 D100VHI Series
Miniature, 1W SIP Ultra-High Isolation DC/DC Converters
Electrical Specifications
Specifications typical @ +25C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Key Features:
* 1W Output Power * 6.0 kVDC Isolation * Miniature SIP Case * Single & Dual Outputs * Miniature SIP Case * 12 Standard Models * 2.0 MH MTBF * Industry Standard Pin-Out
Input
Parameter Input Voltage Range Input Filter Reverse Polarity Input Current Conditions 5 VDC Input 12 VDC Input Min. 4.5 10.8 Typ. 5.0 12.0 Max. 5.5 13.2 0.3 Conditions Dual Output , Balanced Loads For Vin Change of 1% Min. Typ. 1.0 0.1 1.2 100 Over Line, Load & Temp. 120 0.01 Momentary (0.5 Sec.) Conditions 60 Seconds Flash Tested For 1 Sec 500 VDC 100 kHz, 1V 50 Conditions Ambient Case Min. -40 -40 -40 Free Air Convection RH, Non-condensing 95 % Min. 6,000 6,600 10 15 80 Typ. +25 20 100 Max. +70 +90 +125 Typ. Max. Units VDC VDC G pF kHz Units C C C 0.02 Max. 3.0 1.0 1.5 150 200 5 Units VDC
Internal Capacitor A Units % % % mV P - P mV P - P mV rms % %/C
Output
Parameter Output Voltage Accuracy Output Voltage Balance Line Regulation Load Regulation (Note 1) Ripple & Noise (20 MHz) (Note 2) Ripple & Noise (20 MHz) Ripple & Noise (20 MHz) Output Power Protection Temperature Coefficient Output Short Circuit
See Model Selection Guide
RoHS Compliant
General
Parameter Isolation Voltage Isolation Test Voltage Isolation Resistance Isolation Capacitance Switching Frequency
Environmental
Parameter Operating Temperature Range Operating Temperature Range Storage Temperature Range
MicroPower Direct
292 Page Street Suite D Stoughton, MA 02072 USA T: (781) 344-8226 F: (781) 344-8481 E: sales@micropowerdirect.com W: www.micropowerdirect.com
Cooling Humidity
Physical
Case Size Case Material Weight 0.87 x 0.49 x 0.30 Inches (22.0 x 12.5 x 7.5 mm) Non-Conductive Black Plastic (UL94-V0) 0.13 Oz (3.9g) Conditions MIL HDBK 217F, 25C, Gnd Benign Conditions 5 VDC Input 12 VDC Input 1.5 mm From Case For 10 Sec All Models Min. 2.0 Min. -0.7 -0.7 Typ. Max. 9.0 18.0 260 650 Typ. Max. Units MHours Units VDC C mW
Reliability Specifications
Parameter MTBF
Absolute Maximum Ratings
Parameter Input Voltage Surge (1 Sec) Lead Temperature Internal Power Dissipation
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
Model Selection Guide
Input Model Number D101VHI D102VHI D103VHI D104VHI D105VHI D106VHI D111VHI D112VHI D113VHI D114VHI D115VHI D116VHI Voltage (VDC) Nominal 5 5 5 5 5 5 12 12 12 12 12 12 Range 4.5 - 5.5 4.5 - 5.5 4.5 - 5.5 4.5 - 5.5 4.5 - 5.5 4.5 - 5.5 10.8 - 13.2 10.8 - 13.2 10.8 - 13.2 10.8 - 13.2 10.8 - 13.2 10.8 - 13.2 Output Load Voltage Current Current Regulation Full-Load No-Load (VDC) (mA, Max) (mA, Min) (%, Max) Current (mA) 303 291 295 303 267 287 126 121 123 126 108 117 55 55 55 55 55 55 30 30 30 30 30 30 5.0 12.0 15.0 5.0 12.0 15.0 5.0 12.0 15.0 5.0 12.0 15.0 200.0 80.0 65.0 100.0 40.0 35.0 200.0 80.0 65.0 100.0 40.0 35.0 4.0 2.0 1.0 2.0 1.0 1.0 4.0 2.0 1.0 2.0 1.0 1.0 10 8 8 10 8 8 10 8 8 10 8 8 Efficiency (%, Typ) 66 66 66 66 72 73 66 66 66 66 74 75 Fuse Rating Slow-Blow (mA) 500 500 500 500 500 500 200 200 200 200 200 200
Notes: 1. Output load regulation is specified for a load change of 20% to 100%. 2. When measuring output ripple, it is recomended that an external 0.33 F ceramic capacitor be placed from the +Vout pin to the -Vout pin for single output units and from each output to common for dual output units. 3. Operation at no-load will not damage these units. However, they may not meet all specifications. 4. Dual output units may be connected to provide a 10 VDC, 24 VDC or 30 VDC output. To do this, connect the load across the positive (+Vout) and negative (-Vout) outputs and float the output common. 5. It is recommended that a fuse be used on the input of a power supply for protection. See the table above for the correct rating.
Derating Curve
Mechanical Dimensions Pin Connections
Pin 1 2 5 6 7 Single +Vin -Vin -Vout No Pin +Vout Dual +Vin -Vin -Vout Common +Vout
NC: No Connection
Capacitive Load
Single Output F Max 680 Dual Output F Max 220
Mechanical Notes:
* All dimensions are typical in inches (mm) * Tolerance x.xx = 0.01 (0.25)
MicroPower Direct
www.micropowerdirect.com
*
292 Page Street Ste D Stoughton, MA 02072
TEL: (781) 344-8226
*
FAX: (781) 344-8481
*
E-Mail: sales@micropowerdirect.com


▲Up To Search▲   

 
Price & Availability of D106VHI

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X