 CORCOM Product Guide High Performance RFI Power Line Filters for Medical Equipment
HT Series
HT6
UL Recognized CSA Certified VDE Approved
HT7
HT3
HT1
HT Series
The HT series power line filters provide superior commonmode and premium differential-mode attenuation to RFI noise on the frequency range from 10kHz to 30MHz, for IEC 60601 and UL2601 patient-connected equipment, as well as all other electronic equipment that cannot tolerate leakage current. They are a size- and cost-effective solution to the problem of meeting both medical leakage current limits and conducted emissions limits in equipment with high noise sources (such as switching power supplies). HT series filters can meet the following Conducted Emissions standards: * European Normalized Standards based on EN55022, Level A (in many cases, Level B also). * FCC Part 15, Computing Devices, Class B. * FCC Part 18, ISM Equipment, Industrial and Consumer. Note: When using the models with an IEC connector, remember that the leakage current of the companion line cord, GA400, is more significant than that of the filter which may disqualify this line cord from use in patient care applications. For more information on UL2601, see Appendix C.
Specifications
Maximum leakage current,each line-to-ground @ 120 VAC 60 Hz: @ 250 VAC 50 Hz: Hipot rating (one minute): line-to-ground line-to-line Operating frequency: Rated voltage (max.): Minimum insertion loss in dB: Line-to-ground in 50 ohm circuit Current Frequency-MHz Rating .01 .02 .05 .08 .15 .5 1 2 3A 6A 10A 15A 22 32 16 23 9 15 49 36 - 49 46 32 41 46 41 24 30 36 42 18 22 27 41 40 33 34 34 30 26 22 22 5 10 20 30 22 15 11 12 12 9 12 12 12 6 8 5 12 2 8 2 2A 5A 1500 VAC 1450 VDC 50/60 Hz 250 VAC
Line-to-line in 50 ohm circuit Frequency-MHz Current Rating .01 .02 .05 .08 .15 .5 1 2 3A 6A 10A 15A 31 41 78 12 16 30 - 61 70 14 45 51 70 17 32 52 70 15 10 51 70 65 70 70 70 65 65 70 70 5 10 20 30 48 55 65 70 40 47 55 70 32 37 40 65 32 37 35 55
Electrical Schematics
3 & 6 Amp
LINE LOAD
10 Amp
LINE LOAD
15 Amp
LINE LOAD
Resistor location for reference only.
70
Catalog 1654001 Revised 05-07 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. USA Cust. Svc.: 1-800-468-2023 CORCOM Prods: 1-847-680-7400 Germany: 49-89-6089-0 www.corcom.com www.tycoelectronics.com
CORCOM Product Guide High Performance RFI Power Line Filters for Medical Equipment (Continued)
HT Series
Case Styles
HT1 (3, 6 and 10 Amp)
E
B
0.235 R 5.96
1.575 40.01 0.910 23.1
RFI Power Line Filters
0.157 Dia. 1.295 HT7 & HT7M (with metric insert) 3.98 32.89
D
B
E C A
Tapped insert No. 6-32 x 1/4 (2) - T7 No. M-3 x 5 (2) - T7M
D A
C
Typical dimensions: Terminals: .250 [6.35] (5) Holes: .07 [1.8 ] Dia.(4) Slot: .07 x .16 [1.8 x 4.1 ] Mounting holes: .188 [4.78 ] Dia. (2)
Recommended Panel Cutout
0.235 R 5.96 1.575 40.01 0.910 23.1 0.157 Dia. 3.98 1.295 32.89
HT1 (15 Amp)
EDB
Panel Cutout (back mount) Tolerance .005 [0.13]
2.00.01 50.80.25
Case BDimensions
C
D
A Typical dimensions: Terminals: .250 [6.35] (5) Holes: .07 [1.8 ] Dia.(4) Slot: .07 x .16 [1.8 x 4.1 ] Mounting holes: .203 x .156 [5.16 x 3.96 ] Dia. (4)
Part No.
E C
A (max)
B (max) 2.15 54.6 2.15 54.6 2.25 57.2 2.27 57.7 2.27 57.7 3.12 79.2 3.12 79.2
C (max) 1.81A 46.0 1.81 46.0 1.78 45.2 1.8 45.7 1.8 45.7 2.18 55.4 2.18 55.4
D
.015 .38
E (max) 3.38 85.9 3.38 85.9 0.63 16.0 4.47 113.5 4.47 113.5 3.96 100.6 3.96 100.6
HT3
Blue Blue Green/Yellow Brown Brown
B
A D E
Typical dimensions: Wire leads: 4.0 [101.6 ] Min.
C
Mounting holes: .188 [4.78 ] Dia. (2)
HT6
3.56 90.4 2.55 3EHT3, 6EHT3 64.8 3EHT7, 3EHT7M, 3.52 6EHT7, 6EHT7M 89.4 4.69 10EHT1 119.1 3.69 10EHT3 93.7 5.45 15EHT1 138.4 5.95 15EHT6 151.1 3EHT1, 6EHT1
2.938 74.63 2.938 74.63 1.575 40.01 4.063 103.2 4.063 103.2 3.5 88.9 3.5 88.9
.02 [.5]
EDB
Part Numbers
6EHT1 6EHT3 6EHT7 6EHT7M Line Cord No. 10EHT1 10EHT3 15EHT1 15EHT6 GA400
2.00.01 50.80.25
A
Typical dimensions: Terminals: No. 8-32 (5) Torque: 182 in.lb
C
Mounting holes: .203 x .156 [5.16 x 3.96 ] Dia. (4)
71/2 foot, 3-conductor line cord to mate with T7 models
71
Catalog 1654001 Revised 05-07 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. USA Cust. Svc.: 1-800-468-2023 CORCOM Prods: 1-847-680-7400 Germany: 49-89-6089-0 www.corcom.com www.tycoelectronics.com