![]() |
|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
AC-DC 120 Watts AMM120 Series * * * * * * * Energy Star Level V 24 V xppower.com CEC 2008 & EISA 2007 Compliant Worldwide Medical Approvals Small Size/High Power Density Class I and Class II Versions Operating Temperature up to +60 C Locking Output Connector Specification Input Input Voltage Input Frequency Input Current * 90-264 VAC * 47-63 Hz * 1.6 A rms at 115 VAC, 0.8 A rms at 230 VAC Inrush Current * 60 A at 115 VAC, 120 A at 230 VAC, cold start +25 C Power Factor * 0.98 typical Earth Leakage Current * 90 A max at 115 VAC/60 Hz, (Class I Versions) 150 A max at 230 VAC/50 Hz Input Protection * Internal 3 A fuse in live and neutral lines General Efficiency Isolation * 85% typical * 4000 VAC Input to Output 1500 VAC Input to Ground (Class I only) 500 VAC Output to Ground (Class I only) * 40-120 kHz variable * 3.7 W/In3 * >175 kHrs per MIL-HDBK-217F Switching Frequency Power Density MTBF Environmental Operating Temperature * 0 C to +60 C, derate from 100% power at +40 C to 50% power at +60 C Cooling * Convection-cooled Operating Humidity * 10-95% RH, non-condensing Storage Temperature * -20 C to +80 C Operating Altitude * 3000 m Shock * 30 g, 10 ms on 3 axes Vibration * 5-100 Hz, 2.31 m/s2, 20 mins, 3 axes Output 12 to 48 VDC Not user-adjustable 2 % No minimum load required 2 s max at 115 VAC <80 ms at 115 VAC 15 ms minimum at full load & 115 VAC 0.5% maximum Total regulation <5% 4% max. deviation, recovery to within 1% in 500 s for a 25% load change Ripple & Noise * 2% max pk-pk (see note 1) Overvoltage Protection * 110-140% Vnom, recycle input to reset Overtemperature * Unit shuts down, recycle input to reset Protection Overload Protection * 110-150%, auto recovery Short Circuit Protection * Trip and restart (Hiccup mode) Temperature * 0.04%/C Coefficient Output Voltage Output Voltage Trim Initial Set Accuracy Minimum Load Start Up Delay Start Up Rise Time Hold Up Time Line Regulation Load Regulation Transient Response * * * * * * * * * * EMC & Safety Emissions Harmonic Currents Voltage Flicker ESD Immunity Radiated Immunity EFT/Burst Surge Conducted Immunity Magnetic Field Dips & Interruptions * EN55011/FCC/VCCI, Class B conducted EN55011/FCC/VCCI, Class B radiated * EN61000-3-2 * EN61000-3-3 * EN61000-4-2, level 3 Perf Criteria A * EN61000-4-3, level 2 Perf Criteria A * EN61000-4-4, level 3 Perf Criteria A * EN61000-4-5, level 3 Perf Criteria A * EN61000-4-6, 3 V Perf Criteria A * EN61000-4-8, 3 A/m Perf Criteria A * EN61000-4-11, 70% UT for 10 ms, 40% UT for 100 ms, <5% UT for 5000 ms Perf Criteria A, B, B (Perf Criteria A, A, B with 70% load) * EN60601-1, UL60601-1, CSA22.2 No. 601-1 per cUL, CE Mark Safety Approvals AC-DC AMM120 Models and Ratings Output Power 96 W 105 W 120 W 120 W 120 W 120 W 120 W 120 W 120 W Notes 1. 2. 3. 4. Ripple and noise measured at 20 MHz bandwidth with a 10 F tantalum and 0.1 F ceramic cap connected at the measurement point. Total regulation includes initial set accuracy, line and load regulation. For class II versions, add `-C2' to model number e.g. AMM120PS24-C2. For optional barrel jack connector add suffix `B1' to model number e.g. AMM120PS24C2B1. Output Voltage 12 V 15 V 18 V 19 V 20 V 24 V 30 V 36 V 48 V Output Current 8.00 A 7.00 A 6.67 A 6.32 A 6.00 A 5.00 A 4.00 A 3.34 A 2.50 A Total Regulation(2) 5% 5% 5% 5% 5% 5% 5% 5% 5% Model Number(3, 4) AMM120PS12 AMM120PS15 AMM120PS18 AMM120PS19 AMM120PS20 AMM120PS24 AMM120PS30 AMM120PS36 AMM120PS48 Mechanical Details Cable length approx 48" (1220mm) 13 2 4 1.72 (43.7) Power On Indicator Pin 1 2 3 4 Function Return Output+ Return Output+ Rubber foot (4 places.) 6.30 (160.0) 3.00 (76.2) Optional Barrel Jack Connector 0.433 (11.0) 0.217 (5.5) 0.02 (0.5) 0.083 (2.1) 0.413 (10.5) AC Input IEC 320-C14 Inlet - For Class I version IEC 320-C18 Inlet - For Class II version Notes 1. Dimensions shown in inches (mm). Tolerance is 0.02 (0.5) maximum, except output cable length. 2. Maximum load per pin on output connector is 5 A. 3. Output connector is KYCON KPP-4P locking type. For mating half, use KYCON KPJ-4S-S or equivalent. 4. For Class I versions shell is connected to ground. For Class II versions shell is capacitively coupled to input. 5. Weight 1.72 lbs (780 g). 01-Dec-08 |
Price & Availability of AMM120PS12
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |