 AC-DC
150 Watts SDS150 Series
* * * * * * * 3" x 5" Footprint Fits 1U Applications Convection-cooled
xppower.com
Open Frame & U-Channel Versions Optional Power Fail Detect Signal Optional Low Temperature Operation Up to 90% Efficiency
Specification
Input
Input Voltage Input Frequency Input Current * 90-264 VAC (120-370 VDC) * 47-63 Hz * 2.0 A at 115 VAC 1.0 A at 230 VAC Inrush Current * 20 A at 115 VAC 63 A at 230 VAC Power Factor * >0.95 Earth Leakage Current * <0.40 mA at 115 VAC <0.75 mA at 230 VAC Input Protection * 3.15 A on board fuse
General
Efficiency Isolation * 88% typical, 90% max * 3000 VAC Input to Output 1500 VAC Input to Ground 500 VDC Output to Ground * PWM 60 kHz typical, PFC 100 kHz typical * 6.9 W/In3 for open frame version * Power Fail Detect = TTL low (option) * >100 kHrs per MIL-HDBK-217F
Switching Frequency Power Density Signals MTBF
Environmental
Operating Temperature * 0 C to +70 C, derate linearly from 100% load at +50 C to 50% load at +70 C, low temperature option `-L' -40 C Cooling * Convection-cooled Operating Humidity * 5-95% RH, non-condensing Storage Temperature * -40 C to +85 C Vibration * 2 g on 3 axes
Output
Output Voltage Output Voltage Trim Initial Set Accuracy Minimum Load Start Up Delay Start Up Rise Time Hold Up Time Line Regulation Load Regulation Transient Response Ripple & Noise Overvoltage Protection Overload Protection Short Circuit Protection Temperature Coefficient * * * * * * * * * * * * * * * See table 5% 1% No minimum load required 2 s max 2 ms typical >16 ms 1% max, 0.5% typical 5% max, 3.0% typical 4% max deviation, recovery to within 1% in 500 s for a 50% load change 1% pk-pk max 112-132%, recycle input to reset 110-150% with auto recovery Trip & restart (Hiccup mode), auto recovery 0.04%/C
EMC & Safety
Emissions Harmonic Currents Voltage Flicker ESD Immunity Radiated Immunity EFT/Burst Surge Conducted Immunity Dips & Interruptions * * * * * * * * * EN55022, FCC Part 15, level B conducted EN61000-3-2 EN61000-3-3 EN61000-4-2, level 2 Perf Criteria A EN61000-4-3, 3 V/m Perf Criteria A EN61000-4-4, level 2 Perf Criteria A EN61000-4-5, level 3 Perf Criteria A EN61000-4-6, level 2 Perf Criteria A EN61000-4-11, 70% UT for 10 ms, 40% UT for 100 ms, <5% UT for 5000 ms Perf Criteria A, B, B * EN60950-1, UL60950-1, CSA60950-1 per cUL, CE Mark LVD
Safety Approvals
AC-DC
Models and Ratings
Maximum Output Power 144 W 150 W 150 W 150 W 150 W 150 W 150 W 150 W Output Voltage 9V 12 V 15 V 18 V 24 V 30 V 36 V 48 V Output Current Minimum 0A 0A 0A 0A 0A 0A 0A 0A Maximum 16.00 A 12.50 A 10.00 A 8.33 A 6.25 A 5.00 A 4.17 A 3.13 A Total Regulation(1) 5% 5% 5% 4% 3% 2% 2% 2%
SDS150
Model Number(2,4,5,6) SDS150PS09B^ SDS150PS12B^ SDS150PS15B^ SDS150PS18B^ SDS150PS24B^ SDS150PS30B SDS150PS36B SDS150PS48B^
Notes
1. Total regulation includes initial set accuracy, line regulation and load regulation. 2. For optional 2 pin Molex input, add suffix `-D' to model number. Example SDS150PS12-D. 3. For non-standard voltages contact sales office. 4. For optional Power Fail Detect signal (PFD), add suffix `-P' to model number . Example: SDS150PS48B-P. 5. For optional PCB only version, delete suffix `B' from model number. Example SDS150PS48. 6. For optional low temperature operation, add suffix `-L' to model number. Example: SDS150PS12-L Available from Farnell. See pages 204-206. ^ Available from Newark. See pages 207-208.
Mechanical Details
Open Frame
1.16 (29.6)
All dimensions are in inches (mm) Tolerance: 0.02 (0.5) Weight: 1.23 lbs (560 g) approx.
M3 x P0.5 (Mounting Holes) x 4 o4.0 (Mounting Holes) x 4
1.57 (40.0)
0.80 (20.3)
4.55 (115.6)
0.22 (5.7)
0.56 (14.2)
0.22 (5.5)
5.00 (127.0)
1.40 (35.6)
P2 1
Pin 1 2 3 4 5 6
3.00 (76.2)
3.00 (76.2)
2.57 (65.3)
0.32 (7.9)
P2 - PIN CONNECTIONS Function Pin V1 7 V1 8 V1 9 V1 10 V1 11 V1 12 13
Function Return Return Return Return Return Return PFD(2)
AC Input
DC Output
L N G P1 13
Pitch = 3.96 mm
Notes:
0.12 (3.0)
PFD
1.21 (30.7)
0.80 (20.3)
U Channel
1. Dimensions in inches (mm), tolerance 0.02 (0.5). 2. Optional Power Fail Detect signal on `P' versions only. Standard models have no connection for pin 13. 3. Input connector P1 mates with Molex housing 09-50-3051 and Molex 2478 series crimp terminal. 4. Output connector P2 mates with Molex housing 09-50-3131 and Molex 2478 series crimp terminal. 5. For mating connector kit order part number SDS120 CON KIT. 6. For cable harness order part number SDS120S LOOM. 7. DIN clips are available for alternate mounting order 2 x `DIN CLIP'. 8. For optional cover kit order part number SDS150 COVER. To receive unit with cover fitted add suffix `-C' to model number. Height increases by 0.18 (4.5).
0.43 (10.9)
1.16 (29.6)
1.18 (30.0)
0.54 (13.6) AC Input
GN P1 L
M3* P0.5 (Mounting Holes) x 5
1.18 (30.0)
Power Fail Detect
5.00 (127.0)
4.00 (101.6) 4.50 (114.3)
3.90 (99.06)
45.0 (114.3)
+5 V
PFD is +5 V for normal operation. Source current is 5 mA max.
0.25 (6.4)
0.25 (6.4)
ADJ
13
1 P2
0.55 (14.0)
2.57 (65.3) M3* P0.5 (Mounting Holes) x 4
PFD Pitch = 3.96 mm
DC Output 0.67 (16.9)
Pin 13 PFD is <0.4 V for either AC Fail (<90 VAC) or DC Fail (<95% Vnom). Sink current is 10 mA max.
1.62 (41.2)
Internal
3.21 (81.5)
22-Jun-07


▲Up To Search▲   

 
Price & Availability of SDS150PS09B

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X