![]() |
|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
page date 1 of 5 09/04/2007 PART NUMBER: CMT-1102 DESCRIPTION: piezo audio transducer SPECIFICATONS operating voltage current consumption sound pressure level electrostatic capacitance operating tempurature storage tempurature dimensions weight material terminal RoHS 25.0 Vp-p max. 4.5 mA max. 68 db min. 12,000 pF 30% -40 ~ +80 C -40 ~ +80 C o11.0 x W9.0 x H1.7 mm 0.5 g max. LCP (white) SMD type yes at 5 Vp-p, square wave, 4.1 KHz at 10 cm / 5 Vp-p, square wave, 4.1 KHz at 1KHz / 1 V APPEARANCE DRAWING tolerance: 0.5 20050 SW 112th Ave. Tualatin, Oregon 97062 phone 503.612.2300 fax 503.612.2383 page date 2 of 5 09/04/2007 PART NUMBER: CMT-1102 DESCRIPTION: piezo audio transducer TYPICAL FREQUENCY RESPONSE CURVE MEASUREMENT METHOD S.P.L. Measuring Circuit Input Signal: 5Vp-p, 4.1 KHz, square wave Mic: RION S.P.L. meter UC30 or equivalent S.G.: Hewlett Packard 33120A function generator or equivalent 20050 SW 112th Ave. Tualatin, Oregon 97062 phone 503.612.2300 fax 503.612.2383 page date 3 of 5 09/04/2007 PART NUMBER: CMT-1102 DESCRIPTION: piezo audio transducer MECHANICAL CHARACTERISTICS item solderability test condition Lead terminals are immersed in rosin for 5 seconds and then immersed in solder bath of 230 5C for 2 0.5 seconds. 1) IR Reflow Pre-heating conditions will be 140~160C for 60~120 seconds. Ascending time up to 150C should be longer than 30 seconds. Heating conditions should be within 10 seconds at 230C min. Peak temperature should be lower than 235C and then be placed in natural conditions for 1 hour before being measured. 2) Soldering Iron Soldering iron of 2705C should be placed 0.5mm above the transducer electrode. Melting solder should be applied to electrode for 31 seconds and then be placed in natural conditions for 4 hours before being measured. For 10 seconds, the force of 9.8N (1.0kg) is applied to each terminal in axial direction. The buzzer should be subjected to a vibration cycle of 10 to 55 Hz for a period of 1 minute. Peak amplitude should be 1.55mm. The vibration test should consist of 2 hours to each of the 3 perpendicular directions. evaluation standard 95% of the lead pad surface must be covered with solder soldering heat resistance No interference in operation. terminal mechanical strength vibration No damage or cutting off. After the test, the part should meet specifications without any damage in appearance and performance, except SPL. SPL should be within 10dB compared with the initial measurement. ENVIRONMENT TEST item high temp. test low temp. test humidity test temp. cycle test test condition After being placed in a chamber at +80C for 240 hours. After being placed in a chamber at -40C for 240 hours. After being placed in a chamber at +40C and 905% relative humidity for 240 hours. The part shall be subjected to 5 cycles. One cycle will consist of: evaluation standard The buzzer will be measured after being placed at +25C for 4 hours. The value of the oscillation frequency/current consumption should be 10% compared to the initial measurements. The SPL should be within 10dB compared to the initial measurements. 20050 SW 112th Ave. Tualatin, Oregon 97062 phone 503.612.2300 fax 503.612.2383 page date 4 of 5 09/04/2007 PART NUMBER: CMT-1102 DESCRIPTION: piezo audio transducer RELIABILITY TEST item operating (life test) test condition 1. Continuous life test: The part will be subjected to 48 hours of continuous operation at +65C with rated voltage applied. 2. Intermittent life test: A duty cycle of 1 minute on, 1 minute off, a minimum of 5,000 times at room temp (+25 2C) with rated voltage applied. evaluation standard The buzzer will be measured after being placed at +25C for 4 hours. The value of the oscillation frequency/current consumption should be 10% compared to the initial measurements. The SPL should be within 10dB compared to the initial measurements. TEST CONDITIONS standard test condition judgement test condition a) tempurature: +5 ~ +35C a) tempurature: +25 2C b) humidity: 45 - 85% b) humidity: 60 - 70% c) pressure: 860-1060 mbar c) pressure: 860-1060 mbar RECOMMENDED TEMPERATURE PROFILE FOR REFLOW OVEN 20050 SW 112th Ave. Tualatin, Oregon 97062 phone 503.612.2300 fax 503.612.2383 page date 5 of 5 09/04/2007 PART NUMBER: CMT-1102 DESCRIPTION: piezo audio transducer PACKAGING 20050 SW 112th Ave. Tualatin, Oregon 97062 phone 503.612.2300 fax 503.612.2383 |
Price & Availability of CMT-1102
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |