 SURFACE MOUNT SCHOTTKY BARRIER RECTIFIER
VOLTAGE RANGE 20 to 200 Volts CURRENT 2.0 Ampere
FEATURES
* * * * * Ideal for surface mounted applications Low leakage current Metallurgically bonded construction Mounting position: Any Weight: 0.098 gram
FM220L THRU FM2200L
MECHANICAL DA TA
* Epoxy: Device has UL flammability classification 94V-O
0.083 (2.11) 0.077 (1.96) 0.155 (3.94) 0.130 (3.30)
SMBL
0.180 (4.57) 0.160 (4.06)
0.012 (0.305) 0.006 (0.152) 0.085 (2.15) 0.061 (1.55)
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
Ratings at 25 o C ambient temperature unless otherwise specified. Single phase, half wave, 60 Hz, resistive or inductive load. For capacitive load, derate current by 20%.
0.060 (1.52) 0.030 (0.76)
0.008 (0.203) 0.004 (0.102)
0.220 (5.59) 0.205 (5.21)
Dimensions in inches and (millimeters) MAXIMUM RATINGS (@ TA=25 OC unless otherwise noted) RATINGS Maximum Recurrent Peak Reverse Voltage Maximum RMS Voltage Maximum DC Blocking Voltage Maximum Average Forward Rectified Current at Ambient Temperature Peak Forward Surge Current 8.3 ms single half sine-wave superimposed on rated load (JEDEC method) Typical Thermal Resistance (Note 1) Typical Thermal Resistance (Note 1) Typical Junction Capacitance (Note 2) Operating Temperature Range Storage Temperature Range SYMBOL FM220L FM230L FM240L FM250L FM260L FM280L FM2100L VRRM VRMS VDC IO I FSM RqJA RqJL CJ TJ T STG 20 14 20 30 21 30 40 28 40 50 35 50 60 42 60 2.0 60 75 17 130 150 -55 to + 150 80 56 80 100 70 100
FM2150L FM2200L UNITS
150 105 150
200 140 200
Volts Volts Volts Amps Amps
0 0
C/W C/W pF
0 0
C C
ELECTRICAL CHARACTERISTICS (@TA=25 OC unless otherwise noted) CHARACTERISTICS Maximum Instantaneous Forward Voltage at 2.0A DC Maximum Average Reverse Current at Rated DC Blocking Voltage @T A = 25 o C @T A = 100 o C SYMBOL FM220L FM230L FM240L FM250L FM260L FM280L FM2100L VF IR .55 .70 0.2 2
FM2150L FM2200L UNITS
.85
Volts mA mA 2006-12
NOTES : 1. Thermal Resistance :Mounted on PCB. 2. Measured at 1 MHz and applied reverse voltage of 4.0 volts. 3. "Fully ROHS compliant","100% Sn plating (Pb-free)".
RATING AND CHARACTERISTICS CURVES ( FM220L THRU FM2200L )
INSTANTANEOUS FORWARD CURRENT, (mA)
AVERAGE FORWARD CURRENT, (A)
2.0
100 10 1.0 0.1 0.01 T = 75 OC A 0.001 0 20 40 60 80
FM220L~FM240L FM250L~FM260L FM280L~FM2200L TA = 100 OC
1.5
FM2
FM 22 0L
~F
50L
~F M
1.0
220
0.5
Single Phase Half Wave 60Hz Resistive or Inductive Load 0.375" (9.5mm) Lead Length
M2 40 L
0L
TA = 25 OC
0
0
25
50
75
100
125
O
150
175
100
120
140
AMBIENT TEMPERATURE, ( C)
PERCENT OF RATED PEAK REVERSE VOLTAGE, (%)
INSTANTANEOUS REVERSE CURRENT, (A)
10
FM220L~FM240L
CJ, JUNCTION CAPACITANCE, (pF)
20
FIG.1 TYPICAL FORWARD CURRENT DERATING CURVE
400 200 100 80 60 40 20 10
FIG.2 TYPICAL REVERSE CHARACTERISTICS
TJ = 25 OC
1.0
FM280L~FM2200L FM250L~FM260L TJ = 25 OC Pulse width=300mS 1% Duty Cycle
0.1
0.1
0.3
0.5
0.7
0.9
1.1
1.3
1.5
1.7
1.9 2.1
0.1
0.4
1.0
4
10
40 80
INSTANTANEOUS FORWARD VOLTAGE, (V)
REVERSE VOLTAGE, (V)
FIG.3 TYPICAL INSTANTANEOUS FORWARD CHARACTERISTICS
PEAK FORWARD SURGE CURRENT, (A)
FIG.4 TYPICAL JUNCTION CAPACITANCE
60 50 40 30 20 10 1
8.3mS Single Half Sine-Wave JEDEC Method
2
4
6
8 10
20
40
80 100
NUMBER OF CYCLES AT 60Hz
FIG.5 MAXIMUM NON-REPETITIVE FORWARD SURGE CURRENT
Mounting Pad Layout
0.106 MAX. (2.69 MAX.)
0.083MIN. ( 2.10 MIN.) 0.050 MAX. (1.27 MAX.) 0.220
(5.58) REF
Dimensions in inches and (millimeters)
DISCLAIMER NOTICE
Rectron Inc reserves the right to make changes without notice to any product specification herein, to make corrections, modifications, enhancements or other changes. Rectron Inc or anyone on its behalf assumes no responsibility or liability for any errors or inaccuracies. Data sheet specifications and its information contained are intended to provide a product description only. "Typical" parameters which may be included on RECTRON data sheets and/ or specifications can and do vary in different applications and actual performance may vary over time. Rectron Inc does not assume any liability arising out of the application or use of any product or circuit. Rectron products are not designed, intended or authorized for use in medical, life-saving implant or other applications intended for life-sustaining or other related applications where a failure or malfunction of component or circuitry may directly or indirectly cause injury or threaten a life without expressed written approval of Rectron Inc. Customers using or selling Rectron components for use in such applications do so at their own risk and shall agree to fully indemnify Rectron Inc and its subsidiaries harmless against all claims, damages and expenditures.


▲Up To Search▲   

 
Price & Availability of FM280L

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X