 DC/DC Converters
TES 2M Series, 2 Watt
Features Ultracompact SMD-package I/O isolation 4000 VACrms Reinforced insulation rated for working
voltages up to 300 VAC
CB
Scheme
UL 60950-1 UL 60601-1
Industrial & medical safety approval Operating temp. range -40C to +71C Qualified for leadfree reflow solder
process
Available in tape & reel package
The TES 2M series is a new range of ultra-compact 2W DC/DC-converters providing a high I/O-isolation voltage of 4000 VAC. With a reinforced I/O-isolation system this product is an economical solution for many applications in instrumentation, industrial controls, medical equipment and everywhere where supplementaryor reinforced insulation is required to meet requested safety standards. With a new package design these converters are qualified for the higher solder temperature profiles in leadfree solder processes. For automated SMD production lines the devices can be supplied in tape & reel package. Full SMD-design with exclusive use of ceramic capacitors ensure a very high reliability and a long product lifetime.
Models
Ordercode TES 2-0511M TES 2-0512M TES 2-0513M TES 2-0522M TES 2-0523M TES 2-1211M TES 2-1212M TES 2-1213M TES 2-1222M TES 2-1223M TES 2-2411M TES 2-2412M TES 2-2413M TES 2-2422M TES 2-2423M 24 VDC 10% (nominal 24 VDC) 12.0 VDC 10% (nominal 12 VDC) 5.0 VDC 10% (nominal 05 VDC) Input voltage range Output voltage 5 VDC 12 VDC 15 VDC 12 VDC 15 VDC 5 VDC 12 VDC 15 VDC 12 VDC 15 VDC 5 VDC 12 VDC 15 VDC 12 VDC 15 VDC Output current max. 400 mA 165 mA 133 mA 83 mA 66 mA 400 mA 165 mA 133 mA 83 mA 66 mA 400 mA 165 mA 133 mA 83 mA 66 mA Efficiency typ. 66 % 66 % 66 % 72 % 73 % 66 % 66 % 66 % 74 % 75 % 66 % 66 % 66 % 74 % 75 %
http://www.tracopower.com
Page 1 of 3
DC/DC Converters
TES 2M Series Input Specifications
Input current no load / full load 5 Vin models: 60 mA / 600 mA typ. 12 Vin models: 30 mA / 250 mA typ. 24 Vin models: 15 mA / 125 mA typ. 0.3 A max. 5 Vin models: 1.0 A 12 Vin models: 0.5 A 24 Vin models: 0.2 A 5 Vin models: 9 V max. 12 Vin models: 18 V max. 24 Vin models: 30 V max. internal capacitors 4 % 1 % max. 1.2 % / 1 % change of Vin 10 % max. 12 % max. for 5 Vout models. 150 mVpk-pk max. 0.02 %/K 0.5 sec. max. 2 % of rated max current. single output models: 330 F max. dual output models: 100 F max. (each output) - Operating - Storage - Casing -40C to +71C -55C to +125C +90C max. 2.5 %/K above 60C 95 % rel. H max. >2.0 Mio h @ 25C 4000 VACrms 6000 Vpk 2 A max. 20 pF max. (at 100KHz, 1V) >10 Gohm (at 500VDC) 50 - 100 kHz (PFM) IEC/EN 60950-1, UL 60950-1 CSA C22.2 No. 60950-1-03 IEC/EN 60601-1, UL 60601-1, CSA C22.2 No. 601-1 for medical electrical for information technology - CB test report for medical electrical for information technology - CSA certificate equipment equipment equipment equipment www.tracopower.com/products/thi2m-csa60601.pdf www.tracopower.com/products/thi2m-csa60950.pdf www.tracopower.com/products/thi2m-cb60601.pdf www.tracopower.com/products/thi2m-cb60950.pdf - Input/Output - Input/Output - Input variation - Load variation 20 - 100 %
2 Watt
Reverse voltage protection Recommended input fuse (slow blow)
Surge voltage (1 sec. max.)
Input filter
Output Specifications
Voltage set accuracy Voltage balance (dual output models) Regulation
Ripple and noise (20 MHz Bandwidth) Temperature coefficient Short circuit protection Minimum load Capacitive load
General Specifications
Temperature ranges
Derating Humidity (non condensing) Reliability, calculated MTBF (MIL-HDBK-217F ground benign) Isolation voltage (50Hz, 60sec) - Input/Output Isolation test voltage (1 sec.) Leakage current (at 240VAC, 60Hz) Isolation capacity Isolation resistance Switching frequency Safety standards
Safety approvals
All specifications valid at nominal input voltage, full load and +25C after warm-up time unless otherwise stated. http://www.tracopower.com Page 2 of 3
DC/DC Converters
TES 2M Series General Specifications
Casing material Weight Lead-free reflow solder process Moisture sensitivity level (MSL) plastic 3.8 g (0.13oz) as per IPC J-STD-020D as per IPC J-STD-033B MSL report level 2
2 Watt
Outline Dimensions
24.0 (0.94)
0.25 (0.01)
9.0 (0.35)
0 - 4
1.0 (0.04)
0.15
16 top view
10
9 13.7 (0.54) 18.1 (0.71)
Pin-Out
Pin 1 7 8 9 10
2.54 (0.10)
Single -Vin (GND) No con. No con. +Vout -Vout +Vin
Dual -Vin (GND) No con. Common +Vout -Vout +Vin
1
7
8
3.11 (0.12)
15.24 (0.60)
16
Solder Pad Dimensions
1.4 (0.055) min.
(0.11)
13.7 (0.54)
2.8
3.11 (0.12)
15.24 (0.60)
2.54 (0.10)
Dimensions in [mm], () = Inch Tolerances 0.25 (0.01) Pin pitch tolerances 0.05 (0.002)
Specifications can be changed any time without notice.
Rev. 04/09
Jenatschstrasse 1 * CH-8002 Zurich * Switzerland Tel. +41 43 311 45 11 * Fax +41 43 311 45 45 * info@traco.ch * www.tracopower.com
(0.11)
2.8
Page 3 of 3


▲Up To Search▲   

 
Price & Availability of TES2-0511M

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X