![]() |
|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
S/BIP/SCB345100/B/30/10/2001 Relais Statique Double Double Solid State Relay * Sortie AC asynchrone : 12-280Vac - 2 x 50A (1500A2s). * 2 commandes separees . * Connection de Puissance par FASTONS * Connection de commande par picots ( connecteur ) * 12-280VAC - 50A x 2 Random AC Output. * 1 control by leg * Power connections by FASTONS * Control connections by connector page 1 / 2 F/GB SCB345100 4-30VDC Control 2 x 50Amps 230VAC output 32 6,3x0,8 19,6 O 4,7 44,5 29,2 L1 + 1 input L1 L2 output T1 35,8 47,6 58 10 7,62 +2 - L2 + 2 T1 1+ T2 - input output T2 11,1 4,57 5,2 Inputs : 4 pins 0,64mm sq. - manufacturers : Berg ,Mollex ,AMP , Proner comatel ... Other input terminals on request Caracteristiques de commande (a 20C) / Control characteristics (at 20C) Parameter Tension de commande / Control voltage Courant de commande / Control current (@ Uc nom ) Tension de relachement/Release voltage Resistance interne / Input internal resistor fig.1 Tension inverse / Reverse voltage Symbol Uc Ic Uc off Rc Urv Min 4 3 1 DC Nom Max 30 Unit V mA V V VRms VRms VRms fig. 1 :Caracteristique d'entree / Control characteristic fig1 : Caracteristique d'entree / Control characteristic 30 28 26 24 22 20 18 16 14 12 10 8 6 4 2 0 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 30 Caracteristiques d'entree-sortie (a 20C) / Input-output characteristics (at 20C) Isolement entree-sortie/Input-output isolation @500m Uimp/Ui 3300 Isolement sortie-semelle/Output-case isolation @500m Uimp/Ui 3300 Isolement entre voies / Leg 1-Leg 2 isolation @500m Uimp/Ui 2500 Caracteristiques generales / General characteristics Parameter Poids/Weight Plage de temperature de stockage / Storage temprange Plage de temperature de fonctionnement/Operating temprange Resistance thermique Jonction-Case/Junct.-Case thermal resistance(1 leg) Ic (mA) 1000 Uc (V) Conditions Symbol Typ. 110 -40/+100 -40/+100 0,5 Unit g C C C/W Proud to serve you All technical caracteristics are subject to change without previous notice. Caracteristiques sujettes a modifications sans preavis. celduc r e l a i s S/BIP/SCB345100/B/30/10/2001 page 2 / 2 F/GB Caracteristiques de sortie(a 20C) / Output characteristics (at 20C) Parameter Tension de charge / Load voltage Plage tension de fonctionnement / Operating range Tension crete (ecreteur de tension) / Peak voltage (clamping voltage) Niveau de synchonisation / Synchronizing level Tension d'amorcage / Latching voltage Courant nominal AC1/ AC1 nominal current Courant de surcharge non repetitif /Non repetitive overload current Chute tension directe crete/ On state voltage drop Courant de fuite etat bloque/ Off state leakage current Courant de charge minimum / Minimum load current Temps de fermeture/ Turn on time Temps d'ouverture/ Turn off time Plage de frequence / Operating frequency range dv/dt etat bloque / Off state dv/dt dI/dt maximum non repetitif/ Maximum di/dt non repetitive I2t (<10ms) Possibilte de protection exterrieure / External protection possibilty Symbol Ul Ulmin-max Up Usync Il nom Ua ( see Fig. 2 ) Il AC1 tp=10ms (Fig. 3) Itsm @ Il nom Vd @Ul, 50Hz Ilk Ilmin Uc nom DC ,f=50Hz ton max Uc nom DC ,f=50Hz toff max f dv/dt di/dt I2t Conditions Typ. 230 12-280 600 random 10 50(*) 550 1,6 1 5 0,1 10 10-440 500 50 1500 fuse Unit V rms V rms V V V A rms A V mA mA ms ms Hz V/s A/s A2s Fig.2 Courbes thermiques / Thermal characteristics Puissance dissipee / Power dissipation (W) 150 140 MODELE / TYPE : 50A 0C 0C/W / C/W ,2 0,2 (*) connectique limitee a 20A connections limited at 20A 130 W W C C/ 4 0, 120 110 100 90 80 70 60 50 40 30 20 10 0 0 5 10 15 20 25 30 35 40 Courant efficace / RMS current W C/ 5 5 ,5 0, 1 ways 0, 9 C/ W 1, 2 1, C 35 /W 1, C/W 6 C/ W 2 C/ W 2,6 C/ W 4C/ W SANS RADIA TEUR 45 I(A) 0 10 20 30 40 50 60 70 80 90 100 110 Tamb(C) Temperature ambiante / Ambient temperature Fig.3 Surcharge de courant : Itsm (Apeak) = f(t) pour modele 50A(Itsm=550A) Surge current : Itsm (Apeak) = f(t) for 50A models with Itsm =550A 600 Itsm (Apeak) 1 -Itsm non repetitif sans tension reappliquee est donne pour la determination des protections. No repetitive Itsm is given without voltage reapplied for the determination of the protection. 2 -Itsm repetitif est donne pour des surcharges de courant (Tj initiale=70C). La repetition de ces surcharges de courant diminue la duree de vie du Relais. Repetitive Itsm is given for inrush current with initial Tj = 70C. The repetition of the surge current decrease the lifetime SSR's . 400 Surcharge de courant non repetitive sans tension reappliquee / No repetive surge current without voltage reapplied. 200 Surcharge de courant repetitive avec tension reappliquee Repetive surge current with voltage reapplied. 0 0,01 0,1 t (s) 1 10 celduc r e l a i s www.celduc.com Rue Ampere B.P. 4 42290 SORBIERS - FRANCE E-Mail : celduc-relais@celduc.com Fax +33 (0) 4 77 53 85 51 Service Commercial France Tel. : +33 (0) 4 77 53 90 20 Sales Dept.For Europe Tel. : +33 (0) 4 77 53 90 21 Sales Dept. Asia : Tel. +33 (0) 4 77 53 90 19 Temperature semelle max.(C) / Max case temperature (C) 2 ways 90C W C C/ 5 75 0 0, |
Price & Availability of SCB345100
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |