerances: x.x mm 0.5 mm ( x.xx in. 0.02 in.) [unless otherwise indicated] x.xx mm 0.25 mm ( x.xxx in 0.010 in.) Tyco Electronics Power Systems 13 JHW250S30R2 Power Module; dc-dc Converter 36 - 75 Vdc Input; 30.2Vdc Output; 250W Data Sheet October 6, 2005 Ordering Information Please contact your Tyco Electronics' Sales Representative for pricing, availability and optional features. Table 1. Device Codes Input Voltage 48V (36-75Vdc) 48V (36-75Vdc) Output Voltage 30.2V 30.2V Output Current 8.3A 8.3A Efficiency 92% 92% Connector Type Through hole Through hole Product codes JHW250S30R21-18T JHW250S30R21-18TZ Comcodes 108995965 CC109114014 Table 2. Device Options Option Negative remote on/off logic Unthreaded heatsink mounting holes Suffix 1 18 Document: DS06-005 ver. 0.4 PDF Name: JHW250S30R2_ds.pdf Europe, Middle-East and Africa Headquarters Tyco Electronics (UK) Ltd Tel: +44 (0) 1344 469 300 Latin America, Brazil, Caribbean Headquarters Tyco Electronics Power Systems Tel: +56 2 209 8211 World Wide Headquarters Tyco Electronics Power Systems, Inc. 3000 Skyline Drive, Mesquite, TX 75149, USA +1-800-843-7497 (Outside U.S.A.: +1-972-284-2626) www.power.tycoelectronics.com e-mail: techsupport1@tycoelectronics.com India Headquarters Tyco Electronics Systems India Pte. Ltd. Tel: +91 80 841 1633 x3001 Asia-Pacific Headquarters Tyco Electronics Singapore Pte. Ltd. Tel: +65 6416 4283 Tyco Electronics Corporation reserves the right to make changes to the product(s) or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. (c) 2003 Tyco Electronics Power Systems, Inc., (Mesquite, Texas) All International Rights Reserved. Document: DS06-005 ver. 0.4 PDF Name: JHW250S30R2_ds.pdf |
Price & Availability of JHW250S30R21-18T
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |