If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
* Features *Universal AC input / Full range *Built-in active PFC function, PF>0.95 *Protections:Short circuit/Over load/Over voltage *Free air cooling convection *CH4: Polarity is selectable *Fixed switching frequency at 100KHz(Optional) *3 year warranty VQP-100C Switching Power Supply CH1 DC output voltage Output V. tolerance Output rated current Output current range Ripple & noise p-p Line regulation Load regulation Max. output power Efficiency DC voltage adj. Input voltage range AC current Inrush current Leakage current Overload protection Over voltage protection Over temp. protection Temperature coefficient Set up, rise, hold up time Power factor Vibration Withstand voltage Isolation resistance Working temp., humidity Storage temp., humidity Dimensions Weight Safety standards EMC standards 5V 3% 10A 2-10A CH2 15V 6, -10% 2.2A 0.3-3A CH3 -15V 8% 1A 0.15-1A 150mV 2% 6% CH4 -5V 5% 0.6A 0-1A 100mV 1% 2% 100mV 150mV 1% 2% 2% 6% 101W 77% CH1: +10, -5% 90~264VAC 47~63Hz; 127-370VDC 1.5A/115V 0.75A/230V cold start 40A <3.5mA/240VAC 105%~135%, pulsing (hiccup mode), auto restart. CH1:5.75~6.75V 95C5C TSW1 type: shutdown reset: auto recovery 0.3%/ C(0~50C) 1s, 50ms, 16ms PF>0.95/230VAC, PF>0.98/115VAC 10~500Hz, 2G 10 min./1 cycle, period fo 60 min. each axes I/P-O/P: 3KVAC, I/P-FG: 1.5KVAC, O/P-FG: 0.5KVAC for 1 min. I/P-O/P, I/P-FG, O/P-FG: 500VDC / 100M Ohms min. -10C~+60C (refer to output derating curve), 20%-90% RH -20C~+85C, 10%-95% RH 7.83x3.9x1.97 inches (199x99x50mm) case: 916A 1.61lbs (1.1Kgs) UL1950, TUV EN60950 approved EN55022 class B, EN61000-4-2,3,4,5,6,8,11; ENV50204, EN61000-3-2,-3, EN55024 verification Notes: 1. 2. 3. 4. 5. 6. All parameters are specified at 230VAC input, rated load, 25C 70% RH ambient Tolerance includes set up tolerance, line regulation, load regulation Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uF & 47 uF capacitor Line regulation is measured from low line to high line at rated load Load regulation is measured from 20% to 100% rated load, and other outputs at 60% rated load. Each output provides up to maximum current, but total load can not exceed max. output power. V-Infinity reserves the right to make changes to its products or to discontinue any product or service without notice, and to advise customers to verify the most up-to-date product information before placing orders. V-Infinity assumes no liability or responsibility for customer's applications using V-Infinity products other than repair or replacing (at V-I's option) V-Infinity products not meeting V-I's published specifications. Nothing will be covered outside of standard product warranty. V-Infinity, LLC, 9615 SW Allen Blvd Suite 103, Beaverton, OR 97005 www.v-infinity.com 1-866-372-1258 * Derating Curve VQP-100C Switching Power Supply Output Derating VS Input Voltage Dimensions V-Infinity, LLC, 9615 SW Allen Blvd Suite 103, Beaverton, OR 97005 www.v-infinity.com 1-866-372-1258 |
Price & Availability of VQP-100C
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |