![]() |
|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
Bulletin 700S-CF Industrial Relays Overview/Product Selection Bulletin 700S-CF * * * * IEC Industrial Safety Relay Positively Guided/Mechanically Linked Contacts as Per IEC 947-5-1 Annex L Third Party Certification By SUVA Red Cover and Mechanically Linked Contact Symbol on Front Face Table Of Contents Product Selection . . . . . . 197 Specifications . . . . . . . . . 199 Approximate Dimensions . . . . . . . . . . . 200 Type CF Safety Control Relays -- 8-Pole AC Voltage AC-1 Ie [A] 40C 60C AC-11 and AC-15 Ie [A] 24/48V 120V 240V 400V 500V 600V 690V Connection Diagrams Contacts Catalog Number N.O. N.C. Main Contacts Auxiliary Contacts A1 K1 A2 13 21 33 43 53 61 71 81 4 54 62 72 82 4 700S-CF440C Main Contacts 25 20 16 14 10 5 2.5 1.8 1 A1 K1 A2 14 22 34 44 13 21 33 43 53 61 71 83 5 14 22 34 44 3 700S-CF530C 54 53 62 61 72 73 84 83 Adder Deck Contacts A1 13 21 33 43 10 6 6 6 3 2 2 1.2 0.7 K1 A2 14 22 34 44 6 54 62 74 84 2 700S-CF620C All Cat. Nos. are factory-stocked. AC Voltage Suffix Code Voltage 50 Hz 60 Hz 50/60 Hz 12 R Q - 24 K J KJ 32 V - - 36 W V - 42 X - - 48 Y X KY 100 KP - KP 100110 - KP - 110 D - KD 120 P D - 127 S - - 200 KG - KG 200220 - KG - 208 - H - 208240 - L - 220230 F - - Voltage 50 Hz 60 Hz 50/60 Hz 230 - - KF 230240 VA - - 240 T A KA 277 - T - 347 - I - 380 - E - 380400 N - - 400 - - KN 400415 G - - 440 B N KB 480 - B - 500 M - - 550 C - - 600 - C - All Cat. Nos. are factory-stocked. See page 198 for coil voltage selection information. 197 Bulletin 700S-CF Industrial Relays Product Selection, Continued Ordering Details Type CF Control Relays -- 8-Pole DC Voltage DC-1 Ie [A] DC-11 and DC-15 Ie [A] 240V 400V 500V 600V 690V Connection Diagrams Contacts 40C 60C 24/48V 120V Main Contacts A1 K1 A2 14 22 21 Auxiliary Contacts 21 33 43 53 61 71 81 Catalog Number N.O. N.C. 13 4 34 33 4 700S-CF440ZC 44 43 54 53 62 61 72 71 82 83 25 20 16 14 10 5 2.5 1.8 1 A1 K1 A2 13 5 14 13 22 21 34 33 44 43 3 700S-CF530ZC 54 53 62 61 72 73 84 83 A1 K1 A2 6 14 22 34 44 2 700S-CF620ZC 54 62 74 84 All Cat. Nos. are factory-stocked. See page 198 for coil voltage selection information. DC Voltage Suffix Code Voltage Standard With diode suppressor a 9 R -- 12 Q -- 24 J DJ 36 W -- 48 Y -- 60 Z -- 64 B -- 72 G -- 80 E -- 110 D -- 115 P -- 125 S -- 220 A -- 230 F -- 250 T -- When ordering DJ coil with built-in surge suppression, remove Z from the Cat. No. Example: Cat. No. 700S-CF440ZC becomes Catalog Number 700S-CF440DJC Accessories Safety Control Relays with Auxiliary contact block for side mounting 1- or 2-pole Electronic Timing Module on coil terminal side Mechanical Interlock on side of contactor Interface Module on coil terminal side Surge Suppressor on coil terminal side Labeling with label sheet marking tag sheet with clear cover marking tag adapter for System Bul. 1492W mm. a+9 b + 24 a+9 b+9 b+3 +0 +0 + 5.5 (inches) (a + 23/64) (b + 15/16) (a + 23/64) (b + 23/64) (b + 1/8) (+ 0) (+ 0) (+ 7/32) 198 Bulletin 700S-CF Industrial Relays Specifications General Main Relay Cat. No. 700S-CF Contact Ratings -- NEMA Min. Contact Rating Contact Ratings -- IEC AC-15 (solenoids, contactors) at rated voltage IEC 947, EN 60947 Standard Gold 24V 48V 120V 240V 400V 480V/500V 600V 690V 40C Ith 230 V AC-12 (Control of resistive loads) IEC 60947 400 V 690 V 60C Ith 230V 400V 690V DC-12 Switching DC Loads L/R Front Adder Deck Contacts Sidemounted Contacts Mechanical Life Electrical Life 6A 6A 6A 3A 2A 2A 1.2 A 0.7 A Terminal Size per IEC 947-1 Solid/Stranded 1 Conductor 2 Conductor Max. Wire Size per UL/CSA Tightening Torque Tightening Torque [mm2] [mm2] [AWG] [lb.-in.] [N*m] Terminal Type Weight AC-15 (240V, 3 A) AC Op. Mechanism [Mil] [Mil] [g] Cat. No. 700S-CF 15 1.5 390 A600, P600 A600, Q600 20V, 10 mA 12V, 8 mA Aux./Pneumatic Timer Contact (Frontmounted) 15 1.5 -- 16 A 16 A 14 A 10 A 5A 2.5 A 1.8 A 1A 25 A 10 kW 17 kW 30 kW 20 A 8 kW 14 kW 24 kW 6A 6A 6A 5A 3A 1.6 A 1.2 A 1.0 A 10 A Terminal Cross-Sections 2 x A4 1.5...6 1.5...6 16...10 8.9...22 1...2.5 2 x A4 0.5...2.5 0.75...2.5 18...14 8.9...13.3 1...1.5 6A For 16 or more strands, end ferrule is required DC Switching Ratings for 700S-CF Main Poles in Series (Resistive Load at 60 C) 1 pole 24/48 V 25/20 A 6A 1.5 A 0.4 A 2 poles 25 A 25 A 8A 1A 3 poles 25 A 25 A 25 A 3A < 1ms, Resistive Loads 24V 48V 110V 220V 440V 12 A 9A 3.5 A 0.55 A 0.2 A 5A 2A 0.7 A 0.25 A 0.12 A 0.14 A Yes 5A 2A 0.7 A 0.25 A 0.12 A 0.1 A Yes 12 A 9A 3.5 A 0.55 A 0.2 A 3A 1.5 A 0.6 A 0.3 A 0.2 A 0.1 A 125 V 220 V 440 V IEC 60947 DC-13 IEC 60947, Solenoids and contactors 24V 48V 125V 220V 440V 660V Location State of N.C. Contacts if N.O. contact welds of welded Front Left side Right side N.O. Main aux. aux. aux. contacts Main Positive ly Guided Contact s Front aux. Left side aux. Right side aux. Open Open Open Open Open Open Open Open Open Open Open Open Open Open Open Open If the accessory is a pneumatic timer or latch, there is no positive guidance; the accessory contacts are independent. Defined in IEC 947-5-1 annex L. Positive guidance is a relationship between contacts of opposite types (i.e., N.O. and N.C.). 199 Bulletin 700S-CF Industrial Relays Approximate Dimensions Approximate Dimensions are shown in millimeters (inches). Approximate Dimensions are not intended for manufacturing purposes. c2 c1 c AC Safety Control Relays a 45 (1-25/32) b 81 (3-3/16) c 119.5 (4-3/4) c1 114.5 (4-43/64) c2 6 (1/4) d 2 - 4.5 (2 - 3/16) d1 60 (2-23/64) d2 35 (1-25/64) Cat. No. 700S-CF DC Safety Control Relays a 45 (1-25/32) b 81 (3-3/16) c 145.5 (5-49/64) c1 140.5 (5-37/64) c2 6 (1/4) d 2 - 4.5 (2 -3/16) d1 60 (2-23/64) d2 35 (1-25/64) Cat. No. 700S-CF Mounting Positions Mounting Position AC Safety Control Relays DC Safety Control Relays Safety Relay Circuit With 5 Safety Outputs Use for E-stop control. E-stop will work properly if any one fault occurs (a fault could be one welded contact or one undesired open connection such as a loose wire). * High output switching capability and long contact life. * Circuit complies with EN 954 categories 1, 2, 3, 4 * Prevents restart of the 5 safety outputs if there is a single fault anywhere in the system. Use (3) 700S-CF relays and this diagram to construct the circuit, or contact your local Allen Bradley sales office for pre-assembled module * 200 Bulletin 700S-CF Industrial Relays Approximate Dimensions, Continued . Basic Circuit (1) Output Circuit (3 Relays, 9 Terminal Blocks) 13 14 A1 A2 2 4 5 7 8 9 10 11 700S-CF 620* C 13 14 700-Z 33 34 Included in Factory Wired Units 21 22 21 22 A1 A2 1 3 5 7 8 9 10 11 700S-CF 350* C 61 62 43 44 A1 A2 4 6 7 8 9 10 11 700S-CF 620* C 13 14 33 34 21 22 33 34 LOAD 1 (5) Output Circuit (3 Relays, 17 Terminal Blocks) 14 15 16 17 43 18 44 19 51 52 20 43 44 21 LOAD 2 LOAD 3 53 22 54 23 61 62 24 53 54 25 73 26 74 27 71 72 28 63 64 29 LOAD 4 LOAD 5 83 84 81 82 73 74 Numbers shown are the line numbers where the contacts for this relay appear. 201 |
Price & Availability of 700S-CF440XC
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |