![]() |
|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
J2R0015-41-31 REED SWITCH ORD9215 General Purpose Miniature n GENERAL DESCRIPTION The ORD9215 is a small single-contact reed switch designed for general control of mediumlevel loads less than 100 V. The contacts are sealed within the glass tube with inert gas to maintain contact reliability. n FEATURES (1) Reed contacts are hermetically sealed within a glass tube with inert gas and do not receive any influence from the external atmospheric environment. (2) Quick response (3) The structure comprises the operating parts and electrical circuits arranged coaxially. Reed switches are suited to applications in radio frequency operation. (4) Reed switches are compact and light weight. (5) Superior corrosion resistance and wear resistance of the contacts assures stable switching operation and long life. (6) With a permanent magnet installed, reed switches economically and easily become proximity switches. n EXTERNAL DIMENSIONS (Unit: mm) f0.5 MAX f2.8 MAX 44.1 0.5 n APPLICATIONS l Control equipment l Communication equipment l Measurement equipment l Household appliances l ORD9215 n ELECTRICAL CHARACTERISTICS Parameter Pull-in Value (PI) Drop-out Value (DO) Contact resistance (CR) Breakdown voltage Insulation resistance Electrostatic capacitance Contact rating Maximum switching voltage Maximum switching current Maximum carry current Rated value 10 50 4min 100max 150min 109min 0.3max 10 100 DC AC Unit AT AT mW V VDC W pF VA V A A 0.5 1.0 99.9 (Measurement length: 32mm) Cumulative frequency percent (%) AT 50 99 95 90 80 70 60 50 40 30 20 10 5 1 0.1 40 60 80 100 mW Drop-out Value 40 30 20 10 0 10 20 30 Pull-in Value 40 50 AT Contact resistance ORD9215 l (3) Breakdown voltage (4) Insulation resistance 99.9 Cumulative frequency percent (%) DC 100V 99 95 90 80 70 60 50 40 30 20 10 5 1 0.1 10 10 11 12 13 14 DC V 400 Breakdown voltage 300 200 100 0 10 20 30 Pull-in Value 40 50 AT 10 10 10 10 W Insulation resistance (5) Electrostatic capacitance 1MHz pF Electrostatic capacitance 0.4 0.3 0.2 0.1 0 10 20 30 Pull-in Value 40 50 AT l ORD9215 n OPERATING CHARACTERISTICS Parameter Operate time Bounce time Release time Resonant frequency Maximum operating frequency Rated value 0.4max 0.4max 0.05max 3700 400 500 Unit ms ms ms Hz Hz (1) Operate time (25Hz: 100AT energized) (2) Bounce time (25Hz: 100AT energized) 99.9 ms 0.5 Cumulative frequency percent 99 95 90 80 70 60 50 40 30 20 10 5 1 0.4 Operate time 0.3 0.2 0.1 0 10 20 30 Pull-in Value 40 50 0.1 AT 0 0.1 0.2 0.3 0.4 ms Bounce time (3) Release time (4) Resonant frequency 99.9 99 Cumulative frequency percent (25Hz: 100AT energized) ms 15 95 90 80 70 60 50 40 30 20 10 5 1 0.1 Release time 10 5 0 10 20 30 40 50 AT 3400 3700 4000 Hz Drop-out Value Resonant frequency ORD9215 l n MECHANICAL CHARACTERISTICS (1) Lead tensile test (static load) 2.27kg-10sec (2) Lead tensile strength 99.9 AT 60 Cumulative frequency percent (%) 99 95 90 80 70 60 50 40 30 20 10 5 1 0.1 0 2 4 6 8 10kg Breaking load Pull-in Value * Drop-out Value 50 40 PI 30 20 DO 10 0 Contact resistance 80 CR 60 40 Before test After test n ENVIRONMENTAL CHARACTERISTICS (1) Temperature characteristics 40 CR 30 Rate of change percent 20 DO 10 PI 0 10 20 30 40 20 0 20 40 Temperature 60 80 100 120 l ORD9215 (2) Temperature cycle (-55 AT 60 Pull-in Value * Drop-out Value Pull-in Value * Drop-out Value +125 ) (3) Temperature and humidity cycle -10 80 AT 60 +65 98 50 50 40 PI 40 PI 30 30 20 DO 20 DO 10 10 0 Contact resistance Contact resistance mW 100 CR 0 mW 100 CR 80 80 60 Before test After test 60 Before test After test (4) High temperature storage test (+125 -500H) AT 60 Pull-in Value * Drop-out Value Pull-in Value * Drop-out Value (5) Low temperature storage test -500H) AT 60 50 50 40 PI 40 PI 30 30 20 DO 20 DO 10 10 0 Contact resistance Contact resistance mW 100 CR 0 mW 100 CR 80 80 60 Before test After test 60 Before test After test ORD9215 l (6) Shock test 1) Electrical characteristics (30G: 11ms) AT 60 Pull-in Value * Drop-out Value 2) Misoperation area (open close) G 1500 50 40 PI Acceleration 30 1000 Misoperation area 20 DO 10 500 0 Contact resistance mW 100 CR 80 0 10 20 30 40 50 60 AT Pull-in Value 60 Before test After test (7) Vibration test (20G: 10 1000Hz) AT 60 Pull-in Value * Drop-out Value 50 40 PI 30 20 DO 10 0 Contact resistance mW 100 CR 80 60 Before test After test l ORD9215 n LIFE EXPECTANCY DATA: ORD9215 % 99.9 90 70 50 30 10 5 No failure 5mA 1mA 100mA Load conditions Voltage: 5VDC Current: 100mA 1mA , 5mA Load: Resistive load Cumulative failure rate 1 0.1 0 23 5 7 105 23 5 7 106 23 5 7 107 23 5 7 108 Number of operations * Arrow indicates number of operations where test was completed. % 99.9 90 70 50 30 10 5 No failure Load conditions Voltage: 12 VDC Current: 5mA, 10mA, 100mA Load: Resistive load Cumulative failure rate 100mA 10mA 5mA 1 0.1 0 23 5 7 105 23 5 7 106 23 5 7 107 23 5 7 108 Number of operations * Arrow indicates number of operations where test was completed. Cumulative failure rate 200mA 100mA % 99.9 90 70 50 30 10 5 400mA 100mA Load conditions Voltage: 24 VDC Current: 100mA, 200mA, 400mA Load: Resistive load 200mA 1 0.1 0 23 5 7 105 23 5 7 106 23 5 7 107 23 5 7 108 Number of operations |
Price & Availability of ORD9215
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |