![]() |
|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
One-line Bi-directional TVS Diode AOZ8231 General Description The AOZ8231 is a one-line bi-directional transient voltage suppressor diode designed to protect voltage sensitive electronics from high transient conditions and ESD. This device incorporates one TVS diode in an ultra-small SOD923 package. It may be used to meet the ESD immunity requirements of IEC 61000-4-2, Level 4 (15kV air, 8kV contact discharge). The AOZ8231 comes in an RoHS compliant SOD923 package and is rated over a -40C to +85C ambient temperature range. The ultra-small 1.0 x 0.6 x 0.4mm SOD923 package makes it ideal for applications where PCB space is a premium. The small size and high ESD protection makes it ideal for protecting voltage sensitive electronics from high transient conditions and ESD. Features ESD protection for high-speed data lines: - Exceeds: IEC 61000-4-2 (ESD) 24kV (air), 24kV (contact) - Human Body Model (HBM) 30kV - IEC 61000-4-5 (Lightning) 5A (8/20S) - IEC 61000-4-4 (EFT) 40A Small package saves board space Low insertion loss Low clamping voltage Low operating voltage: 5.0V Pb-free device Applications Portable handheld devices Keypads, data lines, buttons Notebook computers Digital Cameras Portable GPS MP3 players Typical Application Pin Configuration Signal Line Bidirection Protection of Single Line Rev. 1.9 October 2008 www.aosmd.com Page 1 of 6 AOZ8231 Ordering Information Part Number AOZ8231NI-05L Ambient Temperature Range -40C to +85C Package SOD923 Environmental RoHS Compliant Green Product * All AOS products are offered in packages with Pb-free plating and compliant to RoHS standards. * Parts marked as Green Products (with "L" suffix) use reduced levels of Halogens, and are also RoHS compliant. Please visit www.aosmd.com/web/quality/rohs_compliant.jsp for additional information. Absolute Maximum Ratings Exceeding the Absolute Maximum ratings may damage the device. Parameter VP - VN Peak Pulse Current (IPP), tP = 8/20s Storage Temperature (TS) ESD Rating per IEC61000-4-2, Contact ESD Rating per IEC61000-4-2, ESD Rating per Human Body Air(1) Model(2) (1) Rating 5V 5A -65C to +150C 24kV 24kV 30kV Notes: 1. IEC 61000-4-2 discharge with CDischarge = 150pF, RDischarge = 330. 2. Human Body Discharge per MIL-STD-883, Method 3015 CDischarge = 100pF, RDischarge = 1.5k. Maximum Operating Ratings Parameter Junction Temperature (TJ) Rating -40C to +85C Electrical Characteristics TA = 25C unless otherwise specified. Symbol IPP VCL VRWM IR VBR Parameter Maximum Reverse Peak Pulse Current Clamping Voltage @ IPP Working Peak Reverse Voltage Maximum Reverse Leakage Current @ VRWM Breakdown Voltage @ IT Symbol IT IF VF Ppk CJ Test Current Parameter Forward Current Forward Voltage @ IF Peak Power Dissipation Max. Capacitance @ VR = 0 and f = 1MHz Electrical Characteristics TA = 25C unless otherwise noted, VF = 0.9V Max. @ IF = 10mA for all types Device AOZ8231NI-05L Device Marking HG VRWM (V) Max. 5.0 VBR (V) Min. 6.0 IR (A) Max. 0.1 VF (V) Typ. 1.0 VCL Max. IPP = 1A 12.00 IPP = 5A 14.00 IPP = 12A 18.00 CJ (pF) Typ. 12 Rev. 1.9 October 2008 www.aosmd.com Page 2 of 6 AOZ8231 Typical Performance Characteristics Clamping Voltage vs. Peak Pulse Current 20 Clamping Voltage, VCL (V) I/O - Gnd Insertion Loss (S21) vs. Frequency (Vp = 3.3V) 5 0 Insertion Loss (dB) (tperiod = 100ns, tr = 1ns) 18 16 14 12 10 8 -5 -10 -15 -20 -25 0 2 4 6 8 10 12 1 10 100 Frequency (MHz) 1000 10000 Peak Pulse Current, IPP (A) Capacitance vs. Reverse Bias 13 12 Capacitance (pF) 11 10 9 8 7 6 0 1 2 3 4 5 Reverse Bias (Volts) Rev. 1.9 October 2008 www.aosmd.com Page 3 of 6 AOZ8231 Package Dimensions, SOD923 E1 Cathode Mark b D L B E A aaa CAB TOP VIEW BOTTOM VIEW View `C' A C Seating Plane c A1 SIDE VIEW VIEW `C' RECOMMENDED LAND PATTERN 0.90 Dimensions in millimeters Symbols A A1 b c D E E1 L aaa Min. -- 0.00 0.15 0.07 0.55 0.75 0.95 0.15 Nom. -- -- 0.20 0.12 0.60 0.80 1.00 0.20 0.08 Max. 0.41 0.05 0.25 0.14 0.65 0.85 1.05 0.25 Dimensions in inches Symbols A A1 b c D E E1 L aaa Min. -- 0.00 0.006 0.003 0.022 0.030 0.037 0.006 Nom. -- -- 0.008 0.005 0.024 0.031 0.039 0.008 0.003 Max. 0.016 0.002 0.010 0.006 0.026 0.033 0.041 0.010 0.40 UNIT: mm 0.30 Notes: 1. All dimensions are in millimeters. 2. Dimensions are inclusive of plating. 3. Controlling dimension is millimeter, converted inch dimensions are not necessarily exact. 4. The cathode mark is optional. 5. Package body sizes exclude mold flash and gate burrs. Mold flash at the non-lead sides should be less than 3 mils each. Rev. 1.9 October 2008 www.aosmd.com Page 4 of 6 AOZ8231 Tape and Reel Dimensions, SOD923 Tape P1 P2 D0 D1 E1 B - B' Section K0 Max 5 E2 E B0 P0 A0 Max 5 A - A' Section UNIT: mm Feeding Direction Package SOD923 A0 B0 K0 D0 D1 E 8.0 0.2 E1 1.75 0.1 E2 P0 P1 4.0 0.1 P2 T 0.70 1.12 0.48 o1.50 o0.5 0.05 0.05 0.05 0.1 0.05 3.5 2.0 0.05 0.05 2.0 0.229 0.05 0.02 Reel 2xR6 60 30 W1 S1 S 2xR5 1.1 +0.1 -0 M o26.15 -0 +0.1 K N K1 E H H1 W Back View UNIT: mm Arbor Hole Detail A Barcode Label Section: B - B' Front View Tape Size 8mm Reel Size o180 M o177.7 0.5 N o54.4 0.5 W 8.8 0.5 W1 1.15 +0.2 / -0.0 H o13.2 0.3 H1 o15.8 K 10.4 K1 11.7 S S1 E 2.8 0.1 2.3 4.9 0.1 0.1 Leader/Trailer and Orientation Cathode Trailer Tape 300mm min. Rev. 1.9 October 2008 Components Tape Orientation in Pocket Leader Tape 500mm min. Page 5 of 6 www.aosmd.com AOZ8231 Part Marking GC Product Number Code Date Code Alpha & Omega Semiconductor reserves the right to make changes at any time without notice. LIFE SUPPORT POLICY ALPHA & OMEGA SEMICONDUCTOR PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT DEVICES OR SYSTEMS. As used herein: 1. Life support devices or systems are devices or systems which, (a) are intended for surgical implant into the body or (b) support or sustain life, and (c) whose failure to perform when properly used in accordance with instructions for use provided in the labeling, can be reasonably expected to result in a significant injury of the user. 2. A critical component in any component of a life support, device, or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness. Rev. 1.9 October 2008 www.aosmd.com Page 6 of 6 |
Price & Availability of AOZ8231
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |