Totalizers electromechanic Impulse counters adding, modular system Display 6- or 8-digits, with/without reset button F 304, F 314, F 324, F 364 Features - Impulse counter - Adding - Display 6- or 8-digits - With or without reset button - Socket box F 304 - Socket box Technical data - electrical ratings Voltage supply 24/110 VAC 10 % (50/60 Hz) 230 VAC +6/-10 % (50/60 Hz) 24 VDC 10 % <48 % 50 / 60 Hz 2.2 W, 2.4 VA 1:1 100 million impulses Protection class II Overvoltage category II Pollution degree 2 DIN EN 61000-6-4 DIN EN 61000-6-2 CE conform Subject to modification in technic and design. Errors and omissions excepted. 2/12/2008 Ripple residue Nominal frequency Power consumption Pulse ratio Service life Standard DIN EN 61010-1 F 314 - Front panel with screw mount Emitted interference Interference immunity Approval Technical data - mechanical design Display Digit height Count mode Step-by-step switching Reset Operating temperature Storing temperature Relative humidity F 324 - Front panel with spring clip Protection DIN EN 60529 E-connection Weight approx. Material White numbers on black 4.5 mm 1 impulse = 1 count Adding in 2 half steps Manual by reset button 0...+60 C -20...+70 C 80 % non-condensing IP 41 Soldering pins (flat) 100 g Housing: Noryl PPO, black 1 www.baumerivo.com Impulse counters adding, modular system Display 6- or 8-digits, with/without reset button Totalizers electromechanic F 304, F 314, F 324, F 364 Technical data - mechanical design F 304 Number of digits Measuring range Housing type Mounting Dimensions W x H x L Cutout dimensions Installation depth F 314 Number of digits Measuring range Housing type Mounting Dimensions W x H x L Cutout dimensions Installation depth F 324 Number of digits Measuring range Housing type Mounting Dimensions W x H x L Cutout dimensions Installation depth F 364 Number of digits Measuring range Housing type Mounting Dimensions W x H x L Cutout dimensions Installation depth 6-digits with reset button 999 999 Built-in housing Front panel with 4 screws 66.5 x 37 x 75 mm 51 x 26 mm 72 mm 6-digits with reset button 8-digits without reset button 999 999 and 99 999 999 Built-in housing Front panel with spring clips 53.2 x 28.2 x 61 mm 51 x 26 mm 77.5 mm 6-digits with reset button 8-digits without reset button 999 999 and 99 999 999 Built-in housing Front panel with 2 screws 60 x 50 x 61 mm 51 x 26 mm 77.5 mm 6-digits with reset button 8-digits without reset button 999 999 and 99 999 999 Socket box Socket box 50 x 25 x 85.8 mm 50 x 25 mm 85.9 mm Trigger level Max. counting speed 10 pulses/s Voltage Power Min. pulse duration Min. pulse interval Switch on time (at 25 C) Voltage Power Min. pulse duration Min. pulse interval Switch on time (at 25 C) Accessories Front panels for F 304 Z 100.01A Front panel with transparent protective cover, for socket box 50 x 25 mm Front frame with cylinder lock provided on transparent cover Front frame, insertion cutout 50 x 25 mm 24/110 VAC 10 % 230 VAC +6/-10 % 2.4 VA 50 ms 50 ms 100 % 24 VDC 10 % 2.2 W 25 ms 25 ms 100 % Connection diagram 4 3 -(+) Voltage +(-) Encoder Max. counting speed 20 pulses/s Front frames for F 304 Subject to modification in technic and design. Errors and omissions excepted. 2/12/2008 Z 105.02A Z 107.01A 2 www.baumerivo.com Totalizers electromechanic Impulse counters adding, modular system Display 6- or 8-digits, with/without reset button F 304, F 314, F 324, F 364 Part number Socket box F 304. Display C 8-digits 99 999 999 B 6-digits 999 999 A3 A5 A8 A9 800B 650A Voltage 24 VDC 24 VAC 110 VAC 230 VAC 800B 650A A3 A5 A8 A9 Front panel with screw mount F 314. Display C 8-digits 99 999 999 B 6-digits 999 999 Voltage 24 VDC 24 VAC 110 VAC 230 VAC Reset Without reset button With reset button Reset Without reset button With reset button Front panel with spring clips mount F 324. Display C 8-digits 99 999 999 B 6-digits 999 999 A3 A5 A8 A9 800B 650A Voltage 24 VDC 24 VAC 110 VAC 230 VAC Front panel with screw mount F 364. 650A B Display B 6-digits 999 999 A3 A5 A8 A9 Voltage 24 VDC 24 VAC 110 VAC 230 VAC 3 www.baumerivo.com 2/12/2008 Subject to modification in technic and design. Errors and omissions excepted. Reset Without reset button With reset button Reset 650A With reset button Impulse counters adding, modular system Display 6- or 8-digits, with/without reset button Totalizers electromechanic F 304, F 314, F 324, F 364 Dimensions F 304 with reset button, 6-digits 50 F 304 without reset button, 8-digits 50 25 18.5 67.4 25 8 18.5 67.4 F 314 with reset button, 6-digits 12.5 30 50 38 -0.15 6 8 F 314 without reset button, 8-digits 12.5 25 30 50 38 -0.15 6 25 5 50 60 16.5 61 3 5 50 60 16.5 61 3 F 324 with reset button, 6-digits 1.6 53.2 28.2 8 F 324 without reset button, 8-digits 1.6 25 53.2 28.2 25 1.6 50 16.5 6 61 3 1.6 50 6 16.5 61 3 F 364 with reset button, 6-digits Subject to modification in technic and design. Errors and omissions excepted. 66.5 49.8 6.2 8.35 37 29 4 8 24.6 4 58.5 11 61 3 4 www.baumerivo.com 2/12/2008 |
Price & Availability of F304800BA3B
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |